Permit #2026020462
Permit Details
Status: COED
| Parcel Id: 04-11-30-5571-00000-1880 |
| CONDITIONED SPACE: 1638 sqft |
| GARAGE: 420 sqft |
| OPENED PORCH (WITH ROOF) : 96 sqft |
| OPENED PORCH (WITH ROOF) : 112 sqft |
| Total Square Footage: 2266 sqft |
| Subdivision: 2366 - SOMERSET SUBDIVISION PH 2 |
| Job Phone: 904-596-6645 |
| Location Address: 91 GOLDEN BELL AVE |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 02/27/2026 |
| NOC: RECORDED |
| Applicant name: MICHAEL T HOLDER |
| Owner: KB HOME JACKSONVILLE LLC |
|
Address 10475 FORTUNE PARKWAY JACKSONVILLE, FL 32256 |
|
Address SUITE 100 JACKSONVILLE, FL 32256 |
| Lot: 188 |
| Contracted Stated Job Value: ¤140,000.00 |
| Job Description: SINGLE FAMILY DWELLING |
| Type: CN |
Contractor
KB HOME JACKSONVILLE, LLC
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
10475 FORTUNE PKWY JACKSONVILLE, FL 32256 |
SUITE 100 JACKSONVILLE, FL 32256 |
CGC1509034 (Exp: 08/31/2026) | 904-596-6645 |
Sub Contractors
LARRY WILLIAMS
| Status | Location Address | State License Number | Phone |
| ACTIVE |
1750 EMERSON ST JACKSONVILLE, FL 32207 |
LI45034 (Exp: 08/31/2026) | 904-721-5431 |
BOBBY WAYNE CAMPBELL
| Status | Location Address | State License Number | Phone |
| ACTIVE |
117 GUTHRIE ROAD GREEN COVE SPRINGS, FL 32043 |
CCC1326752 (Exp: 08/31/2026) | 904-200-1600 |
JAMES E LINTON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
200 COLLEGE DR ORANGE PARK, FL 32065 |
EC0001152 (Exp: 08/31/2026) | 904-272-0272 |
COREY MICHAEL TENNANT
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3370 AGRICULTURAL CNETER DR ST AUGUSTINE, FL 32092 |
CAC1819063 (Exp: 08/31/2026) | 904-829-8898 |
BENJAMIN MICHAEL RAY
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| ACTIVE |
6310 MABLETON PKWY JACKSONVILLE, FL 32216 |
SUITE 1000 MABLETON, GA 30126 |
CFC1428415 (Exp: 08/31/2026) | 904-861-5421 | 904-861-5426 |
Inspection History
| Type | Request Date | Result | Inspector |
| ROW - FINAL INSPECTION | 06/03/2026 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED 6/1/2026 - PREVIOUS INSPECTION NOTES ** 06/01/26 BUILDER IS REQURED TO INSTALL EITHER SOD OT THE MESH EROSION CONTROL BARRIER ACROSS THE ADJACENT VACANT LOT ON THE LEFT AND RIGHT SIDES OF THIS PROPERTY TO AID IN EROSION CONTROL. ** THE CURB AND GUTTER NEEDS TO BE CLEANED OF THE ERODED SEDIMENT TO PREVENT IT FROM ENTERING THE STORM DRAINAGE SYSTEM ** SEE ATTACHED PHOTOS | |||
| U -UTILITY RESIDENTIAL FINAL | 06/01/2026 | APPROVED | BVEIGA |
| Note: Inspector Notes from Inspection 9035 No CC, IRR with reclaim | |||
| ROW - FINAL APRON (AFTER POUR) | 06/01/2026 | APPROVED | EMADISON |
| Note: ** AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW - FINAL INSPECTION | 06/01/2026 | Disapproved -FEE REQUIRED | EMADISON |
| Note: ** 06/01/26 BUILDER IS REQURED TO INSTALL EITHER SOD OT THE MESH EROSION CONTROL BARRIER ACROSS THE ADJACENT VACANT LOT ON THE LEFT AND RIGHT SIDES OF THIS PROPERTY TO AID IN EROSION CONTROL. ** THE CURB AND GUTTER NEEDS TO BE CLEANED OF THE ERODED SEDIMENT TO PREVENT IT FROM ENTERING THE STORM DRAINAGE SYSTEM ** SEE ATTACHED PHOTOS | |||
| BLD - BUILDING FINAL | 05/26/2026 | FINAL APPROVED | HCAMACHO |
| Note: 5/22/2026 - PREVIOUS INSPECTION NOTES 1. No Hot water in the house. P607.2/ B110 2. Missing locking caps on the A/C. FBCR M1411.8 3. Missing the wip on the dishwasher. | |||
| U-CROSS CONNECTION | 05/22/2026 | APPROVED - AS NOTED | BHAINES |
| Note: No CC, IRR with reclaim | |||
| BLD - BUILDING FINAL | 05/22/2026 | Disapproved - NO FEE | HCAMACHO |
| Note: 1. No Hot water in the house. P607.2/ B110 2. Missing locking caps on the A/C. FBCR M1411.8 3. Missing the wip on the dishwasher. | |||
| ELECTRIC - EARLY POWER | 05/04/2026 | APPROVED | JSTEWART |
| Note: Inspector Notes from Inspection 2200 Authorize release of email. | |||
| ROW- PRE-APRON (PRE-POUR) | 04/20/2026 | APPROVED | EMADISON |
| Note: ** 04/20/26 ** READY TO POUR ** AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE | |||
| DRYWALL NAILING | 04/09/2026 | APPROVED | JSTEWART |
| INSULATION | 04/06/2026 | APPROVED | JSTEWART |
| ELECTRIC-TUG | 04/06/2026 | APPROVED - AS NOTED | JSTEWART |
| Note: Authorize release of email. | |||
| LATH/BRICK/ WATER BARRIER | 03/31/2026 | Disapproved - NO FEE | JSTEWART |
| Note: Missing water barrier (self adhesive tape) at (2) porch column posts at the base. | |||
| LATH/BRICK/ WATER BARRIER | 03/31/2026 | APPROVED | JSTEWART |
| Note: Live virtual inspection, correction complete. 3/31/2026 - PREVIOUS INSPECTION NOTES Missing water barrier (self adhesive tape) at (2) porch column posts at the base. | |||
| ALL ROUGH | 03/31/2026 | APPROVED - AS NOTED | JSTEWART |
| Note: 1. Missing switch holding box in spare bath. 2. Please re seal dryer duct roof penetration. 3. install 3 screws at hood duct lap joint top of 22* angle adapter. 4. Under floor conduit for island being installed will check at insulation. | |||
| GRAVITY SEWER TEST | 03/30/2026 | APPROVED | JSTEWART |
| Note: Live Virtual Inspection. NOTE: Main water line from utility tap to Building installed. Inspector Notes from Inspection 2060 Main water line from utility tap to Building not installed, This will be required to be installed and open for inspection at the All Rough inspection. | |||
| SEWER TIE IN | 03/30/2026 | APPROVED | JSTEWART |
| Note: Live Virtual Inspection. NOTE: Main water line from utility tap to Building installed. Inspector Notes from Inspection 2060 Main water line from utility tap to Building not installed, This will be required to be installed and open for inspection at the All Rough inspection. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 03/30/2026 | APPROVED | JSTEWART |
| Note: 3/27/2026 - PREVIOUS INSPECTION NOTES 1. No approved structural plans onsite. 2. Please reschedule when Inspector is able to complete inspection without trades working over head, floor is clear of debri. | |||
| ROOF VALLEY & METAL | 03/30/2026 | APPROVED | JSTEWART |
| Note: 3/27/2026 - PREVIOUS INSPECTION NOTES Roof sheathing and ties requires approval prior. | |||
| ROOF VALLEY & METAL | 03/27/2026 | Disapproved - NO FEE | JSTEWART |
| Note: Roof sheathing and ties requires approval prior. | |||
| WALL SHEATHING | 03/27/2026 | APPROVED | JSTEWART |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 03/27/2026 | Disapproved - NO FEE | JSTEWART |
| Note: 1. No approved structural plans onsite. 2. Please reschedule when Inspector is able to complete inspection without trades working over head, floor is clear of debri. | |||
| MONOLITHIC SLAB | 03/12/2026 | APPROVED | JSTEWART |
| Note: 3/11/2026 - PREVIOUS INSPECTION NOTES 1. Rebar at garage curb step up needs positioned for clearence from form board min of 1 1/2". 2. Back right corner footing reinforcment lap splice needs to be tied off to adjoining reinforcement. FBC R404.1.3.3.7.5 3. Vapor barrier needs to be cut out for the required 20ft of the Ufer ground (concrete encased electrode), requires direct contact with earth. NEC 250.52(A)(3) | |||
| MONOLITHIC SLAB | 03/11/2026 | Disapproved - NO FEE | JSTEWART |
| Note: 1. Rebar at garage curb step up needs positioned for clearence from form board min of 1 1/2". 2. Back right corner footing reinforcment lap splice needs to be tied off to adjoining reinforcement. FBC R404.1.3.3.7.5 3. Vapor barrier needs to be cut out for the required 20ft of the Ufer ground (concrete encased electrode), requires direct contact with earth. NEC 250.52(A)(3) | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 03/09/2026 | APPROVED - AS NOTED | JSTEWART |
| Note: Main water line from utility tap to Building not installed, This will be required to be installed and open for inspection at the All Rough inspection. | |||
| WATER METER INSTALLATION REQUEST | 03/09/2026 | APPROVED | ISANDERSON |
| FORMBOARD SURVEY (OFFICE USE ONLY) | 03/06/2026 | APPROVED | RRICKS |
Review History
| Department | Status | Date In | Date Out |
| BADMIN | INFORMATION | 05/20/2026 | 05/20/2026 |
| Note: Marked INFORMATION By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM FORMBOARD SURVEY CAN NOT BE ACCEPTED | |||
| SW1 | COMPLETE | 03/06/2026 | 03/06/2026 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 03/06/2026 | 03/06/2026 |
| Note: Released By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 02/24/2026 | 02/24/2026 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| URB | COMPLETE | 02/24/2026 | 02/25/2026 |
| Note: Released By: JOHN BEAUDET - (386)986-2456 - JBEAUDET@PALMCOASTGOV.COM | |||
| URB | HOLD | 02/23/2026 | 02/24/2026 |
| Note: Held By: JOHN BEAUDET - (386)986-2456 - JBEAUDET@PALMCOASTGOV.COM Need to show the Live oak tree QV on the plan. | |||
| ZON | HOLD | 02/23/2026 | 02/23/2026 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Only one tree shown update plan accordingly | |||
| BLD | COMPLETE | 02/12/2026 | 02/19/2026 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 02/12/2026 | 02/23/2026 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 02/12/2026 | 02/18/2026 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 02/12/2026 | 02/12/2026 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| GAS | COMPLETE | 02/12/2026 | 02/17/2026 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 02/12/2026 | 02/19/2026 |
| Note: Released By: IVAN SANDERSON - - | |||
| MECH | COMPLETE | 02/12/2026 | 02/17/2026 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 02/12/2026 | 02/17/2026 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ZON | HOLD | 02/12/2026 | 02/18/2026 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Landscap plan: Residential homes shall provide a foundation plantings consisting of 16 shrubs on interior lots. Eight shrubs shall be planted in front of home and four shrubs planted on each side of the home. The corners of the home shall be wrapped with shrubbery or have an understory tree planted there. *All of these required shrubs shall be planted between two and one half and eight feet of the homes foundation.* *Six Shrubs shall be planted on each side of the home facing the street Please provide the proposed sod being laid down. Also if Irrigation will be needed. | |||
| URB | HOLD | 02/12/2026 | 02/13/2026 |
| Note: Held By: JOHN BEAUDET - (386)986-2456 - JBEAUDET@PALMCOASTGOV.COM 2/13/26 (JB) NEED TO ADD 2 SHRUBS TO THE LEFT SIDE. THE CODE REQUIRES A MINIMUMM OF 4 ON EACH SIDE OF THE HOMES FOUNDATION. NEED TO INDICATE THE TYPE OF SOD BEING INSTALLED. IF USING ST AUGUSTINE OR ZOYSIA TYPE YOU WILL NEED TO ALSO INDICATE INSTALLING A IRRIGATION SYSTEM WITH 100% COVERAGE. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| RSI REINSPECTION 1 | ¤35.00 | 06/01/2026 |
| RSI ROW FINAL INSPECTION | ¤16.25 | 02/27/2026 |
| SCHOOL BOARD IMPACT FEE RES | ¤5,450.00 | 02/27/2026 |
| SURCHARGE FS 533.721 | ¤11.74 | 02/27/2026 |
| SURCHARGE - FS 468.631 | ¤17.61 | 02/27/2026 |
| TRANSP RES IMPACT FEE 10-25 | ¤6,175.26 | 02/27/2026 |
| WASTEWATER PERM INSPECTION | ¤80.00 | 02/27/2026 |
| WASTEWATER PERM REVIEW | ¤25.00 | 02/27/2026 |
| SEWER CAPITAL FACILITY | ¤3,628.86 | 02/27/2026 |
| WATER CAPITAL FACILITY FEE | ¤3,091.14 | 02/27/2026 |
| WATER PERMIT REVIEW | ¤25.00 | 02/27/2026 |
| SITE PLAN 30 | ¤30.00 | 02/27/2026 |
| WATER-METER | ¤874.47 | 02/27/2026 |
| WATER- TURN ON | ¤50.00 | 02/27/2026 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 02/27/2026 |
| INSPECTION - RESIDENTIAL | ¤891.00 | 02/27/2026 |
| PLAN REVIEW - RESIDENTIAL | ¤252.72 | 02/27/2026 |
| FC IMPACT FEE EMS | ¤62.00 | 02/27/2026 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 02/27/2026 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 02/27/2026 |
| FIRE RES IMPACT FEE 10-25 | ¤942.00 | 02/27/2026 |
| WATER METER W/OUT TAP | ¤965.03 | 02/27/2026 |
| PARKS IMPACT FEE 10-25 | ¤3,164.00 | 02/27/2026 |
| RECLAIM WATER PERMIT INSPECTIO | ¤40.00 | 02/27/2026 |
| RSI DRIVEWAY AFTER POUR | ¤16.25 | 02/27/2026 |
| RSE DRIVE PRE POUR INSPECTION | ¤32.50 | 02/27/2026 |
| RSI FIELD SURVEY INSPECTION | ¤48.75 | 02/27/2026 |
| RSI FORMBOARD REVIEW | ¤16.25 | 02/27/2026 |
| RSI PLAN REVIEW NEW | ¤48.75 | 02/27/2026 |
| RSI FNL SURVEY/GRADING CERT | ¤48.75 | 02/27/2026 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤26,554.33 |