I want to search for...
Permit #2026010994
Permit Details
Status: COED
| Parcel Id: 07-11-31-7024-00430-0110 |
| Block: 00430 |
| Subdivision: 7024 - |
| Job Phone: 407-476-6212 |
| Location Address: 81 PRITCHARD DR |
| Type: SLRE - SOLAR ELECTRIC - PHOTOVOLTAIC |
| Issue Date: 01/30/2026 |
| NOC: RECORDED |
| Applicant name: FREDERICK C BRAUN |
| Owner: STICHTER GARY GENE & SHIRLEY STICHTER TRUSTEES |
|
Address 81 PRITCHARD DRIVE PALM COAST, FL 32164 |
| Lot: 0110 |
| Contracted Stated Job Value: ¤26,953.40 |
| Job Description: PV solar panel installation roof mounted |
| Type: CN |
Contractor
PJWD ENERGY LLC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
6752 CURTIS STREET ORLANDO, FL 32807 |
EC13012687 (Exp: 08/31/2026) | 407-476-6212 |
Inspection History
| Type | Request Date | Result | Inspector |
| SOLAR ELECTRIC FINAL | 03/24/2026 | FINAL APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 3/24/2026 11:33:42 AM *** Final Approved 3/4/2026 - PREVIOUS INSPECTION NOTES 3/4/26: Previously listed item 1 remains unresolved. 2/17/2026 - PREVIOUS INSPECTION NOTES 2/17/26: 1). wires laying directly on roof under panels need to be lifted off of shingles and secured in place. NEC-690.31 2). Disconnect needs service entrance barrier over energized conductors. NEC 240.40/690.13(A) 3). Breaker in Main breaker panel needs to be identified as to what it controls. NEC 408.4 (A) | |||
| SOLAR ELECTRIC FINAL | 03/04/2026 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 3/4/2026 2:33:13 PM *** 3/4/26: Previously listed item 1 remains unresolved. 2/17/2026 - PREVIOUS INSPECTION NOTES 2/17/26: 1). wires laying directly on roof under panels need to be lifted off of shingles and secured in place. NEC-690.31 2). Disconnect needs service entrance barrier over energized conductors. NEC 240.40/690.13(A) 3). Breaker in Main breaker panel needs to be identified as to what it controls. NEC 408.4 (A) | |||
| SOLAR ELECTRIC FINAL | 02/17/2026 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 2/17/2026 2:19:10 PM *** 2/17/26: 1). wires laying directly on roof under panels need to be lifted off of shingles and secured in place. NEC-690.31 2). Disconnect needs service entrance barrier over energized conductors. NEC 240.40/690.13(A) 3). Breaker in Main breaker panel needs to be identified as to what it controls. NEC 408.4 (A) |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 01/29/2026 | 01/30/2026 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 01/29/2026 | 01/30/2026 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 03/23/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 03/02/2026 |
| SURCHARGE FS 533.721 | ¤2.00 | 01/30/2026 |
| SURCHARGE - FS 468.631 | ¤2.54 | 01/30/2026 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 01/30/2026 |
| INSPECTION - RESIDENTIAL | ¤74.25 | 01/30/2026 |
| SOLAR PLAN REVIEW | ¤65.00 | 01/30/2026 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤253.79 |