I want to search for...
Permit #2026020171
Permit Details
Status: INSPECT
| Parcel Id: 20-12-31-5562-00000-1760 |
| CONDITIONED SPACE: 1775 sqft |
| GARAGE: 499 sqft |
| OPENED PORCH (WITH ROOF) : 270 sqft |
| Total Square Footage: 2544 sqft |
| Subdivision: 2362 - SEMINOLE PALMS SUBDIVISION PHASE 2 |
| Job Phone: 904-422-5276 |
| Location Address: 306 FISHTAIL PL |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 03/09/2026 |
| NOC: RECORDED |
| Applicant name: MATTHEW JAMES HENSON |
| Owner: PULTE HOME COMPANY, LLC |
|
Address 12724 GRAN BAY PARKWAY WEST JACKSONVILLE, FL 32258 |
|
Address STE 200 JACKSONVILLE, FL 32258 |
| Lot: 176 |
| Contracted Stated Job Value: ¤160,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
PULTE HOME COMPANY LLC
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
12724 GRAN BAY DRIVE PKWAY W , |
SUITE 140 JACKSONVILLE, FL 32258 |
CGC1514865 (Exp: 08/31/2026) | 904-422-5276 |
Sub Contractors
PHILLIP F GABY
| Status | Location Address | State License Number | Phone |
| ACTIVE |
PO BOX 56726 JACKSONVILLE, FL 32256 |
CCC1330190 (Exp: 08/31/2026) | 904-424-4665 |
BRETT CHRISTIAN GIBSON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
250 SEGOVIA RD ST AUGUSTINE, FL 32086 |
CAC1818423 (Exp: 08/31/2026) | 904-229-8131 |
PAUL ERIC FORSTER
| Status | Location Address | State License Number | Phone |
| ACTIVE |
6114 GOODMAN RD JACKSONVILLE, FL 32244 |
CFC1429261 (Exp: 08/31/2026) | 904-647-1820 |
JAMES E LINTON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
200 COLLEGE DR ORANGE PARK, FL 32065 |
EC0001152 (Exp: 08/31/2026) | 904-272-0272 |
Inspection History
| Type | Request Date | Result | Inspector |
| ROW- PRE-APRON (PRE-POUR) | 05/22/2026 | APPROVED | FSLADISH |
| Note: 5/22/26 AT THE TIME OF THE INSPECTION PREPOUR AREA IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD REMOVE ALL WATER AND CHECK COMPACTION BEFORE POURING CONCRETE. 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED IS REQUIRED. PLEASE REVIEW CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. NO EXPANSION JOINTS ALLOWED. | |||
| DRYWALL NAILING | 05/14/2026 | APPROVED | RSIMS |
| INSULATION | 05/12/2026 | APPROVED | RSIMS |
| Note: 5/7/2026 - PREVIOUS INSPECTION NOTES 5/7/26: Previously listed deficiency remains unresolved. 5/6/2026 - PREVIOUS INSPECTION NOTES FBC EC-Residential 402.4.1.1 Batts must extend over the top plate to ensure continuity of R value FRC 806.3 1' air gap required Inspector Notes from Inspection 2420 5/1/26: Check at Insulation. Previously listed items 4 and 5 remain unresolved. 4). Kitchen exhaust is missing the 3 evenly spaced screws at joints/connections. FBC-M1601.4.1 5). metal outlet box for security panel must be installed and bonded for this inspection. NEC-250.148(C). > Box is installed but ground wire is not attached to the bonding screw as required. Please secure ground wire positively to bonding screw. 4/27/2026 - PREVIOUS INSPECTION NOTES 4/27/26: 4/27/26: 1). Missing plans in permit box / on site. All plans must remain on site and available for inspections. FBC [A]107.3.1 2). Electrical wires need to be drilled through a flat 2" x 4" above the breaker panel to provide required fireblocking per FBC-R302.11 3). Water heater and Condenser feed wires need to be phased at breaker panel. NEC 200.6(B) 4). Kitchen exhaust is missing the 3 evenly spaced screws at joints/connections. FBC-M1601.4.1 5). metal outlet box for security panel must be installed and bonded for this inspection. NEC-250.148(C). 6). Bathroom exhausts are missing the Strap (mechanical connection) as required. FBC-M1502.4.2 / FBC-M1601.4.1 / R806.1 7). Main water pipe is not connected to meter, exposed or pressurized as required. FBCR P2503.7 3/18/26: Main underground water service piping is installed from house to meter location but did not have a pressure test on it so it will need to be exposed again at All Rough. | |||
| GRAVITY SEWER TEST | 05/12/2026 | APPROVED | RSIMS |
| Note: New inspection due to canceled inspection 5/5/2026 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2060 *** NOTES ADDED BY RSIMS 3/18/2026 2:20:16 PM *** 3/18/26: Main underground water service piping is installed from house to meter location but did not have a pressure test on it so it will need to be exposed again at All Rough. | |||
| SEWER TIE IN | 05/12/2026 | APPROVED | RSIMS |
| Note: New inspection due to canceled inspection 5/5/2026 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2060 *** NOTES ADDED BY RSIMS 3/18/2026 2:20:16 PM *** 3/18/26: Main underground water service piping is installed from house to meter location but did not have a pressure test on it so it will need to be exposed again at All Rough. | |||
| ELECTRIC - EARLY POWER | 05/12/2026 | CANCELLED BY APPLICANT | RSIMS |
| Note: 5/12/26: Cancelled > Called in too early. | |||
| GRAVITY SEWER TEST | 05/11/2026 | CANCELLED BY APPLICANT | WEB |
| Note: 5/5/2026 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2060 *** NOTES ADDED BY RSIMS 3/18/2026 2:20:16 PM *** 3/18/26: Main underground water service piping is installed from house to meter location but did not have a pressure test on it so it will need to be exposed again at All Rough. | |||
| SEWER TIE IN | 05/11/2026 | CANCELLED BY APPLICANT | WEB |
| Note: 5/5/2026 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2060 *** NOTES ADDED BY RSIMS 3/18/2026 2:20:16 PM *** 3/18/26: Main underground water service piping is installed from house to meter location but did not have a pressure test on it so it will need to be exposed again at All Rough. | |||
| INSULATION | 05/07/2026 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 5/7/26: Previously listed deficiency remains unresolved. 5/6/2026 - PREVIOUS INSPECTION NOTES FBC EC-Residential 402.4.1.1 Batts must extend over the top plate to ensure continuity of R value FRC 806.3 1' air gap required Inspector Notes from Inspection 2420 5/1/26: Check at Insulation. Previously listed items 4 and 5 remain unresolved. 4). Kitchen exhaust is missing the 3 evenly spaced screws at joints/connections. FBC-M1601.4.1 5). metal outlet box for security panel must be installed and bonded for this inspection. NEC-250.148(C). > Box is installed but ground wire is not attached to the bonding screw as required. Please secure ground wire positively to bonding screw. 4/27/2026 - PREVIOUS INSPECTION NOTES 4/27/26: 4/27/26: 1). Missing plans in permit box / on site. All plans must remain on site and available for inspections. FBC [A]107.3.1 2). Electrical wires need to be drilled through a flat 2" x 4" above the breaker panel to provide required fireblocking per FBC-R302.11 3). Water heater and Condenser feed wires need to be phased at breaker panel. NEC 200.6(B) 4). Kitchen exhaust is missing the 3 evenly spaced screws at joints/connections. FBC-M1601.4.1 5). metal outlet box for security panel must be installed and bonded for this inspection. NEC-250.148(C). 6). Bathroom exhausts are missing the Strap (mechanical connection) as required. FBC-M1502.4.2 / FBC-M1601.4.1 / R806.1 7). Main water pipe is not connected to meter, exposed or pressurized as required. FBCR P2503.7 3/18/26: Main underground water service piping is installed from house to meter location but did not have a pressure test on it so it will need to be exposed again at All Rough. | |||
| INSULATION | 05/06/2026 | Disapproved - NO FEE | KSANDOE |
| Note: FBC EC-Residential 402.4.1.1 Batts must extend over the top plate to ensure continuity of R value FRC 806.3 1' air gap required Inspector Notes from Inspection 2420 5/1/26: Check at Insulation. Previously listed items 4 and 5 remain unresolved. 4). Kitchen exhaust is missing the 3 evenly spaced screws at joints/connections. FBC-M1601.4.1 5). metal outlet box for security panel must be installed and bonded for this inspection. NEC-250.148(C). > Box is installed but ground wire is not attached to the bonding screw as required. Please secure ground wire positively to bonding screw. 4/27/2026 - PREVIOUS INSPECTION NOTES 4/27/26: 4/27/26: 1). Missing plans in permit box / on site. All plans must remain on site and available for inspections. FBC [A]107.3.1 2). Electrical wires need to be drilled through a flat 2" x 4" above the breaker panel to provide required fireblocking per FBC-R302.11 3). Water heater and Condenser feed wires need to be phased at breaker panel. NEC 200.6(B) 4). Kitchen exhaust is missing the 3 evenly spaced screws at joints/connections. FBC-M1601.4.1 5). metal outlet box for security panel must be installed and bonded for this inspection. NEC-250.148(C). 6). Bathroom exhausts are missing the Strap (mechanical connection) as required. FBC-M1502.4.2 / FBC-M1601.4.1 / R806.1 7). Main water pipe is not connected to meter, exposed or pressurized as required. FBCR P2503.7 3/18/26: Main underground water service piping is installed from house to meter location but did not have a pressure test on it so it will need to be exposed again at All Rough. | |||
| GRAVITY SEWER TEST | 05/05/2026 | CANCELLED BY APPLICANT | KSANDOE |
| Note: Inspector Notes from Inspection 2060 *** NOTES ADDED BY RSIMS 3/18/2026 2:20:16 PM *** 3/18/26: Main underground water service piping is installed from house to meter location but did not have a pressure test on it so it will need to be exposed again at All Rough. | |||
| SEWER TIE IN | 05/05/2026 | CANCELLED BY APPLICANT | KSANDOE |
| Note: Inspector Notes from Inspection 2060 *** NOTES ADDED BY RSIMS 3/18/2026 2:20:16 PM *** 3/18/26: Main underground water service piping is installed from house to meter location but did not have a pressure test on it so it will need to be exposed again at All Rough. | |||
| ELECTRIC-TUG | 05/04/2026 | APPROVED | KSANDOE |
| Note: 4/21/2026 - PREVIOUS INSPECTION NOTES Stand pipe/pedestal must be schd 80 pvc | |||
| ALL ROUGH | 05/01/2026 | APPROVED - AS NOTED | RSIMS |
| Note: 5/1/26: Check at Insulation. Previously listed items 4 and 5 remain unresolved. 4). Kitchen exhaust is missing the 3 evenly spaced screws at joints/connections. FBC-M1601.4.1 5). metal outlet box for security panel must be installed and bonded for this inspection. NEC-250.148(C). > Box is installed but ground wire is not attached to the bonding screw as required. Please secure ground wire positively to bonding screw. 4/27/2026 - PREVIOUS INSPECTION NOTES 4/27/26: 4/27/26: 1). Missing plans in permit box / on site. All plans must remain on site and available for inspections. FBC [A]107.3.1 2). Electrical wires need to be drilled through a flat 2" x 4" above the breaker panel to provide required fireblocking per FBC-R302.11 3). Water heater and Condenser feed wires need to be phased at breaker panel. NEC 200.6(B) 4). Kitchen exhaust is missing the 3 evenly spaced screws at joints/connections. FBC-M1601.4.1 5). metal outlet box for security panel must be installed and bonded for this inspection. NEC-250.148(C). 6). Bathroom exhausts are missing the Strap (mechanical connection) as required. FBC-M1502.4.2 / FBC-M1601.4.1 / R806.1 7). Main water pipe is not connected to meter, exposed or pressurized as required. FBCR P2503.7 3/18/26: Main underground water service piping is installed from house to meter location but did not have a pressure test on it so it will need to be exposed again at All Rough. | |||
| ALL ROUGH | 04/27/2026 | Disapproved - NO FEE | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 4/27/2026 11:29:02 AM *** 4/27/26: 4/27/26: 1). Missing plans in permit box / on site. All plans must remain on site and available for inspections. FBC [A]107.3.1 2). Electrical wires need to be drilled through a flat 2" x 4" above the breaker panel to provide required fireblocking per FBC-R302.11 3). Water heater and Condenser feed wires need to be phased at breaker panel. NEC 200.6(B) 4). Kitchen exhaust is missing the 3 evenly spaced screws at joints/connections. FBC-M1601.4.1 5). metal outlet box for security panel must be installed and bonded for this inspection. NEC-250.148(C). 6). Bathroom exhausts are missing the Strap (mechanical connection) as required. FBC-M1502.4.2 / FBC-M1601.4.1 / R806.1 7). Main water pipe is not connected to meter, exposed or pressurized as required. FBCR P2503.7 3/18/26: Main underground water service piping is installed from house to meter location but did not have a pressure test on it so it will need to be exposed again at All Rough. | |||
| LATH/BRICK/ WATER BARRIER | 04/22/2026 | APPROVED | RSIMS |
| Note: Inspector Notes from Inspection 2467 Check zip tape on 5x5 at water barrier inspection 4/13/2026 - PREVIOUS INSPECTION NOTES 4/13/26: 1). 5" x 5" wall flashing must be sealed / taped to the zip wall plywood. FBC-R903.2 | |||
| ELECTRIC-TUG | 04/21/2026 | Disapproved - NO FEE | KSANDOE |
| Note: Stand pipe/pedestal must be schd 80 pvc | |||
| ROOF VALLEY & METAL | 04/14/2026 | APPROVED - AS NOTED | KSANDOE |
| Note: Check zip tape on 5x5 at water barrier inspection 4/13/2026 - PREVIOUS INSPECTION NOTES 4/13/26: 1). 5" x 5" wall flashing must be sealed / taped to the zip wall plywood. FBC-R903.2 | |||
| ROOF VALLEY & METAL | 04/13/2026 | Disapproved - NO FEE | RSIMS |
| Note: 4/13/26: 1). 5" x 5" wall flashing must be sealed / taped to the zip wall plywood. FBC-R903.2 | |||
| WALL SHEATHING | 04/02/2026 | APPROVED | RSIMS |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 04/02/2026 | APPROVED | RSIMS |
| WATER METER INSTALLATION REQUEST | 04/01/2026 | APPROVED | ISANDERSON |
| MONOLITHIC SLAB | 03/20/2026 | APPROVED | KSANDOE |
| PLUMBING 1ST ROUGH UNDERGROUND | 03/18/2026 | APPROVED - AS NOTED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 3/18/2026 2:20:16 PM *** 3/18/26: Main underground water service piping is installed from house to meter location but did not have a pressure test on it so it will need to be exposed again at All Rough. | |||
| FORMBOARD SURVEY (OFFICE USE ONLY) | 03/17/2026 | APPROVED | PFLANAGAN |
| ELECTRIC - EARLY POWER | |||
| Note: 5/12/2026 - PREVIOUS INSPECTION NOTES 5/12/26: Cancelled > Called in too early. | |||
| U-CROSS CONNECTION | |||
| BLD - BUILDING FINAL | |||
| ROW - FINAL APRON (AFTER POUR) | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | |||
| ROW - FINAL INSPECTION | |||
| U -UTILITY RESIDENTIAL FINAL |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 03/30/2026 | 04/01/2026 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 03/30/2026 | 03/30/2026 |
| Note: Released By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 03/17/2026 | 03/17/2026 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 03/17/2026 | 03/17/2026 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 02/27/2026 | 03/04/2026 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 02/27/2026 | 03/05/2026 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| BLD | HOLD | 02/04/2026 | 02/09/2026 |
| Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM Roofing Worksheet FL# 1932.1 not valid | |||
| CUSVC | COMPLETE | 02/04/2026 | 02/13/2026 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 02/04/2026 | 02/09/2026 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 02/04/2026 | 02/05/2026 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 02/04/2026 | 02/06/2026 |
| LOCATE | COMPLETE | 02/04/2026 | 02/06/2026 |
| Note: Released By: BRITTANY VITALE - - | |||
| MECH | COMPLETE | 02/04/2026 | 02/06/2026 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 02/04/2026 | 02/11/2026 |
| Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM - Please provide benchmark on the grading plan. - There is a slope greater than 4:1 on the left side at the front of the home going to the lot line. The greatest drop allowed over 5.7' is 1.425'. Please revise as needed. | |||
| ZON | COMPLETE | 02/04/2026 | 02/06/2026 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| URB | COMPLETE | 02/04/2026 | 02/05/2026 |
| Note: Released By: JOHN BEAUDET - (386)986-2456 - JBEAUDET@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 05/07/2026 |
| FC IMPACT FEE EMS | ¤62.00 | 03/09/2026 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 03/09/2026 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 03/09/2026 |
| FIRE RES IMPACT FEE 10-25 | ¤942.00 | 03/09/2026 |
| WATER METER W/OUT TAP | ¤965.03 | 03/09/2026 |
| PARKS IMPACT FEE 10-25 | ¤3,164.00 | 03/09/2026 |
| RECLAIM WATER PERMIT INSPECTIO | ¤40.00 | 03/09/2026 |
| RSI DRIVEWAY AFTER POUR | ¤16.25 | 03/09/2026 |
| RSE DRIVE PRE POUR INSPECTION | ¤32.50 | 03/09/2026 |
| RSI FIELD SURVEY INSPECTION | ¤48.75 | 03/09/2026 |
| RSI FORMBOARD REVIEW | ¤16.25 | 03/09/2026 |
| RSI PLAN REVIEW NEW | ¤48.75 | 03/09/2026 |
| RSI FNL SURVEY/GRADING CERT | ¤48.75 | 03/09/2026 |
| RSI ROW FINAL INSPECTION | ¤16.25 | 03/09/2026 |
| SURCHARGE FS 533.721 | ¤12.90 | 03/09/2026 |
| SURCHARGE - FS 468.631 | ¤19.35 | 03/09/2026 |
| TRANSP RES IMPACT FEE 10-25 | ¤6,691.75 | 03/09/2026 |
| TRANSP RES IMPACT FEE 10-25 | (¤6,691.75) | 03/09/2026 |
| WASTEWATER PERM INSPECTION | ¤80.00 | 03/09/2026 |
| WASTEWATER PERM REVIEW | ¤25.00 | 03/09/2026 |
| SEWER CAPITAL FACILITY | ¤2,368.69 | 03/09/2026 |
| WATER CAPITAL FACILITY FEE | ¤1,744.18 | 03/09/2026 |
| WATER PERMIT REVIEW | ¤25.00 | 03/09/2026 |
| SITE PLAN 30 | ¤30.00 | 03/09/2026 |
| WATER-METER | ¤874.47 | 03/09/2026 |
| WATER- TURN ON | ¤50.00 | 03/09/2026 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 03/09/2026 |
| INSPECTION - RESIDENTIAL | ¤981.75 | 03/09/2026 |
| PLAN REVIEW - RESIDENTIAL | ¤278.46 | 03/09/2026 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤12,446.33 |