I want to search for...

Permit #2026010722

Permit Details

Status: INSPECT

Parcel Id: 07-11-31-7016-00040-0040
CONDITIONED SPACE: 1765 sqft
GARAGE: 751 sqft
OPENED PORCH (WITH ROOF) : 319 sqft
Total Square Footage: 2835 sqft
Block: 00040
Subdivision: 2201 - SECTION 16-COUNTRY CLUB COVE
Job Phone: 386-283-2035
Location Address: 33 COLECHESTER LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 02/27/2026
NOC: RECORDED
Applicant name: OLEG BELINSKIY
Owner: PAUL DONALD R JR & LINDA G H&W

Address

7 6TH ST

ST AUGUSTINE, FL 32080

Lot: 0040
Contracted Stated Job Value: ¤335,000.00
Job Description: SINGLE FAMILY RESIDENTIAL HOUSE
Type: CN

Contractor

FLORIDAS BEST BUILDERS INC
Status Location Address State License Number Phone
ACTIVE

19 PINE CIRCLE DRIVE

PALM COAST, FL 32164

CBC1264760 (Exp: 08/31/2026) 386-283-2035

Sub Contractors

OLEG BELINSKIY
Status Location Address State License Number Phone
ACTIVE

19 PINE CIRCLE DRIVE19

PALM COAST, FL 32167

CCC1325974 (Exp: 08/31/2026) 386-263-7906
JUAN CARLOS GONZALEZ
Status Location Address State License Number
ACTIVE

1328 COUNTY ROAD 308

CRESCENT CITY, FL 32112

RF11067806 (Exp: 08/31/2027)
TIMUR ISPARYAN
Status Location Address State License Number Phone Fax
ACTIVE

3665 SPRINK PARK ROAD

JACKSONVILLE , FL 32207

CMC1249968 (Exp: 08/31/2026) 904-245-1818 904-337-1910
FERNANDO MEZA SR
Status Location Address State License Number Phone
ACTIVE

457 CHELSEA PLACE AVE

ORMOND BEACH, FL 32174

EC13003906 (Exp: 08/31/2026) 386-241-5211

Inspection History

Type Request Date Result Inspector
ROOF VALLEY & METAL 06/08/2026 APPROVED MCONTRYMAN
Note: Inspector Notes from Inspection 2460 1.B01 missing a peice of eng. marked. 2.Remove all shiners from roof decking.FBC R803.2.3 *Will check at next inspection.*
WALL SHEATHING 06/02/2026 APPROVED HCAMACHO
ROOF SHEATHING / BRACES/TIES/DOWN CELL 06/02/2026 APPROVED - AS NOTED HCAMACHO
Note: 1.B01 missing a peice of eng. marked. 2.Remove all shiners from roof decking.FBC R803.2.3 *Will check at next inspection.*
TIE BEAM / LINTEL 05/08/2026 APPROVED MCONTRYMAN
Note: 5/5/2026 - PREVIOUS INSPECTION NOTES 5/5/26 1. Block grout joint exceeded in rear left corner (by door way) FBCR 606.3.1 2. Block grout joint exceeded in left rear window FBCR 606.3.1 --Inspector will meet contractor on site to show areas in need of fixing if you need 4/30/2026 - PREVIOUS INSPECTION NOTES 4/30/26 1. Block grout joint exceeded in rear left corner (by door way) FBCR 606.3.1 2. Block grout joint exceeded in left rear window FBCR 606.3.1 3. Need to move hose bib in front left window and replace the sill, as it was cut to accomodate the line. Also the grout spacing on the block below this window FBCR 606.3.1
TIE BEAM / LINTEL 05/05/2026 Disapproved -FEE REQUIRED MCONTRYMAN
Note: 5/5/26 1. Block grout joint exceeded in rear left corner (by door way) FBCR 606.3.1 2. Block grout joint exceeded in left rear window FBCR 606.3.1 --Inspector will meet contractor on site to show areas in need of fixing if you need 4/30/2026 - PREVIOUS INSPECTION NOTES 4/30/26 1. Block grout joint exceeded in rear left corner (by door way) FBCR 606.3.1 2. Block grout joint exceeded in left rear window FBCR 606.3.1 3. Need to move hose bib in front left window and replace the sill, as it was cut to accomodate the line. Also the grout spacing on the block below this window FBCR 606.3.1
TIE BEAM / LINTEL 04/30/2026 Disapproved - NO FEE MCONTRYMAN
Note: 4/30/26 1. Block grout joint exceeded in rear left corner (by door way) FBCR 606.3.1 2. Block grout joint exceeded in left rear window FBCR 606.3.1 3. Need to move hose bib in front left window and replace the sill, as it was cut to accomodate the line. Also the grout spacing on the block below this window FBCR 606.3.1
TIE BEAM / LINTEL 04/29/2026 CANCELLED BY APPLICANT WEB
MONOLITHIC SLAB 04/06/2026 APPROVED MCONTRYMAN
PLUMBING 1ST ROUGH UNDERGROUND 03/31/2026 APPROVED - AS NOTED MCONTRYMAN
Note: Water meter installed
FORMBOARD SURVEY (OFFICE USE ONLY) 03/30/2026 APPROVED RRICKS
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 03/12/2026 APPROVED PKNAPIK
WATER METER INSTALLATION REQUEST 03/05/2026 APPROVED ISANDERSON
U-CROSS CONNECTION
ROW- PRE-APRON (PRE-POUR)
ROW - FINAL APRON (AFTER POUR)
ROW - FINAL INSPECTION
U -UTILITY RESIDENTIAL FINAL
LATH/BRICK/ WATER BARRIER
GRAVITY SEWER TEST
SEWER TIE IN
ELECTRIC - EARLY POWER
ALL ROUGH
INSULATION
DRYWALL NAILING
BLD - BUILDING FINAL

Review History

Department Status Date In Date Out
BLD COMPLETE 05/28/2026 06/01/2026
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
SW1 COMPLETE 04/15/2026 04/16/2026
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 04/15/2026 04/15/2026
Note: Released By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM
PLFM COMPLETE 04/15/2026 04/16/2026
Note: Released By: JORDAN MYERS, C.F.M - (386)986-4789 - JMYERS@PALMCOASTGOV.COM According to the Foundation Survey submitted on 4/15/26, the structure will not fall inside the SFHA. No elevation certificates are required.
SW1 COMPLETE 03/30/2026 03/30/2026
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 03/30/2026 03/30/2026
Note: Released By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM
BLD COMPLETE 03/16/2026 03/18/2026
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 03/12/2026 03/12/2026
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
ZON COMPLETE 02/23/2026 02/23/2026
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Bring originals to the office for processing.
SWALE COMPLETE 02/17/2026 03/03/2026
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
ENGIN1 COMPLETE 02/13/2026 02/17/2026
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
MECH COMPLETE 02/13/2026 02/17/2026
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ELEC COMPLETE 02/13/2026 02/23/2026
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 02/13/2026 02/23/2026
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
SW1 COMPLETE 02/13/2026 02/18/2026
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON HOLD 02/13/2026 02/13/2026
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM please correct the Printed names as well first, middle , last
CUSVC COMPLETE 02/13/2026 02/19/2026
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ZON HOLD 01/29/2026 01/29/2026
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Row agreement :fill out the form correctly thats not the last name Paul is the last name
SW1 HOLD 01/28/2026 01/28/2026
Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Disregard previous HOLD comments New HOLD Comments: - There is no benchmark on grading plan. - On the left side there are slopes greater than 4:1 between lot lines and interior swale. - Additionally on the right side of the home there are several proposed slopes at the max slope allowed. Please ensure if there are no revisions to the proposed elevation that the 4:1 slopes are not exceeded during constrution, which will result in a hold.
PLFM COMPLETE 01/23/2026 01/27/2026
Note: Released By: JORDAN MYERS, C.F.M - (386)986-4789 - JMYERS@PALMCOASTGOV.COM According to the Drainage and Site Plans submitted on 1/22/26, the structure will not fall inside the SFHA. No elevation certificates are required.
BLD HOLD 01/22/2026 01/27/2026
Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM 1. Provide presumptive load bearing value used for foundation design per R401.4.1 on foundation page. 2. Plans need to be digitally signed, sealed, and verifiable. 3. Truss packet needs to have address. 4. Provide complete truss plan submittal packet to include all of the following: A. Complete truss plan packet, signed and sealed by a Florida licensed professional engineer (the truss design engineer) B. Truss layout / placement plan from truss manufacturer C. Truss profile plan sheets for all trusses. D. Complete truss plan packet cover sheet or first page to include the design professional of record (building design engineer or architect) approval stamp (shop drawing review) indicating acceptance and approval of truss design (Not wet seal)
CUSVC HOLD 01/22/2026 01/30/2026
Note: Held By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM Please upload a new utility application to reflect single family instead of duplex
ELEC HOLD 01/22/2026 01/27/2026
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need correct outlet spacing in office. NEC 2020 210.52 2. Washer and dryer need to be GFCI protected. NEC 2020 210.8 3. DW outlet can not be located behind the DW. NEC 2020 422.16 4. Electric load calcs need to include pool equipment 5. Submit a riser diagram that includes all wire sizes and breaker sizes. Also must include the surge protectors and outside disconnects. NEC 2020 230.67, 230.85
ENGIN1 HOLD 01/22/2026 01/23/2026
Note: Held By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM Benchmark note missing elevation.
GAS CANCEL 01/22/2026 01/23/2026
LOCATE COMPLETE 01/22/2026 01/30/2026
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH HOLD 01/22/2026 01/26/2026
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide return air out of home office on duct layout
SW1 HOLD 01/22/2026 01/28/2026
Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM - There is no benchmark on grading plan. - On the left side there are slopes greater than 4:1 between lot lines and interior swale. - Additionally on the right side of the home there are several proposed slopes at the max slope allowed. Please ensure if there are no revisions to the proposed elevation that the 4:1 slopes are not exceeded during constrution, which will result in a hold. - Please provide paver detail for driveway
ZON HOLD 01/22/2026 01/28/2026
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Site plan Plantings will be needed across the front of the foundtion 8 are needed across the front of the house. Front entry will require shrubs House needs to meet the all setbacks currently that house does not meet the setbacks. Landscape: Residential homes shall provide a foundation planting consisting of 16 shrubs on interior lots. Eight shrubs shall be planted in front of home and four shrubs planted on each side of the home. The corners of the home shall be wrapped with shrubbery or have an understory tree planted there Floor Plan: please rename the office to study. Elevation plan: one more form of articulation needed. Facade articulation is required to add interest to a building. The following features shall be acceptable techniques of exterior articulation. A base course or plinth course: Banding, molding, or stringcourses; quoins; oriels; cornices; arches; balconies; brackets; shutters; keystones; dormers; louvers; as part of the exterior wall construction. ROW agreement: Needed for paver driveway Right of way agreement needed please have all owners on deed sign and notarize. Names to be the same as the deed. Please submit it through the portal for review first, once approved the originals will be requested to be brought into our office for processing

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
FC IMPACT FEE EMS ¤62.00 02/27/2026
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 02/27/2026
FC IMPACT FEE LIBRARY ¤268.00 02/27/2026
FIRE RES IMPACT FEE 10-25 ¤942.00 02/27/2026
RECORDING FEE REIMBURSE DOC ¤52.50 02/27/2026
PARKS IMPACT FEE 10-25 ¤3,164.00 02/27/2026
RSI DRIVEWAY AFTER POUR ¤16.25 02/27/2026
RSE DRIVE PRE POUR INSPECTION ¤32.50 02/27/2026
RSI FIELD SURVEY INSPECTION ¤48.75 02/27/2026
RSI FORMBOARD REVIEW ¤16.25 02/27/2026
RSI PLAN REVIEW NEW ¤48.75 02/27/2026
RSI FNL SURVEY/GRADING CERT ¤48.75 02/27/2026
RSI ROW FINAL INSPECTION ¤16.25 02/27/2026
SCHOOL BOARD IMPACT FEE RES ¤5,450.00 02/27/2026
WASTEWATER MAIN EXTENSION IMPA ¤2,385.00 02/27/2026
SURCHARGE FS 533.721 ¤13.57 02/27/2026
SURCHARGE - FS 468.631 ¤20.36 02/27/2026
SW ENG RES REVIEW 240 ¤240.00 02/27/2026
WATER METER W/ TAP ¤2,326.93 02/27/2026
TRANSP RES IMPACT FEE 10-25 ¤6,654.05 02/27/2026
SEWER CREDIT (¤1,147.00) 02/27/2026
WASTEWATER PERM INSPECTION ¤80.00 02/27/2026
WASTEWATER PERM REVIEW ¤25.00 02/27/2026
SEWER CAPITAL FACILITY ¤4,415.00 02/27/2026
WATER CAPITAL FACILITY FEE ¤3,790.49 02/27/2026
WATER PERMIT REVIEW ¤25.00 02/27/2026
WATER MAIN EXTENSION IMPACT ¤917.27 02/27/2026
SITE PLAN 30 ¤30.00 02/27/2026
WATER- TURN ON ¤50.00 02/27/2026
ADMINISTRATIVE RESIDENTIAL ¤30.00 02/27/2026
INSPECTION - RESIDENTIAL ¤1,034.00 02/27/2026
PLAN REVIEW - RESIDENTIAL ¤293.28 02/27/2026
REINSPECTION RESIDENTIAL ¤40.00
Fees Total Due: ¤40.00 Total Paid: ¤31,566.95