Status: INSPECT

Parcel Id: 10-11-30-5115-00000-0100
Block: 00000
Subdivision: -
Job Phone: 561-662-3558
Location Address: 1 PINE LAKES PKWY N
Type: CA - COMM ADDITION
Issue Date: 02/27/2026
NOC: RECORDED
Applicant name: SHAN L BROOKS
Owner: FIRST BAPTIST CHURCH OF PALM COAST INC

Address

6050 PALM COAST PKWY NW

PALM COAST, FL 32137

Lot: 0100
Contracted Stated Job Value: ¤400,000.00
Job Description: Cafeteria Addition
Type: CN

Contractor

PWC BUILDS LLC
Status Location Address State License Number Phone
ACTIVE

1301 MADISON ST

PALATKA, FL 32177

CGC1535515 (Exp: 08/31/2026) 561-662-3558

Sub Contractors

RICHARD H SIMMONS JR
Status Location Address State License Number Phone Fax
ACTIVE

PO BOX 1963

BUNNELL, FL 32110

ES12001217 (Exp: 08/31/2026) 386-437-0607 386-437-1847
DANIEL DAVID RUTKOWSKI III
Status Location Address State License Number Phone Fax
ACTIVE

1687 STATE AVENUE

HOLLY HILL, FL 32117

CCC1328639 (Exp: 08/31/2026) 386-290-7490 386-256-0001
GARY LLOYD SHEFFIELD
Status Location Address State License Number Phone
ACTIVE

48 EAGLE LAKES DRIVE

FLAGLER BEACH, FL 32136

CAC048127 (Exp: 08/31/2026) 386-597-3280

Inspection History

Type Request Date Result Inspector
DRYWALL NAILING 06/10/2026 APPROVED HCAMACHO
INSULATION 06/03/2026 APPROVED HCAMACHO
HVAC ROUGH 05/28/2026 APPROVED - AS NOTED HCAMACHO
Note: 1. Smoke detectors will be installed in the ducts.
ROOF VALLEY & METAL 05/27/2026 APPROVED KSANDOE
ELECTRIC 2ND ROUGH 05/14/2026 APPROVED RMARTIN
STOREFRONT 05/05/2026 APPROVED KSANDOE
FRAMING 05/05/2026 APPROVED KSANDOE
LATH/BRICK/WATER BARRIER 05/04/2026 APPROVED KSANDOE
LATH/BRICK/WATER BARRIER 05/01/2026 CANCELLED BY APPLICANT WEB
ROOF SHEATHING / BRACE / TIE DOWN 04/01/2026 APPROVED KSANDOE
EXTERIOR WALL SHEATHING / SHEARWALL 03/25/2026 APPROVED KSANDOE
MONOLITHIC SLAB 03/19/2026 APPROVED KSANDOE
FORMBOARD SURVEY 03/18/2026 APPROVED DLEAP
FOOTER 03/16/2026 APPROVED KSANDOE
STEMWALL FOOTING 03/12/2026 APPROVED KSANDOE
ELECTRIC FINAL
BLD - ADA RAMPS/SIDEWALKS/CROSSWALKS
HVAC FINAL
BUILDING FINAL
FIRE FINAL
LDSC- LANDSCAPE FINAL
U - UTILITY COMMERCIAL FINAL

Review History

Department Status Date In Date Out
PLENG COMPLETE 03/18/2026 03/18/2026
Note: Released By: DENNIS R. LEAP, P.E. - (386)986-2482 - DLEAP@PALMCOASTGOV.COM
MECH COMPLETE 02/12/2026 02/17/2026
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
DSD COMPLETE 02/05/2026 02/05/2026
Note: Released By: DAMARIS RAMIREZ - (386)986-3750 - DRAMIREZ@PALMCOASTGOV.COM
PLUM COMPLETE 02/05/2026 02/09/2026
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH HOLD 02/05/2026 02/09/2026
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide OA calculation to show a cafeteria. Revise ductwork accordingly. Provide updated energy calc and updated M1 page
BLD COMPLETE 02/05/2026 02/09/2026
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ARCHR COMPLETE 02/05/2026 02/12/2026
Note: Released By: RICHARD PICATAGI - (386)986-3760 - RPICATAGI@PALMCOASTGOV.COM
ARCHR HOLD 01/16/2026 02/02/2026
Note: Held By: RICHARD PICATAGI - (386)986-3760 - RPICATAGI@PALMCOASTGOV.COM 1. According to LDC Section 13.04.03, Pitched roofs on nonresidential buildings have a minumum pitch requirement do 5:12. Proposed roof pitch (4:12) does not meet the requirement and is not acceptable. Provide revised plans with roof pitch of 5:12 or steeper. 2. Provide Color Name, MFRA, numerical code and LRV
BLD HOLD 01/16/2026 01/30/2026
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM COMMENTS BELOW PER THE 2023 FLORIDA BUILDING CODE-BUILDING (FBCB), FLORIDA BUILDING CODE-ACCESSIBILITY (FBCA), FLORIDA BUILDING CODE-PLUMBING (FBCP), FLORIDA STATUTES (FS), FLORIDA ADMINISTRATIVE CODE (FAC) AND AUTHORITY HAVING JURISDICTION (AHJ). PLAN RE-SUBMITTAL SHALL BE ACCOMPANIED BY A RESPONSE LETTER SIGNED AND SEALED BY THE APPROPRIATE DESIGN PROFESSIONAL(S). ALL PLAN REVISIONS SHALL BE CLOUDED APPROPRIATELY. 1. Update existing building code year in code analysis. FBC 107.2.1 2. Provide calculation for allowed building area. FBC 506.2 3. Add to code analysis that building is sprinkled. Provide note that fire alarm and fire sprinkler will be on a separate permit. FBC 903.2/ AHJ 4. Revise code analysis to show A2 (cafeteria) FBC 303.3 5. Provide landing dimension at bottom of stairs FBC 1011.6 6.Provide width of stairs. FBC 1005.3.1/1011.2 7. Provide landing dimensions out of double door FBC 1010.1.5 8. Provide accessible means of egress from exit to a public way. Show landing dimensions, width, cross slopes ,runnig slopes of walkway, ramp slopes, hand rails etc.. FBC 1012, 1012.6.4/FBC Accessibility 402,403,405,406,505 9. Provide details on panic hardware for exit doors FBC 1010.2.9 10. Door for office has to open toward the path of egress. FBC 1010.1.2.1 11. Provide means of egress from stairs to publc way. FBC 1005.4 12. Provide details on door thresholds FBC 1010.1.6/ FBC Accessibility 404.2.5 13. Complete the door schedule. Provide lock, and closure details. FBC 1010.2.4 14. Provide height of stairs from ground to top landing. FBC 1011.8 15. Provide entire truss packet. Only first page uploaded. 107.2.1 16. Provide attachment detail for gurards and rails. 107.2.1
DSD HOLD 01/16/2026 01/16/2026
Note: Held By: DAMARIS RAMIREZ - (386)986-3750 - DRAMIREZ@PALMCOASTGOV.COM Update permit documents to have the correct address. The correct address is 1 Pines Lakes Pkwy and not 6050 Palm Coast Pkwy.
ELEC COMPLETE 01/16/2026 01/26/2026
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
FI1 COMPLETE 01/16/2026 01/26/2026
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH HOLD 01/16/2026 01/27/2026
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM COMMENTS BELOW PER THE 2023 FLORIDA BUILDING CODE-BUILDING (FBCB), FLORIDA BUILDING CODE- MECHANICAL (FBCM), FLORIDA BUILDING CODE-ENERGY CONSERVATION (FBCEC), FLORIDA STATUTES (FS), FLORIDA ADMINISTRATIVE CODE (FAC) AND AUTHORITY HAVING JURISDICTION (AHJ). PLAN RE-SUBMITTAL SHALL BE ACCOMPANIED BY A RESPONSE LETTER SIGNED AND SEALED BY THE APPROPRIATE DESIGN PROFESSIONAL(S). ALL PLAN REVISIONS SHALL BE CLOUDED APPROPRIATELY. 1. Revise ventilation calculation to show cafeteria. Also revise duct sizing as needed. FBC Mechanical 403.3.1.1 2. Provide return air out of office.FBC Mechanical 601.6
PLENG COMPLETE 01/16/2026 01/20/2026
Note: Released By: DENNIS R. LEAP, P.E. - (386)986-2482 - DLEAP@PALMCOASTGOV.COM
UD1 COMPLETE 01/16/2026 01/26/2026
Note: Released By: GREG DEGLER - (386)986-2384 - GDEGLER@PALMCOASTGOV.COM
PLUM HOLD 01/16/2026 01/27/2026
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM You have a plumbing contractor listed in the portal. What is the plumbing scope of work/ Plans

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADMINISTRATIVE - COMMERCIAL ¤75.00 02/27/2026
INSPECTION COMMERCIAL ¤2,800.00 02/27/2026
PLAN REVIEW - COMMERCIAL ¤460.00 02/27/2026
IMPACT FEE FIRE ¤3,163.42 02/27/2026
IMPACT FEE TRANSPORTATION ¤10,692.15 02/27/2026
SURCHARGE FS 533.721 ¤33.35 02/27/2026
SURCHARGE - FS 468.631 ¤50.03 02/27/2026
SW ENG REVIEW- 40 ¤40.00 02/27/2026
SITE PLAN 30 ¤30.00 02/27/2026
Fees Total Due: ¤0.00 Total Paid: ¤17,343.95