I want to search for...

Permit #2026020395

Permit Details

Status: INSPECT

Parcel Id: 07-11-31-7030-00150-0020
CONDITIONED SPACE: 1504 sqft
GARAGE: 396 sqft
OPENED PORCH (WITH ROOF) : 112 sqft
Total Square Footage: 2012 sqft
Block: 00150
Subdivision: 2154 - SECTION 30-ROYAL PALMS
Job Phone: 407-476-8195
Location Address: 9 RAINROCK PL
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 04/01/2026
NOC: RECORDED
Applicant name: CARLETTE RENE WITTE
Owner: INB BFS LAND LLC

Address

7380 W SAND LAKE ROAD

ORLANDO, FL 32819

Address

SUITE 600

ORLANDO, FL 32819

Lot: 0020
Contracted Stated Job Value: ¤250,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

INNOVATIVE NATIONWIDE BUILDERS INC
Status Location Address State License Number Phone
ACTIVE

3670 MAGUIRE BLVD #220

,

CRC1330026 (Exp: 08/31/2026) 855-694-6634

Sub Contractors

JASON LEE JAMES
Status Location Address State License Number Phone
ACTIVE

217 N WESTMONTE DR SUITE 1007

ALTAMONTE SPRINGS, FL 32714

CAC1820196 (Exp: 08/31/2026) 407-404-4000
ANTHONY OKEITH FENNELL
Status Location Address State License Number Phone
ACTIVE

217 N. WESTMONTE DR, SUITE 1007

ALTAMONTE SPRINGS, FL 32714

EC13011194 (Exp: 08/31/2026) 407-404-4000
HEATH EDWARD SANFORD
Status Location Address State License Number Phone
ACTIVE

126 EAST END RD

SAN MATEO, FL 32187

CFC1429896 (Exp: 08/31/2026) 386-871-8823
TERRY BRICE DICKERSON
Status Location Address State License Number Phone
ACTIVE

4300 ST JOHN'S PARKWAY

ALPHARETTA, GA 30009

CCC1326209 (Exp: 08/31/2026) 407-548-6733

Inspection History

Type Request Date Result Inspector
TIE BEAM / LINTEL 06/11/2026 Disapproved -FEE REQUIRED CVANSTRAHLEN
Note: Please fix items before next inspection Items #1 and #2 are been fix Item #3 not been fix . new Dowels on cilinders block are been place but not tie , please tie new dowels to existen down dowels #1- please clean up work construction area 6/10/2026 - PREVIOUS INSPECTION NOTES Please fix items before next inspection #1-FBC 3303.5-SWALE CLEAR #2-FBC 3302.2-NEEDS DUMPSTER #3-FBCR 608.5.4.1-CLEARANCE OF REBAR 3" TO SOIL, 1.5" TO REMOVEABLE FORM EXPOSED TO EARTH 2" #6 AND LARGER ( Mark with orange spray , total 4 )
TIE BEAM / LINTEL 06/10/2026 Disapproved -FEE REQUIRED CVANSTRAHLEN
Note: Please fix items before next inspection #1-FBC 3303.5-SWALE CLEAR #2-FBC 3302.2-NEEDS DUMPSTER #3-FBCR 608.5.4.1-CLEARANCE OF REBAR 3" TO SOIL, 1.5" TO REMOVEABLE FORM EXPOSED TO EARTH 2" #6 AND LARGER ( Mark with orange spray , total 4 )
MONOLITHIC SLAB 06/02/2026 APPROVED CVANSTRAHLEN
Note: 5/29/2026 - PREVIOUS INSPECTION NOTES Items from previous inspection not been fix all mark with orange spray 5/27/2026 - PREVIOUS INSPECTION NOTES Please fix items before next inspection Items from previous inspection not been fix #1-FBC-R404.1.3.3.7.4-Florida Building Code, structural steel (rebar) that is cast against or directly touching the ground must have a minimum of 3 inches of concrete clearance. ( se slab page , all mark with green sharpie market #2-FBC R404.1.3.3.7.5-SLAB MINIMUM THICKNESS 3 1/2 " master bedroom area by window and garage wall required to be compacted , slab must be 3.1/2 tick concreted(footers required by plans to be 1'8" some around the areas have 1'7" 5/22/2026 - PREVIOUS INSPECTION NOTES Please fix items before next inspection #1-FBC-R404.1.3.3.7.4-Florida Building Code, structural steel (rebar) that is cast against or directly touching the ground must have a minimum of 3 inches of concrete clearance. ( se slab page , all mark with green sharpie market #2-FBCRP2603.4-SLEEVE PLUMBING OR PROVIDE A RELIEVING ARCH THROUGH FOUNDATION WALL (garage hose bibb , )
MONOLITHIC SLAB 05/29/2026 Disapproved -FEE REQUIRED CVANSTRAHLEN
Note: Items from previous inspection not been fix all mark with orange spray 5/27/2026 - PREVIOUS INSPECTION NOTES Please fix items before next inspection Items from previous inspection not been fix #1-FBC-R404.1.3.3.7.4-Florida Building Code, structural steel (rebar) that is cast against or directly touching the ground must have a minimum of 3 inches of concrete clearance. ( se slab page , all mark with green sharpie market #2-FBC R404.1.3.3.7.5-SLAB MINIMUM THICKNESS 3 1/2 " master bedroom area by window and garage wall required to be compacted , slab must be 3.1/2 tick concreted(footers required by plans to be 1'8" some around the areas have 1'7" 5/22/2026 - PREVIOUS INSPECTION NOTES Please fix items before next inspection #1-FBC-R404.1.3.3.7.4-Florida Building Code, structural steel (rebar) that is cast against or directly touching the ground must have a minimum of 3 inches of concrete clearance. ( se slab page , all mark with green sharpie market #2-FBCRP2603.4-SLEEVE PLUMBING OR PROVIDE A RELIEVING ARCH THROUGH FOUNDATION WALL (garage hose bibb , )
MONOLITHIC SLAB 05/27/2026 Disapproved -FEE REQUIRED CVANSTRAHLEN
Note: Please fix items before next inspection #1-FBC-R404.1.3.3.7.4-Florida Building Code, structural steel (rebar) that is cast against or directly touching the ground must have a minimum of 3 inches of concrete clearance. ( se slab page , all mark with green sharpie market #2-FBC R404.1.3.3.7.5-SLAB MINIMUM THICKNESS 3 1/2 " master bedroom area by window and garage wall required to be compacted , slab must be 3.1/2 tick concreted 5/22/2026 - PREVIOUS INSPECTION NOTES Please fix items before next inspection #1-FBC-R404.1.3.3.7.4-Florida Building Code, structural steel (rebar) that is cast against or directly touching the ground must have a minimum of 3 inches of concrete clearance. ( se slab page , all mark with green sharpie market #2-FBCRP2603.4-SLEEVE PLUMBING OR PROVIDE A RELIEVING ARCH THROUGH FOUNDATION WALL (garage hose bibb , )
MONOLITHIC SLAB 05/22/2026 Disapproved - NO FEE CVANSTRAHLEN
Note: Please fix items before next inspection #1-FBC-R404.1.3.3.7.4-Florida Building Code, structural steel (rebar) that is cast against or directly touching the ground must have a minimum of 3 inches of concrete clearance. ( se slab page , all mark with green sharpie market #2-FBCRP2603.4-SLEEVE PLUMBING OR PROVIDE A RELIEVING ARCH THROUGH FOUNDATION WALL (garage hose bibb , )
PLUMBING 1ST ROUGH UNDERGROUND 05/20/2026 APPROVED CVANSTRAHLEN
GRAVITY SEWER TEST 05/20/2026 APPROVED CVANSTRAHLEN
FORMBOARD SURVEY (OFFICE USE ONLY) 05/19/2026 APPROVED PFLANAGAN
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 05/18/2026 APPROVED PKNAPIK
WATER METER INSTALLATION REQUEST 05/01/2026 APPROVED ISANDERSON
Note: 4/29/2026 10:11:12 AM- PREVIOUS INSPECTION NOTES Lot not cleared
WATER METER INSTALLATION REQUEST 04/28/2026 Disapproved - NO FEE ISANDERSON
Note: Lot not cleared
PEP TANK INSTALLATION REQUEST
U-CROSS CONNECTION
ROW- PRE-APRON (PRE-POUR)
ROW - FINAL APRON (AFTER POUR)
ROW - FINAL INSPECTION
U -UTILITY RESIDENTIAL FINAL
LATH/BRICK/ WATER BARRIER
SEWER TIE IN
ELECTRIC - EARLY POWER
TIE BEAM / LINTEL
Note: 6/11/2026 - PREVIOUS INSPECTION NOTES Please fix items before next inspection Items #1 and #2 are been fix Item #3 not been fix . new Dowels on cilinders block are been place but not tie , please tie new dowels to existen down dowels #1- please clean up work construction area 6/10/2026 - PREVIOUS INSPECTION NOTES Please fix items before next inspection #1-FBC 3303.5-SWALE CLEAR #2-FBC 3302.2-NEEDS DUMPSTER #3-FBCR 608.5.4.1-CLEARANCE OF REBAR 3" TO SOIL, 1.5" TO REMOVEABLE FORM EXPOSED TO EARTH 2" #6 AND LARGER ( Mark with orange spray , total 4 )
ALL ROUGH
WALL SHEATHING
ROOF SHEATHING / BRACES/TIES/DOWN CELL
ROOF VALLEY & METAL
INSULATION
DRYWALL NAILING
BLD - BUILDING FINAL

Review History

Department Status Date In Date Out
BLD COMPLETE 05/18/2026 05/18/2026
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
SW1 COMPLETE 05/18/2026 05/19/2026
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON COMPLETE 05/18/2026 05/18/2026
Note: Released By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM
SW1 COMPLETE 03/13/2026 03/18/2026
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ENGIN1 COMPLETE 03/13/2026 03/16/2026
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
SW1 HOLD 03/03/2026 03/06/2026
Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Previous comment about berm is not addressed: Based on the information provided, the berm is not needed on the left side of this lot. Please remove the berm and keep the interior swale elevations the same.
ENGIN1 COMPLETE 03/03/2026 03/06/2026
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
SWALE COMPLETE 02/12/2026 02/25/2026
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
BLD COMPLETE 02/11/2026 02/18/2026
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM 1. Please upload Product Approval Form.
CUSVC COMPLETE 02/11/2026 02/20/2026
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 02/11/2026 02/18/2026
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 02/11/2026 02/12/2026
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
GAS CANCEL 02/11/2026 02/13/2026
LOCATE COMPLETE 02/11/2026 02/19/2026
Note: Released By: IVAN SANDERSON - -
MECH COMPLETE 02/11/2026 02/13/2026
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 HOLD 02/11/2026 02/13/2026
Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM - The majority of the berm on the left side is not needed. Based on the information provided there is 0.3' minimum fall from the 10' shot on the adjacent lot. - Please certify FFE of lot 1(the lot is incorrectly depicted on the grading plan as lot 3). 10' shots don't agree with the FFE.
ZON COMPLETE 02/11/2026 02/13/2026
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
FC IMPACT FEE EMS ¤62.00 04/01/2026
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 04/01/2026
FC IMPACT FEE LIBRARY ¤268.00 04/01/2026
FIRE RES IMPACT FEE 10-25 ¤942.00 04/01/2026
PEP TANK INSTALL ¤756.74 04/01/2026
PARKS IMPACT FEE 10-25 ¤3,164.00 04/01/2026
RSI DRIVEWAY AFTER POUR ¤16.25 04/01/2026
RSE DRIVE PRE POUR INSPECTION ¤32.50 04/01/2026
RSI FIELD SURVEY INSPECTION ¤48.75 04/01/2026
RSI FORMBOARD REVIEW ¤16.25 04/01/2026
RSI PLAN REVIEW NEW ¤48.75 04/01/2026
RSI FNL SURVEY/GRADING CERT ¤48.75 04/01/2026
RSI ROW FINAL INSPECTION ¤16.25 04/01/2026
SCHOOL BOARD IMPACT FEE RES ¤5,450.00 04/01/2026
WASTEWATER MAIN EXTENSION IMPA ¤2,385.00 04/01/2026
SURCHARGE FS 533.721 ¤10.64 04/01/2026
SURCHARGE - FS 468.631 ¤15.96 04/01/2026
SW ENG RES REVIEW 240 ¤240.00 04/01/2026
WATER METER W/ TAP ¤2,326.93 04/01/2026
TRANSP RES IMPACT FEE 10-25 ¤5,670.08 04/01/2026
SEWER CREDIT (¤1,147.00) 04/01/2026
WASTEWATER PERM INSPECTION ¤80.00 04/01/2026
WASTEWATER PERM REVIEW ¤25.00 04/01/2026
SEWER CAPITAL FACILITY ¤4,415.00 04/01/2026
WATER CAPITAL FACILITY FEE ¤3,790.49 04/01/2026
WATER PERMIT REVIEW ¤25.00 04/01/2026
WATER MAIN EXTENSION IMPACT ¤917.27 04/01/2026
SITE PLAN 30 ¤30.00 04/01/2026
WATER- TURN ON ¤50.00 04/01/2026
ADMINISTRATIVE RESIDENTIAL ¤30.00 04/01/2026
INSPECTION - RESIDENTIAL ¤805.75 04/01/2026
PLAN REVIEW - RESIDENTIAL ¤228.54 04/01/2026
REINSPECTION RESIDENTIAL ¤40.00
REINSPECTION RESIDENTIAL ¤40.00
REINSPECTION RESIDENTIAL ¤40.00
REINSPECTION RESIDENTIAL ¤40.00
Fees Total Due: ¤160.00 Total Paid: ¤30,986.90