I want to search for...
Permit #2026010486
Permit Details
Status: INSPECT
| Parcel Id: 07-11-31-7025-00160-0090 |
| CONDITIONED SPACE: 1504 sqft |
| GARAGE: 396 sqft |
| OPENED PORCH (WITH ROOF) : 119 sqft |
| Total Square Footage: 2019 sqft |
| Block: 00160 |
| Subdivision: - |
| Job Phone: 407-476-8195 |
| Location Address: 192 PERSIMMON DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 02/10/2026 |
| NOC: RECORDED |
| Applicant name: CARLETTE RENE WITTE |
| Owner: INB BFS LAND LLC |
|
Address 7380 WEST SAND LAKE ROAD ORLANDO, FL 32819 |
|
Address SUITE 600 ORLANDO, FL 32819 |
| Lot: 0090 |
| Contracted Stated Job Value: ¤250,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
INNOVATIVE NATIONWIDE BUILDERS INC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3670 MAGUIRE BLVD #220 , |
CRC1330026 (Exp: 08/31/2026) | 855-694-6634 |
Sub Contractors
JASON LEE JAMES
| Status | Location Address | State License Number | Phone |
| ACTIVE |
217 N WESTMONTE DR SUITE 1007 ALTAMONTE SPRINGS, FL 32714 |
CAC1820196 (Exp: 08/31/2026) | 407-404-4000 |
ANTHONY OKEITH FENNELL
| Status | Location Address | State License Number | Phone |
| ACTIVE |
217 N. WESTMONTE DR, SUITE 1007 ALTAMONTE SPRINGS, FL 32714 |
EC13011194 (Exp: 08/31/2026) | 407-404-4000 |
HEATH EDWARD SANFORD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
126 EAST END RD SAN MATEO, FL 32187 |
CFC1429896 (Exp: 08/31/2026) | 386-871-8823 |
TERRY BRICE DICKERSON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4300 ST JOHN'S PARKWAY ALPHARETTA, GA 30009 |
CCC1326209 (Exp: 08/31/2026) | 407-548-6733 |
Inspection History
| Type | Request Date | Result | Inspector |
| ELECTRIC - EARLY POWER | 06/04/2026 | APPROVED | RMARTIN |
| Note: New inspection due to canceled inspection Inspector Notes from Inspection 2200 *** NOTES ADDED BY RSIMS 4/22/2026 1:37:41 PM *** 4/22/26: FPL emailed > Approved for TUG NOTE: Stucco/ Plaster style box will need to be installed to provide access to UFER ground (Located left of Main Meter Panel). | |||
| ELECTRIC - EARLY POWER | 06/03/2026 | CANCELLED BY APPLICANT | WEB |
| Note: Inspector Notes from Inspection 2200 *** NOTES ADDED BY RSIMS 4/22/2026 1:37:41 PM *** 4/22/26: FPL emailed > Approved for TUG NOTE: Stucco/ Plaster style box will need to be installed to provide access to UFER ground (Located left of Main Meter Panel). | |||
| DRYWALL NAILING | 05/12/2026 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 5/12/2026 10:08:51 AM *** Approved Inspector Notes from Inspection 2490 Inspector Notes from Inspection 2320 NOTE: Stucco/ Plaster style box will need to be installed to provide access to UFER ground (Located left of Main Meter Panel). 4/30/2026 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2420 2). 5ft. head pressure pipe needs to be filled to the top of the pipe. FBC-P2503.5.1 *This was not fixed from the Rough Inspection* *** NOTES ADDED BY RSIMS 4/24/2026 3:24:55 PM *** 4/24/26: Check at Insulation 1). Smoke detector at vaulted ceiling needs to be 4" vertically & within 36" horizontally from peak of vaulted ceiling. (roughly 21" to CL of box from peak measured parallel to bottom truss cord.) NFPA 70 - 29.11.3.1 2). 5ft. head pressure pipe needs to be filled to the top of the pipe. FBC-P2503.5.1 Inspector Notes from Inspection 2460 NOTE: Check previous notes from Inspection 2460 at Insulation also. *** NOTES ADDED BY RSIMS 4/21/2026 1:12:04 PM *** 4/21/26: Check at next inspection 1). Pony wall at entry is not built per detail WF95 as required on plan page S4.0. FBC [A]107.4 2). Please make sure that nails in multi-ply trusses are fully sunk. | |||
| INSULATION | 05/05/2026 | APPROVED - AS NOTED | HCAMACHO |
| Note: Inspector Notes from Inspection 2320 NOTE: Stucco/ Plaster style box will need to be installed to provide access to UFER ground (Located left of Main Meter Panel). 4/30/2026 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2420 2). 5ft. head pressure pipe needs to be filled to the top of the pipe. FBC-P2503.5.1 *This was not fixed from the Rough Inspection* *** NOTES ADDED BY RSIMS 4/24/2026 3:24:55 PM *** 4/24/26: Check at Insulation 1). Smoke detector at vaulted ceiling needs to be 4" vertically & within 36" horizontally from peak of vaulted ceiling. (roughly 21" to CL of box from peak measured parallel to bottom truss cord.) NFPA 70 - 29.11.3.1 2). 5ft. head pressure pipe needs to be filled to the top of the pipe. FBC-P2503.5.1 Inspector Notes from Inspection 2460 NOTE: Check previous notes from Inspection 2460 at Insulation also. *** NOTES ADDED BY RSIMS 4/21/2026 1:12:04 PM *** 4/21/26: Check at next inspection 1). Pony wall at entry is not built per detail WF95 as required on plan page S4.0. FBC [A]107.4 2). Please make sure that nails in multi-ply trusses are fully sunk. | |||
| LATH/BRICK/ WATER BARRIER | 05/04/2026 | APPROVED - AS NOTED | HCAMACHO |
| Note: NOTE: Stucco/ Plaster style box will need to be installed to provide access to UFER ground (Located left of Main Meter Panel). | |||
| INSULATION | 04/30/2026 | Disapproved - NO FEE | HCAMACHO |
| Note: Inspector Notes from Inspection 2420 2). 5ft. head pressure pipe needs to be filled to the top of the pipe. FBC-P2503.5.1 *This was not fixed from the Rough Inspection* *** NOTES ADDED BY RSIMS 4/24/2026 3:24:55 PM *** 4/24/26: Check at Insulation 1). Smoke detector at vaulted ceiling needs to be 4" vertically & within 36" horizontally from peak of vaulted ceiling. (roughly 21" to CL of box from peak measured parallel to bottom truss cord.) NFPA 70 - 29.11.3.1 2). 5ft. head pressure pipe needs to be filled to the top of the pipe. FBC-P2503.5.1 Inspector Notes from Inspection 2460 NOTE: Check previous notes from Inspection 2460 at Insulation also. *** NOTES ADDED BY RSIMS 4/21/2026 1:12:04 PM *** 4/21/26: Check at next inspection 1). Pony wall at entry is not built per detail WF95 as required on plan page S4.0. FBC [A]107.4 2). Please make sure that nails in multi-ply trusses are fully sunk. | |||
| ALL ROUGH | 04/24/2026 | APPROVED - AS NOTED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 4/24/2026 3:24:55 PM *** 4/24/26: Check at Insulation 1). Smoke detector at vaulted ceiling needs to be 4" vertically & within 36" horizontally from peak of vaulted ceiling. (roughly 21" to CL of box from peak measured parallel to bottom truss cord.) NFPA 70 - 29.11.3.1 2). 5ft. head pressure pipe needs to be filled to the top of the pipe. FBC-P2503.5.1 Inspector Notes from Inspection 2460 NOTE: Check previous notes from Inspection 2460 at Insulation also. *** NOTES ADDED BY RSIMS 4/21/2026 1:12:04 PM *** 4/21/26: Check at next inspection 1). Pony wall at entry is not built per detail WF95 as required on plan page S4.0. FBC [A]107.4 2). Please make sure that nails in multi-ply trusses are fully sunk. | |||
| SEWER TIE IN | 04/24/2026 | APPROVED - AS NOTED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 4/24/2026 3:16:57 PM *** 4/24/26: Approved as noted pending Utility Department approval of the single 6" lateral feeding two seperate properties through a double 6" wye. 4/21/2026 - PREVIOUS INSPECTION NOTES 4/21/26: 1). Connection to the Main sewer lateral needs to be uncovered and fully visible for inspection. FBC-P2503.4 | |||
| ELECTRIC-TUG | 04/22/2026 | APPROVED - AS NOTED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 4/22/2026 1:37:41 PM *** 4/22/26: FPL emailed > Approved for TUG NOTE: Stucco/ Plaster style box will need to be installed to provide access to UFER ground (Located left of Main Meter Panel). | |||
| SEWER TIE IN | 04/21/2026 | Disapproved - NO FEE | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 4/21/2026 1:05:15 PM *** 4/21/26: 1). Connection to the Main sewer lateral needs to be uncovered and fully visible for inspection. FBC-P2503.4 | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 04/21/2026 | APPROVED - AS NOTED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 4/21/2026 1:12:04 PM *** 4/21/26: Check at next inspection 1). Pony wall at entry is not built per detail WF95 as required on plan page S4.0. FBC [A]107.4 2). Please make sure that nails in multi-ply trusses are fully sunk. | |||
| ROOF VALLEY & METAL | 04/16/2026 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 4/16/2026 9:00:42 AM *** Approved Inspector Notes from Inspection 2465 *** NOTES ADDED BY RSIMS 4/9/2026 11:44:43 AM *** 4/9/26: NOTE: Pull shiner prior to covering with underlayment. | |||
| WALL SHEATHING | 04/16/2026 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 4/16/2026 9:01:35 AM *** Approved Inspector Notes from Inspection 2465 *** NOTES ADDED BY RSIMS 4/9/2026 11:44:43 AM *** 4/9/26: NOTE: Pull shiner prior to covering with underlayment. | |||
| GRAVITY SEWER TEST | 04/16/2026 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 4/16/2026 9:02:25 AM *** Approved | |||
| ROOF SHEATHING | 04/09/2026 | APPROVED - AS NOTED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 4/9/2026 11:44:43 AM *** 4/9/26: NOTE: Pull shiner prior to covering with underlayment. | |||
| TIE BEAM / LINTEL | 03/31/2026 | APPROVED | HCAMACHO |
| MONOLITHIC SLAB | 03/24/2026 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 3/24/2026 11:08:02 AM *** Approved | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 03/20/2026 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 3/20/2026 12:39:09 PM *** 3/20/26: Main underground water service piping is installed from house to the meter (meter is installed). Inspected and approved. | |||
| FORMBOARD SURVEY (OFFICE USE ONLY) | 03/19/2026 | APPROVED | RRICKS |
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | 03/19/2026 | APPROVED | PKNAPIK |
| WATER METER INSTALLATION REQUEST | 03/04/2026 | APPROVED | ISANDERSON |
| U-CROSS CONNECTION | |||
| ROW- PRE-APRON (PRE-POUR) | |||
| ROW - FINAL APRON (AFTER POUR) | |||
| ROW - FINAL INSPECTION | |||
| U -UTILITY RESIDENTIAL FINAL | |||
| BLD - BUILDING FINAL |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 04/17/2026 | 04/20/2026 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 03/19/2026 | 03/19/2026 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 03/19/2026 | 03/19/2026 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 03/19/2026 | 03/19/2026 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| BADMIN | INFORMATION | 02/05/2026 | 02/05/2026 |
| Note: Marked INFORMATION By: JAZMIN ROSARIO - - JROSARIO@PALMCOASTGOV.COM RENAME FILE TO MATCH DOCUMENT TYPE BEING UPLOADED. EX: NOC = NOC | |||
| SW1 | COMPLETE | 01/28/2026 | 01/28/2026 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Approved as noted: Lot 11 is vacant and lot 12 is improved. Based on survey data, there are no issues with FFE in the future. | |||
| SWALE | COMPLETE | 01/20/2026 | 01/27/2026 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 01/16/2026 | 01/23/2026 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 01/16/2026 | 01/23/2026 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 01/16/2026 | 01/22/2026 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 01/16/2026 | 01/20/2026 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 01/16/2026 | 01/20/2026 |
| LOCATE | COMPLETE | 01/16/2026 | 01/22/2026 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 01/16/2026 | 01/21/2026 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 01/16/2026 | 01/26/2026 |
| Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Based on the information from our survey team, lot 11 is vacant and lot 12 is the improved lot. Please confirm this and provide FFE of this improved lot. | |||
| ZON | COMPLETE | 01/16/2026 | 01/16/2026 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM Please correct the number of crepe myrtle trees on the landscape plan. The legend shows 6 however there are only 4 drawn on the plan itself. A/C pad is not in the same location on the floor plan as it is on the site plan and landscpae plans. Please correct whichever is wrong. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| WATER- TURN ON | ¤50.00 | 02/10/2026 |
| INSPECTION - RESIDENTIAL | ¤805.75 | 02/10/2026 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 02/10/2026 |
| PLAN REVIEW - RESIDENTIAL | ¤228.54 | 02/10/2026 |
| FC IMPACT FEE EMS | ¤62.00 | 02/10/2026 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 02/10/2026 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 02/10/2026 |
| FIRE RES IMPACT FEE 10-25 | ¤942.00 | 02/10/2026 |
| PARKS IMPACT FEE 10-25 | ¤3,164.00 | 02/10/2026 |
| RSE DRIVE PRE POUR INSPECTION | ¤32.50 | 02/10/2026 |
| RSI DRIVEWAY AFTER POUR | ¤16.25 | 02/10/2026 |
| RSI FIELD SURVEY INSPECTION | ¤48.75 | 02/10/2026 |
| RSI FORMBOARD REVIEW | ¤16.25 | 02/10/2026 |
| RSI FNL SURVEY/GRADING CERT | ¤48.75 | 02/10/2026 |
| RSI PLAN REVIEW NEW | ¤48.75 | 02/10/2026 |
| RSI ROW FINAL INSPECTION | ¤16.25 | 02/10/2026 |
| WASTEWATER MAIN EXTENSION IMPA | ¤2,385.00 | 02/10/2026 |
| SCHOOL BOARD IMPACT FEE RES | ¤5,450.00 | 02/10/2026 |
| SURCHARGE FS 533.721 | ¤10.64 | 02/10/2026 |
| SURCHARGE - FS 468.631 | ¤15.96 | 02/10/2026 |
| SW ENG RES REVIEW 240 | ¤240.00 | 02/10/2026 |
| WATER METER W/ TAP | ¤2,326.93 | 02/10/2026 |
| TRANSP RES IMPACT FEE 10-25 | ¤5,670.08 | 02/10/2026 |
| SEWER CREDIT | (¤850.00) | 02/10/2026 |
| WASTEWATER PERM INSPECTION | ¤80.00 | 02/10/2026 |
| WASTEWATER PERM REVIEW | ¤25.00 | 02/10/2026 |
| WATER CAPITAL FACILITY FEE | ¤3,790.49 | 02/10/2026 |
| SEWER CAPITAL FACILITY | ¤4,415.00 | 02/10/2026 |
| WATER PERMIT REVIEW | ¤25.00 | 02/10/2026 |
| WATER MAIN EXTENSION IMPACT | ¤917.27 | 02/10/2026 |
| SITE PLAN 30 | ¤30.00 | 02/10/2026 |
| SITE PLAN 30 | ¤30.00 | 02/05/2026 |
| SITE PLAN 30 | (¤30.00) | 02/05/2026 |
| WATER MAIN EXTENSION IMPACT | ¤917.27 | 02/05/2026 |
| WATER MAIN EXTENSION IMPACT | (¤917.27) | 02/05/2026 |
| SEWER CAPITAL FACILITY | ¤4,415.00 | 02/05/2026 |
| WATER CAPITAL FACILITY FEE | (¤3,790.49) | 02/05/2026 |
| WATER CAPITAL FACILITY FEE | ¤3,790.49 | 02/05/2026 |
| WATER PERMIT REVIEW | ¤25.00 | 02/05/2026 |
| WATER PERMIT REVIEW | (¤25.00) | 02/05/2026 |
| WASTEWATER PERM REVIEW | ¤25.00 | 02/05/2026 |
| SEWER CAPITAL FACILITY | (¤4,415.00) | 02/05/2026 |
| WASTEWATER PERM REVIEW | (¤25.00) | 02/05/2026 |
| WASTEWATER PERM INSPECTION | ¤80.00 | 02/05/2026 |
| WASTEWATER PERM INSPECTION | (¤80.00) | 02/05/2026 |
| SEWER CREDIT | (¤850.00) | 02/05/2026 |
| SEWER CREDIT | ¤850.00 | 02/05/2026 |
| TRANSP RES IMPACT FEE 10-25 | ¤5,670.08 | 02/05/2026 |
| TRANSP RES IMPACT FEE 10-25 | (¤5,670.08) | 02/05/2026 |
| WATER METER W/ TAP | ¤2,326.93 | 02/05/2026 |
| WATER METER W/ TAP | (¤2,326.93) | 02/05/2026 |
| SURCHARGE - FS 468.631 | ¤15.96 | 02/05/2026 |
| SW ENG RES REVIEW 240 | ¤240.00 | 02/05/2026 |
| SW ENG RES REVIEW 240 | (¤240.00) | 02/05/2026 |
| SURCHARGE - FS 468.631 | (¤15.96) | 02/05/2026 |
| SCHOOL BOARD IMPACT FEE RES | ¤5,450.00 | 02/05/2026 |
| WASTEWATER MAIN EXTENSION IMPA | (¤2,385.00) | 02/05/2026 |
| WASTEWATER MAIN EXTENSION IMPA | ¤2,385.00 | 02/05/2026 |
| SURCHARGE FS 533.721 | ¤10.64 | 02/05/2026 |
| SURCHARGE FS 533.721 | (¤10.64) | 02/05/2026 |
| SCHOOL BOARD IMPACT FEE RES | (¤5,450.00) | 02/05/2026 |
| RSI FNL SURVEY/GRADING CERT | (¤48.75) | 02/05/2026 |
| RSI FNL SURVEY/GRADING CERT | ¤48.75 | 02/05/2026 |
| RSI ROW FINAL INSPECTION | ¤16.25 | 02/05/2026 |
| RSI ROW FINAL INSPECTION | (¤16.25) | 02/05/2026 |
| RSI FORMBOARD REVIEW | ¤16.25 | 02/05/2026 |
| RSI PLAN REVIEW NEW | ¤48.75 | 02/05/2026 |
| RSI PLAN REVIEW NEW | (¤48.75) | 02/05/2026 |
| RSI FORMBOARD REVIEW | (¤16.25) | 02/05/2026 |
| RSE DRIVE PRE POUR INSPECTION | (¤32.50) | 02/05/2026 |
| RSE DRIVE PRE POUR INSPECTION | ¤32.50 | 02/05/2026 |
| RSI FIELD SURVEY INSPECTION | ¤48.75 | 02/05/2026 |
| RSI FIELD SURVEY INSPECTION | (¤48.75) | 02/05/2026 |
| PARKS IMPACT FEE 10-25 | ¤3,164.00 | 02/05/2026 |
| RSI DRIVEWAY AFTER POUR | ¤16.25 | 02/05/2026 |
| RSI DRIVEWAY AFTER POUR | (¤16.25) | 02/05/2026 |
| PARKS IMPACT FEE 10-25 | (¤3,164.00) | 02/05/2026 |
| FC IMPACT FEE LIBRARY | (¤268.00) | 02/05/2026 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 02/05/2026 |
| FIRE RES IMPACT FEE 10-25 | ¤942.00 | 02/05/2026 |
| FIRE RES IMPACT FEE 10-25 | (¤942.00) | 02/05/2026 |
| FC IMPACT FEE EMS | ¤62.00 | 02/05/2026 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 02/05/2026 |
| FC IMPACT FEE LAW ENFORCEMENT | (¤218.00) | 02/05/2026 |
| FC IMPACT FEE EMS | (¤62.00) | 02/05/2026 |
| INSPECTION - RESIDENTIAL | (¤805.75) | 02/05/2026 |
| INSPECTION - RESIDENTIAL | ¤805.75 | 02/05/2026 |
| PLAN REVIEW - RESIDENTIAL | ¤228.54 | 02/05/2026 |
| PLAN REVIEW - RESIDENTIAL | (¤228.54) | 02/05/2026 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 02/05/2026 |
| ADMINISTRATIVE RESIDENTIAL | (¤30.00) | 02/05/2026 |
| WATER- TURN ON | ¤50.00 | 02/05/2026 |
| WATER- TURN ON | (¤50.00) | 02/05/2026 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤30,527.16 |