Permit #2026020380
Permit Details
Status: INSPECT
| Parcel Id: 07-11-31-7024-00440-0450 |
| Block: 00440 |
| Subdivision: - |
| Job Phone: 904-780-0078 |
| Location Address: 72 PRATTWOOD LN |
| Type: ME - MECHANICAL |
| Issue Date: 02/11/2026 |
| NOC: Unknown |
| Applicant name: DMITRIY GONCHAROV |
| Owner: STEVEN F KRAEGER |
|
Address 72 PRATTWOOD LANE PALM COAST, FL 32164 |
| Lot: 0450 |
| Contracted Stated Job Value: ¤6,500.00 |
| Job Description: Like for Like chnage out |
| Type: CN |
Contractor
CREDIBLE AC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
13603 HOLLINGS ST , |
CAC1820672 (Exp: 08/31/2026) | 904-780-0078 |
Inspection History
| Type | Request Date | Result | Inspector |
| HVAC FINAL | 02/20/2026 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 2/20/2026 10:32:58 AM *** 2/20/26: A Virtual inspection will be available IF requested at the time of scheduling the re-inspection. If requesting a Virtual Re-inspection, please schedule the re-inspection for the same day that the deficiencies will be corrected and a FaceTime or Google Meet live virtual inspection can be completed. (Pictures are not approved). REQUESTED VIRTUAL INSPECTIONS MUST BE COMPLETED BY 3PM IN ORDER TO BE UPDATED IN THE SYSTEM. 1). Permit, AHRI documents need to be on site for inspection. FBC [A] 105.7 / FBC [A]107.3.1 2). Breaker for AHU is too small. (Min.-44amp / Max.-45amp - 40amp installed). NEC 440.4 3). Supply duct needs to be sealed along the front at the ceiling where it enters the attic. FBC-R302.11(4) / FBCR M1601.4.1 | |||
| HVAC FINAL | |||
| Note: 2/20/2026 - PREVIOUS INSPECTION NOTES 2/20/26: A Virtual inspection will be available IF requested at the time of scheduling the re-inspection. If requesting a Virtual Re-inspection, please schedule the re-inspection for the same day that the deficiencies will be corrected and a FaceTime or Google Meet live virtual inspection can be completed. (Pictures are not approved). REQUESTED VIRTUAL INSPECTIONS MUST BE COMPLETED BY 3PM IN ORDER TO BE UPDATED IN THE SYSTEM. 1). Permit, AHRI documents need to be on site for inspection. FBC [A] 105.7 / FBC [A]107.3.1 2). Breaker for AHU is too small. (Min.-44amp / Max.-45amp - 40amp installed). NEC 440.4 3). Supply duct needs to be sealed along the front at the ceiling where it enters the attic. FBC-R302.11(4) / FBCR M1601.4.1 |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 05/04/2026 |
| SURCHARGE FS 533.721 | ¤2.00 | 02/11/2026 |
| SURCHARGE - FS 468.631 | ¤2.00 | 02/11/2026 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 02/11/2026 |
| INSPECTION - MECHANICAL | ¤60.00 | 02/11/2026 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤134.00 |