I want to search for...

Permit #2026010967

Permit Details

Status: COED

Parcel Id: 04-11-30-5570-00000-1570
CONDITIONED SPACE: 1221 sqft
GARAGE: 420 sqft
OPENED PORCH (WITH ROOF) : 31 sqft
OPENED PORCH (WITH ROOF) : 120 sqft
Total Square Footage: 1792 sqft
Subdivision: 2326 - SOMERSET SUBDIVISION PH 1
Job Phone: 904-596-6645
Location Address: 36 TEA OLIVE DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 02/09/2026
NOC: RECORDED
Applicant name: MICHAEL T HOLDER
Owner: KB HOME JACKSONVILLE LLC

Address

10475 FORTUNE PARKWAY

JACKSONVILLE, FL 32256

Address

SUITE 100

JACKSONVILLE, FL 32256

Lot: 157
Contracted Stated Job Value: ¤140,000.00
Job Description: NEW SINGLE FAMILY DWELLING
Type: CN

Contractor

KB HOME JACKSONVILLE, LLC
Status Location Address Mailing Address State License Number Phone
ACTIVE

10475 FORTUNE PKWY

JACKSONVILLE, FL 32256

SUITE 100

JACKSONVILLE, FL 32256

CGC1509034 (Exp: 08/31/2026) 904-596-6645

Sub Contractors

BOBBY WAYNE CAMPBELL
Status Location Address State License Number Phone
ACTIVE

117 GUTHRIE ROAD

GREEN COVE SPRINGS, FL 32043

CCC1326752 (Exp: 08/31/2026) 904-200-1600
LARRY WILLIAMS
Status Location Address State License Number Phone
ACTIVE

1750 EMERSON ST

JACKSONVILLE, FL 32207

LI45034 (Exp: 08/31/2026) 904-721-5431
JAMES E LINTON
Status Location Address State License Number Phone
ACTIVE

200 COLLEGE DR

ORANGE PARK, FL 32065

EC0001152 (Exp: 08/31/2026) 904-272-0272
COREY MICHAEL TENNANT
Status Location Address State License Number Phone
ACTIVE

3370 AGRICULTURAL CNETER DR

ST AUGUSTINE, FL 32092

CAC1819063 (Exp: 08/31/2026) 904-829-8898
BENJAMIN MICHAEL RAY
Status Location Address Mailing Address State License Number Phone Fax
ACTIVE

6310 MABLETON PKWY

JACKSONVILLE, FL 32216

SUITE 1000

MABLETON, GA 30126

CFC1428415 (Exp: 08/31/2026) 904-861-5421 904-861-5426

Inspection History

Type Request Date Result Inspector
ROW - FINAL APRON (AFTER POUR) 05/21/2026 APPROVED EMADISON
Note: ** AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW - FINAL INSPECTION 05/21/2026 APPROVED EMADISON
Note: ** AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
U -UTILITY RESIDENTIAL FINAL 05/21/2026 FINAL APPROVED BHAINES
ROW- FINAL SURVEY/GRADING CERTIFICATION 05/20/2026 APPROVED TPOLACEK
Note: BASED ON THE ENGINEERS SIGNED AND SEALED LGDC MEETING THE COPC MINIMUM REQUIREMENTS AT THE TIME OF THIS INSPECTION, I AM APPROVING THIS DOCUMENT. Effective 03-25-26, the ROW Field Survey requirement is no longer in effect for Final Lot Grading and Drainage Certificates for new construction on subdivision and infill lots. All Final Lot Grading and Drainage Certificates for these projects will now be reviewed and approved only in the office. Field verification for the ROW-FIELD SURVEY will no longer be required as part of the standard approval process for these permit types 5/19/2026 - PREVIOUS INSPECTION NOTES THE FINAL SURVEY ATTACHED TO THE LGDC IS FOR #10 AND NOT #36 PLEASE ATTACH THE CORRECT SURVEY
ROW- FINAL SURVEY/GRADING CERTIFICATION 05/20/2026 APPROVED TPOLACEK
Note: DUPLICATE INSPECTION 5/19/2026 7:24:46 AM- PREVIOUS INSPECTION NOTES INSPECTION APPROVED BY MISTAKE. THE FINAL SURVEY ATTACHED TO LGDC IS FOR #10 TEA OLIVE NOT 36 TPOLACEK BASED ON THE ENGINEERS SIGNED AND SEALED LGDC MEETING THE COPC MINIMUM REQUIREMENTS AT THE TIME OF THIS INSPECTION, I AM APPROVING THIS DOCUMENT. Effective 03-25-26, the ROW Field Survey requirement is no longer in effect for Final Lot Grading and Drainage Certificates for new construction on subdivision and infill lots. All Final Lot Grading and Drainage Certificates for these projects will now be reviewed and approved only in the office. Field verification for the ROW-FIELD SURVEY will no longer be required as part of the standard approval process for these permit types
ROW- FINAL SURVEY/GRADING CERTIFICATION 05/19/2026 Disapproved - NO FEE TPOLACEK
Note: INSPECTION APPROVED BY MISTAKE. THE FINAL SURVEY ATTACHED TO LGDC IS FOR #10 TEA OLIVE NOT 36 TPOLACEK BASED ON THE ENGINEERS SIGNED AND SEALED LGDC MEETING THE COPC MINIMUM REQUIREMENTS AT THE TIME OF THIS INSPECTION, I AM APPROVING THIS DOCUMENT. Effective 03-25-26, the ROW Field Survey requirement is no longer in effect for Final Lot Grading and Drainage Certificates for new construction on subdivision and infill lots. All Final Lot Grading and Drainage Certificates for these projects will now be reviewed and approved only in the office. Field verification for the ROW-FIELD SURVEY will no longer be required as part of the standard approval process for these permit types
ROW- FINAL SURVEY/GRADING CERTIFICATION 05/19/2026 Disapproved - NO FEE TPOLACEK
Note: THE FINAL SURVEY ATTACHED TO THE LGDC IS FOR #10 AND NOT #36 PLEASE ATTACH THE CORRECT SURVEY
BLD - BUILDING FINAL 05/12/2026 FINAL APPROVED JSTEWART
Note: 5/8/2026 - PREVIOUS INSPECTION NOTES 1. Sewer clean out at exterior garage wall needs a service cap. FBPC 708.1.6 2. Secure liquid tight at tug receptacle. NEC 352.30(A) 3. Exterior exhaust terminations need screens (not dryer). 4. Raise AC pad, for 3" clearence from surrounding ground. FBCR M1305.1.4.1 5. exterior receptacle at AC condensor needs a face plate and a weather box cover. NEC 406.9. 6. Locking caps at Condensor need locked. FBCR M1411.8 7. Master bedroom receptacles have a open ground. NEC 406.3(D) 8. Master bath and spare bath requires GFCI protection. NEC 210.8
U-CROSS CONNECTION 05/08/2026 APPROVED BWRIGHT
BLD - BUILDING FINAL 05/08/2026 Disapproved -FEE REQUIRED JSTEWART
Note: 1. Sewer clean out at exterior garage wall needs a service cap. FBPC 708.1.6 2. Secure liquid tight at tug receptacle. NEC 352.30(A) 3. Exterior exhaust terminations need screens (not dryer). 4. Raise AC pad, for 3" clearence from surrounding ground. FBCR M1305.1.4.1 5. exterior receptacle at AC condensor needs a face plate and a weather box cover. NEC 406.9. 6. Locking caps at Condensor need locked. FBCR M1411.8 7. Master bedroom receptacles have a open ground. NEC 406.3(D) 8. Master bath and spare bath requires GFCI protection. NEC 210.8
ELECTRIC - EARLY POWER 04/17/2026 APPROVED JSTEWART
ROW- PRE-APRON (PRE-POUR) 04/01/2026 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. . TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, IN THE UPCOMING MONTHS THE DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS WILL BE REQUIRED TO BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. YOU WILL RECEIVE A NEWS BLAST WHEN THIS BECOMES NECESSARY
DRYWALL NAILING 03/25/2026 APPROVED JSTEWART
INSULATION 03/23/2026 APPROVED JSTEWART
Note: Inspector Notes from Inspection 2320 Disreguard previous finding for this inpsection and fee was reversed, error in typing. Lath is approved. 3/20/2026 - PREVIOUS INSPECTION NOTES Previous notes not rectified..... 3. Bath fans need two point connection. FBC M1601.4.1 (Mechanical faster at exhaust duct to fan assembly.) 4. Seal unused openings. NEC 110.12(a) (unsused opening at breaker panel, please use approved cap). Inspector Notes from Inspection 2420 1. No water pressure. FBCR P2503.5 2. 5 Ft head test. FBCR P2503.7 3. Bath fans need two point connection. FBC M1601.4.1 4. Seal unused openings. NEC 110.12(a) 5. Dryer vent needs to be sealed at roof deck. 6. House to Garage door gap more than 1/4" at top. FBCR 609.1 7. Sliders installed do not match Product Approval. Please revise. To be checked at next insulation.
INSULATION 03/20/2026 Disapproved -FEE REQUIRED JSTEWART
Note: Previous notes not rectified..... 3. Bath fans need two point connection. FBC M1601.4.1 (Mechanical faster at exhaust duct to fan assembly.) 4. Seal unused openings. NEC 110.12(a) (unsused opening at breaker panel, please use approved cap). Inspector Notes from Inspection 2420 1. No water pressure. FBCR P2503.5 2. 5 Ft head test. FBCR P2503.7 3. Bath fans need two point connection. FBC M1601.4.1 4. Seal unused openings. NEC 110.12(a) 5. Dryer vent needs to be sealed at roof deck. 6. House to Garage door gap more than 1/4" at top. FBCR 609.1 7. Sliders installed do not match Product Approval. Please revise. To be checked at next insulation.
LATH/BRICK/ WATER BARRIER 03/20/2026 Disapproved -FEE REQUIRED JSTEWART
Note: Previous notes not rectified..... 3. Bath fans need two point connection. FBC M1601.4.1 (Mechanical faster at exhaust duct to fan assembly.) 4. Seal unused openings. NEC 110.12(a) (unsused opening at breaker panel, please use approved cap). Inspector Notes from Inspection 2420 1. No water pressure. FBCR P2503.5 2. 5 Ft head test. FBCR P2503.7 3. Bath fans need two point connection. FBC M1601.4.1 4. Seal unused openings. NEC 110.12(a) 5. Dryer vent needs to be sealed at roof deck. 6. House to Garage door gap more than 1/4" at top. FBCR 609.1 7. Sliders installed do not match Product Approval. Please revise. To be checked at next insulation.
LATH/BRICK/ WATER BARRIER 03/20/2026 APPROVED - AS NOTED JSTEWART
Note: Disreguard previous finding for this inpsection and fee was reversed, error in typing. Lath is approved. 3/20/2026 - PREVIOUS INSPECTION NOTES Previous notes not rectified..... 3. Bath fans need two point connection. FBC M1601.4.1 (Mechanical faster at exhaust duct to fan assembly.) 4. Seal unused openings. NEC 110.12(a) (unsused opening at breaker panel, please use approved cap). Inspector Notes from Inspection 2420 1. No water pressure. FBCR P2503.5 2. 5 Ft head test. FBCR P2503.7 3. Bath fans need two point connection. FBC M1601.4.1 4. Seal unused openings. NEC 110.12(a) 5. Dryer vent needs to be sealed at roof deck. 6. House to Garage door gap more than 1/4" at top. FBCR 609.1 7. Sliders installed do not match Product Approval. Please revise. To be checked at next insulation.
ALL ROUGH 03/17/2026 APPROVED - AS NOTED PKNAPIK
Note: 1. No water pressure. FBCR P2503.5 2. 5 Ft head test. FBCR P2503.7 3. Bath fans need two point connection. FBC M1601.4.1 4. Seal unused openings. NEC 110.12(a) 5. Dryer vent needs to be sealed at roof deck. 6. House to Garage door gap more than 1/4" at top. FBCR 609.1 7. Sliders installed do not match Product Approval. Please revise. To be checked at next insulation.
ELECTRIC-TUG 03/17/2026 APPROVED PKNAPIK
ROOF VALLEY & METAL 03/11/2026 APPROVED JSTEWART
WALL SHEATHING 03/09/2026 APPROVED JSTEWART
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/09/2026 APPROVED JSTEWART
GRAVITY SEWER TEST 02/26/2026 APPROVED JSTEWART
SEWER TIE IN 02/26/2026 APPROVED JSTEWART
MONOLITHIC SLAB 02/24/2026 APPROVED JSTEWART
WATER METER INSTALLATION REQUEST 02/24/2026 APPROVED ISANDERSON
PLUMBING 1ST ROUGH UNDERGROUND 02/20/2026 APPROVED JSTEWART
FORMBOARD SURVEY (OFFICE USE ONLY) 02/18/2026 APPROVED RRICKS
FORMBOARD SURVEY (OFFICE USE ONLY) 02/18/2026 APPROVED RRICKS

Review History

Department Status Date In Date Out
BLD COMPLETE 05/20/2026 05/20/2026
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
BLD HOLD 03/19/2026 03/23/2026
Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM FL# 15297.3 not valid
SW1 COMPLETE 02/18/2026 02/18/2026
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 02/18/2026 02/18/2026
Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM
SW1 COMPLETE 02/18/2026 02/18/2026
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
BLD COMPLETE 01/29/2026 02/04/2026
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
CUSVC COMPLETE 01/29/2026 02/05/2026
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 01/29/2026 02/03/2026
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 01/29/2026 01/30/2026
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
GAS COMPLETE 01/29/2026 01/30/2026
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
LOCATE COMPLETE 01/29/2026 02/02/2026
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH COMPLETE 01/29/2026 01/30/2026
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 01/29/2026 02/02/2026
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 01/29/2026 02/03/2026
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
URB COMPLETE 01/29/2026 02/02/2026
Note: Released By: JOHN BEAUDET - (386)986-2456 - JBEAUDET@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 05/20/2026
REINSPECTION RESIDENTIAL ¤40.00 05/20/2026
REINSPECTION RESIDENTIAL ¤40.00 05/20/2026
FC IMPACT FEE EMS ¤62.00 02/09/2026
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 02/09/2026
FC IMPACT FEE LIBRARY ¤268.00 02/09/2026
FIRE RES IMPACT FEE 10-25 ¤942.00 02/09/2026
WATER METER W/OUT TAP ¤965.03 02/09/2026
PARKS IMPACT FEE 10-25 ¤3,164.00 02/09/2026
RECLAIM WATER PERMIT INSPECTIO ¤40.00 02/09/2026
RSI DRIVEWAY AFTER POUR ¤16.25 02/09/2026
RSE DRIVE PRE POUR INSPECTION ¤32.50 02/09/2026
RSI FIELD SURVEY INSPECTION ¤48.75 02/09/2026
RSI FORMBOARD REVIEW ¤16.25 02/09/2026
RSI PLAN REVIEW NEW ¤48.75 02/09/2026
RSI FNL SURVEY/GRADING CERT ¤48.75 02/09/2026
RSI ROW FINAL INSPECTION ¤16.25 02/09/2026
SCHOOL BOARD IMPACT FEE RES ¤5,450.00 02/09/2026
SURCHARGE FS 533.721 ¤9.09 02/09/2026
SURCHARGE - FS 468.631 ¤13.64 02/09/2026
TRANSP RES IMPACT FEE 10-25 ¤4,603.17 02/09/2026
WASTEWATER PERM INSPECTION ¤80.00 02/09/2026
WASTEWATER PERM REVIEW ¤25.00 02/09/2026
SEWER CAPITAL FACILITY ¤3,737.90 02/09/2026
WATER CAPITAL FACILITY FEE ¤3,161.82 02/09/2026
WATER PERMIT REVIEW ¤25.00 02/09/2026
SITE PLAN 30 ¤30.00 02/09/2026
WATER-METER ¤874.47 02/09/2026
WATER- TURN ON ¤50.00 02/09/2026
ADMINISTRATIVE RESIDENTIAL ¤30.00 02/09/2026
INSPECTION - RESIDENTIAL ¤684.75 02/09/2026
PLAN REVIEW - RESIDENTIAL ¤194.22 02/09/2026
Fees Total Due: ¤0.00 Total Paid: ¤24,968.09