I want to search for...

Permit #2026020032

Permit Details

Status: INSPECT

Parcel Id: 07-11-31-7030-00240-0040
CONDITIONED SPACE: 2902 sqft
GARAGE: 894 sqft
SCREEN PORCH (SOLID ROOF) : 320 sqft
Total Square Footage: 4116 sqft
Block: 00240
Subdivision: 2154 - SECTION 30-ROYAL PALMS
Job Phone: 530-308-7323
Location Address: 121 RAE DR
Type: DU - DUPLEX
Issue Date: 02/23/2026
NOC: RECORDED
Applicant name: DONALD CABRAL
Owner: ENDURANCE PROPERTY HOLDING LLC

Address

PO BOX 121

EAST SCHODACK, NY 12063

Lot: 0040
Contracted Stated Job Value: ¤500,000.00
Job Description: DUPLEX
Type: CN

Contractor

DC CONSTRUCTION PALM COAST LLC
Status Location Address State License Number
ACTIVE

109 UNIVERSAL TRAIL

,

CGC1531039 (Exp: 08/31/2026)

Sub Contractors

DANIEL JOSEPH SCHWARZKOPF
Status Location Address State License Number Phone
ACTIVE

4601 E MOODY BLVD D6

PALM COAST, FL 32164

EC13010351 (Exp: 08/31/2026) 386-313-6211
ROBERT EDWIN BERRONG
Status Location Address State License Number Phone
ACTIVE

800 BELLE TERRE PKWY STE 200-114

FLAGLER BEACH, FL 32136

CCC1336183 (Exp: 08/31/2026) 386-266-9879
DENNIS BRAXTON BRAGG
Status Location Address State License Number Phone
ACTIVE

363 FIR STREET

ORMOND BEACH, FL 32174

CFC1433357 (Exp: 08/31/2026) 386-882-7971
MICHAEL FRANK MORELLO
Status Location Address State License Number Phone Fax
ACTIVE

2 HARGROVE GRADE

PALM COAST, FL 32164

CAC1819466 (Exp: 08/31/2026) 386-445-5023 386-446-4614

Inspection History

Type Request Date Result Inspector
INSULATION 06/08/2026 CANCELLED BY APPLICANT CVANSTRAHLEN
ALL ROUGH 06/04/2026 APPROVED CVANSTRAHLEN
Note: 6/2/2026 - PREVIOUS INSPECTION NOTES Please fix items before next inspection #1-FBC [A]107.4-DUCT LAYOUT DOES NOT MATCH ENERGY CALCS ( Unit Left and Right E-cals do not match flex size do not match , missing register ( please resummit E-cals for revision and approval #2-FBCR P2605.1-PIPE SUPPORT CPVC UP TO 1" - 3 FEET HORIZONTAL, 10 FEET VERTICAL CPVC 1 1/4" AND UP - 4 FEET HORIZONTAL, 10 FEET VERTICAL PVC 4 FOOT HORIZONTAL, 10 FEET VERTICAL ( unit Lft side and Right side ) #3-All bathroom exhaust fans require two points of connection and Master bathroom exhausts need to be sealed properly at roof deck. Also, Master bathroom exhaust are not sealed/connected onto fan sleeve (correctly) as required. FBC-M1502.4.2 / FBC-M1601.4.1.).
FIREWALL FRAMING 06/04/2026 APPROVED CVANSTRAHLEN
LATH/BRICK/ WATER BARRIER 06/02/2026 APPROVED CVANSTRAHLEN
Note: 5/26/2026 - PREVIOUS INSPECTION NOTES Item # 4 and #3 still pending FBCR 609.1-GAP AT WINDOW/DOOR REVEAL TOO LARGE > 1/4 " PER MANUFACTURERS SPECS Inspector Notes from Inspection 2467 Items from previous inspection need to be fix #4-Truss A10 need repair ,( Left side closet wall ) #3- truss A05 need several repair and blocking ( right side )Please cleand up truss ) Inspector Notes from Inspection 2460 Please fix items before next inspection #1-Missing engineering on trusses A01 & A04( right and left side ) #2-truss A06 need repair (right side ) #3- truss A05 need several repair and blocking ( right side ) #4-Truss A10 need repair ,( Left side closet wall ) Inspector Notes from Inspection 2340 Please fix items before next inspection #1-FBC 3303.5-SWALE CLEAR #2-FBCR 606.3.4-COVERAGE OF REBAR (5/8 " HORIZONTAL) (3/4" MIN. OTHER) (2" EXPOSED TO WEATHER OR SOIL
ALL ROUGH 06/02/2026 Disapproved -FEE REQUIRED CVANSTRAHLEN
Note: *** NOTES ADDED BY CVANSTRAHLEN 6/2/2026 11:04:42 AM *** #4- Please fix duct work , some areas on return and supply have been damage Please fix items before next inspection #1-FBC [A]107.4-DUCT LAYOUT DOES NOT MATCH ENERGY CALCS ( Unit Left and Right E-cals do not match flex size do not match , missing register ( please resummit E-cals for revision and approval #2-FBCR P2605.1-PIPE SUPPORT CPVC UP TO 1" - 3 FEET HORIZONTAL, 10 FEET VERTICAL CPVC 1 1/4" AND UP - 4 FEET HORIZONTAL, 10 FEET VERTICAL PVC 4 FOOT HORIZONTAL, 10 FEET VERTICAL ( unit Lft side and Right side ) #3-All bathroom exhaust fans require two points of connection and Master bathroom exhausts need to be sealed properly at roof deck. Also, Master bathroom exhaust are not sealed/connected onto fan sleeve (correctly) as required. FBC-M1502.4.2 / FBC-M1601.4.1.).
LATH/BRICK/ WATER BARRIER 05/26/2026 PARTIALLY APPROVED CVANSTRAHLEN
Note: Item # 4 and #3 still pending FBCR 609.1-GAP AT WINDOW/DOOR REVEAL TOO LARGE > 1/4 " PER MANUFACTURERS SPECS Inspector Notes from Inspection 2467 Items from previous inspection need to be fix #4-Truss A10 need repair ,( Left side closet wall ) #3- truss A05 need several repair and blocking ( right side )Please cleand up truss ) Inspector Notes from Inspection 2460 Please fix items before next inspection #1-Missing engineering on trusses A01 & A04( right and left side ) #2-truss A06 need repair (right side ) #3- truss A05 need several repair and blocking ( right side ) #4-Truss A10 need repair ,( Left side closet wall ) Inspector Notes from Inspection 2340 Please fix items before next inspection #1-FBC 3303.5-SWALE CLEAR #2-FBCR 606.3.4-COVERAGE OF REBAR (5/8 " HORIZONTAL) (3/4" MIN. OTHER) (2" EXPOSED TO WEATHER OR SOIL
ROOF VALLEY & METAL 05/07/2026 APPROVED - AS NOTED CVANSTRAHLEN
Note: Items from previous inspection need to be fix #4-Truss A10 need repair ,( Left side closet wall ) #3- truss A05 need several repair and blocking ( right side )Please cleand up truss ) Inspector Notes from Inspection 2460 Please fix items before next inspection #1-Missing engineering on trusses A01 & A04( right and left side ) #2-truss A06 need repair (right side ) #3- truss A05 need several repair and blocking ( right side ) #4-Truss A10 need repair ,( Left side closet wall ) Inspector Notes from Inspection 2340 Please fix items before next inspection #1-FBC 3303.5-SWALE CLEAR #2-FBCR 606.3.4-COVERAGE OF REBAR (5/8 " HORIZONTAL) (3/4" MIN. OTHER) (2" EXPOSED TO WEATHER OR SOIL
WALL SHEATHING 05/05/2026 APPROVED - AS NOTED CVANSTRAHLEN
Note: Please fix items before next inspection #1-Missing engineering on trusses A01 & A04( right and left side ) #2-truss A06 need repair (right side ) #3- truss A05 need several repair and blocking ( right side ) #4-Truss A10 need repair ,( Left side closet wall ) Inspector Notes from Inspection 2340 Please fix items before next inspection #1-FBC 3303.5-SWALE CLEAR #2-FBCR 606.3.4-COVERAGE OF REBAR (5/8 " HORIZONTAL) (3/4" MIN. OTHER) (2" EXPOSED TO WEATHER OR SOIL
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/05/2026 APPROVED - AS NOTED CVANSTRAHLEN
Note: Please fix items before next inspection #1-Missing engineering on trusses A01 & A04( right and left side ) #2-truss A06 need repair (right side ) #3- truss A05 need several repair and blocking ( right side ) #4-Truss A10 need repair ,( Left side closet wall ) Inspector Notes from Inspection 2340 Please fix items before next inspection #1-FBC 3303.5-SWALE CLEAR #2-FBCR 606.3.4-COVERAGE OF REBAR (5/8 " HORIZONTAL) (3/4" MIN. OTHER) (2" EXPOSED TO WEATHER OR SOIL
ELECTRIC - EARLY POWER 04/22/2026 CANCELLED BY APPLICANT KSANDOE
ELECTRIC-TUG 04/22/2026 APPROVED - AS NOTED KSANDOE
TIE BEAM / LINTEL 04/01/2026 APPROVED - AS NOTED CVANSTRAHLEN
Note: Please fix items before next inspection #1-FBC 3303.5-SWALE CLEAR #2-FBCR 606.3.4-COVERAGE OF REBAR (5/8 " HORIZONTAL) (3/4" MIN. OTHER) (2" EXPOSED TO WEATHER OR SOIL
MONOLITHIC SLAB 03/19/2026 APPROVED HCAMACHO
Note: 3/18/2026 - PREVIOUS INSPECTION NOTES On both sides......Please cut and remove vapor barrier (Plastic) from the bottom of the footing at the Ufer rebar for the required length of 20ft for Concrete- encased electrode...base of footing required to be in direct contact with Earth. NEC 250.52(A)(3)
MONOLITHIC SLAB 03/18/2026 Disapproved - NO FEE JSTEWART
Note: On both sides......Please cut and remove vapor barrier (Plastic) from the bottom of the footing at the Ufer rebar for the required length of 20ft for Concrete- encased electrode...base of footing required to be in direct contact with Earth. NEC 250.52(A)(3)
PLUMBING 1ST ROUGH UNDERGROUND 03/16/2026 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 3/16/2026 4:06:30 PM *** Approved
FORMBOARD SURVEY (OFFICE USE ONLY) 03/10/2026 APPROVED RRICKS
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 03/02/2026 APPROVED PKNAPIK
WATER METER INSTALLATION REQUEST 02/24/2026 APPROVED ISANDERSON
PEP TANK INSTALLATION REQUEST
U-CROSS CONNECTION
ROW- PRE-APRON (PRE-POUR)
ROW - FINAL APRON (AFTER POUR)
ROW - FINAL INSPECTION
U -UTILITY RESIDENTIAL FINAL
INSULATION
Note: 6/8/2026 - PREVIOUS INSPECTION NOTES
DRYWALL NAILING
BLD - BUILDING FINAL
GRAVITY SEWER TEST
SEWER TIE IN
ELECTRIC - EARLY POWER
Note: 4/22/2026 - PREVIOUS INSPECTION NOTES
FIREWALL DRYWALL NAILING
FIREWALL FINAL

Review History

Department Status Date In Date Out
MECH COMPLETE 06/02/2026 06/03/2026
Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM
SW1 COMPLETE 03/10/2026 03/10/2026
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 03/10/2026 03/10/2026
Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM
BLD COMPLETE 03/02/2026 03/02/2026
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
BLD COMPLETE 02/20/2026 02/20/2026
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
BLD HOLD 02/16/2026 02/20/2026
Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM Truss packet has incorrect address
SWALE COMPLETE 02/03/2026 02/09/2026
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
ZON COMPLETE 02/02/2026 02/02/2026
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
CUSVC COMPLETE 02/02/2026 02/06/2026
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 02/02/2026 02/05/2026
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 02/02/2026 02/03/2026
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
GAS CANCEL 02/02/2026 02/03/2026
LOCATE COMPLETE 02/02/2026 02/05/2026
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH COMPLETE 02/02/2026 02/04/2026
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 02/02/2026 02/03/2026
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
BLD HOLD 02/02/2026 02/05/2026
Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM 1. Truss plan packet cover sheet or first page needs include the design professional of record (building design engineer or architect) approval stamp indicating acceptance and approval of truss design (Not wet seal)

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 06/02/2026
FC IMPACT FEE EMS ¤124.00 02/23/2026
FC IMPACT FEE LAW ENFORCEMENT ¤436.00 02/23/2026
FC IMPACT FEE LIBRARY ¤536.00 02/23/2026
FIRE RES IMPACT FEE 10-25 ¤1,884.00 02/23/2026
PEP TANK INSTALL ¤1,513.48 02/23/2026
PARKS IMPACT FEE 10-25 ¤6,328.00 02/23/2026
RSI DRIVEWAY AFTER POUR ¤16.25 02/23/2026
RSE DRIVE PRE POUR INSPECTION ¤32.50 02/23/2026
RSI FIELD SURVEY INSPECTION ¤48.75 02/23/2026
RSI FORMBOARD REVIEW ¤16.25 02/23/2026
RSI PLAN REVIEW NEW ¤48.75 02/23/2026
RSI FNL SURVEY/GRADING CERT ¤48.75 02/23/2026
RSI ROW FINAL INSPECTION ¤16.25 02/23/2026
SCHOOL BOARD IMPACT FEE RES ¤10,900.00 02/23/2026
WASTEWATER MAIN EXTENSION IMPA ¤4,770.00 02/23/2026
SURCHARGE FS 533.721 ¤20.81 02/23/2026
SURCHARGE - FS 468.631 ¤31.22 02/23/2026
SW ENG RES REVIEW 240 ¤240.00 02/23/2026
WATER METER W/ TAP ¤4,653.86 02/23/2026
TRANS DUPLEX 10-25 ¤11,097.25 02/23/2026
SEWER CREDIT (¤1,466.00) 02/23/2026
WASTEWATER PERM INSPECTION ¤80.00 02/23/2026
WASTEWATER PERM REVIEW ¤100.00 02/23/2026
SEWER CAPITAL FACILITY ¤8,830.00 02/23/2026
WATER CAPITAL FACILITY FEE ¤7,580.98 02/23/2026
WATER PERMIT INSPECTION ¤80.00 02/23/2026
WATER MAIN EXTENSION IMPACT ¤1,834.54 02/23/2026
SITE PLAN 30 ¤30.00 02/23/2026
WATER-METER ¤965.03 02/23/2026
WATER- TURN ON ¤50.00 02/23/2026
WATER- TURN ON ¤100.00 02/23/2026
ADMINISTRATIVE RESIDENTIAL ¤30.00 02/23/2026
INSPECTION - RESIDENTIAL ¤1,597.75 02/23/2026
PLAN REVIEW - RESIDENTIAL ¤453.18 02/23/2026
Fees Total Due: ¤0.00 Total Paid: ¤63,067.60