I want to search for...

Permit #2026010994

Permit Details

Status: COED

Parcel Id: 07-11-31-7024-00430-0110
Block: 00430
Subdivision: 7024 -
Job Phone: 407-476-6212
Location Address: 81 PRITCHARD DR
Type: SLRE - SOLAR ELECTRIC - PHOTOVOLTAIC
Issue Date: 01/30/2026
NOC: RECORDED
Applicant name: FREDERICK C BRAUN
Owner: STICHTER GARY GENE & SHIRLEY STICHTER TRUSTEES

Address

81 PRITCHARD DRIVE

PALM COAST, FL 32164

Lot: 0110
Contracted Stated Job Value: ¤26,953.40
Job Description: PV solar panel installation roof mounted
Type: CN

Contractor

PJWD ENERGY LLC
Status Location Address State License Number Phone
ACTIVE

6752 CURTIS STREET

ORLANDO, FL 32807

EC13012687 (Exp: 08/31/2026) 407-476-6212

Inspection History

Type Request Date Result Inspector
SOLAR ELECTRIC FINAL 03/24/2026 FINAL APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 3/24/2026 11:33:42 AM *** Final Approved 3/4/2026 - PREVIOUS INSPECTION NOTES 3/4/26: Previously listed item 1 remains unresolved. 2/17/2026 - PREVIOUS INSPECTION NOTES 2/17/26: 1). wires laying directly on roof under panels need to be lifted off of shingles and secured in place. NEC-690.31 2). Disconnect needs service entrance barrier over energized conductors. NEC 240.40/690.13(A) 3). Breaker in Main breaker panel needs to be identified as to what it controls. NEC 408.4 (A)
SOLAR ELECTRIC FINAL 03/04/2026 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 3/4/2026 2:33:13 PM *** 3/4/26: Previously listed item 1 remains unresolved. 2/17/2026 - PREVIOUS INSPECTION NOTES 2/17/26: 1). wires laying directly on roof under panels need to be lifted off of shingles and secured in place. NEC-690.31 2). Disconnect needs service entrance barrier over energized conductors. NEC 240.40/690.13(A) 3). Breaker in Main breaker panel needs to be identified as to what it controls. NEC 408.4 (A)
SOLAR ELECTRIC FINAL 02/17/2026 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 2/17/2026 2:19:10 PM *** 2/17/26: 1). wires laying directly on roof under panels need to be lifted off of shingles and secured in place. NEC-690.31 2). Disconnect needs service entrance barrier over energized conductors. NEC 240.40/690.13(A) 3). Breaker in Main breaker panel needs to be identified as to what it controls. NEC 408.4 (A)

Review History

Department Status Date In Date Out
BLD COMPLETE 01/29/2026 01/30/2026
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
ELEC COMPLETE 01/29/2026 01/30/2026
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 03/23/2026
REINSPECTION RESIDENTIAL ¤40.00 03/02/2026
SURCHARGE FS 533.721 ¤2.00 01/30/2026
SURCHARGE - FS 468.631 ¤2.54 01/30/2026
ADMINISTRATIVE RESIDENTIAL ¤30.00 01/30/2026
INSPECTION - RESIDENTIAL ¤74.25 01/30/2026
SOLAR PLAN REVIEW ¤65.00 01/30/2026
Fees Total Due: ¤0.00 Total Paid: ¤253.79