I want to search for...
Permit #2026011032
Permit Details
Status: FINAL
| Parcel Id: 23-11-30-6061-00000-1290 |
| Subdivision: 2332 - WHITEVIEW VILLAGE SUBDIVISION PHASE 2 |
| Job Phone: 386-931-9006 |
| Location Address: 117 WAVERLY LN |
| Type: DR - DRIVEWAY |
| Issue Date: 03/05/2026 |
| NOC: Unknown |
| Applicant name: JOSE CARLOS AZEVEDO |
| Owner: KIRKPATRICK, JEANINE & DONALD |
|
Address 117 WAVERLY LN PALM COAST, FL 32164 |
| Lot: 129 |
| Contracted Stated Job Value: ¤2,100.00 |
| Job Description: Paver Driveway Extension |
| Type: CN |
Contractor
S & D CONSTRUCTION AND MAINTENANCE
| Status | Location Address | Phone |
| ACTIVE |
37 PRICE LANE PALM COAST, FL 32164 |
386-931-9006 |
Inspection History
| Type | Request Date | Result | Inspector |
| ROW - FINAL APRON (AFTER POUR) | 03/19/2026 | APPROVED | TPOLACEK |
| Note: PAVERS ARE SET AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW - FINAL INSPECTION | 03/19/2026 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| U -UTILITY RESIDENTIAL FINAL | 03/19/2026 | FINAL APPROVED | BWRIGHT |
| ROW- PRE-APRON (PRE-POUR) | 03/13/2026 | APPROVED | TPOLACEK |
| Note: APPROVED TO LAY PAVERS AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED Inspector Notes from Inspection 9271 3/7/26 AT THE TIME OF THIS INSPECTION YOU ARE APPROVED TO POUR YOUR DRIVEWAY AND APRON PAVER RESTRAINTS. **** DO NOT LAY ANY PAVERS UNTIL AFTER A SECONDARY SPREAD AND COMPACTION INSPECTION HAS BEEN SCHEDULED AND PASSED**** BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS 3/6/2026 - PREVIOUS INSPECTION NOTES 03-06-26 TPOLACEK**** AREA FROM EDGE OF CURB TO SIDE WALK MUST BE A MINIMUM OF 8" 5" OF CONCRETE, PAVER BASE AND 2 3/8 PAVERS, FOOTERS/ PAVER RESTRAINTS MUST BE A MINIMUM OF 8" DEEP BY 4" WIDE FOR 5" OF CONCRETE THIN SET AND PAVERS. AT THIS TIME THEY DO NOT MEET COPC MINIMUM REQUIRMENTS. ANY QUESTIONS PLEASE CALL TOM 386-346-8986 I WILL CANCEL THIS INSPECTION DUE TO INSPECTOR WOULD NORMALLY SCHEDULE THIS WHEN APPROVING PRE POUR | |||
| ROW- PRE-APRON (PRE-POUR) | 03/09/2026 | PARTIALLY APPROVED | FSLADISH |
| Note: 3/7/26 AT THE TIME OF THIS INSPECTION YOU ARE PARTIALLY APPROVED TO POUR YOUR DRIVEWAY APRON, SIDEWALK AND PAVER RESTRAINTS. **** DO NOT LAY ANY PAVERS UNTIL AFTER A SECONDARY SPREAD AND COMPACTION INSPECTION HAS BEEN SCHEDULED AND PASSED**** BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS 3/6/2026 - PREVIOUS INSPECTION NOTES 03-06-26 TPOLACEK**** AREA FROM EDGE OF CURB TO SIDE WALK MUST BE A MINIMUM OF 8" 5" OF CONCRETE, PAVER BASE AND 2 3/8 PAVERS, FOOTERS/ PAVER RESTRAINTS MUST BE A MINIMUM OF 8" DEEP BY 4" WIDE FOR 5" OF CONCRETE THIN SET AND PAVERS. AT THIS TIME THEY DO NOT MEET COPC MINIMUM REQUIRMENTS. ANY QUESTIONS PLEASE CALL TOM 386-346-8986 | |||
| ROW- PAVER RESTRAINTS | 03/09/2026 | APPROVED - AS NOTED | FSLADISH |
| Note: 3/7/26 AT THE TIME OF THIS INSPECTION YOU ARE APPROVED TO POUR YOUR DRIVEWAY AND APRON PAVER RESTRAINTS. **** DO NOT LAY ANY PAVERS UNTIL AFTER A SECONDARY SPREAD AND COMPACTION INSPECTION HAS BEEN SCHEDULED AND PASSED**** BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS 3/6/2026 - PREVIOUS INSPECTION NOTES 03-06-26 TPOLACEK**** AREA FROM EDGE OF CURB TO SIDE WALK MUST BE A MINIMUM OF 8" 5" OF CONCRETE, PAVER BASE AND 2 3/8 PAVERS, FOOTERS/ PAVER RESTRAINTS MUST BE A MINIMUM OF 8" DEEP BY 4" WIDE FOR 5" OF CONCRETE THIN SET AND PAVERS. AT THIS TIME THEY DO NOT MEET COPC MINIMUM REQUIRMENTS. ANY QUESTIONS PLEASE CALL TOM 386-346-8986 I WILL CANCEL THIS INSPECTION DUE TO INSPECTOR WOULD NORMALLY SCHEDULE THIS WHEN APPROVING PRE POUR | |||
| ROW- PRE-APRON (PRE-POUR) | 03/06/2026 | Disapproved - NO FEE | TPOLACEK |
| Note: 03-06-26 TPOLACEK**** AREA FROM EDGE OF CURB TO SIDE WALK MUST BE A MINIMUM OF 8" 5" OF CONCRETE, PAVER BASE AND 2 3/8 PAVERS, FOOTERS/ PAVER RESTRAINTS MUST BE A MINIMUM OF 8" DEEP BY 4" WIDE FOR 5" OF CONCRETE THIN SET AND PAVERS. AT THIS TIME THEY DO NOT MEET COPC MINIMUM REQUIRMENTS. ANY QUESTIONS PLEASE CALL TOM 386-346-8986 | |||
| ROW- PAVER RESTRAINTS | 03/06/2026 | CANCELLED BY APPLICANT | TPOLACEK |
| Note: 03-06-26 TPOLACEK**** AREA FROM EDGE OF CURB TO SIDE WALK MUST BE A MINIMUM OF 8" 5" OF CONCRETE, PAVER BASE AND 2 3/8 PAVERS, FOOTERS/ PAVER RESTRAINTS MUST BE A MINIMUM OF 8" DEEP BY 4" WIDE FOR 5" OF CONCRETE THIN SET AND PAVERS. AT THIS TIME THEY DO NOT MEET COPC MINIMUM REQUIRMENTS. ANY QUESTIONS PLEASE CALL TOM 386-346-8986 I WILL CANCEL THIS INSPECTION DUE TO INSPECTOR WOULD NORMALLY SCHEDULE THIS WHEN APPROVING PRE POUR |
Review History
| Department | Status | Date In | Date Out |
| ZON | COMPLETE | 02/11/2026 | 02/12/2026 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM NO ROW AGREEMENT REQUIRED IN WHITEVIEW VILLAGE. | |||
| ENGIN1 | COMPLETE | 01/30/2026 | 02/02/2026 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| RSI | COMPLETE | 01/30/2026 | 02/05/2026 |
| Note: Released By: FRANK SLADISH - (386)871-6113 - FSLADISH@PALMCOASTGOV.COM | |||
| UTL | COMPLETE | 01/30/2026 | 02/06/2026 |
| Note: Released By: LARRY FITZGERALD - (386)286-2041 - LFITZGERALD@PALMCOASTGOV.COM | |||
| ZON | HOLD | 01/30/2026 | 01/30/2026 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM the right of way agreement paper work needs to be for a trust as the home is in a trust please use the correct agreements. emailing new trust forms please use the new forms not the old ones. Please have the owners on the deed sign and notarize a Right of way agreement exactly as the deed reads. Please use the new form I emailed to you directly as it was recently updated. There are three pages to this document. Once completed please submit through the portal first for review, once approved I will request the originals be brought to our office for processing. | |||
| URB | COMPLETE | 01/30/2026 | 02/06/2026 |
| Note: Released By: JOHN BEAUDET - (386)986-2456 - JBEAUDET@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 03/05/2026 |
| RSI DRIVEWAY AFTER POUR | ¤16.25 | 03/05/2026 |
| RSE DRIVE PRE POUR INSPECTION | ¤32.50 | 03/05/2026 |
| RSI ROW FINAL INSPECTION | ¤16.25 | 03/05/2026 |
| RSI SITE PLAN REVIEW | ¤16.25 | 03/05/2026 |
| SITE PLAN 15 | ¤15.00 | 03/05/2026 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤126.25 |