Permit #2026010560
Permit Details
Status: COED
| Parcel Id: 04-11-30-5571-00000-1790 |
| CONDITIONED SPACE: 1221 sqft |
| GARAGE: 420 sqft |
| OPENED PORCH (WITH ROOF) : 31 sqft |
| Total Square Footage: 1672 sqft |
| Subdivision: 2366 - SOMERSET SUBDIVISION PH 2 |
| Job Phone: 904-596-6645 |
| Location Address: 104 TEA OLIVE DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 01/30/2026 |
| NOC: RECORDED |
| Applicant name: MICHAEL T HOLDER |
| Owner: KB HOME JACKSONVILLE LLC |
|
Address 10475 FORTUNE PARKWAY JACKSONVILLE, FL 32256 |
|
Address SUITE 100 JACKSONVILLE, FL 32256 |
| Lot: 179 |
| Contracted Stated Job Value: ¤140,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
KB HOME JACKSONVILLE, LLC
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
10475 FORTUNE PKWY JACKSONVILLE, FL 32256 |
SUITE 100 JACKSONVILLE, FL 32256 |
CGC1509034 (Exp: 08/31/2026) | 904-596-6645 |
Sub Contractors
BOBBY WAYNE CAMPBELL
| Status | Location Address | State License Number | Phone |
| ACTIVE |
117 GUTHRIE ROAD GREEN COVE SPRINGS, FL 32043 |
CCC1326752 (Exp: 08/31/2026) | 904-200-1600 |
LARRY WILLIAMS
| Status | Location Address | State License Number | Phone |
| ACTIVE |
1750 EMERSON ST JACKSONVILLE, FL 32207 |
LI45034 (Exp: 08/31/2026) | 904-721-5431 |
JAMES E LINTON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
200 COLLEGE DR ORANGE PARK, FL 32065 |
EC0001152 (Exp: 08/31/2026) | 904-272-0272 |
COREY MICHAEL TENNANT
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3370 AGRICULTURAL CNETER DR ST AUGUSTINE, FL 32092 |
CAC1819063 (Exp: 08/31/2026) | 904-829-8898 |
BENJAMIN MICHAEL RAY
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| ACTIVE |
6310 MABLETON PKWY JACKSONVILLE, FL 32216 |
SUITE 1000 MABLETON, GA 30126 |
CFC1428415 (Exp: 08/31/2026) | 904-861-5421 | 904-861-5426 |
Inspection History
| Type | Request Date | Result | Inspector |
| ROW - FINAL APRON (AFTER POUR) | 05/07/2026 | APPROVED | EMADISON |
| Note: ** AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW - FINAL INSPECTION | 05/07/2026 | APPROVED | EMADISON |
| Note: ** AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| U -UTILITY RESIDENTIAL FINAL | 05/07/2026 | APPROVED | BVEIGA |
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 05/06/2026 | APPROVED | TPOLACEK |
| Note: BASED ON THE ENGINEERS SIGNED AND SEALED LGDC MEETING THE COPC MINIMUM REQUIREMENTS AT THE TIME OF THIS INSPECTION, I AM APPROVING THIS DOCUMENT. Effective 03-25-26, the ROW Field Survey requirement is no longer in effect for Final Lot Grading and Drainage Certificates for new construction on subdivision and infill lots. All Final Lot Grading and Drainage Certificates for these projects will now be reviewed and approved only in the office. Field verification for the ROW-FIELD SURVEY will no longer be required as part of the standard approval process for these permit types | |||
| BLD - BUILDING FINAL | 05/06/2026 | FINAL APPROVED | JSTEWART |
| Note: 4/24/2026 - PREVIOUS INSPECTION NOTES 1. Please seal exterior wall at irrigation conduit penetration. FBC EC TABLE R402.4.1.1 2. Remove wood shims at underground power conduit (Termite). FBCR 317.1.2 3. Secure conduit to wall at receptacle under main disconnect. NEC 352.30(A) 4. Label Main disconnect breakers. NEC 408.4 5. Please seal siding at communication conduit penetration. FBC EC TABLE R402.4.1.1 6. Roof Exhaust terminations require a screen (except dryer). FBC R303.6 7. No Hot water in the building (will require directional inspection hot on left at fixtures) 8. Master Lav on left has no water preassure when fixture is turned to the left. 9. Please seal hole in wall inside AHU closet. FBC EC TABLE R402.4.1.1 10. Garage door opener needs to be powered on for saftey device test. UL 325/FBCR 309.4 | |||
| BLD - BUILDING FINAL | 04/24/2026 | Disapproved -FEE REQUIRED | JSTEWART |
| Note: 1. Please seal exterior wall at irrigation conduit penetration. FBC EC TABLE R402.4.1.1 2. Remove wood shims at underground power conduit (Termite). FBCR 317.1.2 3. Secure conduit to wall at receptacle under main disconnect. NEC 352.30(A) 4. Label Main disconnect breakers. NEC 408.4 5. Please seal siding at communication conduit penetration. FBC EC TABLE R402.4.1.1 6. Roof Exhaust terminations require a screen (except dryer). FBC R303.6 7. No Hot water in the building (will require directional inspection hot on left at fixtures) 8. Master Lav on left has no water preassure when fixture is turned to the left. 9. Please seal hole in wall inside AHU closet. FBC EC TABLE R402.4.1.1 10. Garage door opener needs to be powered on for saftey device test. UL 325/FBCR 309.4 | |||
| U-CROSS CONNECTION | 04/21/2026 | APPROVED | BWRIGHT |
| ELECTRIC - EARLY POWER | 04/08/2026 | APPROVED | JSTEWART |
| Note: Inspector Notes from Inspection 2200 Authorize release of email 2/27/2026 - PREVIOUS INSPECTION NOTES Not ready for inspection. No panel, outlet, or meter can installed. | |||
| ROW- PRE-APRON (PRE-POUR) | 03/20/2026 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. . TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, IN THE UPCOMING MONTHS THE DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS WILL BE REQUIRED TO BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. YOU WILL RECEIVE A NEWS BLAST WHEN THIS BECOMES NECESSARY. 3/19/2026 - PREVIOUS INSPECTION NOTES 03-18-26 TPOLACEK*** DRIVEWAY IS NOT FORMED CORRECLTY, APRON WINGS ARE TO BE 36" WIDE AND 5' FROM EDGE OF ROAD. POUR AREA SHOULD BE GRADED 6" MINIMUM IN ROW AND 4" MINIMUM BEHIND THE ROW. THERE SHALL BE FREE AND CLEAR OF MATERIALS AND DEBRIS. | |||
| ROW- PRE-APRON (PRE-POUR) | 03/19/2026 | Disapproved -FEE REQUIRED | TPOLACEK |
| Note: 03-18-26 TPOLACEK*** DRIVEWAY IS NOT FORMED CORRECLTY, APRON WINGS ARE TO BE 36" WIDE AND 5' FROM EDGE OF ROAD. POUR AREA SHOULD BE GRADED 6" MINIMUM IN ROW AND 4" MINIMUM BEHIND THE ROW. THERE SHALL BE FREE AND CLEAR OF MATERIALS AND DEBRIS. | |||
| DRYWALL NAILING | 03/13/2026 | APPROVED | KSANDOE |
| LATH/BRICK/ WATER BARRIER | 03/13/2026 | APPROVED | KSANDOE |
| INSULATION | 03/11/2026 | APPROVED | JSTEWART |
| Note: Inspector Notes from Inspection 2420 1. Mechanical fastener at spare bath exhaust duct to fan assembly. 2. 3 screws required at lap joints of hood exhaust duct. 3. Secure pex plumbing to stud for Hose bibb, right back side corner. | |||
| ALL ROUGH | 03/06/2026 | APPROVED - AS NOTED | JSTEWART |
| Note: 1. Mechanical fastener at spare bath exhaust duct to fan assembly. 2. 3 screws required at lap joints of hood exhaust duct. 3. Secure pex plumbing to stud for Hose bibb, right back side corner. | |||
| ELECTRIC-TUG | 03/06/2026 | APPROVED - AS NOTED | JSTEWART |
| Note: Authorize release of email 2/27/2026 - PREVIOUS INSPECTION NOTES Not ready for inspection. No panel, outlet, or meter can installed. | |||
| WALL SHEATHING | 03/02/2026 | APPROVED | JSTEWART |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 03/02/2026 | APPROVED | JSTEWART |
| ROOF VALLEY & METAL | 03/02/2026 | APPROVED | JSTEWART |
| ELECTRIC - EARLY POWER | 02/27/2026 | Disapproved - NO FEE | KSANDOE |
| Note: Wrong inspection scheduled | |||
| ELECTRIC-TUG | 02/27/2026 | Disapproved -FEE REQUIRED | KSANDOE |
| Note: Not ready for inspection. No panel, outlet, or meter can installed. | |||
| GRAVITY SEWER TEST | 02/20/2026 | APPROVED | JSTEWART |
| Note: onsite inspection. | |||
| SEWER TIE IN | 02/20/2026 | APPROVED | JSTEWART |
| Note: onsite inspection. | |||
| MONOLITHIC SLAB | 02/17/2026 | APPROVED | JSTEWART |
| PLUMBING 1ST ROUGH UNDERGROUND | 02/12/2026 | FINAL APPROVED | JSTEWART |
| WATER METER INSTALLATION REQUEST | 02/12/2026 | APPROVED | ISANDERSON |
| FORMBOARD SURVEY (OFFICE USE ONLY) | 02/11/2026 | APPROVED | RRICKS |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 02/11/2026 | 02/11/2026 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 02/11/2026 | 02/11/2026 |
| Note: Released By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 01/20/2026 | 01/26/2026 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 01/20/2026 | 01/23/2026 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 01/20/2026 | 01/26/2026 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 01/20/2026 | 01/21/2026 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| GAS | COMPLETE | 01/20/2026 | 01/22/2026 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 01/20/2026 | 01/22/2026 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 01/20/2026 | 01/22/2026 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 01/20/2026 | 01/27/2026 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 01/20/2026 | 01/21/2026 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| URB | COMPLETE | 01/20/2026 | 01/26/2026 |
| Note: Released By: MATTHEW SIERRA - (386)286-2002 - MSIERRA@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 05/06/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 05/06/2026 |
| RSI REINSPECTION 1 | ¤35.00 | 05/06/2026 |
| RSI ROW FINAL INSPECTION | ¤16.25 | 01/30/2026 |
| SCHOOL BOARD IMPACT FEE RES | ¤5,450.00 | 01/30/2026 |
| SURCHARGE FS 533.721 | ¤8.77 | 01/30/2026 |
| SURCHARGE - FS 468.631 | ¤13.16 | 01/30/2026 |
| SW ENG RES REVIEW 240 | ¤240.00 | 01/30/2026 |
| TRANSP RES IMPACT FEE 10-25 | ¤4,603.17 | 01/30/2026 |
| WASTEWATER PERM INSPECTION | ¤80.00 | 01/30/2026 |
| WASTEWATER PERM REVIEW | ¤25.00 | 01/30/2026 |
| SEWER CAPITAL FACILITY | ¤3,628.86 | 01/30/2026 |
| WATER CAPITAL FACILITY FEE | ¤3,091.14 | 01/30/2026 |
| WATER PERMIT REVIEW | ¤25.00 | 01/30/2026 |
| SITE PLAN 30 | ¤30.00 | 01/30/2026 |
| FC IMPACT FEE EMS | ¤62.00 | 01/30/2026 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 01/30/2026 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 01/30/2026 |
| FIRE RES IMPACT FEE 10-25 | ¤942.00 | 01/30/2026 |
| WATER METER W/OUT TAP | ¤965.03 | 01/30/2026 |
| PARKS IMPACT FEE 10-25 | ¤3,164.00 | 01/30/2026 |
| RECLAIM WATER PERMIT INSPECTIO | ¤40.00 | 01/30/2026 |
| RSI DRIVEWAY AFTER POUR | ¤16.25 | 01/30/2026 |
| RSE DRIVE PRE POUR INSPECTION | ¤32.50 | 01/30/2026 |
| RSI FIELD SURVEY INSPECTION | ¤48.75 | 01/30/2026 |
| RSI FORMBOARD REVIEW | ¤16.25 | 01/30/2026 |
| RSI PLAN REVIEW NEW | ¤48.75 | 01/30/2026 |
| RSI FNL SURVEY/GRADING CERT | ¤48.75 | 01/30/2026 |
| WATER-METER | ¤874.47 | 01/30/2026 |
| WATER- TURN ON | ¤50.00 | 01/30/2026 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 01/30/2026 |
| INSPECTION - RESIDENTIAL | ¤660.00 | 01/30/2026 |
| PLAN REVIEW - RESIDENTIAL | ¤187.20 | 01/30/2026 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤24,998.30 |