Permit #2026010442

Permit Details

Status: COED

Parcel Id: 04-11-30-5571-00000-3310
CONDITIONED SPACE: 2239 sqft
GARAGE: 416 sqft
OPENED PORCH (WITH ROOF) : 60 sqft
OPENED PORCH (WITH ROOF) : 130 sqft
Total Square Footage: 2845 sqft
Subdivision: 2366 - SOMERSET SUBDIVISION PH 2
Job Phone: 904-596-6645
Location Address: 31 SOMERSET AVE
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 01/27/2026
NOC: RECORDED
Applicant name: MICHAEL T HOLDER
Owner: KB HOME JACKSONVILLE LLC

Address

10475 FORTUNE PARKWAY

JACKSONVILLE, FL 32256

Address

SUITE 100

JACKSONVILLE, FL 32256

Lot: 331
Contracted Stated Job Value: ¤140,000.00
Job Description: NEW SINGLE FAMILY DWELLING
Type: CN

Contractor

KB HOME JACKSONVILLE, LLC
Status Location Address Mailing Address State License Number Phone
ACTIVE

10475 FORTUNE PKWY

JACKSONVILLE, FL 32256

SUITE 100

JACKSONVILLE, FL 32256

CGC1509034 (Exp: 08/31/2026) 904-596-6645

Sub Contractors

LARRY WILLIAMS
Status Location Address State License Number Phone
ACTIVE

1750 EMERSON ST

JACKSONVILLE, FL 32207

LI45034 (Exp: 08/31/2026) 904-721-5431
BOBBY WAYNE CAMPBELL
Status Location Address State License Number Phone
ACTIVE

117 GUTHRIE ROAD

GREEN COVE SPRINGS, FL 32043

CCC1326752 (Exp: 08/31/2026) 904-200-1600
JAMES E LINTON
Status Location Address State License Number Phone
ACTIVE

200 COLLEGE DR

ORANGE PARK, FL 32065

EC0001152 (Exp: 08/31/2026) 904-272-0272
COREY MICHAEL TENNANT
Status Location Address State License Number Phone
ACTIVE

3370 AGRICULTURAL CNETER DR

ST AUGUSTINE, FL 32092

CAC1819063 (Exp: 08/31/2026) 904-829-8898
BENJAMIN MICHAEL RAY
Status Location Address Mailing Address State License Number Phone Fax
ACTIVE

6310 MABLETON PKWY

JACKSONVILLE, FL 32216

SUITE 1000

MABLETON, GA 30126

CFC1428415 (Exp: 08/31/2026) 904-861-5421 904-861-5426

Inspection History

Type Request Date Result Inspector
ROW - FINAL APRON (AFTER POUR) 05/07/2026 APPROVED EMADISON
Note: ** AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW - FINAL INSPECTION 05/07/2026 APPROVED EMADISON
Note: ** AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
U -UTILITY RESIDENTIAL FINAL 05/07/2026 APPROVED BVEIGA
Note: 5/4/2026 - PREVIOUS INSPECTION NOTES Needs reclaim pit replaced
ROW- FINAL SURVEY/GRADING CERTIFICATION 05/06/2026 APPROVED TPOLACEK
Note: BASED ON THE ENGINEERS SIGNED AND SEALED LGDC MEETING THE COPC MINIMUM REQUIREMENTS AT THE TIME OF THIS INSPECTION, I AM APPROVING THIS DOCUMENT. Effective 03-25-26, the ROW Field Survey requirement is no longer in effect for Final Lot Grading and Drainage Certificates for new construction on subdivision and infill lots. All Final Lot Grading and Drainage Certificates for these projects will now be reviewed and approved only in the office. Field verification for the ROW-FIELD SURVEY will no longer be required as part of the standard approval process for these permit types
U -UTILITY RESIDENTIAL FINAL 05/04/2026 Disapproved - NO FEE BHAINES
Note: Needs reclaim pit replaced
BLD - BUILDING FINAL 05/04/2026 FINAL APPROVED JSTEWART
Note: 5/1/2026 - PREVIOUS INSPECTION NOTES 4/29/2026 - PREVIOUS INSPECTION NOTES 1. Plumbing vent stack on right side of roof is to short min 6". 2. Please seal SGD threshold to concrete (exterior). 3. Condensate line fittings not glued in AHU closet. 4. No Hot water. 5. hood vent needs to be installed and exhaust duct sealed.
BLD - BUILDING FINAL 05/01/2026 CANCELLED BY APPLICANT JSTEWART
Note: 4/29/2026 - PREVIOUS INSPECTION NOTES 1. Plumbing vent stack on right side of roof is to short min 6". 2. Please seal SGD threshold to concrete (exterior). 3. Condensate line fittings not glued in AHU closet. 4. No Hot water. 5. hood vent needs to be installed and exhaust duct sealed.
BLD - BUILDING FINAL 04/29/2026 Disapproved - NO FEE JSTEWART
Note: 1. Plumbing vent stack on right side of roof is to short min 6". 2. Please seal SGD threshold to concrete (exterior). 3. Condensate line fittings not glued in AHU closet. 4. No Hot water. 5. hood vent needs to be installed and exhaust duct sealed.
U-CROSS CONNECTION 04/21/2026 APPROVED BWRIGHT
ELECTRIC - EARLY POWER 04/08/2026 APPROVED JSTEWART
Note: Inspector Notes from Inspection 2200 Authorize release of email
ROW- PRE-APRON (PRE-POUR) 03/23/2026 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. . TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, IN THE UPCOMING MONTHS THE DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS WILL BE REQUIRED TO BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. YOU WILL RECEIVE A NEWS BLAST WHEN THIS BECOMES NECESSARY
DRYWALL NAILING 03/19/2026 APPROVED JSTEWART
Note: Inspector Notes from Inspection 2320 Inspector Notes from Inspection 2420 1. Please cap with approved method, unused opening in breaker panel. NEC 110.12(A) / 408.7 2. Spare bath duct adapter needs secured to assembly. per manufactuerer / M1501.1 EXHAUST TO EXTERIOR 3. Spare bath duct to assembly needs mechanical fastener. FBCR M1601.4.1 4. 5ft head fail (empty) FBCR P2503.5 5. Master bath Both exhaust fans require being sealed and mechanical fastener at duct to assembly connection. FBCR M1601.4.1 Will check at insulation
INSULATION 03/16/2026 APPROVED PKNAPIK
Note: Inspector Notes from Inspection 2420 1. Please cap with approved method, unused opening in breaker panel. NEC 110.12(A) / 408.7 2. Spare bath duct adapter needs secured to assembly. per manufactuerer / M1501.1 EXHAUST TO EXTERIOR 3. Spare bath duct to assembly needs mechanical fastener. FBCR M1601.4.1 4. 5ft head fail (empty) FBCR P2503.5 5. Master bath Both exhaust fans require being sealed and mechanical fastener at duct to assembly connection. FBCR M1601.4.1 Will check at insulation
LATH/BRICK/ WATER BARRIER 03/16/2026 APPROVED - AS NOTED KSANDOE
Note: Inspector Notes from Inspection 2420 1. Please cap with approved method, unused opening in breaker panel. NEC 110.12(A) / 408.7 2. Spare bath duct adapter needs secured to assembly. per manufactuerer / M1501.1 EXHAUST TO EXTERIOR 3. Spare bath duct to assembly needs mechanical fastener. FBCR M1601.4.1 4. 5ft head fail (empty) FBCR P2503.5 5. Master bath Both exhaust fans require being sealed and mechanical fastener at duct to assembly connection. FBCR M1601.4.1 Will check at insulation
ALL ROUGH 03/11/2026 APPROVED - AS NOTED JSTEWART
Note: 1. Please cap with approved method, unused opening in breaker panel. NEC 110.12(A) / 408.7 2. Spare bath duct adapter needs secured to assembly. per manufactuerer / M1501.1 EXHAUST TO EXTERIOR 3. Spare bath duct to assembly needs mechanical fastener. FBCR M1601.4.1 4. 5ft head fail (empty) FBCR P2503.5 5. Master bath Both exhaust fans require being sealed and mechanical fastener at duct to assembly connection. FBCR M1601.4.1 Will check at insulation
ELECTRIC-TUG 03/11/2026 APPROVED - AS NOTED JSTEWART
Note: Authorize release of email
GRAVITY SEWER TEST 03/05/2026 APPROVED JSTEWART
Note: Live virtual inspection
SEWER TIE IN 03/05/2026 APPROVED JSTEWART
Note: Live virtual inspection
ROOF VALLEY & METAL 03/05/2026 APPROVED JSTEWART
WALL SHEATHING 03/04/2026 APPROVED JSTEWART
Note: 3/3/2026 - PREVIOUS INSPECTION NOTES Missing nails at back left corner, plywood to bottom plate.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/04/2026 APPROVED JSTEWART
Note: 3/3/2026 - PREVIOUS INSPECTION NOTES
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/03/2026 CANCELLED BY APPLICANT JSTEWART
WALL SHEATHING 03/03/2026 Disapproved - NO FEE JSTEWART
Note: Missing nails at back left corner, plywood to bottom plate.
MONOLITHIC SLAB 02/18/2026 APPROVED JSTEWART
Note: 2/17/2026 - PREVIOUS INSPECTION NOTES Interior portion of garage non bearing step down not to plan SD1 (Q).
MONOLITHIC SLAB 02/17/2026 Disapproved - NO FEE JSTEWART
Note: Interior portion of garage non bearing step down not to plan SD1 (Q).
PLUMBING 1ST ROUGH UNDERGROUND 02/13/2026 APPROVED JSTEWART
WATER METER INSTALLATION REQUEST 02/13/2026 APPROVED ISANDERSON
FORMBOARD SURVEY (OFFICE USE ONLY) 02/12/2026 APPROVED PFLANAGAN

Review History

Department Status Date In Date Out
SW1 COMPLETE 02/12/2026 02/12/2026
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON COMPLETE 02/12/2026 02/12/2026
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BLD COMPLETE 01/15/2026 01/21/2026
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
CUSVC COMPLETE 01/15/2026 01/22/2026
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 01/15/2026 01/20/2026
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 01/15/2026 01/16/2026
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
GAS COMPLETE 01/15/2026 01/16/2026
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
LOCATE COMPLETE 01/15/2026 01/21/2026
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH COMPLETE 01/15/2026 01/20/2026
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 01/15/2026 01/23/2026
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 01/15/2026 01/16/2026
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
URB COMPLETE 01/15/2026 01/22/2026
Note: Released By: MATTHEW SIERRA - (386)286-2002 - MSIERRA@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
WATER-METER ¤874.47 01/27/2026
WATER- TURN ON ¤50.00 01/27/2026
ADMINISTRATIVE RESIDENTIAL ¤30.00 01/27/2026
INSPECTION - RESIDENTIAL ¤1,168.75 01/27/2026
PLAN REVIEW - RESIDENTIAL ¤331.50 01/27/2026
FC IMPACT FEE EMS ¤62.00 01/27/2026
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 01/27/2026
FC IMPACT FEE LIBRARY ¤268.00 01/27/2026
FIRE RES IMPACT FEE 10-25 ¤942.00 01/27/2026
WATER METER W/OUT TAP ¤965.03 01/27/2026
PARKS IMPACT FEE 10-25 ¤3,164.00 01/27/2026
RECLAIM WATER PERMIT INSPECTIO ¤40.00 01/27/2026
RSI DRIVEWAY AFTER POUR ¤16.25 01/27/2026
RSE DRIVE PRE POUR INSPECTION ¤32.50 01/27/2026
RSI FIELD SURVEY INSPECTION ¤48.75 01/27/2026
RSI FORMBOARD REVIEW ¤16.25 01/27/2026
RSI PLAN REVIEW NEW ¤48.75 01/27/2026
RSI FNL SURVEY/GRADING CERT ¤48.75 01/27/2026
RSI ROW FINAL INSPECTION ¤16.25 01/27/2026
SCHOOL BOARD IMPACT FEE RES ¤5,450.00 01/27/2026
SURCHARGE FS 533.721 ¤15.30 01/27/2026
SURCHARGE - FS 468.631 ¤22.95 01/27/2026
TRANSP RES IMPACT FEE 10-25 ¤8,441.03 01/27/2026
WASTEWATER PERM INSPECTION ¤80.00 01/27/2026
WASTEWATER PERM REVIEW ¤25.00 01/27/2026
SEWER CAPITAL FACILITY ¤3,628.86 01/27/2026
WATER CAPITAL FACILITY FEE ¤3,091.14 01/27/2026
WATER PERMIT REVIEW ¤25.00 01/27/2026
SITE PLAN 30 ¤30.00 01/27/2026
Fees Total Due: ¤0.00 Total Paid: ¤29,150.53