I want to search for...
Permit #2026021012
Permit Details
Status: INSPECT
| Parcel Id: 07-11-31-7023-00580-0130 |
| CONDITIONED SPACE: 1849 sqft |
| GARAGE: 480 sqft |
| OPENED PORCH (WITH ROOF) : 80 sqft |
| OPENED PORCH (WITH ROOF) : 168 sqft |
| Total Square Footage: 2577 sqft |
| Block: 00580 |
| Subdivision: 2191 - SECTION 23-WYNNFIELD |
| Job Phone: 631-929-5500 |
| Location Address: 50 WHEELING LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 03/12/2026 |
| NOC: RECORDED |
| Applicant name: NICHOLAS JOHN ZOUMAS |
| Owner: ASZ HOMES LLC |
|
Address 45 NEW YORK 25A SHOREHAM, NY 11786 |
| Lot: 0130 |
| Contracted Stated Job Value: ¤170,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
JNS CONTRACTING FLORIDA, LLC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
256 ROUTE 25A WADING RIVER, NY 11792 |
CGC1527793 (Exp: 08/31/2026) | 631-929-5500 |
Sub Contractors
NICHOLAS JOHN ZOUMAS
| Status | Location Address | State License Number | Phone |
| ACTIVE |
256 ROUTE 25A WADING RIVER, NY 11792 |
CGC1527793 (Exp: 08/31/2026) | 631-929-5500 |
JASON LEE JAMES
| Status | Location Address | State License Number | Phone |
| ACTIVE |
217 N WESTMONTE DR SUITE 1007 ALTAMONTE SPRINGS, FL 32714 |
CAC1820196 (Exp: 08/31/2026) | 407-404-4000 |
JASON LEE JAMES
| Status | Location Address | State License Number | Phone |
| ACTIVE |
217 N WESTMONTE DR SUITE 1007 ALTAMONTE SPRINGS, FL 32714 |
CFC1430061 (Exp: 08/31/2026) | 407-404-4000 |
ANTHONY OKEITH FENNELL
| Status | Location Address | State License Number | Phone |
| ACTIVE |
217 N. WESTMONTE DR, SUITE 1007 ALTAMONTE SPRINGS, FL 32714 |
EC13011194 (Exp: 08/31/2026) | 407-404-4000 |
Inspection History
| Type | Request Date | Result | Inspector |
| DRYWALL NAILING | 05/26/2026 | APPROVED | HCAMACHO |
| PEP TANK INSTALLATION REQUEST | 05/26/2026 | APPROVED | ISANDERSON |
| U-CROSS CONNECTION | 05/26/2026 | APPROVED - AS NOTED | BHAINES |
| Note: No CC, No IRR | |||
| INSULATION | 05/20/2026 | APPROVED | HCAMACHO |
| Note: Inspector Notes from Inspection 2420 1. Receptacle on the ouside Service Panel does not have a breaker installed and is not GFCI.NEC 210.8, NEC 240.4, NEC210.20 2. Receptacle on the front of the island needs to be removed if installing counter overhang more then 6".NEC 210.52(C)(3) "Plans call for POP UP" *Will check at Insulation* | |||
| ROW - DRAINAGE | 05/20/2026 | APPROVED - AS NOTED | PFLANAGAN |
| Note: Please regrade swale properly passing as noted that this will be corrected ------------------------------------------------------------------- 5/13/2026 - PREVIOUS INSPECTION NOTES Need to do the following 1) Need to remove all dirt from the street 2) Need to remove all concrete slurry from site. 3) Need to pick up all trash and constrcution debris from lot and place it in a dumpster. 4) Need to remove porter jon out of swale. 5) Need to regrade swale so water can flow correctly. You will have 7day to correct all issues. | |||
| ELECTRIC-TUG | 05/20/2026 | APPROVED | HCAMACHO |
| Note: 5/18/2026 - PREVIOUS INSPECTION NOTES *Nothing was fixed from the previous Inspection* 5/13/2026 - PREVIOUS INSPECTION NOTES 1. Missing the the breaker for the service Receptacle & needs to be GFCI. NEC 210.8, NEC 210.20(A), NEC240.4 2. Receptacle is not secured.NEC314.23, NEC406.5 | |||
| ELECTRIC-TUG | 05/18/2026 | Disapproved -FEE REQUIRED | HCAMACHO |
| Note: *Nothing was fixed from the previous Inspection* 5/13/2026 - PREVIOUS INSPECTION NOTES 1. Missing the the breaker for the service Receptacle & needs to be GFCI. NEC 210.8, NEC 210.20(A), NEC240.4 2. Receptacle is not secured.NEC314.23, NEC406.5 | |||
| ALL ROUGH | 05/15/2026 | APPROVED - AS NOTED | HCAMACHO |
| Note: 1. Receptacle on the ouside Service Panel does not have a breaker installed and is not GFCI.NEC 210.8, NEC 240.4, NEC210.20 2. Receptacle on the front of the island needs to be removed if installing counter overhang more then 6".NEC 210.52(C)(3) "Plans call for POP UP" *Will check at Insulation* | |||
| WALL SHEATHING | 05/14/2026 | APPROVED | HCAMACHO |
| Note: 5/8/2026 - PREVIOUS INSPECTION NOTES 1. No Approved plans onsite. I asked the A/C guys working if they had them and they did not. FBC [A]107.3.1 NEEDS APPROVED PLANS ON SITE Inspector Notes from Inspection 2340 FBC 3302.2 NEEDS DUMPSTER | |||
| ELECTRIC-TUG | 05/13/2026 | Disapproved - NO FEE | HCAMACHO |
| Note: 1. Missing the the breaker for the service Receptacle & needs to be GFCI. NEC 210.8, NEC 210.20(A), NEC240.4 2. Receptacle is not secured.NEC314.23, NEC406.5 | |||
| ROW - DRAINAGE | 05/13/2026 | Disapproved - NO FEE | PFLANAGAN |
| Note: Need to do the following 1) Need to remove all dirt from the street 2) Need to remove all concrete slurry from site. 3) Need to pick up all trash and constrcution debris from lot and place it in a dumpster. 4) Need to remove porter jon out of swale. 5) Need to regrade swale so water can flow correctly. You will have 7day to correct all issues. | |||
| LATH/BRICK/ WATER BARRIER | 05/12/2026 | APPROVED | HCAMACHO |
| Note: Inspector Notes from Inspection 2460 1. Small Bearing wall in garage is missing bolts. Marked, see plans. 2. Trusses B6 on the same wall and girder A17 truss is missing HTS20. Plans Call for (2). Detail F1 5/8/2026 - PREVIOUS INSPECTION NOTES 1. No Approved plans onsite. I asked the A/C guys working if they had them and they did not. FBC [A]107.3.1 NEEDS APPROVED PLANS ON SITE Inspector Notes from Inspection 2340 FBC 3302.2 NEEDS DUMPSTER | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 05/11/2026 | APPROVED - AS NOTED | HCAMACHO |
| Note: 1. Small Bearing wall in garage is missing bolts. Marked, see plans. 2. Trusses B6 on the same wall and girder A17 truss is missing HTS20. Plans Call for (2). Detail F1 5/8/2026 - PREVIOUS INSPECTION NOTES 1. No Approved plans onsite. I asked the A/C guys working if they had them and they did not. FBC [A]107.3.1 NEEDS APPROVED PLANS ON SITE Inspector Notes from Inspection 2340 FBC 3302.2 NEEDS DUMPSTER | |||
| ROOF VALLEY & METAL | 05/08/2026 | APPROVED | HCAMACHO |
| Note: Inspector Notes from Inspection 2340 FBC 3302.2 NEEDS DUMPSTER | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 05/08/2026 | Disapproved - NO FEE | HCAMACHO |
| Note: 1. No Approved plans onsite. I asked the A/C guys working if they had them and they did not. FBC [A]107.3.1 NEEDS APPROVED PLANS ON SITE Inspector Notes from Inspection 2340 FBC 3302.2 NEEDS DUMPSTER | |||
| WALL SHEATHING | 05/08/2026 | Disapproved - NO FEE | HCAMACHO |
| Note: 1. No Approved plans onsite. I asked the A/C guys working if they had them and they did not. FBC [A]107.3.1 NEEDS APPROVED PLANS ON SITE Inspector Notes from Inspection 2340 FBC 3302.2 NEEDS DUMPSTER | |||
| TIE BEAM / LINTEL | 04/28/2026 | APPROVED - AS NOTED | HCAMACHO |
| Note: FBC 3302.2 NEEDS DUMPSTER | |||
| MONOLITHIC SLAB | 04/06/2026 | APPROVED | HCAMACHO |
| PLUMBING 1ST ROUGH UNDERGROUND | 03/31/2026 | APPROVED | HCAMACHO |
| FORMBOARD SURVEY (OFFICE USE ONLY) | 03/30/2026 | APPROVED | RRICKS |
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | 03/25/2026 | APPROVED | PKNAPIK |
| WATER METER INSTALLATION REQUEST | 03/17/2026 | APPROVED | ISANDERSON |
| Note: 3/16/2026 8:52:07 AM- PREVIOUS INSPECTION NOTES Lot not cleared yet. | |||
| WATER METER INSTALLATION REQUEST | 03/13/2026 | Disapproved - NO FEE | ISANDERSON |
| Note: Lot not cleared yet. | |||
| ROW - FINAL INSPECTION | |||
| U -UTILITY RESIDENTIAL FINAL | |||
| BLD - BUILDING FINAL | |||
| ROW- PRE-APRON (PRE-POUR) | |||
| ROW - FINAL APRON (AFTER POUR) | |||
| GRAVITY SEWER TEST | |||
| SEWER TIE IN | |||
| ELECTRIC - EARLY POWER |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 05/12/2026 | 05/13/2026 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 05/08/2026 | 05/11/2026 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM Fees already paid on this permit and meter has already been installed. No additional fees owed at this time. | |||
| SW1 | COMPLETE | 03/30/2026 | 03/30/2026 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 03/30/2026 | 03/30/2026 |
| Note: Released By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 03/25/2026 | 03/25/2026 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 02/27/2026 | 03/11/2026 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 02/26/2026 | 03/05/2026 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 02/26/2026 | 02/27/2026 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 02/26/2026 | 03/04/2026 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 02/26/2026 | 02/27/2026 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 02/26/2026 | 02/27/2026 |
| LOCATE | COMPLETE | 02/26/2026 | 02/27/2026 |
| Note: Released By: IVAN SANDERSON - - | |||
| MECH | COMPLETE | 02/26/2026 | 03/02/2026 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 02/26/2026 | 03/04/2026 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 02/26/2026 | 03/02/2026 |
| Note: Released By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| RSI ROW FINAL INSPECTION | ¤16.25 | 03/12/2026 |
| SCHOOL BOARD IMPACT FEE RES | ¤5,450.00 | 03/12/2026 |
| WASTEWATER MAIN EXTENSION IMPA | ¤2,385.00 | 03/12/2026 |
| SURCHARGE FS 533.721 | ¤13.26 | 03/12/2026 |
| SURCHARGE - FS 468.631 | ¤19.88 | 03/12/2026 |
| SW ENG RES REVIEW 240 | ¤240.00 | 03/12/2026 |
| WATER METER W/ TAP | ¤2,326.93 | 03/12/2026 |
| TRANSP RES IMPACT FEE 10-25 | ¤6,970.73 | 03/12/2026 |
| SEWER CREDIT | (¤1,147.00) | 03/12/2026 |
| WASTEWATER PERM INSPECTION | ¤80.00 | 03/12/2026 |
| WASTEWATER PERM REVIEW | ¤25.00 | 03/12/2026 |
| SEWER CAPITAL FACILITY | ¤4,415.00 | 03/12/2026 |
| WATER CAPITAL FACILITY FEE | ¤3,790.49 | 03/12/2026 |
| WATER PERMIT REVIEW | ¤25.00 | 03/12/2026 |
| WATER MAIN EXTENSION IMPACT | ¤917.27 | 03/12/2026 |
| SITE PLAN 30 | ¤30.00 | 03/12/2026 |
| FC IMPACT FEE EMS | ¤62.00 | 03/12/2026 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 03/12/2026 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 03/12/2026 |
| FIRE RES IMPACT FEE 10-25 | ¤942.00 | 03/12/2026 |
| PEP TANK INSTALL | ¤756.74 | 03/12/2026 |
| PARKS IMPACT FEE 10-25 | ¤3,164.00 | 03/12/2026 |
| RSI DRIVEWAY AFTER POUR | ¤16.25 | 03/12/2026 |
| RSE DRIVE PRE POUR INSPECTION | ¤32.50 | 03/12/2026 |
| RSI FIELD SURVEY INSPECTION | ¤48.75 | 03/12/2026 |
| RSI FORMBOARD REVIEW | ¤16.25 | 03/12/2026 |
| RSI PLAN REVIEW NEW | ¤48.75 | 03/12/2026 |
| RSI FNL SURVEY/GRADING CERT | ¤48.75 | 03/12/2026 |
| WATER- TURN ON | ¤50.00 | 03/12/2026 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 03/12/2026 |
| INSPECTION - RESIDENTIAL | ¤1,009.25 | 03/12/2026 |
| PLAN REVIEW - RESIDENTIAL | ¤286.26 | 03/12/2026 |
| PLAN REVIEW - REVISION | ¤32.50 | |
| REINSPECTION RESIDENTIAL | ¤40.00 | |
| RSI REINSPECTION 1 | ¤35.00 | |
| RSI REINSPECTION 1 | ¤35.00 | |
| Fees | Total Due: ¤142.50 | Total Paid: ¤32,555.31 |