I want to search for...

Permit #2026020180

Permit Details

Status: INSPECT

Parcel Id: 20-12-31-5562-00000-1770
CONDITIONED SPACE: 1970 sqft
GARAGE: 662 sqft
OPENED PORCH (WITH ROOF) : 225 sqft
Total Square Footage: 2857 sqft
Subdivision: 2362 - SEMINOLE PALMS SUBDIVISION PHASE 2
Job Phone: 904-422-5276
Location Address: 308 FISHTAIL PL
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 03/20/2026
NOC: RECORDED
Applicant name: MATTHEW JAMES HENSON
Owner: PULTE HOME COMPANY LLC

Address

12724 GRAN BAY PARKWAY WEST STE 200

JACKSONVILLE, FL 32258

Lot: 177
Contracted Stated Job Value: ¤160,000.00
Job Description: SFR
Type: CN

Contractor

PULTE HOME COMPANY LLC
Status Location Address Mailing Address State License Number Phone
ACTIVE

12724 GRAN BAY DRIVE PKWAY W

,

SUITE 140

JACKSONVILLE, FL 32258

CGC1514865 (Exp: 08/31/2026) 904-422-5276

Sub Contractors

PHILLIP F GABY
Status Location Address State License Number Phone
ACTIVE

PO BOX 56726

JACKSONVILLE, FL 32256

CCC1330190 (Exp: 08/31/2026) 904-424-4665
BRETT CHRISTIAN GIBSON
Status Location Address State License Number Phone
ACTIVE

250 SEGOVIA RD

ST AUGUSTINE, FL 32086

CAC1818423 (Exp: 08/31/2026) 904-229-8131
PAUL ERIC FORSTER
Status Location Address State License Number Phone
ACTIVE

6114 GOODMAN RD

JACKSONVILLE, FL 32244

CFC1429261 (Exp: 08/31/2026) 904-647-1820
JAMES E LINTON
Status Location Address State License Number Phone
ACTIVE

200 COLLEGE DR

ORANGE PARK, FL 32065

EC0001152 (Exp: 08/31/2026) 904-272-0272

Inspection History

Type Request Date Result Inspector
ROW- PRE-APRON (PRE-POUR) 06/05/2026 APPROVED FSLADISH
Note: 6/5/26 PREPOUR NOW MEETS COPC MINIMUM STANDARDS AT THE TIME OF THIS INSPECTION. AT THE TIME OF THE INSPECTION PREPOUR AREA IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD REMOVE ALL WATER AND CHECK COMPACTION BEFORE POURING CONCRETE. 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED IS REQUIRED. PLEASE REVIEW CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. NO EXPANSION JOINTS ALLOWED. __________________________________________________________________________________________________________________________________ 6/4/2026 - PREVIOUS INSPECTION NOTES 6/4/26 THIS IS NEWER BUILDER AND AS A COURTESY WENT OVER THE COPC REQUIREMENTS FOR SUBDIVISION NO CULVERT DRIVEWAYS, AS THE DRIVEWAY PREPOUR DID NOT MEET COPC STANDARDS AT THE TIME OF THIS INSPECTION. I LET CM KNOW THAT I WOULD CANCEL THIS PREPOUR AS A ONE TIME COURTESY AND TO RESUBMIT OR CALL FOR ASSISTANCE SHOULD THEY REQUIRE IT BEFORE RESUBMITTING FOR INSPECTION.
ROW- PRE-APRON (PRE-POUR) 06/04/2026 CANCELLED BY APPLICANT FSLADISH
Note: 6/4/26 THIS IS NEWER BUILDER AND AS A COURTESY WENT OVER THE COPC REQUIREMENTS FOR SUBDIVISION NO CULVERT DRIVEWAYS, AS THE DRIVEWAY PREPOUR DID NOT MEET COPC STANDARDS AT THE TIME OF THIS INSPECTION. I LET CM KNOW THAT I WOULD CANCEL THIS PREPOUR AS A ONE TIME COURTESY AND TO RESUBMIT OR CALL FOR ASSISTANCE SHOULD THEY REQUIRE IT BEFORE RESUBMITTING FOR INSPECTION.
GRAVITY SEWER TEST 06/01/2026 APPROVED RSIMS
Note: Approved on site.
SEWER TIE IN 06/01/2026 APPROVED RSIMS
Note: Approved on site.
SEWER TIE IN 05/29/2026 CANCELLED BY APPLICANT WEB
GRAVITY SEWER TEST 05/29/2026 CANCELLED BY APPLICANT WEB
DRYWALL NAILING 05/27/2026 APPROVED KSANDOE
INSULATION 05/20/2026 APPROVED RSIMS
Note: Inspector Notes from Inspection 2420 5/18/26: 1). Wire for Water Heater needs to be phased out. NEC 200.6(B) 2). Dryer duct and kitchen duct need to be sealed at the roof deck. FBCR M1601.4.1 Inspector Notes from Inspection 2467 R319.1 Address identification. Buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property. 4' minimum height with .5" stroke width Please add addresses to job boxes.
LATH/BRICK/ WATER BARRIER 05/18/2026 APPROVED RSIMS
Note: Inspector Notes from Inspection 2467 R319.1 Address identification. Buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property. 4' minimum height with .5" stroke width Please add addresses to job boxes.
ALL ROUGH 05/18/2026 APPROVED - AS NOTED RSIMS
Note: 5/18/26: 1). Wire for Water Heater needs to be phased out. NEC 200.6(B) 2). Dryer duct and kitchen duct need to be sealed at the roof deck. FBCR M1601.4.1 Inspector Notes from Inspection 2467 R319.1 Address identification. Buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property. 4' minimum height with .5" stroke width Please add addresses to job boxes.
ELECTRIC-TUG 05/14/2026 APPROVED - AS NOTED RSIMS
Note: 5/14/26: FPL emailed > Approved for TUG
ROOF VALLEY & METAL 05/05/2026 APPROVED - AS NOTED KSANDOE
Note: R319.1 Address identification. Buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property. 4' minimum height with .5" stroke width Please add addresses to job boxes.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 04/30/2026 APPROVED RSIMS
Note: 4/28/2026 - PREVIOUS INSPECTION NOTES 4/28/26: Partial approval for Roof Sheathing and Down Cell only due to missing plans. 1). No truss engineering packet in permit box or on site. Need plans on site for inspections. FBC [A]107.3.1
WALL SHEATHING 04/28/2026 APPROVED RSIMS
ROOF SHEATHING / BRACES/TIES/DOWN CELL 04/28/2026 PARTIALLY APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 4/28/2026 2:18:12 PM *** 1). No truss engineering packet in permit box or on site. Need plans on site for inspections. FBC [A]107.3.1 4/28/26: Partial approval for Roof Sheathing and Down Cell only due to missing plans. 1). No russ engineering packet in permit box or on site. Need plans on site for inspections. FBC [A]107.3.1
MONOLITHIC SLAB 04/16/2026 APPROVED RSIMS
Note: 4/15/2026 - PREVIOUS INSPECTION NOTES Clear minor cave ins Ensure proper clearance of steel to earth R404.1.3.3.7.4 Support and cover. Steel reinforcement in concrete cast against the earth shall have a minimum cover of 3 inches.
MONOLITHIC SLAB 04/15/2026 Disapproved - NO FEE KSANDOE
Note: Clear minor cave ins Ensure proper clearance of steel to earth R404.1.3.3.7.4 Support and cover. Steel reinforcement in concrete cast against the earth shall have a minimum cover of 3 inches.
PLUMBING 1ST ROUGH UNDERGROUND 04/13/2026 APPROVED RSIMS
Note: 4/13/26: Main underground water service piping is installed from house to meter valve (meter installed). Inspected and approved. RS ------------------------------------------------------------------------------------------------------------------------------- 4/9/2026 - PREVIOUS INSPECTION NOTES 4/9/26: Rain has caused significant dirt cave in preventing completion of the inspection. Please expose drain lines and water lines so that the required inspection can be completed. FBC-[A] 110.1
PLUMBING 1ST ROUGH UNDERGROUND 04/09/2026 Disapproved - NO FEE RSIMS
Note: 4/9/26: Rain has caused significant dirt cave in preventing completion of the inspection. Please expose drain lines and water lines so that the required inspection can be completed. FBC-[A] 110.1
FORMBOARD SURVEY (OFFICE USE ONLY) 04/08/2026 APPROVED RRICKS
WATER METER INSTALLATION REQUEST 04/01/2026 APPROVED ISANDERSON
PEP TANK INSTALLATION REQUEST
U-CROSS CONNECTION
BLD - BUILDING FINAL
ROW - FINAL APRON (AFTER POUR)
ROW - FINAL INSPECTION
U -UTILITY RESIDENTIAL FINAL
ELECTRIC - EARLY POWER

Review History

Department Status Date In Date Out
SW1 COMPLETE 04/08/2026 04/08/2026
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 04/08/2026 04/08/2026
Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM
BLD COMPLETE 03/30/2026 04/01/2026
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ZON COMPLETE 03/30/2026 03/30/2026
Note: Released By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM
ZON COMPLETE 03/18/2026 03/18/2026
Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM
ZON HOLD 03/05/2026 03/05/2026
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Site plan: Setsback being provided on site plan are incorrect rear should be 10'
BLD COMPLETE 03/05/2026 03/10/2026
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
SW1 COMPLETE 03/05/2026 03/11/2026
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
BLD HOLD 02/05/2026 02/10/2026
Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM Roofing Worksheet FL# 1932.1 not valid.
CUSVC COMPLETE 02/05/2026 02/13/2026
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 02/05/2026 02/09/2026
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 02/05/2026 02/06/2026
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
GAS CANCEL 02/05/2026 02/09/2026
LOCATE COMPLETE 02/05/2026 02/11/2026
Note: Released By: IVAN SANDERSON - -
MECH COMPLETE 02/05/2026 02/10/2026
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 HOLD 02/05/2026 02/11/2026
Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM - Please provide benchmark - Please provide the proposed FFE for the garage. - At the front of the home on the right side there are proposed slopes greater than 4:1. There shall be no slopes greater than 4:1.
ZON HOLD 02/05/2026 02/09/2026
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Floor plan: garage exceeds the depth of thirty feet. please adjust plan accordingly to seperate the garage from the storage area.
URB COMPLETE 02/05/2026 02/05/2026
Note: Released By: JOHN BEAUDET - (386)986-2456 - JBEAUDET@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
WATER-METER ¤874.47 03/20/2026
WATER- TURN ON ¤50.00 03/20/2026
ADMINISTRATIVE RESIDENTIAL ¤30.00 03/20/2026
INSPECTION - RESIDENTIAL ¤1,097.25 03/20/2026
PLAN REVIEW - RESIDENTIAL ¤311.22 03/20/2026
FC IMPACT FEE EMS ¤62.00 03/20/2026
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 03/20/2026
FC IMPACT FEE LIBRARY ¤268.00 03/20/2026
FIRE RES IMPACT FEE 10-25 ¤942.00 03/20/2026
WATER METER W/OUT TAP ¤965.03 03/20/2026
PARKS IMPACT FEE 10-25 ¤3,164.00 03/20/2026
RECLAIM WATER PERMIT INSPECTIO ¤40.00 03/20/2026
RSI DRIVEWAY AFTER POUR ¤16.25 03/20/2026
RSE DRIVE PRE POUR INSPECTION ¤32.50 03/20/2026
RSI FIELD SURVEY INSPECTION ¤48.75 03/20/2026
RSI FORMBOARD REVIEW ¤16.25 03/20/2026
RSI PLAN REVIEW NEW ¤48.75 03/20/2026
RSI FNL SURVEY/GRADING CERT ¤48.75 03/20/2026
RSI ROW FINAL INSPECTION ¤16.25 03/20/2026
SURCHARGE FS 533.721 ¤14.38 03/20/2026
SURCHARGE - FS 468.631 ¤21.58 03/20/2026
TRANSP RES IMPACT FEE 10-25 ¤7,426.90 03/20/2026
TRANSP RES IMPACT FEE 10-25 (¤7,426.90) 03/20/2026
WASTEWATER PERM INSPECTION ¤80.00 03/20/2026
WASTEWATER PERM REVIEW ¤25.00 03/20/2026
SEWER CAPITAL FACILITY ¤2,368.69 03/20/2026
WATER CAPITAL FACILITY FEE ¤1,744.18 03/20/2026
WATER PERMIT REVIEW ¤25.00 03/20/2026
SITE PLAN 30 ¤30.00 03/20/2026
Fees Total Due: ¤0.00 Total Paid: ¤12,558.30