Permit #2026020347

Permit Details

Status: FINAL

Parcel Id: 06-12-31-5180-00000-0450
Subdivision: 2322 - RETREAT AT TOWN CENTER PHASE 1
Job Phone: 386-999-1042
Location Address: 26 MAHOGANY WAY
Type: PO - POOL
Issue Date: 03/10/2026
NOC: RECORDED
Applicant name: RYDER N BRAY
Owner: MCEVOY JEAN M & RICHARD S ROSE JTWROS

Address

26 MAHOGANY WAY

PALM COAST, FL 32164

Lot: 45
Contracted Stated Job Value: ¤130,000.00
Job Description: POOL WITH SCREEN ENCLOSURE
Type: CN

Contractor

HAVEN POOLS LLC
Status Location Address State License Number Phone
ACTIVE

25 PUTTER LANE

PALM COAST, FL 32164

CPC1460243 (Exp: 08/31/2026) 386-999-1042

Sub Contractors

JOHN EDWARD GAMBONE
Status Location Address Mailing Address State License Number Phone
ACTIVE

15 HARGROVE LN

PALM COAST, FL 32137

1G

PALM COAST, FL 32137

EC13006037 (Exp: 08/31/2026) 386-586-9144
JOSEPH DEREK CARTWRIGHT
Status Location Address State License Number Phone Fax
ACTIVE

151 RODEO ROAD

ORMOND BEACH, FL 32174

SCC131150000 (Exp: 08/31/2026) 386-310-7962 (386)615-3713

Inspection History

Type Request Date Result Inspector
POOL FINAL 06/03/2026 FINAL APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 6/3/2026 3:23:18 PM *** Final Approved New inspection due to canceled inspection 5/19/2026 - PREVIOUS INSPECTION NOTES 5/19/26: 1). As noted on 5/11/26 > hurricane pad for heater is cracked all the way through on the back side. This pad needs to be replaced. 2). Heater needs to be anchored at 4 points per Manufacturer and FBC-M1307.1 & FBC-M1307.2 3). Numerous cables for screen enclosure have excessive slack. Manufacturer requires zero slack per plans. FBC [A]107.4 5/11/26: Observed during the Gas rough inspection related to this permit: hurricane pad for Pool Heater is cracked all the way through on the back side and will need to be replaced to properly anchor the appliance. FBC-M1307.1 & FBC-M1307.2
POOL FINAL 06/02/2026 CANCELLED BY APPLICANT WEB
Note: 5/19/2026 - PREVIOUS INSPECTION NOTES 5/19/26: 1). As noted on 5/11/26 > hurricane pad for heater is cracked all the way through on the back side. This pad needs to be replaced. 2). Heater needs to be anchored at 4 points per Manufacturer and FBC-M1307.1 & FBC-M1307.2 3). Numerous cables for screen enclosure have excessive slack. MManufacturer requires zero slack per plans. FBC [A]107.4 5/11/26: Observed during the Gas rough inspection related to this permit: hurricane pad for Pool Heater is cracked all the way through on the back side and will need to be replaced to properly anchor the appliance. FBC-M1307.1 & FBC-M1307.2
POOL FINAL 05/19/2026 Disapproved -FEE REQUIRED RSIMS
Note: 5/19/26: 1). As noted on 5/11/26 > hurricane pad for heater is cracked all the way through on the back side. This pad needs to be replaced. 2). Heater needs to be anchored at 4 points per Manufacturer and FBC-M1307.1 & FBC-M1307.2 3). Numerous cables for screen enclosure have excessive slack. MManufacturer requires zero slack per plans. FBC [A]107.4 5/11/26: Observed during the Gas rough inspection related to this permit: hurricane pad for Pool Heater is cracked all the way through on the back side and will need to be replaced to properly anchor the appliance. FBC-M1307.1 & FBC-M1307.2
U -UTILITY RESIDENTIAL FINAL 05/08/2026 FINAL APPROVED BHAINES
ROW FIELD SURVEY /GRADING CERTIFICATION 05/07/2026 APPROVED FSLADISH
Note: 5/7/26 REQUIRED CORRETIONS COMPLETED AT THE TIME OF THIS INSPECTION. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S AND/OR HOMEOWNER’S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. _______________________________________________________________________________________________________________________________ 4/23/2026 - PREVIOUS INSPECTION NOTES 4/23/26 BUILDER IS REQUIRED TO SOD ON THE LEFT SIDE PROPERTY LINE A MINIMUM OF 5 FOOT PAST WHERE BARE EARTH AREA WAS DISTURBED. YOU ARE ALSO REQUIRED TO REMOVE CONCRETE AND CONSTRUCTION DEBRIS FROM REAR SLOPE. YOU WILL ALSO NEED TO RAKE/FILL IN WHERE NEEDED/ COMPACT AND SOD ENTIRE REAR SLOPE TO STABILIZE AGAINST WASHOUT/EROSION. PINNING OF SOD MAY BE NECCESSARY TO HOLD SLOPE/GRADE. SEE PHOTO FOR REFERENCE.
ROW - FINAL INSPECTION 05/07/2026 APPROVED FSLADISH
Note: 5/7/26 REQUIRED CORRETIONS COMPLETED AT THE TIME OF THIS INSPECTION. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S AND/OR HOMEOWNER’S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
ROW- FINAL SURVEY/GRADING CERTIFICATION 04/23/2026 APPROVED FSLADISH
ROW FIELD SURVEY /GRADING CERTIFICATION 04/23/2026 Disapproved - NO FEE FSLADISH
Note: 4/23/26 BUILDER IS REQUIRED TO SOD ON THE LEFT SIDE PROPERTY LINE A MINIMUM OF 5 FOOT PAST WHERE BARE EARTH AREA WAS DISTURBED. YOU ARE ALSO REQUIRED TO REMOVE CONCRETE AND CONSTRUCTION DEBRIS FROM REAR SLOPE. YOU WILL ALSO NEED TO RAKE/FILL IN WHERE NEEDED/ COMPACT AND SOD ENTIRE REAR SLOPE TO STABILIZE AGAINST WASHOUT/EROSION. PINNING OF SOD MAY BE NECCESSARY TO HOLD SLOPE/GRADE. SEE PHOTO FOR REFERENCE.
ELECTRIC AND ALARM 04/16/2026 APPROVED - AS NOTED CVANSTRAHLEN
Note: 4/16/2026 - inspection 2620 Gas permit needs to be pulled for the gas line/equipment that is installed, also the PVC conduit run along the house needs better supports per NEC 352.30 Table. The carflex under the meter can not be exposed to physical damage per NEC 356.12 it is at grass level. 4/14/2026 - PREVIOUS INSPECTION NOTES Gas permit needs to be pulled for the gas line/equipment that is installed, also the PVC conduit run along the house needs better supports per NEC 352.30 Table. The carflex under the meter can not be exposed to physical damage per NEC 356.12 it is at grass level.
ELECTRIC AND ALARM 04/14/2026 Disapproved -FEE REQUIRED RMARTIN
Note: Gas permit needs to be pulled for the gas line/equipment that is installed, also the PVC conduit run along the house needs better supports per NEC 352.30 Table. The carflex under the meter can not be exposed to physical damage per NEC 356.12 it is at grass level.
POOL DECK 03/24/2026 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 3/24/2026 9:15:11 AM *** Approved
STEEL AND GROUND 03/16/2026 APPROVED CVANSTRAHLEN
Note: 3/13/2026 - PREVIOUS INSPECTION NOTES No plans on side , no permit Please have all documents on side for inspection FBC [A] 105.7-NEEDS PERMIT ON SITE FBC [A]107.3.1-NEEDS APPROVED PLANS ON SITE
STEEL AND GROUND 03/13/2026 Disapproved - NO FEE CVANSTRAHLEN
Note: No plans on side , no permit Please have all documents on side for inspection FBC [A] 105.7-NEEDS PERMIT ON SITE FBC [A]107.3.1-NEEDS APPROVED PLANS ON SITE

Review History

Department Status Date In Date Out
ZON COMPLETE 03/04/2026 03/04/2026
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
BLD COMPLETE 03/04/2026 03/10/2026
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
ZON HOLD 02/25/2026 02/25/2026
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM screen plans dont show the sides of the enclosiure and the pool equiptment must meet a 3' setback in all zoning districts unless you have permission from the HOA aprroving the 1'.6" setback and it needs to clearly state that.
RSI COMPLETE 02/25/2026 02/27/2026
Note: Released By: EDWARD MADISON - (386)986-4770 - EMADISON@PALMCOASTGOV.COM
ZON HOLD 02/18/2026 02/18/2026
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM deck does'nt meet the Left side setback of 5'
MECH COMPLETE 02/18/2026 02/23/2026
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
RSI HOLD 02/18/2026 02/25/2026
Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM THE SITE PLAN DOESN'T MATCH THE EXISTING GRADE THAT WAS DONE FROM THE BUILDER ALL WATER MUST FLOW FROM BACK TO FRONT AS WHEN THE HOUSE WAS BUILT. PLEASE REVISE SITE PLAN TO REFLECT ALL WATER TO FLOE FROM BACK PROPERTY LINE TO THE FRONT CURB AND GUTTER.
BLD COMPLETE 02/18/2026 02/23/2026
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
BFLOOD COMPLETE 02/10/2026 02/12/2026
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD HOLD 02/10/2026 02/17/2026
Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM 1. To site plan add landings as per FBCR 311.3 2. Please indicate in pool plans the deck footer that will be used for screen enclosure.
ELEC COMPLETE 02/10/2026 02/17/2026
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH HOLD 02/10/2026 02/12/2026
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide gas riser diagram and list gas subcontractor or put note on plans "Gas By Others"
RSI HOLD 02/10/2026 02/17/2026
Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM PLEASE PROVIDE ARROWS BEHIND POOL TO SHOW NEW DRAINAGE
ZON HOLD 02/10/2026 02/10/2026
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Please add the dimensions on the side of the screen enclosure all side needed

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 06/01/2026
REINSPECTION RESIDENTIAL ¤40.00 04/15/2026
ADMINISTRATIVE RESIDENTIAL ¤30.00 03/10/2026
INSPECTION- POOL ¤160.00 03/10/2026
PLAN REVIEW - RESIDENTIAL ¤101.40 03/10/2026
RSI FIELD SURVEY INSPECTION ¤48.75 03/10/2026
RSI PLAN REVIEW NEW ¤48.75 03/10/2026
RSI FNL SURVEY/GRADING CERT ¤48.75 03/10/2026
RSI ROW FINAL INSPECTION ¤16.25 03/10/2026
SURCHARGE FS 533.721 ¤2.91 03/10/2026
SURCHARGE - FS 468.631 ¤4.37 03/10/2026
SITE PLAN 30 ¤30.00 03/10/2026
Fees Total Due: ¤0.00 Total Paid: ¤571.18