I want to search for...
Permit #2026010702
Permit Details
Status: INSPECT
| Parcel Id: 05-12-31-2755-00000-0110 |
| CONDITIONED SPACE: 2118 sqft |
| GARAGE: 478 sqft |
| OPENED PORCH (WITH ROOF) : 300 sqft |
| Total Square Footage: 2896 sqft |
| Subdivision: 2313 - THE GABLES SUBDIVISION AT TOWN CENTER |
| Job Phone: (386)756-0439 |
| Location Address: 221 HAWTHORN AVE |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 02/05/2026 |
| NOC: RECORDED |
| Applicant name: JAMES MICHAEL MATHER |
| Owner: PAYTAS HOMES INC |
|
Address PO BOX 290490 PORT ORANGE, FL 32127 |
| Lot: 11 |
| Contracted Stated Job Value: ¤385,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
PAYTAS HOMES INC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
PO BOX 290490 PORT ORANGE, FL 32127 |
CBC1261873 (Exp: 08/31/2026) | (386)756-0439 |
Sub Contractors
GERALD EDWARD MASTERS JR
| Status | Location Address | State License Number | Phone |
| ACTIVE |
505 HERBERT STREET PORT ORANGE, FL 32129 |
EC13003217 (Exp: 08/31/2026) | (386)304-2600 |
JONATHAN M PEARSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
209 N FORSYTH ST BUNNELL, FL 32110 |
CFC1425941 (Exp: 08/31/2026) | 386-597-0944 | 386-437-4996 |
BRANDON LEONARD LOSIK
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4680 LAKE INDUSTRIAL BLVD TAVARES, FL 32778 |
CCC1335106 (Exp: 08/31/2026) | 407-604-2099 |
BRENT JAMES STURGELL
| Status | Location Address | State License Number | Phone |
| ACTIVE |
651 CARSWELL AVE HOLLY HILL , FL 32117 |
CAC1822599 (Exp: 08/31/2026) | 386-252-1878 |
Inspection History
| Type | Request Date | Result | Inspector |
| ELECTRIC - EARLY POWER | 06/10/2026 | Approval - Private Provider | PPROVIDER |
| ROW- PRE-APRON (PRE-POUR) | 06/09/2026 | APPROVED | FSLADISH |
| Note: 6/9/26 YOU ARE APPROVED TO LAY PAVER AS OF THIS INSPECTION. CITY OF PALM COAST MINIMUM STANDARDS ARE MET AT THE TIME OF THIS INSPECTION. IT IS THE BUILDER'S AND/OR HOMEOWNER’S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. ________________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9270 6/3/26 DUE TO THE GRADFATHERED LONGER APRONS IN THIS SUBDIVISION THE SIDEWALK ON THE RIGHT SIDE DEVIATES IN A SHORT SECTION TO EXIT BACK TO ORIGINAL DISTANCE. THIS HAS BEEN ALLOWED SINCE THE GRANDFATHERING. APPROVING AS NOTED. AT THE TIME OF THE INSPECTION PREPOUR AREA IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD REMOVE ALL WATER AND CHECK COMPACTION BEFORE POURING CONCRETE. 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED IS REQUIRED. PLEASE REVIEW CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. NO EXPANSION JOINTS ALLOWED. | |||
| ROW- PAVER RESTRAINTS | 06/08/2026 | APPROVED | FSLADISH |
| Note: 6/8/26 FORGOT TO ADD AND RESULT THIS INSPECTION WHEN ORIGINAL WAS COMPLETED. AT THE TIME OF THIS INSPECTION YOU ARE APPROVED TO POUR YOUR DRIVEWAY PAVER RESTRAINTS. **** DO NOT LAY ANY PAVERS UNTIL AFTER A SECONDARY SPREAD AND COMPACTION INSPECTION HAS BEEN SCHEDULED AND PASSED**** BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS Inspector Notes from Inspection 9270 6/3/26 DUE TO THE GRADFATHERED LONGER APRONS IN THIS SUBDIVISION THE SIDEWALK ON THE RIGHT SIDE DEVIATES IN A SHORT SECTION TO EXIT BACK TO ORIGINAL DISTANCE. THIS HAS BEEN ALLOWED SINCE THE GRANDFATHERING. APPROVING AS NOTED. AT THE TIME OF THE INSPECTION PREPOUR AREA IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD REMOVE ALL WATER AND CHECK COMPACTION BEFORE POURING CONCRETE. 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED IS REQUIRED. PLEASE REVIEW CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. NO EXPANSION JOINTS ALLOWED. | |||
| ROW- PRE-APRON (PRE-POUR) | 06/03/2026 | APPROVED - AS NOTED | FSLADISH |
| Note: 6/3/26 DUE TO THE GRADFATHERED LONGER APRONS IN THIS SUBDIVISION THE SIDEWALK ON THE RIGHT SIDE DEVIATES IN A SHORT SECTION TO EXIT BACK TO ORIGINAL DISTANCE. THIS HAS BEEN ALLOWED SINCE THE GRANDFATHERING. APPROVING AS NOTED. AT THE TIME OF THE INSPECTION PREPOUR AREA IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD REMOVE ALL WATER AND CHECK COMPACTION BEFORE POURING CONCRETE. 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED IS REQUIRED. PLEASE REVIEW CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. NO EXPANSION JOINTS ALLOWED. | |||
| DRYWALL NAILING | 04/16/2026 | Approval - Private Provider | PPROVIDER |
| LATH/BRICK/ WATER BARRIER | 04/13/2026 | Approval - Private Provider | PPROVIDER |
| INSULATION | 04/10/2026 | Approval - Private Provider | PPROVIDER |
| ALL ROUGH | 04/07/2026 | Approval - Private Provider | PPROVIDER |
| ROOF VALLEY & METAL | 03/12/2026 | Approval - Private Provider | PPROVIDER |
| WALL SHEATHING | 03/04/2026 | Approval - Private Provider | PPROVIDER |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 03/04/2026 | Approval - Private Provider | PPROVIDER |
| ELECTRIC-TUG | 02/26/2026 | Approval - Private Provider | PPROVIDER |
| MONOLITHIC SLAB | 02/20/2026 | Approval - Private Provider | PPROVIDER |
| TIE BEAM / LINTEL | 02/20/2026 | Approval - Private Provider | PPROVIDER |
| PLUMBING 1ST ROUGH UNDERGROUND | 02/12/2026 | Approval - Private Provider | PPROVIDER |
| FORMBOARD SURVEY (OFFICE USE ONLY) | 02/10/2026 | APPROVED | RRICKS |
| GRAVITY SEWER TEST | 02/09/2026 | Approval - Private Provider | PPROVIDER |
| SEWER TIE IN | 02/09/2026 | APPROVED | BTAYLOR |
| WATER METER INSTALLATION REQUEST | 02/06/2026 | APPROVED | CBOWERMASTER |
| U-CROSS CONNECTION | |||
| BLD - BUILDING FINAL | |||
| ROW - FINAL APRON (AFTER POUR) | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | |||
| Note: Approved as noted - 2/3/2026 - RRIcks After conversations with the Engineer, Noah, existing elevations along the lot lines are lower than edge of pavement resulting in puddling on the left side. Please ensure that during construction NO LOT is negatively impacted. If negative impacts are identified by inspector changes must be addressed before final approval. This was made clear to Rodney Smith the CM as well. | |||
| ROW - FINAL INSPECTION | |||
| U -UTILITY RESIDENTIAL FINAL |
Review History
| Department | Status | Date In | Date Out |
| BADMIN | COMPLETE | 02/12/2026 | 02/12/2026 |
| Note: Released By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 02/09/2026 | 02/10/2026 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 02/09/2026 | 02/09/2026 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| BADMIN | HOLD | 02/09/2026 | 02/09/2026 |
| Note: Held By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM SCHEDULE INSPECTION FOR 2060 | |||
| ZON | COMPLETE | 02/04/2026 | 02/04/2026 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 02/03/2026 | 02/03/2026 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Approved as noted: After conversations with the Engineer, Noah, existing elevations along the lot lines are lower than edge of pavement resulting in puddling. Please ensure that during construction NO LOT is negatively impacted. If negative impacts are identified by inspector changes must be addressed before final approval. This was made clear to Rodney Smith the CM as well. | |||
| SW1 | HOLD | 01/28/2026 | 01/28/2026 |
| Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Disregard previous HOLD comments New Comments: - Along the lot lines between improved lot 10 and this lot, proposed elevations are changing existing elevations more than 0.1' negatively impacting lot existing drainage pattern. Proposed elevations along common lot lines are not allowed to be more than ± 0.1' of existing conditions adjacent to improved lots. COPC Note: Community sidewalk approved based on existing conditions out in the field. Any issues found by inspector must be corrected. Please feel free to call or email if there are questions or concerns. | |||
| ZON | HOLD | 01/27/2026 | 01/27/2026 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM repeat comment Color sheet: Elevation plan. the house shows as if the home will have two colors. please refer to the color sheet as only accents can have a separate color and accents are listed. this plan does not meet code as it exceeds 20 percent of any one elevation. | |||
| CUSVC | COMPLETE | 01/22/2026 | 02/03/2026 |
| Note: Released By: CYNTHIA SCHWEERS - - CSCHWEERS@PALMCOASSTGOV.COM | |||
| ENGIN1 | COMPLETE | 01/22/2026 | 01/23/2026 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 01/22/2026 | 01/30/2026 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 01/22/2026 | 01/28/2026 |
| Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM - Please provide a paver detail for the driveway. - Along the lot lines between improved lot 10 and this lot, proposed elevations are changing existing elevations more than 0.1' negatively impacting lot existing drainage pattern. Proposed elevations along common lot lines are not allowed to be more than ± 0.1' of existing conditions adjacent to improved lots. COPC Note: Community sidewalk approved based on existing conditions out in the field. Any issues found by inspector must be corrected. Please feel free to call or email if there are questions or concerns. | |||
| ZON | HOLD | 01/22/2026 | 01/26/2026 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Color sheet: Elevation plan. the house shows as if the home will have two colors. please refer to the color sheet as only accents can have a separate color and accents are listed. this plan does not meet code as it exceeds 20 percent of any one elevation. | |||
| URB | COMPLETE | 01/22/2026 | 01/29/2026 |
| Note: Released By: JOHN BEAUDET - (386)986-2456 - JBEAUDET@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| FC IMPACT FEE EMS | ¤62.00 | 02/05/2026 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 02/05/2026 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 02/05/2026 |
| FIRE RES IMPACT FEE 10-25 | ¤942.00 | 02/05/2026 |
| WATER METER W/OUT TAP | ¤965.03 | 02/05/2026 |
| PARKS IMPACT FEE 10-25 | ¤3,164.00 | 02/05/2026 |
| RECLAIM WATER PERMIT INSPECTIO | ¤40.00 | 02/05/2026 |
| RSI DRIVEWAY AFTER POUR | ¤16.25 | 02/05/2026 |
| RSE DRIVE PRE POUR INSPECTION | ¤32.50 | 02/05/2026 |
| RSI FIELD SURVEY INSPECTION | ¤48.75 | 02/05/2026 |
| RSI FORMBOARD REVIEW | ¤16.25 | 02/05/2026 |
| RSI PLAN REVIEW NEW | ¤48.75 | 02/05/2026 |
| RSI FNL SURVEY/GRADING CERT | ¤48.75 | 02/05/2026 |
| RSI ROW FINAL INSPECTION | ¤16.25 | 02/05/2026 |
| SCHOOL BOARD IMPACT FEE RES | ¤5,450.00 | 02/05/2026 |
| SURCHARGE FS 533.721 | ¤2.55 | 02/05/2026 |
| SURCHARGE - FS 468.631 | ¤3.83 | 02/05/2026 |
| TRANSP RES IMPACT FEE 10-25 | ¤7,984.86 | 02/05/2026 |
| WASTEWATER PERM INSPECTION | ¤80.00 | 02/05/2026 |
| WASTEWATER PERM REVIEW | ¤25.00 | 02/05/2026 |
| WATER PERMIT REVIEW | ¤25.00 | 02/05/2026 |
| SITE PLAN 30 | ¤30.00 | 02/05/2026 |
| WATER-METER | ¤874.47 | 02/05/2026 |
| WATER- TURN ON | ¤50.00 | 02/05/2026 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 02/05/2026 |
| ADMINISTRATIVE - RESID PP | ¤225.00 | 02/05/2026 |
| CONTRACTOR CHANGE | ¤20.00 | |
| Fees | Total Due: ¤20.00 | Total Paid: ¤20,667.24 |