I want to search for...

Permit #2026010567

Permit Details

Status: INSPECT

Parcel Id: 07-11-31-7026-00160-0030
CONDITIONED SPACE: 1654 sqft
OPENED PORCH (WITH ROOF) : 119 sqft
GARAGE: 396 sqft
Total Square Footage: 2169 sqft
Block: 00160
Subdivision: 2153 - SECTION 26-PINE GROVE
Job Phone: 407-476-8195
Location Address: 5 PINETREE DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 02/05/2026
NOC: RECORDED
Applicant name: CARLETTE RENE WITTE
Owner: INB BFS LAND LLC

Address

7380 WEST SAND LAKE ROAD

ORLANDO, FL 32819

Address

SUITE 600

ORLANDO, FL 32819

Lot: 0030
Contracted Stated Job Value: ¤250,000.00
Job Description: Construction of New SFR
Type: CN

Contractor

INNOVATIVE NATIONWIDE BUILDERS INC
Status Location Address State License Number Phone
ACTIVE

3670 MAGUIRE BLVD #220

,

CRC1330026 (Exp: 08/31/2026) 855-694-6634

Sub Contractors

JASON LEE JAMES
Status Location Address State License Number Phone
ACTIVE

217 N WESTMONTE DR SUITE 1007

ALTAMONTE SPRINGS, FL 32714

CAC1820196 (Exp: 08/31/2026) 407-404-4000
ANTHONY OKEITH FENNELL
Status Location Address State License Number Phone
ACTIVE

217 N. WESTMONTE DR, SUITE 1007

ALTAMONTE SPRINGS, FL 32714

EC13011194 (Exp: 08/31/2026) 407-404-4000
HEATH EDWARD SANFORD
Status Location Address State License Number Phone
ACTIVE

126 EAST END RD

SAN MATEO, FL 32187

CFC1429896 (Exp: 08/31/2026) 386-871-8823
TERRY BRICE DICKERSON
Status Location Address State License Number Phone
ACTIVE

4300 ST JOHN'S PARKWAY

ALPHARETTA, GA 30009

CCC1326209 (Exp: 08/31/2026) 407-548-6733

Inspection History

Type Request Date Result Inspector
PEP TANK INSTALLATION REQUEST 06/04/2026 APPROVED ISANDERSON
DRYWALL NAILING 05/27/2026 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 5/27/2026 10:46:21 AM *** Approved
INSULATION 05/21/2026 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 5/21/2026 9:01:59 AM *** Approved 5/20/2026 - PREVIOUS INSPECTION NOTES 5/20/26: *** Fireblocking still missing on side of Pantry Closet. Previously marked FB. Also, Fireblocking at bedroom entry does not meet code requirements for fire and smoke resistance. Change to a horizontal 2" x 4" (and fire foam) or firefoam any open spacing. Please firefoam any spacing at added fireblocking. 5/19/2026 - PREVIOUS INSPECTION NOTES 5/19/26: 1). Fireblocking missing at kitchen pantry wall and entryway to right side bedrooms. FB written on studs. FBC-R302.11
INSULATION 05/20/2026 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 5/20/2026 10:46:13 AM *** 5/20/26: *** Fireblocking still missing on side of Pantry Closet. Previously marked FB. Also, Fireblocking at bedroom entry does not meet code requirements for fire and smoke resistance. Change to a horizontal 2" x 4" (and fire foam) or firefoam any open spacing. Please firefoam any spacing at added fireblocking. 5/19/2026 - PREVIOUS INSPECTION NOTES 5/19/26: 1). Fireblocking missing at kitchen pantry wall and entryway to right side bedrooms. FB written on studs. FBC-R302.11
INSULATION 05/19/2026 Disapproved - NO FEE RSIMS
Note: *** NOTES ADDED BY RSIMS 5/19/2026 11:15:31 AM *** 5/19/26: 1). Fireblocking missing at kitchen pantry wall and entryway to right side bedrooms. FB written on studs. FBC-R302.11
ALL ROUGH 05/14/2026 APPROVED KSANDOE
Note: 5/12/2026 - PREVIOUS INSPECTION NOTES 5/12/26: Previously listed item 4 remains unresolved. 4). Front entry door has shim space that exceeds the 1/4" maximum and will require solid blocking. FBCR 609.1 5/8/2026 - PREVIOUS INSPECTION NOTES 5/8/26: 1). Fireblocking above Main Breaker panel does not meet minimum thickness as required. FBC-R302.11.1 (wires will need to be drilled through the new fireblocking once correction is completed). 2). Wires for Range and ODU are not phased out as required. NEC 200.6(B) 3). Primary bathroom: exhaust fan duct needs to be resealed at the roof deck. FBCR M1601.4.1 4). Front entry door has shim space that exceeds the 1/4" maximum and will require solid blocking. FBCR 609.1 3/24/26: Main underground water service piping is installed from house to meter valve (meter installed). Inspected and approved. RS
ALL ROUGH 05/12/2026 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 5/12/2026 10:35:23 AM *** 5/12/26: Previously listed item 4 remains unresolved. 4). Front entry door has shim space that exceeds the 1/4" maximum and will require solid blocking. FBCR 609.1 5/8/2026 - PREVIOUS INSPECTION NOTES 5/8/26: 1). Fireblocking above Main Breaker panel does not meet minimum thickness as required. FBC-R302.11.1 (wires will need to be drilled through the new fireblocking once correction is completed). 2). Wires for Range and ODU are not phased out as required. NEC 200.6(B) 3). Primary bathroom: exhaust fan duct needs to be resealed at the roof deck. FBCR M1601.4.1 4). Front entry door has shim space that exceeds the 1/4" maximum and will require solid blocking. FBCR 609.1 3/24/26: Main underground water service piping is installed from house to meter valve (meter installed). Inspected and approved. RS
ALL ROUGH 05/08/2026 Disapproved - NO FEE RSIMS
Note: *** NOTES ADDED BY RSIMS 5/8/2026 11:19:49 AM *** 5/8/26: 1). Fireblocking above Main Breaker panel does not meet minimum thickness as required. FBC-R302.11.1 (wires will need to be drilled through the new fireblocking once correction is completed). 2). Wires for Range and ODU are not phased out as required. NEC 200.6(B) 3). Primary bathroom: exhaust fan duct needs to be resealed at the roof deck. FBCR M1601.4.1 4). Front entry door has shim space that exceeds the 1/4" maximum and will require solid blocking. FBCR 609.1 3/24/26: Main underground water service piping is installed from house to meter valve (meter installed). Inspected and approved. RS
ELECTRIC-TUG 05/07/2026 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 5/7/2026 10:04:55 AM *** 5/7/26: FPL emailed - Approved for TUG. 5/6/2026 - PREVIOUS INSPECTION NOTES Tug outlet is not trimmed out, needs to have outlet and cover to be safed off.
ELECTRIC-TUG 05/06/2026 Disapproved - NO FEE RMARTIN
Note: Tug outlet is not trimmed out, needs to have outlet and cover to be safed off.
LATH/BRICK/ WATER BARRIER 05/04/2026 APPROVED JSTEWART
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/01/2026 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 5/1/2026 2:27:36 PM *** Approved Inspector Notes from Inspection 2467 *** NOTES ADDED BY RSIMS 4/28/2026 12:59:54 PM *** 4/28/26: Virtually approved via FaceTime video/audio phone app at @ 1140. Inspection 2465 Roof Sheathing was approved as noted on 4/16/26 for Inspection 2460 that still needs to be completed. Inspector Notes from Inspection 2450 *** NOTES ADDED BY RSIMS 4/17/2026 12:38:17 PM *** 4/17/26: Previous note from Roof Sheathing Inspections remains unresolved. Deficiency added to Inspection 2460. Inspector Notes from Inspection 2465 *** NOTES ADDED BY RSIMS 4/16/2026 9:39:30 AM *** 4/16/26: NOTE: Please have excess dirt / unknown substance removed from Trusses T11 and T12 so that original integrity can be verified prior to scheduling inspection 2460 - RS/B/T/DC. Inspector Notes from Inspection 2340 Please have a complete set of plans for inspector in future. Also, have container on site and clean up debris by next inspecton.
GRAVITY SEWER TEST 04/30/2026 APPROVED - AS NOTED HCAMACHO
Note: No PEP tank installed and not connected.
ROOF VALLEY & METAL 04/28/2026 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 4/28/2026 12:59:54 PM *** 4/28/26: Virtually approved via FaceTime video/audio phone app at @ 1140. Inspection 2465 Roof Sheathing was approved as noted on 4/16/26 for Inspection 2460 that still needs to be completed. Inspector Notes from Inspection 2450 *** NOTES ADDED BY RSIMS 4/17/2026 12:38:17 PM *** 4/17/26: Previous note from Roof Sheathing Inspections remains unresolved. Deficiency added to Inspection 2460. Inspector Notes from Inspection 2465 *** NOTES ADDED BY RSIMS 4/16/2026 9:39:30 AM *** 4/16/26: NOTE: Please have excess dirt / unknown substance removed from Trusses T11 and T12 so that original integrity can be verified prior to scheduling inspection 2460 - RS/B/T/DC. Inspector Notes from Inspection 2340 Please have a complete set of plans for inspector in future. Also, have container on site and clean up debris by next inspecton.
WALL SHEATHING 04/17/2026 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 4/17/2026 12:38:17 PM *** 4/17/26: Previous note from Roof Sheathing Inspections remains unresolved. Deficiency added to Inspection 2460. Inspector Notes from Inspection 2465 *** NOTES ADDED BY RSIMS 4/16/2026 9:39:30 AM *** 4/16/26: NOTE: Please have excess dirt / unknown substance removed from Trusses T11 and T12 so that original integrity can be verified prior to scheduling inspection 2460 - RS/B/T/DC. Inspector Notes from Inspection 2340 Please have a complete set of plans for inspector in future. Also, have container on site and clean up debris by next inspecton.
ROOF SHEATHING 04/16/2026 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 4/16/2026 9:39:30 AM *** 4/16/26: NOTE: Please have excess dirt / unknown substance removed from Trusses T11 and T12 so that original integrity can be verified prior to scheduling inspection 2460 - RS/B/T/DC. Inspector Notes from Inspection 2340 Please have a complete set of plans for inspector in future. Also, have container on site and clean up debris by next inspecton.
TIE BEAM / LINTEL 04/06/2026 APPROVED - AS NOTED PKNAPIK
Note: Please have a complete set of plans for inspector in future. Also, have container on site and clean up debris by next inspecton.
MONOLITHIC SLAB 03/30/2026 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 3/30/2026 9:48:00 AM *** Approved 3/26/2026 - PREVIOUS INSPECTION NOTES 3/26/26: 1): Garage front footer > remove roots from footer area. FBC R318.6.2 2). Please remove any dirt cave in caused by rain throughout footers. FBC-R404.1.3.3.7.4
MONOLITHIC SLAB 03/26/2026 Disapproved - NO FEE RSIMS
Note: *** NOTES ADDED BY RSIMS 3/26/2026 2:51:53 PM *** 3/26/26: 1): Garage front footer > remove roots from footer area. FBC R318.6.2 2). Please remove any dirt cave in caused by rain throughout footers. FBC-R404.1.3.3.7.4
PLUMBING 1ST ROUGH UNDERGROUND 03/24/2026 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 3/24/2026 1:23:52 PM *** 3/24/26: Main underground water service piping is installed from house to meter valve (meter installed). Inspected and approved. RS
FORMBOARD SURVEY (OFFICE USE ONLY) 03/23/2026 APPROVED RRICKS
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 03/19/2026 APPROVED PKNAPIK
WATER METER INSTALLATION REQUEST 03/04/2026 APPROVED ISANDERSON
BLD - BUILDING FINAL
U-CROSS CONNECTION
ROW- PRE-APRON (PRE-POUR)
ROW - FINAL APRON (AFTER POUR)
ROW - FINAL INSPECTION
U -UTILITY RESIDENTIAL FINAL
SEWER TIE IN
ELECTRIC - EARLY POWER

Review History

Department Status Date In Date Out
BLD COMPLETE 04/17/2026 04/21/2026
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
SW1 COMPLETE 03/20/2026 03/23/2026
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 03/20/2026 03/20/2026
Note: Released By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM
BLD COMPLETE 03/19/2026 03/19/2026
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
ZON COMPLETE 01/28/2026 01/28/2026
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
SW1 COMPLETE 01/28/2026 02/02/2026
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
SWALE COMPLETE 01/21/2026 01/28/2026
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
BLD COMPLETE 01/20/2026 01/23/2026
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
CUSVC COMPLETE 01/20/2026 01/23/2026
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 01/20/2026 01/26/2026
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 01/20/2026 01/21/2026
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
GAS CANCEL 01/20/2026 01/22/2026
LOCATE COMPLETE 01/20/2026 01/22/2026
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH COMPLETE 01/20/2026 01/22/2026
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 01/20/2026 01/27/2026
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON HOLD 01/20/2026 01/21/2026
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Site plna : please correct the map panel number

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
FC IMPACT FEE EMS ¤62.00 02/05/2026
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 02/05/2026
FC IMPACT FEE LIBRARY ¤268.00 02/05/2026
FIRE RES IMPACT FEE 10-25 ¤942.00 02/05/2026
PEP TANK INSTALL ¤756.74 02/05/2026
PARKS IMPACT FEE 10-25 ¤3,164.00 02/05/2026
RSI DRIVEWAY AFTER POUR ¤16.25 02/05/2026
RSE DRIVE PRE POUR INSPECTION ¤32.50 02/05/2026
RSI FIELD SURVEY INSPECTION ¤48.75 02/05/2026
RSI FORMBOARD REVIEW ¤16.25 02/05/2026
RSI PLAN REVIEW NEW ¤48.75 02/05/2026
RSI FNL SURVEY/GRADING CERT ¤48.75 02/05/2026
RSI ROW FINAL INSPECTION ¤16.25 02/05/2026
SCHOOL BOARD IMPACT FEE RES ¤5,450.00 02/05/2026
WASTEWATER MAIN EXTENSION IMPA ¤2,385.00 02/05/2026
SURCHARGE FS 533.721 ¤11.56 02/05/2026
SURCHARGE - FS 468.631 ¤17.34 02/05/2026
SW ENG RES REVIEW 240 ¤240.00 02/05/2026
WATER METER W/ TAP ¤2,326.93 02/05/2026
TRANSP RES IMPACT FEE 10-25 ¤6,235.58 02/05/2026
SEWER CREDIT (¤1,147.00) 02/05/2026
WASTEWATER PERM INSPECTION ¤80.00 02/05/2026
WASTEWATER PERM REVIEW ¤25.00 02/05/2026
SEWER CAPITAL FACILITY ¤4,415.00 02/05/2026
WATER CAPITAL FACILITY FEE ¤3,790.49 02/05/2026
WATER PERMIT REVIEW ¤25.00 02/05/2026
WATER MAIN EXTENSION IMPACT ¤917.27 02/05/2026
SITE PLAN 30 ¤30.00 02/05/2026
WATER- TURN ON ¤50.00 02/05/2026
ADMINISTRATIVE RESIDENTIAL ¤30.00 02/05/2026
INSPECTION - RESIDENTIAL ¤877.25 02/05/2026
PLAN REVIEW - RESIDENTIAL ¤248.82 02/05/2026
REINSPECTION RESIDENTIAL ¤40.00
REINSPECTION RESIDENTIAL ¤40.00
Fees Total Due: ¤80.00 Total Paid: ¤31,646.48