I want to search for...
Permit #2026010464
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7024-00410-0100 |
| Block: 00410 |
| Subdivision: 7024 - |
| Job Phone: 305-878-9095 |
| Location Address: 21 PRESCOTT LN |
| Type: PO - POOL |
| Issue Date: 01/30/2026 |
| NOC: RECORDED |
| Applicant name: DILLON MICHAEL ROBLES |
| Owner: MINDER CHAD JOSEPH & EVA MICHELLE MINDER |
|
Address 21 PRESCOTT LN PALM COAST, FL 32164 |
| Lot: 0100 |
| Contracted Stated Job Value: ¤69,097.00 |
| Job Description: FIBERGLASS POOL (SCREEN ENCLOSURE BY OTHERS) |
| Type: CN |
Contractor
PELICAN POOLS LLC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
14 MALAGA COURT PALM COAST, FL 32137 |
CPC1461204 (Exp: 08/31/2028) | 305-431-5409 |
Sub Contractors
RICHARD R EDWARDS
| Status | Location Address | State License Number | Phone |
| ACTIVE |
P. O. Box 1637 Bunnell, FL 32110 |
EC13010654 (Exp: 08/31/2026) | (386) 437-1537 |
Inspection History
| Type | Request Date | Result | Inspector |
| POOL DECK | 04/02/2026 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 3/2/2026 1:22:57 PM *** 3/2/26: This inspection was intended to be scheduled for today rather than 4/2/26. 2/27/2026 - PREVIOUS INSPECTION NOTES 2/27/26: Cancelled by Applicant via phone at @ 1104. Waiting on Revision. | |||
| POOL FINAL | 03/31/2026 | FINAL APPROVED | HCAMACHO |
| Note: 3/30/2026 - PREVIOUS INSPECTION NOTES 3/30/26: 1). Remote alarm is required to be located inside the house close to a window or door so it can be verified. FBC- R4501.17.1.9 (Currently remote alarm is plugged into an outlet strip on the Lanai and is turned off). | |||
| POOL FINAL | 03/30/2026 | Disapproved - NO FEE | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 3/30/2026 10:44:38 AM *** 3/30/26: 1). Remote alarm is required to be located inside the house close to a window or door so it can be verified. FBC- R4501.17.1.9 (Currently remote alarm is plugged into an outlet strip on the Lanai and is turned off). | |||
| U -UTILITY RESIDENTIAL FINAL | 03/27/2026 | FINAL APPROVED | BHAINES |
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 03/26/2026 | APPROVED - AS NOTED | FSLADISH |
| Note: 3/26/26 SPOKE WITH MATT CM POOL BUILDER AND WALKED THE CORRECTIONS THAT WERE MADE IN THE REAR OF POOL. THERE WAS A NUMBER SHOWING HIGHER ON THE SURVEY IN THE REAR LEFT CORNER AND NOT THE REQUIRED 3 TENTHS SWALE. AT THE TIME OF THIS ON SITE WALK THROUGH AFTER SPEAKING WITH THE HOMEOWNER AS WELL, I HAVE DETERMINED THAT THE DRAINAGE WILL WORK AND MEETS THE COPC MINIMUM STANDARDS AT THIS TIME. I AM APPROVING THIS FINAL SURVEY AS NOTED THAT BECAUSE ONLY MINOR ISSUES WERE PRESENT ON THE SURVEY, THEY HAVE BEEN ADDRESSED AND CORRECTED IN THE FIELD ______________________________________________________________________________________________________________________________ 3/25/2026 - PREVIOUS INSPECTION NOTES 3/25/26 YOUR CURRENT SURVEY SHOWS THE LEFT SIDE POOL DECK CORNER LOWER THAN THE SWALE SHOWING ADVERSE DRAINAGE BACK ONTO POOL DECK. YOU DO NOT HAVE THE REQUIRED 3 TENTH SWALE TO MOVE THE DRAINGE LEFT TO RIGHT FROM CENTER REAR OFF OF POOL DECK TO FRONT SWALE. SEE PHOTO FOR REFERENCE.. The rear yard is required to drain to the front Sec 300.01 C-6 Sec 300.01 C-6=Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale unless the Topographic Survey/Lot Grading Plan demonstrates a rear yard drainage system with an appropriate outfall. Draining onto adjacent properties will not be allowed outside of the platted 5’ drainage easement. SWALE 3 TENTHS TOE TO SLOPE Section 300.01 D(6) V-17 6) The top of slope of swales along the property lines shall be a minimum of 0.30 of a foot higher than the toe of slope. 3/23/2026 - PREVIOUS INSPECTION NOTES 03-23-26 TPOLACEK*** SITE PLAN INDICATES FFE IS 27.80 FINAL SURVEY INDICATES FFE AS 26.75 ALMOST A FOOT LOWER. FINAL SURVEY ALSO INDICATES THE PATIO AT 26.90 AND THE POOL AT 26.86 BOTH HIGHER THAN FFE OF STRUCTURE. DRAINAGE ELEVATIONS AROUND BACK OF POOL DO NOTT MEET COPC MINIMUM STANDARDS ACCORDING TO THE FINAL SURVEY. INSPECTOR WENT OUT IN THE FIELD TO VERIFY AND RANG DOORBELL HOWEVER THERE WAS NO ANSWER. PLEASE CHECK ELEVATIONS AND RESUBMIT FINAL SURVEY | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 03/26/2026 | APPROVED | FSLADISH |
| Note: 3/26/26 SPOKE WITH MATT CM POOL BUILDER AND WALKED THE CORRECTIONS THAT WERE MADE IN THE REAR OF POOL. THERE WAS A NUMBER SHOWING HIGHER ON THE SURVEY IN THE REAR LEFT CORNER AND NOT THE REQUIRED 3 TENTHS SWALE. AT THE TIME OF THIS ON SITE WALK THROUGH AFTER SPEAKING WITH THE HOMEOWNER AS WELL, I HAVE DETERMINED THAT THE DRAINAGE WILL WORK AND MEETS THE COPC MINIMUM STANDARDS AT THIS TIME. I AM APPROVING THIS FINAL SURVEY AS NOTED THAT BECAUSE ONLY MINOR ISSUES WERE PRESENT ON THE SURVEY, THEY HAVE BEEN ADDRESSED AND CORRECTED IN THE FIELD. ____________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9463 3/26/26 SPOKE WITH MATT CM POOL BUILDER AND WALKED THE CORRECTIONS THAT WERE MADE IN THE REAR OF POOL. THERE WAS A NUMBER SHOWING HIGHER ON THE SURVEY IN THE REAR LEFT CORNER AND NOT THE REQUIRED 3 TENTHS SWALE. AT THE TIME OF THIS ON SITE WALK THROUGH AFTER SPEAKING WITH THE HOMEOWNER AS WELL, I HAVE DETERMINED THAT THE DRAINAGE WILL WORK AND MEETS THE COPC MINIMUM STANDARDS AT THIS TIME. I AM APPROVING THIS FINAL SURVEY AS NOTED THAT BECAUSE ONLY MINOR ISSUES WERE PRESENT ON THE SURVEY, THEY HAVE BEEN ADDRESSED AND CORRECTED IN THE FIELD ______________________________________________________________________________________________________________________________ 3/25/2026 - PREVIOUS INSPECTION NOTES 3/25/26 YOUR CURRENT SURVEY SHOWS THE LEFT SIDE POOL DECK CORNER LOWER THAN THE SWALE SHOWING ADVERSE DRAINAGE BACK ONTO POOL DECK. YOU DO NOT HAVE THE REQUIRED 3 TENTH SWALE TO MOVE THE DRAINGE LEFT TO RIGHT FROM CENTER REAR OFF OF POOL DECK TO FRONT SWALE. SEE PHOTO FOR REFERENCE.. The rear yard is required to drain to the front Sec 300.01 C-6 Sec 300.01 C-6=Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale unless the Topographic Survey/Lot Grading Plan demonstrates a rear yard drainage system with an appropriate outfall. Draining onto adjacent properties will not be allowed outside of the platted 5’ drainage easement. SWALE 3 TENTHS TOE TO SLOPE Section 300.01 D(6) V-17 6) The top of slope of swales along the property lines shall be a minimum of 0.30 of a foot higher than the toe of slope. 3/23/2026 - PREVIOUS INSPECTION NOTES 03-23-26 TPOLACEK*** SITE PLAN INDICATES FFE IS 27.80 FINAL SURVEY INDICATES FFE AS 26.75 ALMOST A FOOT LOWER. FINAL SURVEY ALSO INDICATES THE PATIO AT 26.90 AND THE POOL AT 26.86 BOTH HIGHER THAN FFE OF STRUCTURE. DRAINAGE ELEVATIONS AROUND BACK OF POOL DO NOTT MEET COPC MINIMUM STANDARDS ACCORDING TO THE FINAL SURVEY. INSPECTOR WENT OUT IN THE FIELD TO VERIFY AND RANG DOORBELL HOWEVER THERE WAS NO ANSWER. PLEASE CHECK ELEVATIONS AND RESUBMIT FINAL SURVEY | |||
| ROW - FINAL INSPECTION | 03/26/2026 | APPROVED | FSLADISH |
| Note: 3/26/26 SPOKE WITH MATT CM POOL BUILDER AND WALKED THE CORRECTIONS THAT WERE MADE IN THE REAR OF POOL. THERE WAS A NUMBER SHOWING HIGHER ON THE SURVEY IN THE REAR LEFT CORNER AND NOT THE REQUIRED 3 TENTHS SWALE. AT THE TIME OF THIS ON SITE WALK THROUGH AFTER SPEAKING WITH THE HOMEOWNER AS WELL, I HAVE DETERMINED THAT THE DRAINAGE WILL WORK AND MEETS THE COPC MINIMUM STANDARDS AT THIS TIME. I AM APPROVING THIS FINAL SURVEY AS NOTED THAT BECAUSE ONLY MINOR ISSUES WERE PRESENT ON THE SURVEY, THEY HAVE BEEN ADDRESSED AND CORRECTED IN THE FIELD. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S AND/OR HOMEOWNER’S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 03/25/2026 | Disapproved - NO FEE | FSLADISH |
| Note: 3/25/26 YOUR CURRENT SURVEY SHOWS THE LEFT SIDE POOL DECK CORNER LOWER THAN THE SWALE SHOWING ADVERSE DRAINAGE BACK ONTO POOL DECK. YOU DO NOT HAVE THE REQUIRED 3 TENTH SWALE TO MOVE THE DRAINGE LEFT TO RIGHT FROM CENTER REAR OFF OF POOL DECK TO FRONT SWALE. SEE PHOTO FOR REFERENCE.. The rear yard is required to drain to the front Sec 300.01 C-6 Sec 300.01 C-6=Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale unless the Topographic Survey/Lot Grading Plan demonstrates a rear yard drainage system with an appropriate outfall. Draining onto adjacent properties will not be allowed outside of the platted 5’ drainage easement. SWALE 3 TENTHS TOE TO SLOPE Section 300.01 D(6) V-17 6) The top of slope of swales along the property lines shall be a minimum of 0.30 of a foot higher than the toe of slope. 3/23/2026 - PREVIOUS INSPECTION NOTES 03-23-26 TPOLACEK*** SITE PLAN INDICATES FFE IS 27.80 FINAL SURVEY INDICATES FFE AS 26.75 ALMOST A FOOT LOWER. FINAL SURVEY ALSO INDICATES THE PATIO AT 26.90 AND THE POOL AT 26.86 BOTH HIGHER THAN FFE OF STRUCTURE. DRAINAGE ELEVATIONS AROUND BACK OF POOL DO NOTT MEET COPC MINIMUM STANDARDS ACCORDING TO THE FINAL SURVEY. INSPECTOR WENT OUT IN THE FIELD TO VERIFY AND RANG DOORBELL HOWEVER THERE WAS NO ANSWER. PLEASE CHECK ELEVATIONS AND RESUBMIT FINAL SURVEY | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 03/23/2026 | Disapproved - NO FEE | TPOLACEK |
| Note: 03-23-26 TPOLACEK*** SITE PLAN INDICATES FFE IS 27.80 FINAL SURVEY INDICATES FFE AS 26.75 ALMOST A FOOT LOWER. FINAL SURVEY ALSO INDICATES THE PATIO AT 26.90 AND THE POOL AT 26.86 BOTH HIGHER THAN FFE OF STRUCTURE. DRAINAGE ELEVATIONS AROUND BACK OF POOL DO NOTT MEET COPC MINIMUM STANDARDS ACCORDING TO THE FINAL SURVEY. INSPECTOR WENT OUT IN THE FIELD TO VERIFY AND RANG DOORBELL HOWEVER THERE WAS NO ANSWER. PLEASE CHECK ELEVATIONS AND RESUBMIT FINAL SURVEY | |||
| ELECTRIC AND ALARM | 03/20/2026 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 3/20/2026 12:17:13 PM *** Approved | |||
| SUBGRADE - FIBERGLASS POOL | 03/02/2026 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 3/2/2026 1:22:05 PM *** 2/27/2026 - PREVIOUS INSPECTION NOTES 2/27/26: Cancelled by Applicant via phone at @ 1104. Waiting on Revision. | |||
| POOL DECK | 02/27/2026 | CANCELLED BY APPLICANT | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 2/27/2026 11:04:46 AM *** 2/27/26: Cancelled by Applicant via phone at @ 1104. Waiting on Revision. | |||
| SUBGRADE - FIBERGLASS POOL | 02/27/2026 | CANCELLED BY APPLICANT | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 2/27/2026 11:06:02 AM *** 2/27/26: Cancelled by Applicant via phone at @ 1104. Waiting on Revision. |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 02/27/2026 | 03/04/2026 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 02/27/2026 | 02/27/2026 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 01/29/2026 | 01/29/2026 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 01/29/2026 | 01/29/2026 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 01/29/2026 | 01/30/2026 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 01/29/2026 | 01/29/2026 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| BFLOOD | CANCEL | 01/16/2026 | 01/20/2026 |
| BLD | HOLD | 01/16/2026 | 01/22/2026 |
| Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM Please provide anchoring for the pool to prevent floatation. | |||
| ELEC | COMPLETE | 01/16/2026 | 01/22/2026 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 01/16/2026 | 01/20/2026 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| RSI | COMPLETE | 01/16/2026 | 01/23/2026 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | HOLD | 01/16/2026 | 01/16/2026 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Home owners need to the fence achknowlegment online as they dont show a fence perrmit on file. This permit can not be released unitl that is done or the screen permit gets approved. Pool must be fully enclosed by fence (height/material/color as allowed by City Land Development Code) or screen enclosure. A baby fence does not meet the Land Development Code requirements. Please demonstrate the proposed fence meets Land Development Code requirements as per Chapter 4 of the Land Development Code. IF THERE IS TO BE A "FENCE BY OTHERS" THERE MUST BE A FENCE PERMIT (ACKNOWLEDGEMENT BY OWNER OF PROPERTY AS TO FENCE REQUIREMENTS) ON RECORD PRIOR TO ISSUANCE OF A POOL PERMIT. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| PLAN REVIEW - REVISION | ¤32.50 | 03/27/2026 |
| RSI FIELD SURVEY INSPECTION | ¤48.75 | 01/30/2026 |
| RSI PLAN REVIEW NEW | ¤48.75 | 01/30/2026 |
| RSI FNL SURVEY/GRADING CERT | ¤48.75 | 01/30/2026 |
| RSI ROW FINAL INSPECTION | ¤16.25 | 01/30/2026 |
| SURCHARGE FS 533.721 | ¤2.55 | 01/30/2026 |
| SURCHARGE - FS 468.631 | ¤3.83 | 01/30/2026 |
| SITE PLAN 30 | ¤30.00 | 01/30/2026 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 01/30/2026 |
| INSPECTION- POOL | ¤160.00 | 01/30/2026 |
| PLAN REVIEW - RESIDENTIAL | ¤65.00 | 01/30/2026 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤486.38 |