I want to search for...

Permit #2026020645

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7034-00230-0080
Block: 00230
Subdivision: 2165 - SECTION 34-EASTHAMPTON
Job Phone: 386-387-1722
Location Address: 45 EAGLE HARBOR TRL
Type: DR - DRIVEWAY
Issue Date: 02/23/2026
NOC: Unknown
Applicant name: JONATHAN E SCHOFIELD
Owner: COTLER JERROLD R LIFE ESTATE

Address

45 EAGLE TRAIL

PALM COAST, FL 32164

Lot: 0080
Contracted Stated Job Value: ¤2,400.00
Job Description: CONCRETE circle drive 16'x52'. 24' long culvert
Type: CN

Contractor

STAY HARD CONCRETE PAVERS LLC
Status Location Address Phone
ACTIVE

123 WESTCHESTER LANE

PALM COAST, FL 32164

386-387-1722

Inspection History

Type Request Date Result Inspector
ROW - FINAL APRON (AFTER POUR) 06/01/2026 APPROVED FSLADISH
Note: 6/1/26 AT THE TIME OF THE INSPECTION ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
ROW - FINAL INSPECTION 06/01/2026 APPROVED FSLADISH
Note: 6/1/26 AT THE TIME OF THE INSPECTION ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
U -UTILITY RESIDENTIAL FINAL 06/01/2026 APPROVED BVEIGA
ROW- PRE-APRON (PRE-POUR) 02/25/2026 APPROVED FSLADISH
Note: 2/25/26 PIPE INVERT IS GOOD AT THIS INSPECTION. BUILDER REFER TO CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR BEFORE POURING. . IF FIBERGLASS OPTION IS USED, BUILDER REQUIRED TO USE 3000 PSI CONCRETE AT THE TIME OF THE INSPECTION READY TO POUR,IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK SITE FOR ANY STANDING WATER. ALSO VERIFY PIPE ELEVATION HAS NOT CHANGED. NO EXPANSION JOINTS ALLOWED, AT THE TIME OF THIS INSPECTION ALL MINIMUM COPC REQUIREMENTS ARE MET. BUILDER TO BE HELD RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR.

Review History

Department Status Date In Date Out
SWALE COMPLETE 02/19/2026 02/23/2026
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
ENGIN1 COMPLETE 02/18/2026 02/19/2026
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
RSI COMPLETE 02/18/2026 02/20/2026
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
UTL COMPLETE 02/18/2026 02/19/2026
Note: Released By: LARRY FITZGERALD - (386)286-2041 - LFITZGERALD@PALMCOASTGOV.COM
ZON COMPLETE 02/18/2026 02/19/2026
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADMINISTRATIVE RESIDENTIAL ¤30.00 02/23/2026
RSI DRIVEWAY AFTER POUR ¤16.25 02/23/2026
RSE DRIVE PRE POUR INSPECTION ¤32.50 02/23/2026
RSI ROW FINAL INSPECTION ¤16.25 02/23/2026
RSI SITE PLAN REVIEW ¤16.25 02/23/2026
SW ENG RES REVIEW 240 ¤240.00 02/23/2026
SITE PLAN 15 ¤15.00 02/23/2026
Fees Total Due: ¤0.00 Total Paid: ¤366.25