I want to search for...

Permit #2026020193

Permit Details

Status: INSPECT

Parcel Id: 20-12-31-5562-00000-2400
CONDITIONED SPACE: 1581 sqft
GARAGE: 513 sqft
OPENED PORCH (WITH ROOF) : 195 sqft
Total Square Footage: 2289 sqft
Subdivision: 2362 - SEMINOLE PALMS SUBDIVISION PHASE 2
Job Phone: 904-422-5276
Location Address: 305 FISHTAIL PL
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 03/06/2026
NOC: RECORDED
Applicant name: MATTHEW JAMES HENSON
Owner: PULTE HOME COMPANY LLC

Address

12724 GRAN BAY PARKWAY WEST

JACKSONVILLE, FL 32258

Address

SUITE 200

JACKSONVILLE, FL 32258

Lot: 240
Contracted Stated Job Value: ¤160,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

PULTE HOME COMPANY LLC
Status Location Address Mailing Address State License Number Phone
ACTIVE

12724 GRAN BAY DRIVE PKWAY W

,

SUITE 140

JACKSONVILLE, FL 32258

CGC1514865 (Exp: 08/31/2026) 904-422-5276

Sub Contractors

PHILLIP F GABY
Status Location Address State License Number Phone
ACTIVE

PO BOX 56726

JACKSONVILLE, FL 32256

CCC1330190 (Exp: 08/31/2026) 904-424-4665
BRETT CHRISTIAN GIBSON
Status Location Address State License Number Phone
ACTIVE

250 SEGOVIA RD

ST AUGUSTINE, FL 32086

CAC1818423 (Exp: 08/31/2026) 904-229-8131
PAUL ERIC FORSTER
Status Location Address State License Number Phone
ACTIVE

6114 GOODMAN RD

JACKSONVILLE, FL 32244

CFC1429261 (Exp: 08/31/2026) 904-647-1820
JAMES E LINTON
Status Location Address State License Number Phone
ACTIVE

200 COLLEGE DR

ORANGE PARK, FL 32065

EC0001152 (Exp: 08/31/2026) 904-272-0272

Inspection History

Type Request Date Result Inspector
ROW- PRE-APRON (PRE-POUR) 05/22/2026 APPROVED FSLADISH
Note: 5/22/26 AT THE TIME OF THE INSPECTION PREPOUR AREA IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD REMOVE ALL WATER AND CHECK COMPACTION BEFORE POURING CONCRETE. 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED IS REQUIRED. PLEASE REVIEW CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. NO EXPANSION JOINTS ALLOWED.
DRYWALL NAILING 05/14/2026 APPROVED RSIMS
INSULATION 05/12/2026 APPROVED RSIMS
Note: 5/7/2026 - PREVIOUS INSPECTION NOTES 5/7/26: Previously listed deficiecy remains unresolved. 5/6/2026 - PREVIOUS INSPECTION NOTES FBC EC-Residential 402.4.1.1 Batts must extend over the top plate to ensure continuity of R value FRC 806.3 1' air gap required Inspector Notes from Inspection 2420 5/1/26: Check at Insulation. Previously listed items 4 and 5 remain unresolved. 4). Kitchen exhaust is missing the 3 evenly spaced screws at joints/connections. FBC-M1601.4.1 5). metal outlet box for security panel must be installed and bonded for this inspection. NEC-250.148(C). > Box is installed but ground wire is not securely attached to the bonding screw as required. Please wrap wire around screw to provide positive bond. 4/27/2026 - PREVIOUS INSPECTION NOTES 4/27/26: Water Meter is installed and line pressurized. 1). Missing plans in permit box / on site. All plans must remain on site and available for inspections. FBC [A]107.3.1 2). Electrical wires need to be drilled through a flat 2" x 4" above the breaker panel to provide required fireblocking per FBC-R302.11 3). Water heater and Condenser feed wires need to be phased at breaker panel. NEC 200.6(B) 4). Kitchen exhaust is missing the 3 evenly spaced screws at joints/connections. FBC-M1601.4.1 5). metal outlet box for security panel must be installed and bonded for this inspection. NEC-250.148(C). 3/18/26: Main underground water service piping is installed from house to meter location but did not have a pressure test on it so it will need to be exposed again at All Rough.
ELECTRIC - EARLY POWER 05/12/2026 CANCELLED BY APPLICANT RSIMS
Note: 5/12/26: Cancelled > called in too early.
INSULATION 05/07/2026 Disapproved -FEE REQUIRED RSIMS
Note: 5/7/26: Previously listed deficiecy remains unresolved. 5/6/2026 - PREVIOUS INSPECTION NOTES FBC EC-Residential 402.4.1.1 Batts must extend over the top plate to ensure continuity of R value FRC 806.3 1' air gap required Inspector Notes from Inspection 2420 5/1/26: Check at Insulation. Previously listed items 4 and 5 remain unresolved. 4). Kitchen exhaust is missing the 3 evenly spaced screws at joints/connections. FBC-M1601.4.1 5). metal outlet box for security panel must be installed and bonded for this inspection. NEC-250.148(C). > Box is installed but ground wire is not securely attached to the bonding screw as required. Please wrap wire around screw to provide positive bond. 4/27/2026 - PREVIOUS INSPECTION NOTES 4/27/26: Water Meter is installed and line pressurized. 1). Missing plans in permit box / on site. All plans must remain on site and available for inspections. FBC [A]107.3.1 2). Electrical wires need to be drilled through a flat 2" x 4" above the breaker panel to provide required fireblocking per FBC-R302.11 3). Water heater and Condenser feed wires need to be phased at breaker panel. NEC 200.6(B) 4). Kitchen exhaust is missing the 3 evenly spaced screws at joints/connections. FBC-M1601.4.1 5). metal outlet box for security panel must be installed and bonded for this inspection. NEC-250.148(C). 3/18/26: Main underground water service piping is installed from house to meter location but did not have a pressure test on it so it will need to be exposed again at All Rough.
INSULATION 05/06/2026 Disapproved - NO FEE KSANDOE
Note: FBC EC-Residential 402.4.1.1 Batts must extend over the top plate to ensure continuity of R value FRC 806.3 1' air gap required Inspector Notes from Inspection 2420 5/1/26: Check at Insulation. Previously listed items 4 and 5 remain unresolved. 4). Kitchen exhaust is missing the 3 evenly spaced screws at joints/connections. FBC-M1601.4.1 5). metal outlet box for security panel must be installed and bonded for this inspection. NEC-250.148(C). > Box is installed but ground wire is not securely attached to the bonding screw as required. Please wrap wire around screw to provide positive bond. 4/27/2026 - PREVIOUS INSPECTION NOTES 4/27/26: Water Meter is installed and line pressurized. 1). Missing plans in permit box / on site. All plans must remain on site and available for inspections. FBC [A]107.3.1 2). Electrical wires need to be drilled through a flat 2" x 4" above the breaker panel to provide required fireblocking per FBC-R302.11 3). Water heater and Condenser feed wires need to be phased at breaker panel. NEC 200.6(B) 4). Kitchen exhaust is missing the 3 evenly spaced screws at joints/connections. FBC-M1601.4.1 5). metal outlet box for security panel must be installed and bonded for this inspection. NEC-250.148(C). 3/18/26: Main underground water service piping is installed from house to meter location but did not have a pressure test on it so it will need to be exposed again at All Rough.
ALL ROUGH 05/01/2026 APPROVED - AS NOTED RSIMS
Note: 5/1/26: Check at Insulation. Previously listed items 4 and 5 remain unresolved. 4). Kitchen exhaust is missing the 3 evenly spaced screws at joints/connections. FBC-M1601.4.1 5). metal outlet box for security panel must be installed and bonded for this inspection. NEC-250.148(C). > Box is installed but ground wire is not securely attached to the bonding screw as required. Please wrap wire around screw to provide positive bond. 4/27/2026 - PREVIOUS INSPECTION NOTES 4/27/26: Water Meter is installed and line pressurized. 1). Missing plans in permit box / on site. All plans must remain on site and available for inspections. FBC [A]107.3.1 2). Electrical wires need to be drilled through a flat 2" x 4" above the breaker panel to provide required fireblocking per FBC-R302.11 3). Water heater and Condenser feed wires need to be phased at breaker panel. NEC 200.6(B) 4). Kitchen exhaust is missing the 3 evenly spaced screws at joints/connections. FBC-M1601.4.1 5). metal outlet box for security panel must be installed and bonded for this inspection. NEC-250.148(C). 3/18/26: Main underground water service piping is installed from house to meter location but did not have a pressure test on it so it will need to be exposed again at All Rough.
GRAVITY SEWER TEST 04/28/2026 APPROVED RSIMS
Note: 4/28/26: Virtually approved via FaceTime video/audio phone app at @ 0930. Inspector Notes from Inspection 2060 *** NOTES ADDED BY RSIMS 3/18/2026 2:19:12 PM *** 3/18/26: Main underground water service piping is installed from house to meter location but did not have a pressure test on it so it will need to be exposed again at All Rough.
SEWER TIE IN 04/28/2026 APPROVED RSIMS
Note: 4/28/26: Virtually approved via FaceTime video/audio phone app at @ 0930. Inspector Notes from Inspection 2060 *** NOTES ADDED BY RSIMS 3/18/2026 2:19:12 PM *** 3/18/26: Main underground water service piping is installed from house to meter location but did not have a pressure test on it so it will need to be exposed again at All Rough.
ALL ROUGH 04/27/2026 Disapproved - NO FEE RSIMS
Note: *** NOTES ADDED BY RSIMS 4/27/2026 11:24:05 AM *** 4/27/26: Water Meter is installed and line pressurized. 1). Missing plans in permit box / on site. All plans must remain on site and available for inspections. FBC [A]107.3.1 2). Electrical wires need to be drilled through a flat 2" x 4" above the breaker panel to provide required fireblocking per FBC-R302.11 3). Water heater and Condenser feed wires need to be phased at breaker panel. NEC 200.6(B) 4). Kitchen exhaust is missing the 3 evenly spaced screws at joints/connections. FBC-M1601.4.1 5). metal outlet box for security panel must be installed and bonded for this inspection. NEC-250.148(C). 3/18/26: Main underground water service piping is installed from house to meter location but did not have a pressure test on it so it will need to be exposed again at All Rough.
LATH/BRICK/ WATER BARRIER 04/22/2026 APPROVED RSIMS
Note: Inspector Notes from Inspection 2467 Check zip tape on 5x5 at water barrier inspection 4/13/2026 - PREVIOUS INSPECTION NOTES 4/13/26: 1). 5" x 5" wall flashing must be sealed / taped to the zip wall plywood. FBC-R903.2
ELECTRIC-TUG 04/21/2026 APPROVED KSANDOE
ROOF VALLEY & METAL 04/14/2026 APPROVED - AS NOTED KSANDOE
Note: Check zip tape on 5x5 at water barrier inspection 4/13/2026 - PREVIOUS INSPECTION NOTES 4/13/26: 1). 5" x 5" wall flashing must be sealed / taped to the zip wall plywood. FBC-R903.2
ROOF VALLEY & METAL 04/13/2026 Disapproved - NO FEE RSIMS
Note: *** NOTES ADDED BY RSIMS 4/13/2026 2:22:18 PM *** 4/13/26: 1). 5" x 5" wall flashing must be sealed / taped to the zip wall plywood. FBC-R903.2
WALL SHEATHING 04/02/2026 APPROVED RSIMS
ROOF SHEATHING / BRACES/TIES/DOWN CELL 04/02/2026 APPROVED RSIMS
WATER METER INSTALLATION REQUEST 04/01/2026 APPROVED ISANDERSON
MONOLITHIC SLAB 03/20/2026 APPROVED KSANDOE
PLUMBING 1ST ROUGH UNDERGROUND 03/18/2026 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 3/18/2026 2:19:12 PM *** 3/18/26: Main underground water service piping is installed from house to meter location but did not have a pressure test on it so it will need to be exposed again at All Rough.
FORMBOARD SURVEY (OFFICE USE ONLY) 03/17/2026 APPROVED PFLANAGAN
ELECTRIC - EARLY POWER
Note: 5/12/2026 - PREVIOUS INSPECTION NOTES 5/12/26: Cancelled > called in too early.
U-CROSS CONNECTION
BLD - BUILDING FINAL
ROW - FINAL APRON (AFTER POUR)
ROW- FINAL SURVEY/GRADING CERTIFICATION
ROW - FINAL INSPECTION
U -UTILITY RESIDENTIAL FINAL

Review History

Department Status Date In Date Out
MECH COMPLETE 04/20/2026 04/20/2026
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 03/30/2026 04/01/2026
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ZON COMPLETE 03/30/2026 03/30/2026
Note: Released By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM
SW1 COMPLETE 03/17/2026 03/17/2026
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON COMPLETE 03/17/2026 03/17/2026
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
ZON COMPLETE 03/02/2026 03/02/2026
Note: Released By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM
ZON HOLD 02/27/2026 02/27/2026
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Provide correct setbacks please you all have them listed at 15' it's10
BLD COMPLETE 02/27/2026 03/04/2026
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
SW1 COMPLETE 02/27/2026 03/05/2026
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
BLD HOLD 02/05/2026 02/10/2026
Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM Roofing Worksheet FL# 1932.1 not valid
CUSVC COMPLETE 02/05/2026 02/13/2026
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 02/05/2026 02/09/2026
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 02/05/2026 02/06/2026
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
GAS CANCEL 02/05/2026 02/09/2026
LOCATE COMPLETE 02/05/2026 02/11/2026
Note: Released By: IVAN SANDERSON - -
MECH COMPLETE 02/05/2026 02/10/2026
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 HOLD 02/05/2026 02/11/2026
Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM - Please provide benchmark - Please provide the proposed FFE for the garage.
ZON HOLD 02/05/2026 02/09/2026
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM site plan: missing width of walkway.
URB COMPLETE 02/05/2026 02/09/2026
Note: Released By: JOHN BEAUDET - (386)986-2456 - JBEAUDET@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 05/07/2026
PLAN REVIEW - REVISION ¤32.50 05/06/2026
WATER-METER ¤874.47 03/06/2026
WATER- TURN ON ¤50.00 03/06/2026
ADMINISTRATIVE RESIDENTIAL ¤30.00 03/06/2026
INSPECTION - RESIDENTIAL ¤880.00 03/06/2026
PLAN REVIEW - RESIDENTIAL ¤249.60 03/06/2026
FC IMPACT FEE EMS ¤62.00 03/06/2026
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 03/06/2026
FC IMPACT FEE LIBRARY ¤268.00 03/06/2026
FIRE RES IMPACT FEE 10-25 ¤942.00 03/06/2026
WATER METER W/OUT TAP ¤965.03 03/06/2026
PARKS IMPACT FEE 10-25 ¤3,164.00 03/06/2026
RECLAIM WATER PERMIT INSPECTIO ¤40.00 03/06/2026
RSI DRIVEWAY AFTER POUR ¤16.25 03/06/2026
RSE DRIVE PRE POUR INSPECTION ¤32.50 03/06/2026
RSI FIELD SURVEY INSPECTION ¤48.75 03/06/2026
RSI FORMBOARD REVIEW ¤16.25 03/06/2026
RSI PLAN REVIEW NEW ¤48.75 03/06/2026
RSI FNL SURVEY/GRADING CERT ¤48.75 03/06/2026
RSI ROW FINAL INSPECTION ¤16.25 03/06/2026
SURCHARGE FS 533.721 ¤11.60 03/06/2026
SURCHARGE - FS 468.631 ¤17.39 03/06/2026
TRANSP RES IMPACT FEE 10-25 ¤5,960.37 03/06/2026
TRANSP RES IMPACT FEE 10-25 (¤5,960.37) 03/06/2026
WASTEWATER PERM INSPECTION ¤80.00 03/06/2026
WASTEWATER PERM REVIEW ¤25.00 03/06/2026
SEWER CAPITAL FACILITY ¤2,368.69 03/06/2026
WATER CAPITAL FACILITY FEE ¤1,744.18 03/06/2026
WATER PERMIT REVIEW ¤25.00 03/06/2026
SITE PLAN 30 ¤30.00 03/06/2026
Fees Total Due: ¤0.00 Total Paid: ¤12,344.96