Permit #2026010839

Permit Details

Status: INSPECT

Parcel Id: 07-11-31-7007-00030-0400
CONDITIONED SPACE: 2220 sqft
CONDITIONED SPACE: 921 sqft
OPENED PORCH (WITH ROOF) : 185 sqft
GARAGE: 652 sqft
Total Square Footage: 3978 sqft
Block: 00030
Subdivision: 2185 - SECTION 7-FLORIDA PARK
Job Phone: 386-445-9009
Location Address: 102 FOXHALL LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 02/11/2026
NOC: RECORDED
Applicant name: BRIAN ANDREW GAZZOLI
Owner: SEAGATE HOMES LLC

Address

185 CYPRESS POINT PKWY

PALM COAST, FL 32164

Address

STE 7

PALM COAST, FL 32164

Lot: 0400
Contracted Stated Job Value: ¤330,000.00
Job Description: New construction single family residence
Type: CN

Contractor

SEAGATE HOMES, LLC
Status Location Address Mailing Address State License Number Phone
ACTIVE

185 CYPRESS POINT PARKWAY

Palm Coast, FL 32137

SUITE 7

Palm Coast, FL 32137

CGC1518372 (Exp: 08/31/2026) 386-246-6132

Sub Contractors

RICHARD H SIMMONS JR
Status Location Address State License Number Phone Fax
ACTIVE

PO BOX 1963

BUNNELL, FL 32110

ES12001217 (Exp: 08/31/2026) 386-437-0607 386-437-1847
CHAD DAVID GRESSANI
Status Location Address State License Number Phone Fax
ACTIVE

2640 BROOKSHIRE CIRCLE

MELBOURNE, FL 32904

CCC1327235 (Exp: 08/31/2026) 321-288-6415 321-729-8997
TIMUR ISPARYAN
Status Location Address State License Number Phone Fax
ACTIVE

3665 SPRINK PARK ROAD

JACKSONVILLE , FL 32207

CMC1249968 (Exp: 08/31/2026) 904-245-1818 904-337-1910
ROBERTO F GONZALEZ
Status Location Address State License Number Phone
ACTIVE

212 PALMETTO AVE

CRESCENT CITY, FL 32112

RF11067887 (Exp: 08/31/2027) 286-559-2885

Inspection History

Type Request Date Result Inspector
SEWER TIE IN 06/10/2026 APPROVED HCAMACHO
Note: Virtual Inspection 5/21/2026 - PREVIOUS INSPECTION NOTES 5/21/26 1. Cannot see connection due to it being covered with water/dirt FBC(A) 110.1
ELECTRIC - EARLY POWER 06/09/2026 APPROVED - AS NOTED MCONTRYMAN
Note: 6/9/26 Emailed FLP -Virtual Inspection -Master BR found to have switches behind door. CM said door with correct swing is on order NEC-210.70(A)(1) 6/4/2026 - PREVIOUS INSPECTION NOTES 6/4/26 1. In-law suite has wire behind sink cabinet that needs to be found and safed off NEC 440.14 -Master BR found to have switches behind door. CM said door with correct swing is on order NEC-210.70(A)(1)
FOOTER 06/09/2026 APPROVED MCONTRYMAN
Note: For rear patio
ROW- PRE-APRON (PRE-POUR) 06/09/2026 APPROVED - AS NOTED TPOLACEK
Note: RSI INSPECTORS DO NOT INSPECT PATIO PRE POURS. IF THIS IS A STRUCTURAL INSPECTION FOR FOOTERS THAT WOULD BE COMPLETED BY BUILDING DEPT AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. WOOD CONTROL JOINTS ARE PROHIBITED IN THE RIGHT-OF-WAY. SAWCUT SHALL BE PROVIDED AT THE EDGE OF ROW AND EVERY 12' THEREAFTER, OR A MINIMUM OF 2 SAWCUTS WHICHEVER IS GREATER"
ELECTRIC - EARLY POWER 06/04/2026 Disapproved - NO FEE MCONTRYMAN
Note: 6/4/26 1. In-law suite has wire behind sink cabinet that needs to be found and safed off NEC 440.14 -Master BR found to have switches behind door. CM said door with correct swing is on order NEC-210.70(A)(1)
GRAVITY SEWER TEST 05/21/2026 APPROVED MCONTRYMAN
SEWER TIE IN 05/21/2026 Disapproved - NO FEE MCONTRYMAN
Note: 5/21/26 1. Cannot see connection due to it being covered with water/dirt FBC(A) 110.1
DRYWALL NAILING 04/22/2026 APPROVED MCONTRYMAN
INSULATION 04/17/2026 APPROVED MCONTRYMAN
Note: Inspector Notes from Inspection 2420 4/15/26 1. Several anchor bolts are still not tightened. If not done by insulation there will be automatic failure and fee 2. Duct layout needs to be changed to match what has been installed, by final 3. Need nail plate for water closet line in suite bathroom
LATH/BRICK/ WATER BARRIER 04/16/2026 APPROVED - AS NOTED MCONTRYMAN
Note: 4/16/26 2. Duct layout needs to be changed to match what has been installed, by final 3. Need nail plate for water closet line in suite bathroom Inspector Notes from Inspection 2420 4/15/26 1. Several anchor bolts are still not tightened. If not done by insulation there will be automatic failure and fee 2. Duct layout needs to be changed to match what has been installed, by final 3. Need nail plate for water closet line in suite bathroom
ALL ROUGH 04/15/2026 APPROVED - AS NOTED MCONTRYMAN
Note: 4/15/26 1. Several anchor bolts are still not tightened. If not done by insulation there will be automatic failure and fee 2. Duct layout needs to be changed to match what has been installed, by final 3. Need nail plate for water closet line in suite bathroom
ROOF VALLEY & METAL 04/07/2026 APPROVED MCONTRYMAN
ROOF SHEATHING / BRACES/TIES/DOWN CELL 04/06/2026 APPROVED - AS NOTED MCONTRYMAN
Note: 4/6/26 1. Still have 2 loose anchor bolts in load bearing wall --garage door bucks installed later 4/1/2026 - PREVIOUS INSPECTION NOTES 4/1/26 1. Missing overframing tie downs on truss T19 and T20 2. Missing atticc access in WIC in owners suite 3. Anchor bolts on load bearing wall are not fastened down properly 4. Load bearing wall needs to be 12" OC per plan 5. Missing anchor bolt on end of 2x on load bearing wall (marked x/ab) 6. Missing both sun tunnell access in roof sheathing 7. Missing 1 Meta 18 strap on truss T44 (left side) 8. Garage door bucks not installed --Roof sheathing is good Inspector Notes from Inspection 2340 3/20/26 1. 5' Head test was empty again at time of inspection. CM was notified with phone call and inspection report on 3/11. Please have this in order for next inspection or automatic failure will occur (was full on 3/10, empty on 3/11 and empty again on 3/20) Inspector Notes from Inspection 2250 3/11/26 May want to check 5' Head test as it was full, to the top, during inspection on 3/10/26, and now its almost empty
WALL SHEATHING 04/01/2026 APPROVED MCONTRYMAN
Note: Inspector Notes from Inspection 2340 3/20/26 1. 5' Head test was empty again at time of inspection. CM was notified with phone call and inspection report on 3/11. Please have this in order for next inspection or automatic failure will occur (was full on 3/10, empty on 3/11 and empty again on 3/20) Inspector Notes from Inspection 2250 3/11/26 May want to check 5' Head test as it was full, to the top, during inspection on 3/10/26, and now its almost empty
ROOF SHEATHING / BRACES/TIES/DOWN CELL 04/01/2026 Disapproved -FEE REQUIRED MCONTRYMAN
Note: 4/1/26 1. Missing overframing tie downs on truss T19 and T20 2. Missing atticc access in WIC in owners suite 3. Anchor bolts on load bearing wall are not fastened down properly 4. Load bearing wall needs to be 12" OC per plan 5. Missing anchor bolt on end of 2x on load bearing wall (marked x/ab) 6. Missing both sun tunnell access in roof sheathing 7. Missing 1 Meta 18 strap on truss T44 (left side) 8. Garage door bucks not installed --Roof sheathing is good Inspector Notes from Inspection 2340 3/20/26 1. 5' Head test was empty again at time of inspection. CM was notified with phone call and inspection report on 3/11. Please have this in order for next inspection or automatic failure will occur (was full on 3/10, empty on 3/11 and empty again on 3/20) Inspector Notes from Inspection 2250 3/11/26 May want to check 5' Head test as it was full, to the top, during inspection on 3/10/26, and now its almost empty
TIE BEAM / LINTEL 03/20/2026 APPROVED - AS NOTED MCONTRYMAN
Note: 3/20/26 1. 5' Head test was empty again at time of inspection. CM was notified with phone call and inspection report on 3/11. Please have this in order for next inspection or automatic failure will occur (was full on 3/10, empty on 3/11 and empty again on 3/20) Inspector Notes from Inspection 2250 3/11/26 May want to check 5' Head test as it was full, to the top, during inspection on 3/10/26, and now its almost empty
MONOLITHIC SLAB 03/11/2026 APPROVED - AS NOTED MCONTRYMAN
Note: 3/11/26 May want to check 5' Head test as it was full, to the top, during inspection on 3/10/26, and now its almost empty
PLUMBING 1ST ROUGH UNDERGROUND 03/10/2026 APPROVED MCONTRYMAN
Note: 3/9/2026 - PREVIOUS INSPECTION NOTES 3/9/26 1. No water in 5' head test -Water meter installed
PLUMBING 1ST ROUGH UNDERGROUND 03/09/2026 Disapproved - NO FEE MCONTRYMAN
Note: 3/9/26 1. No water in 5' head test -Water meter installed
FORMBOARD SURVEY (OFFICE USE ONLY) 03/06/2026 APPROVED RRICKS
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 03/03/2026 APPROVED CPISCITELLI
WATER METER INSTALLATION REQUEST 02/17/2026 APPROVED ISANDERSON
WILDLIFE CHECK - ENVIRONMENTAL 02/02/2026 APPROVED DRODRIGUEZ
BLD - BUILDING FINAL
ROW - FINAL APRON (AFTER POUR)
ROW - FINAL INSPECTION
U -UTILITY RESIDENTIAL FINAL
U-CROSS CONNECTION

Review History

Department Status Date In Date Out
MECH COMPLETE 04/17/2026 04/20/2026
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 04/13/2026 04/14/2026
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
SW1 COMPLETE 03/06/2026 03/06/2026
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 03/06/2026 03/06/2026
Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM
BLD COMPLETE 03/02/2026 03/03/2026
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ZON COMPLETE 02/10/2026 02/10/2026
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
MECH COMPLETE 02/05/2026 02/10/2026
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ZON HOLD 02/05/2026 02/05/2026
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Correct floor plan : Floor plan: the sq ft is off my system is showing 3978 not 3979
SWALE COMPLETE 01/27/2026 02/03/2026
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
BLD COMPLETE 01/26/2026 01/30/2026
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
CUSVC COMPLETE 01/26/2026 02/04/2026
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 01/26/2026 01/29/2026
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 01/26/2026 01/27/2026
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
GAS CANCEL 01/26/2026 01/27/2026
LOCATE COMPLETE 01/26/2026 01/30/2026
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH HOLD 01/26/2026 01/27/2026
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM State card is page withn the preparers signature. Upload this page as state card.
SW1 COMPLETE 01/26/2026 01/29/2026
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Note: Proposed sloped are the max allowed along on interior swales. Please ensure these slopes are not exceeded during construction to mitigate holds.
ZON HOLD 01/26/2026 02/02/2026
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Survey: Please provide the correct survey for this address. Floor plan: the sq ft is off my system is showing 3978 not 3979
PLENV COMPLETE 01/26/2026 02/02/2026
Note: Released By: DYLAN RODRIGUEZ - (386)986-2320 - DRODRIGUEZ@PALMCOASTGOV.COM Staff conducted a site visit on 02/02/26 and found no Gopher Tortoise or their burrows. Staff suggests placing silt fence as soon as possible to prevent tortoise from moving into the lot. If any gopher tortoises are located in the future further coordination may be necessary.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
FC IMPACT FEE EMS ¤62.00 02/11/2026
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 02/11/2026
FC IMPACT FEE LIBRARY ¤268.00 02/11/2026
FIRE RES IMPACT FEE 10-25 ¤942.00 02/11/2026
PARKS IMPACT FEE 10-25 ¤3,164.00 02/11/2026
RSI DRIVEWAY AFTER POUR ¤16.25 02/11/2026
RSE DRIVE PRE POUR INSPECTION ¤32.50 02/11/2026
RSI FIELD SURVEY INSPECTION ¤48.75 02/11/2026
RSI FORMBOARD REVIEW ¤16.25 02/11/2026
RSI PLAN REVIEW NEW ¤48.75 02/11/2026
RSI FNL SURVEY/GRADING CERT ¤48.75 02/11/2026
RSI ROW FINAL INSPECTION ¤16.25 02/11/2026
SCHOOL BOARD IMPACT FEE RES ¤5,450.00 02/11/2026
WASTEWATER MAIN EXTENSION IMPA ¤2,385.00 02/11/2026
SURCHARGE FS 533.721 ¤21.30 02/11/2026
SURCHARGE - FS 468.631 ¤31.96 02/11/2026
SW ENG RES REVIEW 240 ¤240.00 02/11/2026
WATER METER W/ TAP ¤2,326.93 02/11/2026
TRANSP RES IMPACT FEE 10-25 ¤11,841.57 02/11/2026
WASTEWATER PERM INSPECTION ¤80.00 02/11/2026
WASTEWATER PERM REVIEW ¤25.00 02/11/2026
SEWER CAPITAL FACILITY ¤4,415.00 02/11/2026
WATER CAPITAL FACILITY FEE ¤3,790.49 02/11/2026
WATER PERMIT REVIEW ¤25.00 02/11/2026
WATER MAIN EXTENSION IMPACT ¤917.27 02/11/2026
SITE PLAN 30 ¤30.00 02/11/2026
WATER- TURN ON ¤50.00 02/11/2026
ADMINISTRATIVE RESIDENTIAL ¤30.00 02/11/2026
INSPECTION - RESIDENTIAL ¤1,636.25 02/11/2026
PLAN REVIEW - RESIDENTIAL ¤464.10 02/11/2026
PLAN REVIEW - REVISION ¤32.50
PLAN REVIEW - REVISION ¤32.50
REINSPECTION RESIDENTIAL ¤40.00
Fees Total Due: ¤105.00 Total Paid: ¤38,641.37