I want to search for...
Permit #2026020417
Permit Details
Status: INSPECT
| Parcel Id: 07-11-31-7037-00340-0050 |
| CONDITIONED SPACE: 1563 sqft |
| GARAGE: 414 sqft |
| OPENED PORCH (WITH ROOF) : 95 sqft |
| Total Square Footage: 2072 sqft |
| Block: 00340 |
| Subdivision: 2176 - SECTION 37-LAKEVIEW |
| Job Phone: 386-254-5081 |
| Location Address: 9 LAMAR LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 03/04/2026 |
| NOC: RECORDED |
| Applicant name: WILLIAM BRYAN ADAMS SR |
| Owner: ADAMS HOMES OF NORTHWEST FLORIDA INC |
|
Address 100 WEST GARDEN STREET PENSACOLA, FL 32502 |
|
Address SECOND FLOOR PENSACOLA, FL 32502 |
| Lot: 0050 |
| Contracted Stated Job Value: ¤165,000.00 |
| Job Description: Single Family Residence |
| Type: CN |
Contractor
ADAMS HOMES OF NORTHWEST FLORIDA, INC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3000 GULF BREEZE PARKWAY GULD BREEZE, FL 32563 |
CRC1330146 (Exp: 08/31/2026) | 386-254-5081 |
Sub Contractors
MICHAEL THACKABERRY
| Status | Location Address | State License Number | Phone |
| ACTIVE |
18115 DEMKO RD ALTOONA, FL 32702 |
CCC1336911 (Exp: 08/31/2026) | 517-499-5016 |
TIMUR ISPARYAN
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
3665 SPRINK PARK ROAD JACKSONVILLE , FL 32207 |
CMC1249968 (Exp: 08/31/2026) | 904-245-1818 | 904-337-1910 |
JOSEPH HORATIO STRADA JR
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3400 ST JOHNS PARKWAY SANFORD, FL 32771 |
EC13003715 (Exp: 08/31/2026) | 877-906-1113 |
ROBERTO F GONZALEZ
| Status | Location Address | State License Number | Phone |
| ACTIVE |
212 PALMETTO AVE CRESCENT CITY, FL 32112 |
RF11067887 (Exp: 08/31/2027) | 286-559-2885 |
Inspection History
| Type | Request Date | Result | Inspector |
| INSULATION | 06/09/2026 | Disapproved -FEE REQUIRED | JSTEWART |
| Note: Previous Notes not rectified....... 3. Master exhaust duct at fan assembly needs to be sealed and mechanically fastened to the assembly. FBCR M1601.4.1 4. Spare bath exhaust duct needs re sealed at roof penetration. FBCR M1601.4.1 Please repair all air Baffles (crushed). Min clearence between roof deck and insulation is 1". baffles should extend to the outer edge of the exterior wall line, as to not impede the air flow. FBC R806.3 Vent and insulation clearance / FBC R402.2.3 Eave baffle Inspector Notes from Inspection 2420 1. Please fasten SER within 12" of entering sub panel. NEC 334.30 2. Please repair SER at the top plate (disconnect wall) sheathing cut by nail shield. NEC 300.4(C) 3. Master exhaust duct at fan assembly needs to be sealed and mechanically fastened to the assembly. FBCR M1601.4.1 4. Spare bath exhaust duct needs re sealed at roof penetration. FBCR M1601.4.1 Will check at Insulation. | |||
| ALL ROUGH | 06/04/2026 | APPROVED - AS NOTED | JSTEWART |
| Note: 1. Please fasten SER within 12" of entering sub panel. NEC 334.30 2. Please repair SER at the top plate (disconnect wall) sheathing cut by nail shield. NEC 300.4(C) 3. Master exhaust duct at fan assembly needs to be sealed and mechanically fastened to the assembly. FBCR M1601.4.1 4. Spare bath exhaust duct needs re sealed at roof penetration. FBCR M1601.4.1 Will check at Insulation. | |||
| ROOF VALLEY & METAL | 05/20/2026 | APPROVED | MCONTRYMAN |
| WALL SHEATHING | 05/18/2026 | APPROVED | JSTEWART |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 05/18/2026 | APPROVED | JSTEWART |
| MONOLITHIC SLAB | 05/04/2026 | APPROVED | KSANDOE |
| PLUMBING 1ST ROUGH UNDERGROUND | 04/29/2026 | APPROVED | JSTEWART |
| FORMBOARD SURVEY (OFFICE USE ONLY) | 04/28/2026 | APPROVED | RRICKS |
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | 04/23/2026 | APPROVED | PKNAPIK |
| WATER METER INSTALLATION REQUEST | 04/02/2026 | APPROVED | ISANDERSON |
| PEP TANK INSTALLATION REQUEST | |||
| U-CROSS CONNECTION | |||
| ROW- PRE-APRON (PRE-POUR) | |||
| ROW - FINAL APRON (AFTER POUR) | |||
| ROW - FINAL INSPECTION | |||
| U -UTILITY RESIDENTIAL FINAL | |||
| INSULATION | |||
| Note: 6/9/2026 - PREVIOUS INSPECTION NOTES Previous Notes not rectified....... 3. Master exhaust duct at fan assembly needs to be sealed and mechanically fastened to the assembly. FBCR M1601.4.1 4. Spare bath exhaust duct needs re sealed at roof penetration. FBCR M1601.4.1 Please repair all air Baffles (crushed). Min clearence between roof deck and insulation is 1". baffles should extend to the outer edge of the exterior wall line, as to not impede the air flow. FBC R806.3 Vent and insulation clearance / FBC R402.2.3 Eave baffle Inspector Notes from Inspection 2420 1. Please fasten SER within 12" of entering sub panel. NEC 334.30 2. Please repair SER at the top plate (disconnect wall) sheathing cut by nail shield. NEC 300.4(C) 3. Master exhaust duct at fan assembly needs to be sealed and mechanically fastened to the assembly. FBCR M1601.4.1 4. Spare bath exhaust duct needs re sealed at roof penetration. FBCR M1601.4.1 Will check at Insulation. | |||
| DRYWALL NAILING | |||
| BLD - BUILDING FINAL | |||
| LATH/BRICK/ WATER BARRIER | |||
| GRAVITY SEWER TEST | |||
| SEWER TIE IN | |||
| ELECTRIC - EARLY POWER |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 04/27/2026 | 04/28/2026 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 04/27/2026 | 04/27/2026 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 04/23/2026 | 04/23/2026 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 04/08/2026 | 04/08/2026 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 02/25/2026 | 02/25/2026 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 02/17/2026 | 02/17/2026 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 02/11/2026 | 02/17/2026 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 02/11/2026 | 02/20/2026 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 02/11/2026 | 02/18/2026 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 02/11/2026 | 02/12/2026 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 02/11/2026 | 02/13/2026 |
| LOCATE | COMPLETE | 02/11/2026 | 02/19/2026 |
| Note: Released By: IVAN SANDERSON - - | |||
| MECH | COMPLETE | 02/11/2026 | 02/13/2026 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 02/11/2026 | 02/13/2026 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ZON | HOLD | 02/11/2026 | 02/13/2026 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Floor plan missing the open patio of 160 sq ft ont the plan to be included |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| FC IMPACT FEE EMS | ¤62.00 | 03/04/2026 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 03/04/2026 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 03/04/2026 |
| FIRE RES IMPACT FEE 10-25 | ¤942.00 | 03/04/2026 |
| PEP TANK INSTALL | ¤756.74 | 03/04/2026 |
| PARKS IMPACT FEE 10-25 | ¤3,164.00 | 03/04/2026 |
| RSI DRIVEWAY AFTER POUR | ¤16.25 | 03/04/2026 |
| RSE DRIVE PRE POUR INSPECTION | ¤32.50 | 03/04/2026 |
| RSI FIELD SURVEY INSPECTION | ¤48.75 | 03/04/2026 |
| RSI FORMBOARD REVIEW | ¤16.25 | 03/04/2026 |
| RSI PLAN REVIEW NEW | ¤48.75 | 03/04/2026 |
| RSI FNL SURVEY/GRADING CERT | ¤48.75 | 03/04/2026 |
| RSI ROW FINAL INSPECTION | ¤16.25 | 03/04/2026 |
| SCHOOL BOARD IMPACT FEE RES | ¤5,450.00 | 03/04/2026 |
| WASTEWATER MAIN EXTENSION IMPA | ¤2,385.00 | 03/04/2026 |
| SURCHARGE FS 533.721 | ¤11.00 | 03/04/2026 |
| SURCHARGE - FS 468.631 | ¤16.49 | 03/04/2026 |
| SW ENG RES REVIEW 240 | ¤240.00 | 03/04/2026 |
| WATER METER W/ TAP | ¤2,326.93 | 03/04/2026 |
| TRANSP RES IMPACT FEE 10-25 | ¤5,892.51 | 03/04/2026 |
| SEWER CREDIT | (¤1,693.92) | 03/04/2026 |
| WASTEWATER PERM INSPECTION | ¤80.00 | 03/04/2026 |
| WASTEWATER PERM REVIEW | ¤25.00 | 03/04/2026 |
| SEWER CAPITAL FACILITY | ¤4,415.00 | 03/04/2026 |
| WATER CREDIT | (¤85.02) | 03/04/2026 |
| WATER CAPITAL FACILITY FEE | ¤3,790.49 | 03/04/2026 |
| WATER PERMIT REVIEW | ¤25.00 | 03/04/2026 |
| WATER MAIN EXTENSION IMPACT | ¤917.27 | 03/04/2026 |
| SITE PLAN 30 | ¤30.00 | 03/04/2026 |
| WATER- TURN ON | ¤50.00 | 03/04/2026 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 03/04/2026 |
| INSPECTION - RESIDENTIAL | ¤833.25 | 03/04/2026 |
| PLAN REVIEW - RESIDENTIAL | ¤236.34 | 03/04/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | |
| Fees | Total Due: ¤40.00 | Total Paid: ¤30,613.58 |