I want to search for...
Permit #2026010967
Permit Details
Status: COED
| Parcel Id: 04-11-30-5570-00000-1570 |
| CONDITIONED SPACE: 1221 sqft |
| GARAGE: 420 sqft |
| OPENED PORCH (WITH ROOF) : 31 sqft |
| OPENED PORCH (WITH ROOF) : 120 sqft |
| Total Square Footage: 1792 sqft |
| Subdivision: 2326 - SOMERSET SUBDIVISION PH 1 |
| Job Phone: 904-596-6645 |
| Location Address: 36 TEA OLIVE DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 02/09/2026 |
| NOC: RECORDED |
| Applicant name: MICHAEL T HOLDER |
| Owner: KB HOME JACKSONVILLE LLC |
|
Address 10475 FORTUNE PARKWAY JACKSONVILLE, FL 32256 |
|
Address SUITE 100 JACKSONVILLE, FL 32256 |
| Lot: 157 |
| Contracted Stated Job Value: ¤140,000.00 |
| Job Description: NEW SINGLE FAMILY DWELLING |
| Type: CN |
Contractor
KB HOME JACKSONVILLE, LLC
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
10475 FORTUNE PKWY JACKSONVILLE, FL 32256 |
SUITE 100 JACKSONVILLE, FL 32256 |
CGC1509034 (Exp: 08/31/2026) | 904-596-6645 |
Sub Contractors
BOBBY WAYNE CAMPBELL
| Status | Location Address | State License Number | Phone |
| ACTIVE |
117 GUTHRIE ROAD GREEN COVE SPRINGS, FL 32043 |
CCC1326752 (Exp: 08/31/2026) | 904-200-1600 |
LARRY WILLIAMS
| Status | Location Address | State License Number | Phone |
| ACTIVE |
1750 EMERSON ST JACKSONVILLE, FL 32207 |
LI45034 (Exp: 08/31/2026) | 904-721-5431 |
JAMES E LINTON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
200 COLLEGE DR ORANGE PARK, FL 32065 |
EC0001152 (Exp: 08/31/2026) | 904-272-0272 |
COREY MICHAEL TENNANT
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3370 AGRICULTURAL CNETER DR ST AUGUSTINE, FL 32092 |
CAC1819063 (Exp: 08/31/2026) | 904-829-8898 |
BENJAMIN MICHAEL RAY
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| ACTIVE |
6310 MABLETON PKWY JACKSONVILLE, FL 32216 |
SUITE 1000 MABLETON, GA 30126 |
CFC1428415 (Exp: 08/31/2026) | 904-861-5421 | 904-861-5426 |
Inspection History
| Type | Request Date | Result | Inspector |
| ROW - FINAL APRON (AFTER POUR) | 05/21/2026 | APPROVED | EMADISON |
| Note: ** AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW - FINAL INSPECTION | 05/21/2026 | APPROVED | EMADISON |
| Note: ** AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| U -UTILITY RESIDENTIAL FINAL | 05/21/2026 | FINAL APPROVED | BHAINES |
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 05/20/2026 | APPROVED | TPOLACEK |
| Note: BASED ON THE ENGINEERS SIGNED AND SEALED LGDC MEETING THE COPC MINIMUM REQUIREMENTS AT THE TIME OF THIS INSPECTION, I AM APPROVING THIS DOCUMENT. Effective 03-25-26, the ROW Field Survey requirement is no longer in effect for Final Lot Grading and Drainage Certificates for new construction on subdivision and infill lots. All Final Lot Grading and Drainage Certificates for these projects will now be reviewed and approved only in the office. Field verification for the ROW-FIELD SURVEY will no longer be required as part of the standard approval process for these permit types 5/19/2026 - PREVIOUS INSPECTION NOTES THE FINAL SURVEY ATTACHED TO THE LGDC IS FOR #10 AND NOT #36 PLEASE ATTACH THE CORRECT SURVEY | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 05/20/2026 | APPROVED | TPOLACEK |
| Note: DUPLICATE INSPECTION 5/19/2026 7:24:46 AM- PREVIOUS INSPECTION NOTES INSPECTION APPROVED BY MISTAKE. THE FINAL SURVEY ATTACHED TO LGDC IS FOR #10 TEA OLIVE NOT 36 TPOLACEK BASED ON THE ENGINEERS SIGNED AND SEALED LGDC MEETING THE COPC MINIMUM REQUIREMENTS AT THE TIME OF THIS INSPECTION, I AM APPROVING THIS DOCUMENT. Effective 03-25-26, the ROW Field Survey requirement is no longer in effect for Final Lot Grading and Drainage Certificates for new construction on subdivision and infill lots. All Final Lot Grading and Drainage Certificates for these projects will now be reviewed and approved only in the office. Field verification for the ROW-FIELD SURVEY will no longer be required as part of the standard approval process for these permit types | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 05/19/2026 | Disapproved - NO FEE | TPOLACEK |
| Note: INSPECTION APPROVED BY MISTAKE. THE FINAL SURVEY ATTACHED TO LGDC IS FOR #10 TEA OLIVE NOT 36 TPOLACEK BASED ON THE ENGINEERS SIGNED AND SEALED LGDC MEETING THE COPC MINIMUM REQUIREMENTS AT THE TIME OF THIS INSPECTION, I AM APPROVING THIS DOCUMENT. Effective 03-25-26, the ROW Field Survey requirement is no longer in effect for Final Lot Grading and Drainage Certificates for new construction on subdivision and infill lots. All Final Lot Grading and Drainage Certificates for these projects will now be reviewed and approved only in the office. Field verification for the ROW-FIELD SURVEY will no longer be required as part of the standard approval process for these permit types | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 05/19/2026 | Disapproved - NO FEE | TPOLACEK |
| Note: THE FINAL SURVEY ATTACHED TO THE LGDC IS FOR #10 AND NOT #36 PLEASE ATTACH THE CORRECT SURVEY | |||
| BLD - BUILDING FINAL | 05/12/2026 | FINAL APPROVED | JSTEWART |
| Note: 5/8/2026 - PREVIOUS INSPECTION NOTES 1. Sewer clean out at exterior garage wall needs a service cap. FBPC 708.1.6 2. Secure liquid tight at tug receptacle. NEC 352.30(A) 3. Exterior exhaust terminations need screens (not dryer). 4. Raise AC pad, for 3" clearence from surrounding ground. FBCR M1305.1.4.1 5. exterior receptacle at AC condensor needs a face plate and a weather box cover. NEC 406.9. 6. Locking caps at Condensor need locked. FBCR M1411.8 7. Master bedroom receptacles have a open ground. NEC 406.3(D) 8. Master bath and spare bath requires GFCI protection. NEC 210.8 | |||
| U-CROSS CONNECTION | 05/08/2026 | APPROVED | BWRIGHT |
| BLD - BUILDING FINAL | 05/08/2026 | Disapproved -FEE REQUIRED | JSTEWART |
| Note: 1. Sewer clean out at exterior garage wall needs a service cap. FBPC 708.1.6 2. Secure liquid tight at tug receptacle. NEC 352.30(A) 3. Exterior exhaust terminations need screens (not dryer). 4. Raise AC pad, for 3" clearence from surrounding ground. FBCR M1305.1.4.1 5. exterior receptacle at AC condensor needs a face plate and a weather box cover. NEC 406.9. 6. Locking caps at Condensor need locked. FBCR M1411.8 7. Master bedroom receptacles have a open ground. NEC 406.3(D) 8. Master bath and spare bath requires GFCI protection. NEC 210.8 | |||
| ELECTRIC - EARLY POWER | 04/17/2026 | APPROVED | JSTEWART |
| ROW- PRE-APRON (PRE-POUR) | 04/01/2026 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. . TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, IN THE UPCOMING MONTHS THE DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS WILL BE REQUIRED TO BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. YOU WILL RECEIVE A NEWS BLAST WHEN THIS BECOMES NECESSARY | |||
| DRYWALL NAILING | 03/25/2026 | APPROVED | JSTEWART |
| INSULATION | 03/23/2026 | APPROVED | JSTEWART |
| Note: Inspector Notes from Inspection 2320 Disreguard previous finding for this inpsection and fee was reversed, error in typing. Lath is approved. 3/20/2026 - PREVIOUS INSPECTION NOTES Previous notes not rectified..... 3. Bath fans need two point connection. FBC M1601.4.1 (Mechanical faster at exhaust duct to fan assembly.) 4. Seal unused openings. NEC 110.12(a) (unsused opening at breaker panel, please use approved cap). Inspector Notes from Inspection 2420 1. No water pressure. FBCR P2503.5 2. 5 Ft head test. FBCR P2503.7 3. Bath fans need two point connection. FBC M1601.4.1 4. Seal unused openings. NEC 110.12(a) 5. Dryer vent needs to be sealed at roof deck. 6. House to Garage door gap more than 1/4" at top. FBCR 609.1 7. Sliders installed do not match Product Approval. Please revise. To be checked at next insulation. | |||
| INSULATION | 03/20/2026 | Disapproved -FEE REQUIRED | JSTEWART |
| Note: Previous notes not rectified..... 3. Bath fans need two point connection. FBC M1601.4.1 (Mechanical faster at exhaust duct to fan assembly.) 4. Seal unused openings. NEC 110.12(a) (unsused opening at breaker panel, please use approved cap). Inspector Notes from Inspection 2420 1. No water pressure. FBCR P2503.5 2. 5 Ft head test. FBCR P2503.7 3. Bath fans need two point connection. FBC M1601.4.1 4. Seal unused openings. NEC 110.12(a) 5. Dryer vent needs to be sealed at roof deck. 6. House to Garage door gap more than 1/4" at top. FBCR 609.1 7. Sliders installed do not match Product Approval. Please revise. To be checked at next insulation. | |||
| LATH/BRICK/ WATER BARRIER | 03/20/2026 | Disapproved -FEE REQUIRED | JSTEWART |
| Note: Previous notes not rectified..... 3. Bath fans need two point connection. FBC M1601.4.1 (Mechanical faster at exhaust duct to fan assembly.) 4. Seal unused openings. NEC 110.12(a) (unsused opening at breaker panel, please use approved cap). Inspector Notes from Inspection 2420 1. No water pressure. FBCR P2503.5 2. 5 Ft head test. FBCR P2503.7 3. Bath fans need two point connection. FBC M1601.4.1 4. Seal unused openings. NEC 110.12(a) 5. Dryer vent needs to be sealed at roof deck. 6. House to Garage door gap more than 1/4" at top. FBCR 609.1 7. Sliders installed do not match Product Approval. Please revise. To be checked at next insulation. | |||
| LATH/BRICK/ WATER BARRIER | 03/20/2026 | APPROVED - AS NOTED | JSTEWART |
| Note: Disreguard previous finding for this inpsection and fee was reversed, error in typing. Lath is approved. 3/20/2026 - PREVIOUS INSPECTION NOTES Previous notes not rectified..... 3. Bath fans need two point connection. FBC M1601.4.1 (Mechanical faster at exhaust duct to fan assembly.) 4. Seal unused openings. NEC 110.12(a) (unsused opening at breaker panel, please use approved cap). Inspector Notes from Inspection 2420 1. No water pressure. FBCR P2503.5 2. 5 Ft head test. FBCR P2503.7 3. Bath fans need two point connection. FBC M1601.4.1 4. Seal unused openings. NEC 110.12(a) 5. Dryer vent needs to be sealed at roof deck. 6. House to Garage door gap more than 1/4" at top. FBCR 609.1 7. Sliders installed do not match Product Approval. Please revise. To be checked at next insulation. | |||
| ALL ROUGH | 03/17/2026 | APPROVED - AS NOTED | PKNAPIK |
| Note: 1. No water pressure. FBCR P2503.5 2. 5 Ft head test. FBCR P2503.7 3. Bath fans need two point connection. FBC M1601.4.1 4. Seal unused openings. NEC 110.12(a) 5. Dryer vent needs to be sealed at roof deck. 6. House to Garage door gap more than 1/4" at top. FBCR 609.1 7. Sliders installed do not match Product Approval. Please revise. To be checked at next insulation. | |||
| ELECTRIC-TUG | 03/17/2026 | APPROVED | PKNAPIK |
| ROOF VALLEY & METAL | 03/11/2026 | APPROVED | JSTEWART |
| WALL SHEATHING | 03/09/2026 | APPROVED | JSTEWART |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 03/09/2026 | APPROVED | JSTEWART |
| GRAVITY SEWER TEST | 02/26/2026 | APPROVED | JSTEWART |
| SEWER TIE IN | 02/26/2026 | APPROVED | JSTEWART |
| MONOLITHIC SLAB | 02/24/2026 | APPROVED | JSTEWART |
| WATER METER INSTALLATION REQUEST | 02/24/2026 | APPROVED | ISANDERSON |
| PLUMBING 1ST ROUGH UNDERGROUND | 02/20/2026 | APPROVED | JSTEWART |
| FORMBOARD SURVEY (OFFICE USE ONLY) | 02/18/2026 | APPROVED | RRICKS |
| FORMBOARD SURVEY (OFFICE USE ONLY) | 02/18/2026 | APPROVED | RRICKS |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 05/20/2026 | 05/20/2026 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| BLD | HOLD | 03/19/2026 | 03/23/2026 |
| Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM FL# 15297.3 not valid | |||
| SW1 | COMPLETE | 02/18/2026 | 02/18/2026 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 02/18/2026 | 02/18/2026 |
| Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 02/18/2026 | 02/18/2026 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 01/29/2026 | 02/04/2026 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 01/29/2026 | 02/05/2026 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 01/29/2026 | 02/03/2026 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 01/29/2026 | 01/30/2026 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| GAS | COMPLETE | 01/29/2026 | 01/30/2026 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 01/29/2026 | 02/02/2026 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 01/29/2026 | 01/30/2026 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 01/29/2026 | 02/02/2026 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 01/29/2026 | 02/03/2026 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| URB | COMPLETE | 01/29/2026 | 02/02/2026 |
| Note: Released By: JOHN BEAUDET - (386)986-2456 - JBEAUDET@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| PLAN REVIEW - REVISION | ¤32.50 | 05/20/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 05/20/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 05/20/2026 |
| FC IMPACT FEE EMS | ¤62.00 | 02/09/2026 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 02/09/2026 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 02/09/2026 |
| FIRE RES IMPACT FEE 10-25 | ¤942.00 | 02/09/2026 |
| WATER METER W/OUT TAP | ¤965.03 | 02/09/2026 |
| PARKS IMPACT FEE 10-25 | ¤3,164.00 | 02/09/2026 |
| RECLAIM WATER PERMIT INSPECTIO | ¤40.00 | 02/09/2026 |
| RSI DRIVEWAY AFTER POUR | ¤16.25 | 02/09/2026 |
| RSE DRIVE PRE POUR INSPECTION | ¤32.50 | 02/09/2026 |
| RSI FIELD SURVEY INSPECTION | ¤48.75 | 02/09/2026 |
| RSI FORMBOARD REVIEW | ¤16.25 | 02/09/2026 |
| RSI PLAN REVIEW NEW | ¤48.75 | 02/09/2026 |
| RSI FNL SURVEY/GRADING CERT | ¤48.75 | 02/09/2026 |
| RSI ROW FINAL INSPECTION | ¤16.25 | 02/09/2026 |
| SCHOOL BOARD IMPACT FEE RES | ¤5,450.00 | 02/09/2026 |
| SURCHARGE FS 533.721 | ¤9.09 | 02/09/2026 |
| SURCHARGE - FS 468.631 | ¤13.64 | 02/09/2026 |
| TRANSP RES IMPACT FEE 10-25 | ¤4,603.17 | 02/09/2026 |
| WASTEWATER PERM INSPECTION | ¤80.00 | 02/09/2026 |
| WASTEWATER PERM REVIEW | ¤25.00 | 02/09/2026 |
| SEWER CAPITAL FACILITY | ¤3,737.90 | 02/09/2026 |
| WATER CAPITAL FACILITY FEE | ¤3,161.82 | 02/09/2026 |
| WATER PERMIT REVIEW | ¤25.00 | 02/09/2026 |
| SITE PLAN 30 | ¤30.00 | 02/09/2026 |
| WATER-METER | ¤874.47 | 02/09/2026 |
| WATER- TURN ON | ¤50.00 | 02/09/2026 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 02/09/2026 |
| INSPECTION - RESIDENTIAL | ¤684.75 | 02/09/2026 |
| PLAN REVIEW - RESIDENTIAL | ¤194.22 | 02/09/2026 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤24,968.09 |