Permit #2026010972
Permit Details
Status: COED
| Parcel Id: 04-11-30-5571-00000-3030 |
| CONDITIONED SPACE: 1638 sqft |
| GARAGE: 420 sqft |
| OPENED PORCH (WITH ROOF) : 96 sqft |
| OPENED PORCH (WITH ROOF) : 112 sqft |
| Total Square Footage: 2266 sqft |
| Subdivision: 2366 - SOMERSET SUBDIVISION PH 2 |
| Job Phone: 904-596-6645 |
| Location Address: 101 TEA OLIVE DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 02/11/2026 |
| NOC: RECORDED |
| Applicant name: MICHAEL T HOLDER |
| Owner: KB HOME JACKSONVILLE LLC |
|
Address 10475 FORTUNE PARKWAY JACKSONVILLE, FL 32256 |
|
Address SUITE 100 JACKSONVILLE, FL 32256 |
| Lot: 303 |
| Contracted Stated Job Value: ¤140,000.00 |
| Job Description: SINGLE FAMILY DWELLING |
| Type: CN |
Contractor
KB HOME JACKSONVILLE, LLC
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
10475 FORTUNE PKWY JACKSONVILLE, FL 32256 |
SUITE 100 JACKSONVILLE, FL 32256 |
CGC1509034 (Exp: 08/31/2026) | 904-596-6645 |
Sub Contractors
BOBBY WAYNE CAMPBELL
| Status | Location Address | State License Number | Phone |
| ACTIVE |
117 GUTHRIE ROAD GREEN COVE SPRINGS, FL 32043 |
CCC1326752 (Exp: 08/31/2026) | 904-200-1600 |
LARRY WILLIAMS
| Status | Location Address | State License Number | Phone |
| ACTIVE |
1750 EMERSON ST JACKSONVILLE, FL 32207 |
LI45034 (Exp: 08/31/2026) | 904-721-5431 |
JAMES E LINTON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
200 COLLEGE DR ORANGE PARK, FL 32065 |
EC0001152 (Exp: 08/31/2026) | 904-272-0272 |
COREY MICHAEL TENNANT
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3370 AGRICULTURAL CNETER DR ST AUGUSTINE, FL 32092 |
CAC1819063 (Exp: 08/31/2026) | 904-829-8898 |
BENJAMIN MICHAEL RAY
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| ACTIVE |
6310 MABLETON PKWY JACKSONVILLE, FL 32216 |
SUITE 1000 MABLETON, GA 30126 |
CFC1428415 (Exp: 08/31/2026) | 904-861-5421 | 904-861-5426 |
Inspection History
| Type | Request Date | Result | Inspector |
| ROW - FINAL APRON (AFTER POUR) | 05/19/2026 | APPROVED - AS NOTED | PFLANAGAN |
| Note: MOVING POD WAS ON DRIVEWAY | |||
| ROW - FINAL INSPECTION | 05/19/2026 | APPROVED | PFLANAGAN |
| Note: At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection. | |||
| U -UTILITY RESIDENTIAL FINAL | 05/19/2026 | FINAL APPROVED | BHAINES |
| U-CROSS CONNECTION | 05/12/2026 | APPROVED | BWRIGHT |
| BLD - BUILDING FINAL | 05/12/2026 | FINAL APPROVED | JSTEWART |
| Note: 5/7/2026 - PREVIOUS INSPECTION NOTES 1. Locking caps need to be secured. 2. Missing trim at left side double window. per plan 3. Seal wall at communication penetrations (exterior) 4. secure liquid tight at tug receptacle. 5. Missing a screw to secure inner face panel at main disconnect. 6. AHU is being worked on (installed) Thermostat not installed unable to inspect. 7. Anti tip bracket. 8. Kitchen hood exhaust duct not installed and needs sealed. | |||
| BLD - BUILDING FINAL | 05/07/2026 | Disapproved -FEE REQUIRED | JSTEWART |
| Note: 1. Locking caps need to be secured. 2. Missing trim at left side double window. per plan 3. Seal wall at communication penetrations (exterior) 4. secure liquid tight at tug receptacle. 5. Missing a screw to secure inner face panel at main disconnect. 6. AHU is being worked on (installed) Thermostat not installed unable to inspect. 7. Anti tip bracket. 8. Kitchen hood exhaust duct not installed and needs sealed. | |||
| ELECTRIC - EARLY POWER | 04/17/2026 | APPROVED - AS NOTED | JSTEWART |
| Note: Authorize release of email. | |||
| ELECTRIC-TUG | 04/17/2026 | CANCELLED BY INSPECTOR | JSTEWART |
| Note: Not needed at Early power stage. | |||
| WINDOW NAILING | 04/17/2026 | APPROVED | JSTEWART |
| Note: NOTE: onsite inspection for Insulation, and water barrier okay to trim. Product approval to complete. 3/30/2026 - PREVIOUS INSPECTION NOTES Anchoring and shim spacing approved. to complete approval, 1. Product approval needs revised, 2. Insulation around the margins. 3. Flashing on exterior around the margins (tape). Inspector Notes from Inspection 2493 Drywall nailing is approved. Added a window nailing inspection for, Original Sliding glass door has been removed, and is being replaced with a french door. Please submit a revision of Product approval for this change. Please dont trim or cover anchors once installed, at window nailing inspection will need to see for the following....Anchoring, water barrier, insulation. | |||
| ROW- PRE-APRON (PRE-POUR) | 04/01/2026 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. . TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, IN THE UPCOMING MONTHS THE DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS WILL BE REQUIRED TO BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. YOU WILL RECEIVE A NEWS BLAST WHEN THIS BECOMES NECESSARY | |||
| WINDOW NAILING | 03/30/2026 | PARTIALLY APPROVED | JSTEWART |
| Note: Anchoring and shim spacing approved. to complete approval, 1. Product approval needs revised, 2. Insulation around the margins. 3. Flashing on exterior around the margins (tape). Inspector Notes from Inspection 2493 Drywall nailing is approved. Added a window nailing inspection for, Original Sliding glass door has been removed, and is being replaced with a french door. Please submit a revision of Product approval for this change. Please dont trim or cover anchors once installed, at window nailing inspection will need to see for the following....Anchoring, water barrier, insulation. | |||
| DRYWALL NAILING | 03/27/2026 | APPROVED - AS NOTED | JSTEWART |
| Note: Drywall nailing is approved. Added a window nailing inspection for, Original Sliding glass door has been removed, and is being replaced with a french door. Please submit a revision of Product approval for this change. Please dont trim or cover anchors once installed, at window nailing inspection will need to see for the following....Anchoring, water barrier, insulation. | |||
| INSULATION | 03/24/2026 | APPROVED | JSTEWART |
| Note: 3/23/2026 - PREVIOUS INSPECTION NOTES Previous note not rectified.....3. Hood exhaust duct lap requires (3) screws. . FBCR M1601.4.1 (Crimp joints for round metal ducts must be mechanically fastened with a minimum of three screws or rivets, equally spaced around the joint.) Inspector Notes from Inspection 2420 1. Gas bonding. FBCR G2411 2. Spare bath exhaust duct adapter needs secured to fan assembly. M1501.1 3. Hood exhaust duct lap requires (3) screws. . FBCR M1601.4.1 Will check at insulation. Water Line tie-in seen on virtual inspection, on 3/12/26 by Michael | |||
| LATH/BRICK/ WATER BARRIER | 03/23/2026 | APPROVED | JSTEWART |
| Note: Inspector Notes from Inspection 2420 1. Gas bonding. FBCR G2411 2. Spare bath exhaust duct adapter needs secured to fan assembly. M1501.1 3. Hood exhaust duct lap requires (3) screws. . FBCR M1601.4.1 Will check at insulation. Water Line tie-in seen on virtual inspection, on 3/12/26 by Michael | |||
| INSULATION | 03/23/2026 | Disapproved - NO FEE | JSTEWART |
| Note: Previous note not rectified.....3. Hood exhaust duct lap requires (3) screws. . FBCR M1601.4.1 (Crimp joints for round metal ducts must be mechanically fastened with a minimum of three screws or rivets, equally spaced around the joint.) Inspector Notes from Inspection 2420 1. Gas bonding. FBCR G2411 2. Spare bath exhaust duct adapter needs secured to fan assembly. M1501.1 3. Hood exhaust duct lap requires (3) screws. . FBCR M1601.4.1 Will check at insulation. Water Line tie-in seen on virtual inspection, on 3/12/26 by Michael | |||
| ALL ROUGH | 03/19/2026 | APPROVED - AS NOTED | JSTEWART |
| Note: 1. Gas bonding. FBCR G2411 2. Spare bath exhaust duct adapter needs secured to fan assembly. M1501.1 3. Hood exhaust duct lap requires (3) screws. . FBCR M1601.4.1 Will check at insulation. Water Line tie-in seen on virtual inspection, on 3/12/26 by Michael | |||
| ROOF VALLEY & METAL | 03/16/2026 | APPROVED | PKNAPIK |
| Note: Inspector Notes from Inspection 2450 | |||
| WALL SHEATHING | 03/12/2026 | APPROVED - AS NOTED | JSTEWART |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 03/12/2026 | APPROVED - AS NOTED | JSTEWART |
| Note: 1. Missing double stud post at girder A16 3 locations (double stud needs to be under the truss). 2. Missing tie downs HTS24's at girder A16 x3 3. Missing 2x4 post at girder B6. 4. Missing tie downs HTS24's at girder B6. 5. Double stud post for girder A15 needs to be directly under the truss. 6. Double stud for Truss B1 needs to be directly under the truss, Both sides. Will check at all rough. | |||
| SEWER TIE IN | 03/12/2026 | APPROVED - AS NOTED | MCONTRYMAN |
| Note: Via Virtual Water Line tied seen in at inspection Inspector Notes from Inspection 2075 Via Virtual Water Line tied seen in at inspection 3/5/2026 - PREVIOUS INSPECTION NOTES 3/5/2026 - PREVIOUS INSPECTION NOTES | |||
| GRAVITY SEWER TEST | 03/12/2026 | APPROVED - AS NOTED | MCONTRYMAN |
| Note: Via Virtual Water Line tied seen in at inspection 3/5/2026 - PREVIOUS INSPECTION NOTES | |||
| SEWER TIE IN | 03/05/2026 | CANCELLED BY APPLICANT | JSTEWART |
| GRAVITY SEWER TEST | 03/05/2026 | CANCELLED BY APPLICANT | JSTEWART |
| MONOLITHIC SLAB | 03/03/2026 | APPROVED | JSTEWART |
| Note: 3/2/2026 - PREVIOUS INSPECTION NOTES 2 water supply lines and a DWV plumbing running thru a interior footing will need to be sleeved. FBCR P2603.4 | |||
| MONOLITHIC SLAB | 03/02/2026 | Disapproved - NO FEE | JSTEWART |
| Note: 2 water supply lines and a DWV plumbing running thru a interior footing will need to be sleeved. FBCR P2603.4 | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 02/24/2026 | APPROVED | JSTEWART |
| WATER METER INSTALLATION REQUEST | 02/24/2026 | APPROVED | ISANDERSON |
| FORMBOARD SURVEY (OFFICE USE ONLY) | 02/23/2026 | APPROVED | PFLANAGAN |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 04/04/2026 | 04/06/2026 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 02/23/2026 | 02/23/2026 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 02/23/2026 | 02/23/2026 |
| Note: Released By: KATIE TAING - (386)986-3751 - KTAING@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 02/04/2026 | 02/05/2026 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 01/29/2026 | 02/04/2026 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 01/29/2026 | 02/04/2026 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 01/29/2026 | 02/03/2026 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 01/29/2026 | 01/30/2026 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| GAS | COMPLETE | 01/29/2026 | 01/30/2026 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 01/29/2026 | 02/02/2026 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 01/29/2026 | 01/30/2026 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 01/29/2026 | 02/02/2026 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ZON | HOLD | 01/29/2026 | 02/03/2026 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM there is another permit in ready status for this address. Permit # 2025080096 pleae cancel the one that needs to be. | |||
| URB | COMPLETE | 01/29/2026 | 02/02/2026 |
| Note: Released By: JOHN BEAUDET - (386)986-2456 - JBEAUDET@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 05/18/2026 |
| FC IMPACT FEE EMS | ¤62.00 | 02/11/2026 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 02/11/2026 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 02/11/2026 |
| FIRE RES IMPACT FEE 10-25 | ¤942.00 | 02/11/2026 |
| WATER METER W/OUT TAP | ¤965.03 | 02/11/2026 |
| PARKS IMPACT FEE 10-25 | ¤3,164.00 | 02/11/2026 |
| RECLAIM WATER PERMIT INSPECTIO | ¤40.00 | 02/11/2026 |
| RSI DRIVEWAY AFTER POUR | ¤16.25 | 02/11/2026 |
| RSE DRIVE PRE POUR INSPECTION | ¤32.50 | 02/11/2026 |
| RSI FIELD SURVEY INSPECTION | ¤48.75 | 02/11/2026 |
| RSI FORMBOARD REVIEW | ¤16.25 | 02/11/2026 |
| RSI PLAN REVIEW NEW | ¤48.75 | 02/11/2026 |
| RSI FNL SURVEY/GRADING CERT | ¤48.75 | 02/11/2026 |
| RSI ROW FINAL INSPECTION | ¤16.25 | 02/11/2026 |
| SCHOOL BOARD IMPACT FEE RES | ¤5,450.00 | 02/11/2026 |
| SURCHARGE FS 533.721 | ¤11.74 | 02/11/2026 |
| SURCHARGE - FS 468.631 | ¤17.61 | 02/11/2026 |
| TRANSP RES IMPACT FEE 10-25 | ¤6,175.26 | 02/11/2026 |
| WASTEWATER PERM INSPECTION | ¤80.00 | 02/11/2026 |
| WASTEWATER PERM REVIEW | ¤25.00 | 02/11/2026 |
| SEWER CAPITAL FACILITY | ¤3,628.86 | 02/11/2026 |
| WATER CAPITAL FACILITY FEE | ¤3,091.14 | 02/11/2026 |
| WATER PERMIT REVIEW | ¤25.00 | 02/11/2026 |
| SITE PLAN 30 | ¤30.00 | 02/11/2026 |
| WATER-METER | ¤874.47 | 02/11/2026 |
| WATER- TURN ON | ¤50.00 | 02/11/2026 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 02/11/2026 |
| INSPECTION - RESIDENTIAL | ¤891.00 | 02/11/2026 |
| PLAN REVIEW - RESIDENTIAL | ¤252.72 | 02/11/2026 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤26,559.33 |