Permit #2026020563
Permit Details
Status: APPLY
| Parcel Id: 07-11-31-7063-RP0J2-0000 |
| Block: RP J2 |
| Subdivision: 2375 - DCI-BELLE TERRE |
| Job Phone: 501-681-0560 |
| Location Address: 1091 BELLE TERRE BLVD |
| Type: BC - BUILDING COMMERCIAL |
| NOC: NO DOCUMENTATION |
| Applicant name: RYAN A BRADBURY |
| Owner: JRB-PC LLC |
|
Address 3948 3RD STREET SOUTH JACKSONVILLE BEACH, FL 32250 |
|
Address SUITE 35 JACKSONVILLE BEACH, FL 32250 |
| Lot: 0000 |
| Contracted Stated Job Value: ¤450,000.00 |
| Job Description: COMMERCIAL BUILDING 7 BREW |
| Type: CN |
Contractor
PRECISION CONSTRUCTION
| Status | Location Address | State License Number | Phone |
| ACTIVE |
PO BOX 662 GREENBRIER, AR 72058 |
CBC1266824 (Exp: 08/31/2026) | 501-681-0560 |
Inspection History
| Type | Request Date | Result | Inspector |
| FORMBOARD SURVEY | |||
| GEO TECH CERTIFICATION | |||
| PLUMBING 1ST ROUGH | |||
| PLUMBING 2ND ROUGH | |||
| GRAVITY SEWER | |||
| BLD - SEWER TIE IN | |||
| WATER SERVICE | |||
| PLUMBING FINAL | |||
| HVAC ROUGH | |||
| HVAC FINAL | |||
| ELECTRIC 1ST ROUGH | |||
| ELECTRIC 2ND ROUGH | |||
| ELECTRIC - EARLY POWER | |||
| ELECTRIC FINAL | |||
| MONOLITHIC SLAB | |||
| FOOTER | |||
| LINTEL | |||
| FRAMING | |||
| ROOF SHEATHING / BRACE / TIE DOWN | |||
| ABOVE CEILING | |||
| INSULATION | |||
| DRYWALL NAILING | |||
| STOREFRONT | |||
| BUILDING FINAL | |||
| FIRE FINAL | |||
| EXTERIOR ARCHITECTURAL FEATURES | |||
| U - UTILITY COMMERCIAL FINAL |
Review History
| Department | Status | Date In | Date Out |
| MECH | PENDING | 06/04/2026 | |
| BLD | COMPLETE | 06/04/2026 | 06/11/2026 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| UD2 | PENDING | 06/04/2026 | |
| ELEC | COMPLETE | 06/04/2026 | 06/11/2026 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| DSD | COMPLETE | 06/04/2026 | 06/04/2026 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| FI1 | COMPLETE | 06/04/2026 | 06/11/2026 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 06/04/2026 | 06/11/2026 |
| UD2 | HOLD | 04/24/2026 | 05/04/2026 |
| Note: Held By: DAN LEMONCELLO - - 1) On attachment page M1.1, dated 4/24/2026, must add 2nd page of Palm Coast City Standard details page for plumbing contractor. Plumbing contractor must have all the grease interceptor information before they apply for the separate permit with the correct details. 2) Contact Utility Wastewater Pretreatment Inspector Dan Lemoncello if you need the other page of details. Email @ llemoncello@palmcoastgov.com | |||
| MECH | HOLD | 04/24/2026 | 05/04/2026 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM COMMENTS BELOW PER THE 2023 FLORIDA BUILDING CODE-BUILDING (FBCB), FLORIDA BUILDING CODE- MECHANICAL (FBCM), FLORIDA BUILDING CODE-ENERGY CONSERVATION (FBCEC), FLORIDA STATUTES (FS), FLORIDA ADMINISTRATIVE CODE (FAC) AND AUTHORITY HAVING JURISDICTION (AHJ). PLAN RE-SUBMITTAL SHALL BE ACCOMPANIED BY A RESPONSE LETTER SIGNED AND SEALED BY THE APPROPRIATE DESIGN PROFESSIONAL(S). ALL PLAN REVISIONS SHALL BE CLOUDED APPROPRIATELY. NO RESPONSE LETTER SUBMITTED REPEAT COMMENT: 1. Provide Heatload Calculation per C403.2.1 FBC Energy Conservation (NOT SUBMITTED) REPEAT COMMENT: 2. Provide manufacturers specs on Ice machine equipment. FBC Energy Conservation (NOT SUBMITTED) REPEAT COMMENT: 3. Provide details for the optional minisplit. FBC 107.2.1(NOT SUBMITTED) 4. OK REPEAT COMMENT: 5. Plan page M3.1 under General Mechanical Notes (#5) rermove referece to IBC 2018. Needs to be 2023 FBC. (NOT SUBMITTED) | |||
| PLUM | COMPLETE | 04/24/2026 | 05/04/2026 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | HOLD | 04/24/2026 | 05/04/2026 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM COMMENTS BELOW PER THE 2023 FLORIDA BUILDING CODE-BUILDING (FBCB), FLORIDA BUILDING CODE-ACCESSIBILITY (FBCA), FLORIDA BUILDING CODE-PLUMBING (FBCP), FLORIDA STATUTES (FS), FLORIDA ADMINISTRATIVE CODE (FAC) AND AUTHORITY HAVING JURISDICTION (AHJ). PLAN RE-SUBMITTAL SHALL BE ACCOMPANIED BY A RESPONSE LETTER SIGNED AND SEALED BY THE APPROPRIATE DESIGN PROFESSIONAL(S). ALL PLAN REVISIONS SHALL BE CLOUDED APPROPRIATELY. 1. OK REPEAT COMMENT: 2. All architectural plan sheets need to have a digital verifiable signature F.S. 471.025 (ARCHITECTURAL PAGES NEED TO BE DIGITALLY SIGNED AND SEALED. THE MODULAR PLANS ARE GOOD) 3. OK 4. OK REPEAT COMMENT: 5. Plan page A01 in code analysis remove reference to IBC. Needs to say FBC( A01 IS IN THE ARCHTECTURAL PAGES) 6. OK | |||
| DSD | COMPLETE | 03/31/2026 | 04/01/2026 |
| Note: Released By: DAMARIS RAMIREZ - (386)986-3750 - DRAMIREZ@PALMCOASTGOV.COM | |||
| UD2 | HOLD | 03/31/2026 | 04/01/2026 |
| Note: Held By: DAN LEMONCELLO - - 1)A separate permit is required for all grease interceptors. 2)The separate permit must have our City standard details sheets, a details sheet from selected manufacturer and sizing ordered. 3) email Utility Wastewater Pretreatment Inspector, Dan Lemoncello if any questions @ llemoncello@palmcoastgov.com or call (386)286-2011. | |||
| BLD | HOLD | 03/31/2026 | 04/12/2026 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM COMMENTS BELOW PER THE 2023 FLORIDA BUILDING CODE-BUILDING (FBCB), FLORIDA BUILDING CODE-ACCESSIBILITY (FBCA), FLORIDA BUILDING CODE-PLUMBING (FBCP), FLORIDA STATUTES (FS), FLORIDA ADMINISTRATIVE CODE (FAC) AND AUTHORITY HAVING JURISDICTION (AHJ). PLAN RE-SUBMITTAL SHALL BE ACCOMPANIED BY A RESPONSE LETTER SIGNED AND SEALED BY THE APPROPRIATE DESIGN PROFESSIONAL(S). ALL PLAN REVISIONS SHALL BE CLOUDED APPROPRIATELY. 1. Provide all state approved plans for modular building , including plan index from modular building plans. F.S. 553.37 (1) (a) 2. All architectural plan sheets need to have a digital verifiable signature F.S. 471.025 3. Provide shop drawings for premanufactured canopy, roof guards etc.. or list as deferred submittals 107.2.1 4. Provide live loads and attachment details for guards. 1015.2, 1607.1, 1607.9 5. Plan page A01 in code analysis remove reference to IBC. Needs to say FBC 6. Provide details in ladder for mechanical access room, live loads etc..107.2.1/ 1607.1, Table 1607.1 Further comments may arise after review of manufacturerd building plans | |||
| FI1 | COMPLETE | 03/31/2026 | 04/13/2026 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | HOLD | 03/31/2026 | 04/12/2026 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM COMMENTS BELOW PER THE 2023 FLORIDA BUILDING CODE-BUILDING (FBCB), FLORIDA BUILDING CODE- MECHANICAL (FBCM), FLORIDA BUILDING CODE-ENERGY CONSERVATION (FBCEC), FLORIDA STATUTES (FS), FLORIDA ADMINISTRATIVE CODE (FAC) AND AUTHORITY HAVING JURISDICTION (AHJ). PLAN RE-SUBMITTAL SHALL BE ACCOMPANIED BY A RESPONSE LETTER SIGNED AND SEALED BY THE APPROPRIATE DESIGN PROFESSIONAL(S). ALL PLAN REVISIONS SHALL BE CLOUDED APPROPRIATELY. 1. Provide Heatload Calculation per C403.2.1 FBC Energy Conservation 2. Provide manufacturers specs on Ice machine equipment. FBC Energy Conservation 3. Provide details for the optional minisplit. FBC 107.2.1 4. Provide note on plans saying condensate from RTU's to route to storm drains per 307.2.1 FBC Mechanical 5. Plan page M3.1 under General Mechanical Notes (#5) rermove referece to IBC 2018. Needs to be 2023 FBC. | |||
| PLUM | HOLD | 03/31/2026 | 04/12/2026 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM COMMENTS BELOW PER THE 2023 FLORIDA BUILDING CODE-BUILDING (FBCB), FLORIDA BUILDING CODE-PLUMBING (FBCP), FLORIDA BUILDING CODE-ACCESSIBILITY (FBCA), FLORIDA STATUTES (F.S.), FLORIDA ADMINISTRATIVE CODE (F.A.C.) AND AUTHORITY HAVING JURISDICTION (A.H.J.). PLAN RE-SUBMITTAL SHALL BE ACCOMPANIED BY A RESPONSE LETTER SIGNED AND SEALED BY THE APPROPRIATE DESIGN PROFESSIONAL(S). ALL PLAN REVISIONS SHALL BE CLOUDED APPROPRIATELY. 1. Add to plumging fixture and equipment schedule. Show backflow preventer required at hose-bibbs, janitor sink, ice-maker, Espresso machines and any other water utilizing appliance connected to the water system including any not shown in the plans. Section 608. Table 608.1. 2. Provide note to indicate all backflow devices are subject to testing by an independent, third party, Florida licensed backflow testing agency and each backflow device will be tested and provided with an approved testing tag at time of installation. 312.10.2 | |||
| GAS | CANCEL | 03/31/2026 | 04/08/2026 |
| ELEC | COMPLETE | 03/31/2026 | 04/13/2026 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| UD1 | COMPLETE | 03/31/2026 | 04/15/2026 |
| Note: Released By: GREG DEGLER - (386)986-2384 - GDEGLER@PALMCOASTGOV.COM | |||
| ARCHR | COMPLETE | 02/17/2026 | 03/03/2026 |
| Note: Released By: RICHARD PICATAGI - (386)986-3760 - RPICATAGI@PALMCOASTGOV.COM | |||
| BLD | HOLD | 02/17/2026 | 02/18/2026 |
| Note: Held By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM plans cannot be submitted in a group. Must be in single format and file names correct | |||
| DSD | HOLD | 02/17/2026 | 02/17/2026 |
| Note: Held By: DAMARIS RAMIREZ - (386)986-3750 - DRAMIREZ@PALMCOASTGOV.COM 1. Upload a stamp approved elevation plans. 2. Upload stamp approved site plan. 3. All the documents with the address of 100 Belle Terre Blvd will need to be updated as this is the incorrect building address. The address for this building is 1091 Belle Terre Blvd. | |||
| ELEC | HOLD | 02/17/2026 | 02/18/2026 |
| Note: Held By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM plans cannot be submitted in a group. Must be in single format and file names correct | |||
| FI1 | HOLD | 02/17/2026 | 02/18/2026 |
| Note: Held By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM plans cannot be submitted in a group. Must be in single format and file names correct | |||
| GAS | HOLD | 02/17/2026 | 02/18/2026 |
| Note: Held By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM plans cannot be submitted in a group. Must be in single format and file names correct | |||
| MECH | HOLD | 02/17/2026 | 02/18/2026 |
| Note: Held By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM plans cannot be submitted in a group. Must be in single format and file names correct | |||
| PLUM | HOLD | 02/17/2026 | 02/18/2026 |
| Note: Held By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM plans cannot be submitted in a group. Must be in single format and file names correct | |||
| UD1 | HOLD | 02/17/2026 | 02/27/2026 |
| Note: Held By: GREG DEGLER - (386)986-2384 - GDEGLER@PALMCOASTGOV.COM See comments from Development Services-Damaris Ramirez | |||
| UD2 | HOLD | 02/17/2026 | 02/17/2026 |
| Note: Held By: DAN LEMONCELLO - - 1) Contact Utility Wastewater Prtreatment Inspector Dan Lemoncello @ llemoncello@palmcoastgov.com for copy of City standard grease interceptor. 2) Submit peak flow rates for all sinks/drains to calculate interceptor capacity. 3) Must apply for separate permit for grease interceptor approval/pre-delivery and installation and flow/dye test. |