I want to search for...
Permit #2026020395
Permit Details
Status: INSPECT
| Parcel Id: 07-11-31-7030-00150-0020 |
| CONDITIONED SPACE: 1504 sqft |
| GARAGE: 396 sqft |
| OPENED PORCH (WITH ROOF) : 112 sqft |
| Total Square Footage: 2012 sqft |
| Block: 00150 |
| Subdivision: 2154 - SECTION 30-ROYAL PALMS |
| Job Phone: 407-476-8195 |
| Location Address: 9 RAINROCK PL |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 04/01/2026 |
| NOC: RECORDED |
| Applicant name: CARLETTE RENE WITTE |
| Owner: INB BFS LAND LLC |
|
Address 7380 W SAND LAKE ROAD ORLANDO, FL 32819 |
|
Address SUITE 600 ORLANDO, FL 32819 |
| Lot: 0020 |
| Contracted Stated Job Value: ¤250,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
INNOVATIVE NATIONWIDE BUILDERS INC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3670 MAGUIRE BLVD #220 , |
CRC1330026 (Exp: 08/31/2026) | 855-694-6634 |
Sub Contractors
JASON LEE JAMES
| Status | Location Address | State License Number | Phone |
| ACTIVE |
217 N WESTMONTE DR SUITE 1007 ALTAMONTE SPRINGS, FL 32714 |
CAC1820196 (Exp: 08/31/2026) | 407-404-4000 |
ANTHONY OKEITH FENNELL
| Status | Location Address | State License Number | Phone |
| ACTIVE |
217 N. WESTMONTE DR, SUITE 1007 ALTAMONTE SPRINGS, FL 32714 |
EC13011194 (Exp: 08/31/2026) | 407-404-4000 |
HEATH EDWARD SANFORD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
126 EAST END RD SAN MATEO, FL 32187 |
CFC1429896 (Exp: 08/31/2026) | 386-871-8823 |
TERRY BRICE DICKERSON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4300 ST JOHN'S PARKWAY ALPHARETTA, GA 30009 |
CCC1326209 (Exp: 08/31/2026) | 407-548-6733 |
Inspection History
| Type | Request Date | Result | Inspector |
| TIE BEAM / LINTEL | 06/11/2026 | Disapproved -FEE REQUIRED | CVANSTRAHLEN |
| Note: Please fix items before next inspection Items #1 and #2 are been fix Item #3 not been fix . new Dowels on cilinders block are been place but not tie , please tie new dowels to existen down dowels #1- please clean up work construction area 6/10/2026 - PREVIOUS INSPECTION NOTES Please fix items before next inspection #1-FBC 3303.5-SWALE CLEAR #2-FBC 3302.2-NEEDS DUMPSTER #3-FBCR 608.5.4.1-CLEARANCE OF REBAR 3" TO SOIL, 1.5" TO REMOVEABLE FORM EXPOSED TO EARTH 2" #6 AND LARGER ( Mark with orange spray , total 4 ) | |||
| TIE BEAM / LINTEL | 06/10/2026 | Disapproved -FEE REQUIRED | CVANSTRAHLEN |
| Note: Please fix items before next inspection #1-FBC 3303.5-SWALE CLEAR #2-FBC 3302.2-NEEDS DUMPSTER #3-FBCR 608.5.4.1-CLEARANCE OF REBAR 3" TO SOIL, 1.5" TO REMOVEABLE FORM EXPOSED TO EARTH 2" #6 AND LARGER ( Mark with orange spray , total 4 ) | |||
| MONOLITHIC SLAB | 06/02/2026 | APPROVED | CVANSTRAHLEN |
| Note: 5/29/2026 - PREVIOUS INSPECTION NOTES Items from previous inspection not been fix all mark with orange spray 5/27/2026 - PREVIOUS INSPECTION NOTES Please fix items before next inspection Items from previous inspection not been fix #1-FBC-R404.1.3.3.7.4-Florida Building Code, structural steel (rebar) that is cast against or directly touching the ground must have a minimum of 3 inches of concrete clearance. ( se slab page , all mark with green sharpie market #2-FBC R404.1.3.3.7.5-SLAB MINIMUM THICKNESS 3 1/2 " master bedroom area by window and garage wall required to be compacted , slab must be 3.1/2 tick concreted(footers required by plans to be 1'8" some around the areas have 1'7" 5/22/2026 - PREVIOUS INSPECTION NOTES Please fix items before next inspection #1-FBC-R404.1.3.3.7.4-Florida Building Code, structural steel (rebar) that is cast against or directly touching the ground must have a minimum of 3 inches of concrete clearance. ( se slab page , all mark with green sharpie market #2-FBCRP2603.4-SLEEVE PLUMBING OR PROVIDE A RELIEVING ARCH THROUGH FOUNDATION WALL (garage hose bibb , ) | |||
| MONOLITHIC SLAB | 05/29/2026 | Disapproved -FEE REQUIRED | CVANSTRAHLEN |
| Note: Items from previous inspection not been fix all mark with orange spray 5/27/2026 - PREVIOUS INSPECTION NOTES Please fix items before next inspection Items from previous inspection not been fix #1-FBC-R404.1.3.3.7.4-Florida Building Code, structural steel (rebar) that is cast against or directly touching the ground must have a minimum of 3 inches of concrete clearance. ( se slab page , all mark with green sharpie market #2-FBC R404.1.3.3.7.5-SLAB MINIMUM THICKNESS 3 1/2 " master bedroom area by window and garage wall required to be compacted , slab must be 3.1/2 tick concreted(footers required by plans to be 1'8" some around the areas have 1'7" 5/22/2026 - PREVIOUS INSPECTION NOTES Please fix items before next inspection #1-FBC-R404.1.3.3.7.4-Florida Building Code, structural steel (rebar) that is cast against or directly touching the ground must have a minimum of 3 inches of concrete clearance. ( se slab page , all mark with green sharpie market #2-FBCRP2603.4-SLEEVE PLUMBING OR PROVIDE A RELIEVING ARCH THROUGH FOUNDATION WALL (garage hose bibb , ) | |||
| MONOLITHIC SLAB | 05/27/2026 | Disapproved -FEE REQUIRED | CVANSTRAHLEN |
| Note: Please fix items before next inspection #1-FBC-R404.1.3.3.7.4-Florida Building Code, structural steel (rebar) that is cast against or directly touching the ground must have a minimum of 3 inches of concrete clearance. ( se slab page , all mark with green sharpie market #2-FBC R404.1.3.3.7.5-SLAB MINIMUM THICKNESS 3 1/2 " master bedroom area by window and garage wall required to be compacted , slab must be 3.1/2 tick concreted 5/22/2026 - PREVIOUS INSPECTION NOTES Please fix items before next inspection #1-FBC-R404.1.3.3.7.4-Florida Building Code, structural steel (rebar) that is cast against or directly touching the ground must have a minimum of 3 inches of concrete clearance. ( se slab page , all mark with green sharpie market #2-FBCRP2603.4-SLEEVE PLUMBING OR PROVIDE A RELIEVING ARCH THROUGH FOUNDATION WALL (garage hose bibb , ) | |||
| MONOLITHIC SLAB | 05/22/2026 | Disapproved - NO FEE | CVANSTRAHLEN |
| Note: Please fix items before next inspection #1-FBC-R404.1.3.3.7.4-Florida Building Code, structural steel (rebar) that is cast against or directly touching the ground must have a minimum of 3 inches of concrete clearance. ( se slab page , all mark with green sharpie market #2-FBCRP2603.4-SLEEVE PLUMBING OR PROVIDE A RELIEVING ARCH THROUGH FOUNDATION WALL (garage hose bibb , ) | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 05/20/2026 | APPROVED | CVANSTRAHLEN |
| GRAVITY SEWER TEST | 05/20/2026 | APPROVED | CVANSTRAHLEN |
| FORMBOARD SURVEY (OFFICE USE ONLY) | 05/19/2026 | APPROVED | PFLANAGAN |
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | 05/18/2026 | APPROVED | PKNAPIK |
| WATER METER INSTALLATION REQUEST | 05/01/2026 | APPROVED | ISANDERSON |
| Note: 4/29/2026 10:11:12 AM- PREVIOUS INSPECTION NOTES Lot not cleared | |||
| WATER METER INSTALLATION REQUEST | 04/28/2026 | Disapproved - NO FEE | ISANDERSON |
| Note: Lot not cleared | |||
| PEP TANK INSTALLATION REQUEST | |||
| U-CROSS CONNECTION | |||
| ROW- PRE-APRON (PRE-POUR) | |||
| ROW - FINAL APRON (AFTER POUR) | |||
| ROW - FINAL INSPECTION | |||
| U -UTILITY RESIDENTIAL FINAL | |||
| LATH/BRICK/ WATER BARRIER | |||
| SEWER TIE IN | |||
| ELECTRIC - EARLY POWER | |||
| TIE BEAM / LINTEL | |||
| Note: 6/11/2026 - PREVIOUS INSPECTION NOTES Please fix items before next inspection Items #1 and #2 are been fix Item #3 not been fix . new Dowels on cilinders block are been place but not tie , please tie new dowels to existen down dowels #1- please clean up work construction area 6/10/2026 - PREVIOUS INSPECTION NOTES Please fix items before next inspection #1-FBC 3303.5-SWALE CLEAR #2-FBC 3302.2-NEEDS DUMPSTER #3-FBCR 608.5.4.1-CLEARANCE OF REBAR 3" TO SOIL, 1.5" TO REMOVEABLE FORM EXPOSED TO EARTH 2" #6 AND LARGER ( Mark with orange spray , total 4 ) | |||
| ALL ROUGH | |||
| WALL SHEATHING | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | |||
| ROOF VALLEY & METAL | |||
| INSULATION | |||
| DRYWALL NAILING | |||
| BLD - BUILDING FINAL |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 05/18/2026 | 05/18/2026 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 05/18/2026 | 05/19/2026 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 05/18/2026 | 05/18/2026 |
| Note: Released By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 03/13/2026 | 03/18/2026 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 03/13/2026 | 03/16/2026 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 03/03/2026 | 03/06/2026 |
| Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Previous comment about berm is not addressed: Based on the information provided, the berm is not needed on the left side of this lot. Please remove the berm and keep the interior swale elevations the same. | |||
| ENGIN1 | COMPLETE | 03/03/2026 | 03/06/2026 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 02/12/2026 | 02/25/2026 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 02/11/2026 | 02/18/2026 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM 1. Please upload Product Approval Form. | |||
| CUSVC | COMPLETE | 02/11/2026 | 02/20/2026 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 02/11/2026 | 02/18/2026 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 02/11/2026 | 02/12/2026 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 02/11/2026 | 02/13/2026 |
| LOCATE | COMPLETE | 02/11/2026 | 02/19/2026 |
| Note: Released By: IVAN SANDERSON - - | |||
| MECH | COMPLETE | 02/11/2026 | 02/13/2026 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 02/11/2026 | 02/13/2026 |
| Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM - The majority of the berm on the left side is not needed. Based on the information provided there is 0.3' minimum fall from the 10' shot on the adjacent lot. - Please certify FFE of lot 1(the lot is incorrectly depicted on the grading plan as lot 3). 10' shots don't agree with the FFE. | |||
| ZON | COMPLETE | 02/11/2026 | 02/13/2026 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| FC IMPACT FEE EMS | ¤62.00 | 04/01/2026 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 04/01/2026 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 04/01/2026 |
| FIRE RES IMPACT FEE 10-25 | ¤942.00 | 04/01/2026 |
| PEP TANK INSTALL | ¤756.74 | 04/01/2026 |
| PARKS IMPACT FEE 10-25 | ¤3,164.00 | 04/01/2026 |
| RSI DRIVEWAY AFTER POUR | ¤16.25 | 04/01/2026 |
| RSE DRIVE PRE POUR INSPECTION | ¤32.50 | 04/01/2026 |
| RSI FIELD SURVEY INSPECTION | ¤48.75 | 04/01/2026 |
| RSI FORMBOARD REVIEW | ¤16.25 | 04/01/2026 |
| RSI PLAN REVIEW NEW | ¤48.75 | 04/01/2026 |
| RSI FNL SURVEY/GRADING CERT | ¤48.75 | 04/01/2026 |
| RSI ROW FINAL INSPECTION | ¤16.25 | 04/01/2026 |
| SCHOOL BOARD IMPACT FEE RES | ¤5,450.00 | 04/01/2026 |
| WASTEWATER MAIN EXTENSION IMPA | ¤2,385.00 | 04/01/2026 |
| SURCHARGE FS 533.721 | ¤10.64 | 04/01/2026 |
| SURCHARGE - FS 468.631 | ¤15.96 | 04/01/2026 |
| SW ENG RES REVIEW 240 | ¤240.00 | 04/01/2026 |
| WATER METER W/ TAP | ¤2,326.93 | 04/01/2026 |
| TRANSP RES IMPACT FEE 10-25 | ¤5,670.08 | 04/01/2026 |
| SEWER CREDIT | (¤1,147.00) | 04/01/2026 |
| WASTEWATER PERM INSPECTION | ¤80.00 | 04/01/2026 |
| WASTEWATER PERM REVIEW | ¤25.00 | 04/01/2026 |
| SEWER CAPITAL FACILITY | ¤4,415.00 | 04/01/2026 |
| WATER CAPITAL FACILITY FEE | ¤3,790.49 | 04/01/2026 |
| WATER PERMIT REVIEW | ¤25.00 | 04/01/2026 |
| WATER MAIN EXTENSION IMPACT | ¤917.27 | 04/01/2026 |
| SITE PLAN 30 | ¤30.00 | 04/01/2026 |
| WATER- TURN ON | ¤50.00 | 04/01/2026 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 04/01/2026 |
| INSPECTION - RESIDENTIAL | ¤805.75 | 04/01/2026 |
| PLAN REVIEW - RESIDENTIAL | ¤228.54 | 04/01/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | |
| REINSPECTION RESIDENTIAL | ¤40.00 | |
| REINSPECTION RESIDENTIAL | ¤40.00 | |
| REINSPECTION RESIDENTIAL | ¤40.00 | |
| Fees | Total Due: ¤160.00 | Total Paid: ¤30,986.90 |