Permit #2026010486

Permit Details

Status: INSPECT

Parcel Id: 07-11-31-7025-00160-0090
CONDITIONED SPACE: 1504 sqft
GARAGE: 396 sqft
OPENED PORCH (WITH ROOF) : 119 sqft
Total Square Footage: 2019 sqft
Block: 00160
Subdivision: -
Job Phone: 407-476-8195
Location Address: 192 PERSIMMON DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 02/10/2026
NOC: RECORDED
Applicant name: CARLETTE RENE WITTE
Owner: INB BFS LAND LLC

Address

7380 WEST SAND LAKE ROAD

ORLANDO, FL 32819

Address

SUITE 600

ORLANDO, FL 32819

Lot: 0090
Contracted Stated Job Value: ¤250,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

INNOVATIVE NATIONWIDE BUILDERS INC
Status Location Address State License Number Phone
ACTIVE

3670 MAGUIRE BLVD #220

,

CRC1330026 (Exp: 08/31/2026) 855-694-6634

Sub Contractors

JASON LEE JAMES
Status Location Address State License Number Phone
ACTIVE

217 N WESTMONTE DR SUITE 1007

ALTAMONTE SPRINGS, FL 32714

CAC1820196 (Exp: 08/31/2026) 407-404-4000
ANTHONY OKEITH FENNELL
Status Location Address State License Number Phone
ACTIVE

217 N. WESTMONTE DR, SUITE 1007

ALTAMONTE SPRINGS, FL 32714

EC13011194 (Exp: 08/31/2026) 407-404-4000
HEATH EDWARD SANFORD
Status Location Address State License Number Phone
ACTIVE

126 EAST END RD

SAN MATEO, FL 32187

CFC1429896 (Exp: 08/31/2026) 386-871-8823
TERRY BRICE DICKERSON
Status Location Address State License Number Phone
ACTIVE

4300 ST JOHN'S PARKWAY

ALPHARETTA, GA 30009

CCC1326209 (Exp: 08/31/2026) 407-548-6733

Inspection History

Type Request Date Result Inspector
ELECTRIC - EARLY POWER 06/04/2026 APPROVED RMARTIN
Note: New inspection due to canceled inspection Inspector Notes from Inspection 2200 *** NOTES ADDED BY RSIMS 4/22/2026 1:37:41 PM *** 4/22/26: FPL emailed > Approved for TUG NOTE: Stucco/ Plaster style box will need to be installed to provide access to UFER ground (Located left of Main Meter Panel).
ELECTRIC - EARLY POWER 06/03/2026 CANCELLED BY APPLICANT WEB
Note: Inspector Notes from Inspection 2200 *** NOTES ADDED BY RSIMS 4/22/2026 1:37:41 PM *** 4/22/26: FPL emailed > Approved for TUG NOTE: Stucco/ Plaster style box will need to be installed to provide access to UFER ground (Located left of Main Meter Panel).
DRYWALL NAILING 05/12/2026 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 5/12/2026 10:08:51 AM *** Approved Inspector Notes from Inspection 2490 Inspector Notes from Inspection 2320 NOTE: Stucco/ Plaster style box will need to be installed to provide access to UFER ground (Located left of Main Meter Panel). 4/30/2026 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2420 2). 5ft. head pressure pipe needs to be filled to the top of the pipe. FBC-P2503.5.1 *This was not fixed from the Rough Inspection* *** NOTES ADDED BY RSIMS 4/24/2026 3:24:55 PM *** 4/24/26: Check at Insulation 1). Smoke detector at vaulted ceiling needs to be 4" vertically & within 36" horizontally from peak of vaulted ceiling. (roughly 21" to CL of box from peak measured parallel to bottom truss cord.) NFPA 70 - 29.11.3.1 2). 5ft. head pressure pipe needs to be filled to the top of the pipe. FBC-P2503.5.1 Inspector Notes from Inspection 2460 NOTE: Check previous notes from Inspection 2460 at Insulation also. *** NOTES ADDED BY RSIMS 4/21/2026 1:12:04 PM *** 4/21/26: Check at next inspection 1). Pony wall at entry is not built per detail WF95 as required on plan page S4.0. FBC [A]107.4 2). Please make sure that nails in multi-ply trusses are fully sunk.
INSULATION 05/05/2026 APPROVED - AS NOTED HCAMACHO
Note: Inspector Notes from Inspection 2320 NOTE: Stucco/ Plaster style box will need to be installed to provide access to UFER ground (Located left of Main Meter Panel). 4/30/2026 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2420 2). 5ft. head pressure pipe needs to be filled to the top of the pipe. FBC-P2503.5.1 *This was not fixed from the Rough Inspection* *** NOTES ADDED BY RSIMS 4/24/2026 3:24:55 PM *** 4/24/26: Check at Insulation 1). Smoke detector at vaulted ceiling needs to be 4" vertically & within 36" horizontally from peak of vaulted ceiling. (roughly 21" to CL of box from peak measured parallel to bottom truss cord.) NFPA 70 - 29.11.3.1 2). 5ft. head pressure pipe needs to be filled to the top of the pipe. FBC-P2503.5.1 Inspector Notes from Inspection 2460 NOTE: Check previous notes from Inspection 2460 at Insulation also. *** NOTES ADDED BY RSIMS 4/21/2026 1:12:04 PM *** 4/21/26: Check at next inspection 1). Pony wall at entry is not built per detail WF95 as required on plan page S4.0. FBC [A]107.4 2). Please make sure that nails in multi-ply trusses are fully sunk.
LATH/BRICK/ WATER BARRIER 05/04/2026 APPROVED - AS NOTED HCAMACHO
Note: NOTE: Stucco/ Plaster style box will need to be installed to provide access to UFER ground (Located left of Main Meter Panel).
INSULATION 04/30/2026 Disapproved - NO FEE HCAMACHO
Note: Inspector Notes from Inspection 2420 2). 5ft. head pressure pipe needs to be filled to the top of the pipe. FBC-P2503.5.1 *This was not fixed from the Rough Inspection* *** NOTES ADDED BY RSIMS 4/24/2026 3:24:55 PM *** 4/24/26: Check at Insulation 1). Smoke detector at vaulted ceiling needs to be 4" vertically & within 36" horizontally from peak of vaulted ceiling. (roughly 21" to CL of box from peak measured parallel to bottom truss cord.) NFPA 70 - 29.11.3.1 2). 5ft. head pressure pipe needs to be filled to the top of the pipe. FBC-P2503.5.1 Inspector Notes from Inspection 2460 NOTE: Check previous notes from Inspection 2460 at Insulation also. *** NOTES ADDED BY RSIMS 4/21/2026 1:12:04 PM *** 4/21/26: Check at next inspection 1). Pony wall at entry is not built per detail WF95 as required on plan page S4.0. FBC [A]107.4 2). Please make sure that nails in multi-ply trusses are fully sunk.
ALL ROUGH 04/24/2026 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 4/24/2026 3:24:55 PM *** 4/24/26: Check at Insulation 1). Smoke detector at vaulted ceiling needs to be 4" vertically & within 36" horizontally from peak of vaulted ceiling. (roughly 21" to CL of box from peak measured parallel to bottom truss cord.) NFPA 70 - 29.11.3.1 2). 5ft. head pressure pipe needs to be filled to the top of the pipe. FBC-P2503.5.1 Inspector Notes from Inspection 2460 NOTE: Check previous notes from Inspection 2460 at Insulation also. *** NOTES ADDED BY RSIMS 4/21/2026 1:12:04 PM *** 4/21/26: Check at next inspection 1). Pony wall at entry is not built per detail WF95 as required on plan page S4.0. FBC [A]107.4 2). Please make sure that nails in multi-ply trusses are fully sunk.
SEWER TIE IN 04/24/2026 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 4/24/2026 3:16:57 PM *** 4/24/26: Approved as noted pending Utility Department approval of the single 6" lateral feeding two seperate properties through a double 6" wye. 4/21/2026 - PREVIOUS INSPECTION NOTES 4/21/26: 1). Connection to the Main sewer lateral needs to be uncovered and fully visible for inspection. FBC-P2503.4
ELECTRIC-TUG 04/22/2026 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 4/22/2026 1:37:41 PM *** 4/22/26: FPL emailed > Approved for TUG NOTE: Stucco/ Plaster style box will need to be installed to provide access to UFER ground (Located left of Main Meter Panel).
SEWER TIE IN 04/21/2026 Disapproved - NO FEE RSIMS
Note: *** NOTES ADDED BY RSIMS 4/21/2026 1:05:15 PM *** 4/21/26: 1). Connection to the Main sewer lateral needs to be uncovered and fully visible for inspection. FBC-P2503.4
ROOF SHEATHING / BRACES/TIES/DOWN CELL 04/21/2026 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 4/21/2026 1:12:04 PM *** 4/21/26: Check at next inspection 1). Pony wall at entry is not built per detail WF95 as required on plan page S4.0. FBC [A]107.4 2). Please make sure that nails in multi-ply trusses are fully sunk.
ROOF VALLEY & METAL 04/16/2026 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 4/16/2026 9:00:42 AM *** Approved Inspector Notes from Inspection 2465 *** NOTES ADDED BY RSIMS 4/9/2026 11:44:43 AM *** 4/9/26: NOTE: Pull shiner prior to covering with underlayment.
WALL SHEATHING 04/16/2026 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 4/16/2026 9:01:35 AM *** Approved Inspector Notes from Inspection 2465 *** NOTES ADDED BY RSIMS 4/9/2026 11:44:43 AM *** 4/9/26: NOTE: Pull shiner prior to covering with underlayment.
GRAVITY SEWER TEST 04/16/2026 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 4/16/2026 9:02:25 AM *** Approved
ROOF SHEATHING 04/09/2026 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 4/9/2026 11:44:43 AM *** 4/9/26: NOTE: Pull shiner prior to covering with underlayment.
TIE BEAM / LINTEL 03/31/2026 APPROVED HCAMACHO
MONOLITHIC SLAB 03/24/2026 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 3/24/2026 11:08:02 AM *** Approved
PLUMBING 1ST ROUGH UNDERGROUND 03/20/2026 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 3/20/2026 12:39:09 PM *** 3/20/26: Main underground water service piping is installed from house to the meter (meter is installed). Inspected and approved.
FORMBOARD SURVEY (OFFICE USE ONLY) 03/19/2026 APPROVED RRICKS
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 03/19/2026 APPROVED PKNAPIK
WATER METER INSTALLATION REQUEST 03/04/2026 APPROVED ISANDERSON
U-CROSS CONNECTION
ROW- PRE-APRON (PRE-POUR)
ROW - FINAL APRON (AFTER POUR)
ROW - FINAL INSPECTION
U -UTILITY RESIDENTIAL FINAL
BLD - BUILDING FINAL

Review History

Department Status Date In Date Out
BLD COMPLETE 04/17/2026 04/20/2026
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
SW1 COMPLETE 03/19/2026 03/19/2026
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 03/19/2026 03/19/2026
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
BLD COMPLETE 03/19/2026 03/19/2026
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
BADMIN INFORMATION 02/05/2026 02/05/2026
Note: Marked INFORMATION By: JAZMIN ROSARIO - - JROSARIO@PALMCOASTGOV.COM RENAME FILE TO MATCH DOCUMENT TYPE BEING UPLOADED. EX: NOC = NOC
SW1 COMPLETE 01/28/2026 01/28/2026
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Approved as noted: Lot 11 is vacant and lot 12 is improved. Based on survey data, there are no issues with FFE in the future.
SWALE COMPLETE 01/20/2026 01/27/2026
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
BLD COMPLETE 01/16/2026 01/23/2026
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
CUSVC COMPLETE 01/16/2026 01/23/2026
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 01/16/2026 01/22/2026
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 01/16/2026 01/20/2026
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
GAS CANCEL 01/16/2026 01/20/2026
LOCATE COMPLETE 01/16/2026 01/22/2026
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH COMPLETE 01/16/2026 01/21/2026
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 HOLD 01/16/2026 01/26/2026
Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Based on the information from our survey team, lot 11 is vacant and lot 12 is the improved lot. Please confirm this and provide FFE of this improved lot.
ZON COMPLETE 01/16/2026 01/16/2026
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM Please correct the number of crepe myrtle trees on the landscape plan. The legend shows 6 however there are only 4 drawn on the plan itself. A/C pad is not in the same location on the floor plan as it is on the site plan and landscpae plans. Please correct whichever is wrong.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
WATER- TURN ON ¤50.00 02/10/2026
INSPECTION - RESIDENTIAL ¤805.75 02/10/2026
ADMINISTRATIVE RESIDENTIAL ¤30.00 02/10/2026
PLAN REVIEW - RESIDENTIAL ¤228.54 02/10/2026
FC IMPACT FEE EMS ¤62.00 02/10/2026
FC IMPACT FEE LIBRARY ¤268.00 02/10/2026
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 02/10/2026
FIRE RES IMPACT FEE 10-25 ¤942.00 02/10/2026
PARKS IMPACT FEE 10-25 ¤3,164.00 02/10/2026
RSE DRIVE PRE POUR INSPECTION ¤32.50 02/10/2026
RSI DRIVEWAY AFTER POUR ¤16.25 02/10/2026
RSI FIELD SURVEY INSPECTION ¤48.75 02/10/2026
RSI FORMBOARD REVIEW ¤16.25 02/10/2026
RSI FNL SURVEY/GRADING CERT ¤48.75 02/10/2026
RSI PLAN REVIEW NEW ¤48.75 02/10/2026
RSI ROW FINAL INSPECTION ¤16.25 02/10/2026
WASTEWATER MAIN EXTENSION IMPA ¤2,385.00 02/10/2026
SCHOOL BOARD IMPACT FEE RES ¤5,450.00 02/10/2026
SURCHARGE FS 533.721 ¤10.64 02/10/2026
SURCHARGE - FS 468.631 ¤15.96 02/10/2026
SW ENG RES REVIEW 240 ¤240.00 02/10/2026
WATER METER W/ TAP ¤2,326.93 02/10/2026
TRANSP RES IMPACT FEE 10-25 ¤5,670.08 02/10/2026
SEWER CREDIT (¤850.00) 02/10/2026
WASTEWATER PERM INSPECTION ¤80.00 02/10/2026
WASTEWATER PERM REVIEW ¤25.00 02/10/2026
WATER CAPITAL FACILITY FEE ¤3,790.49 02/10/2026
SEWER CAPITAL FACILITY ¤4,415.00 02/10/2026
WATER PERMIT REVIEW ¤25.00 02/10/2026
WATER MAIN EXTENSION IMPACT ¤917.27 02/10/2026
SITE PLAN 30 ¤30.00 02/10/2026
SITE PLAN 30 ¤30.00 02/05/2026
SITE PLAN 30 (¤30.00) 02/05/2026
WATER MAIN EXTENSION IMPACT ¤917.27 02/05/2026
WATER MAIN EXTENSION IMPACT (¤917.27) 02/05/2026
SEWER CAPITAL FACILITY ¤4,415.00 02/05/2026
WATER CAPITAL FACILITY FEE (¤3,790.49) 02/05/2026
WATER CAPITAL FACILITY FEE ¤3,790.49 02/05/2026
WATER PERMIT REVIEW ¤25.00 02/05/2026
WATER PERMIT REVIEW (¤25.00) 02/05/2026
WASTEWATER PERM REVIEW ¤25.00 02/05/2026
SEWER CAPITAL FACILITY (¤4,415.00) 02/05/2026
WASTEWATER PERM REVIEW (¤25.00) 02/05/2026
WASTEWATER PERM INSPECTION ¤80.00 02/05/2026
WASTEWATER PERM INSPECTION (¤80.00) 02/05/2026
SEWER CREDIT (¤850.00) 02/05/2026
SEWER CREDIT ¤850.00 02/05/2026
TRANSP RES IMPACT FEE 10-25 ¤5,670.08 02/05/2026
TRANSP RES IMPACT FEE 10-25 (¤5,670.08) 02/05/2026
WATER METER W/ TAP ¤2,326.93 02/05/2026
WATER METER W/ TAP (¤2,326.93) 02/05/2026
SURCHARGE - FS 468.631 ¤15.96 02/05/2026
SW ENG RES REVIEW 240 ¤240.00 02/05/2026
SW ENG RES REVIEW 240 (¤240.00) 02/05/2026
SURCHARGE - FS 468.631 (¤15.96) 02/05/2026
SCHOOL BOARD IMPACT FEE RES ¤5,450.00 02/05/2026
WASTEWATER MAIN EXTENSION IMPA (¤2,385.00) 02/05/2026
WASTEWATER MAIN EXTENSION IMPA ¤2,385.00 02/05/2026
SURCHARGE FS 533.721 ¤10.64 02/05/2026
SURCHARGE FS 533.721 (¤10.64) 02/05/2026
SCHOOL BOARD IMPACT FEE RES (¤5,450.00) 02/05/2026
RSI FNL SURVEY/GRADING CERT (¤48.75) 02/05/2026
RSI FNL SURVEY/GRADING CERT ¤48.75 02/05/2026
RSI ROW FINAL INSPECTION ¤16.25 02/05/2026
RSI ROW FINAL INSPECTION (¤16.25) 02/05/2026
RSI FORMBOARD REVIEW ¤16.25 02/05/2026
RSI PLAN REVIEW NEW ¤48.75 02/05/2026
RSI PLAN REVIEW NEW (¤48.75) 02/05/2026
RSI FORMBOARD REVIEW (¤16.25) 02/05/2026
RSE DRIVE PRE POUR INSPECTION (¤32.50) 02/05/2026
RSE DRIVE PRE POUR INSPECTION ¤32.50 02/05/2026
RSI FIELD SURVEY INSPECTION ¤48.75 02/05/2026
RSI FIELD SURVEY INSPECTION (¤48.75) 02/05/2026
PARKS IMPACT FEE 10-25 ¤3,164.00 02/05/2026
RSI DRIVEWAY AFTER POUR ¤16.25 02/05/2026
RSI DRIVEWAY AFTER POUR (¤16.25) 02/05/2026
PARKS IMPACT FEE 10-25 (¤3,164.00) 02/05/2026
FC IMPACT FEE LIBRARY (¤268.00) 02/05/2026
FC IMPACT FEE LIBRARY ¤268.00 02/05/2026
FIRE RES IMPACT FEE 10-25 ¤942.00 02/05/2026
FIRE RES IMPACT FEE 10-25 (¤942.00) 02/05/2026
FC IMPACT FEE EMS ¤62.00 02/05/2026
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 02/05/2026
FC IMPACT FEE LAW ENFORCEMENT (¤218.00) 02/05/2026
FC IMPACT FEE EMS (¤62.00) 02/05/2026
INSPECTION - RESIDENTIAL (¤805.75) 02/05/2026
INSPECTION - RESIDENTIAL ¤805.75 02/05/2026
PLAN REVIEW - RESIDENTIAL ¤228.54 02/05/2026
PLAN REVIEW - RESIDENTIAL (¤228.54) 02/05/2026
ADMINISTRATIVE RESIDENTIAL ¤30.00 02/05/2026
ADMINISTRATIVE RESIDENTIAL (¤30.00) 02/05/2026
WATER- TURN ON ¤50.00 02/05/2026
WATER- TURN ON (¤50.00) 02/05/2026
Fees Total Due: ¤0.00 Total Paid: ¤30,527.16