Permit Details

Status: INSPECT

Parcel Id: 07-11-31-7024-00440-0450
Block: 00440
Subdivision: -
Job Phone: 904-780-0078
Location Address: 72 PRATTWOOD LN
Type: ME - MECHANICAL
Issue Date: 02/11/2026
NOC: Unknown
Applicant name: DMITRIY GONCHAROV
Owner: STEVEN F KRAEGER

Address

72 PRATTWOOD LANE

PALM COAST, FL 32164

Lot: 0450
Contracted Stated Job Value: ¤6,500.00
Job Description: Like for Like chnage out
Type: CN

Contractor

CREDIBLE AC
Status Location Address State License Number Phone
ACTIVE

13603 HOLLINGS ST

,

CAC1820672 (Exp: 08/31/2026) 904-780-0078

Inspection History

Type Request Date Result Inspector
HVAC FINAL 02/20/2026 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 2/20/2026 10:32:58 AM *** 2/20/26: A Virtual inspection will be available IF requested at the time of scheduling the re-inspection. If requesting a Virtual Re-inspection, please schedule the re-inspection for the same day that the deficiencies will be corrected and a FaceTime or Google Meet live virtual inspection can be completed. (Pictures are not approved). REQUESTED VIRTUAL INSPECTIONS MUST BE COMPLETED BY 3PM IN ORDER TO BE UPDATED IN THE SYSTEM. 1). Permit, AHRI documents need to be on site for inspection. FBC [A] 105.7 / FBC [A]107.3.1 2). Breaker for AHU is too small. (Min.-44amp / Max.-45amp - 40amp installed). NEC 440.4 3). Supply duct needs to be sealed along the front at the ceiling where it enters the attic. FBC-R302.11(4) / FBCR M1601.4.1
HVAC FINAL
Note: 2/20/2026 - PREVIOUS INSPECTION NOTES 2/20/26: A Virtual inspection will be available IF requested at the time of scheduling the re-inspection. If requesting a Virtual Re-inspection, please schedule the re-inspection for the same day that the deficiencies will be corrected and a FaceTime or Google Meet live virtual inspection can be completed. (Pictures are not approved). REQUESTED VIRTUAL INSPECTIONS MUST BE COMPLETED BY 3PM IN ORDER TO BE UPDATED IN THE SYSTEM. 1). Permit, AHRI documents need to be on site for inspection. FBC [A] 105.7 / FBC [A]107.3.1 2). Breaker for AHU is too small. (Min.-44amp / Max.-45amp - 40amp installed). NEC 440.4 3). Supply duct needs to be sealed along the front at the ceiling where it enters the attic. FBC-R302.11(4) / FBCR M1601.4.1

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 05/04/2026
SURCHARGE FS 533.721 ¤2.00 02/11/2026
SURCHARGE - FS 468.631 ¤2.00 02/11/2026
ADMINISTRATIVE RESIDENTIAL ¤30.00 02/11/2026
INSPECTION - MECHANICAL ¤60.00 02/11/2026
Fees Total Due: ¤0.00 Total Paid: ¤134.00