I want to search for...
Permit #2026021094
Permit Details
Status: INSPECT
| Parcel Id: 07-11-31-7031-00170-0090 |
| CONDITIONED SPACE: 2400 sqft |
| GARAGE: 566 sqft |
| OPENED PORCH (WITH ROOF) : 350 sqft |
| Total Square Footage: 3316 sqft |
| Block: 00170 |
| Subdivision: 2166 - SECTION 31-ROYAL PALMS |
| Job Phone: 386-283-2035 |
| Location Address: 7 RIDDLE PL |
| Type: DU - DUPLEX |
| Issue Date: 03/31/2026 |
| NOC: RECORDED |
| Applicant name: OLEG BELINSKIY |
| Owner: CORNERSTONE REALTY AND TRUST LLC |
|
Address 2021 E CLOVELLY LANE SAINT AUGUSTINE, FL 32092 |
| Lot: 0090 |
| Contracted Stated Job Value: ¤350,000.00 |
| Job Description: DUPLEX |
| Type: CN |
Contractor
FLORIDAS BEST BUILDERS INC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
19 PINE CIRCLE DRIVE PALM COAST, FL 32164 |
CBC1264760 (Exp: 08/31/2026) | 386-283-2035 |
Sub Contractors
OLEG BELINSKIY
| Status | Location Address | State License Number | Phone |
| ACTIVE |
19 PINE CIRCLE DRIVE19 PALM COAST, FL 32167 |
CCC1325974 (Exp: 08/31/2026) | 386-263-7906 |
TIMUR ISPARYAN
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
3665 SPRINK PARK ROAD JACKSONVILLE , FL 32207 |
CMC1249968 (Exp: 08/31/2026) | 904-245-1818 | 904-337-1910 |
JUAN CARLOS GONZALEZ
| Status | Location Address | State License Number |
| ACTIVE |
1328 COUNTY ROAD 308 CRESCENT CITY, FL 32112 |
RF11067806 (Exp: 08/31/2027) |
SERGEY A VORONIN
| Status | Location Address | State License Number | Phone |
| ACTIVE |
7631 SEVERN JACKSONVILLE, FL 32224 |
EC13011326 (Exp: 08/31/2026) | 360-798-2819 |
Inspection History
| Type | Request Date | Result | Inspector |
| FIREWALL DRYWALL NAILING | 06/04/2026 | APPROVED - AS NOTED | CVANSTRAHLEN |
| Note: Item from previous inspection still pending , please fix New inspection due to canceled inspection Inspector Notes from Inspection 2460 Please fix item before next inspection #1-Truss T05 on left side by entrance required repair , please used mitek truss pack repair for | |||
| ROOF VALLEY & METAL | 06/04/2026 | APPROVED | CVANSTRAHLEN |
| FIREWALL DRYWALL NAILING | 06/03/2026 | CANCELLED BY APPLICANT | WEB |
| Note: Inspector Notes from Inspection 2460 Please fix item before next inspection #1-Truss T05 required repair , please used mitek truss pack repair for | |||
| FIREWALL FRAMING | 05/29/2026 | APPROVED | CVANSTRAHLEN |
| WALL SHEATHING | 05/29/2026 | APPROVED | CVANSTRAHLEN |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 05/29/2026 | APPROVED - AS NOTED | CVANSTRAHLEN |
| Note: Please fix item before next inspection #1-Truss T05 required repair , please used mitek truss pack repair for | |||
| TIE BEAM / LINTEL | 05/14/2026 | APPROVED | CVANSTRAHLEN |
| TIE BEAM / LINTEL | 05/13/2026 | CANCELLED BY APPLICANT | WEB |
| MONOLITHIC SLAB | 04/23/2026 | Disapproved -FEE REQUIRED | KSANDOE |
| Note: Item #1 has not been addressed 4/22/2026 - PREVIOUS INSPECTION NOTES Please fix items before next inspection #1-FBC R404.1.3.3.7.5-SLAB MINIMUM THICKNESS 3 1/2 " ( mark with green , please check ) #2-requirement per FL building code space between rebars and soild required tobe 3" #3-FBCR 318-MISSING UFER GROUND - CONCRETE ENCASED ELECTRODE ARE ( Removed 5'of 6 MIL VAPOR BARRIER were ufer is install ) #4-please removed roots from fotters ( left side )FBCRP2603.4 #5-FBCR 506.2.1-COMPACT EXCAVATED AREAS (right side unit , back area ) #6-FBC 3303.5-SWALE CLEAR | |||
| MONOLITHIC SLAB | 04/23/2026 | APPROVED | KSANDOE |
| Note: 4/23/2026 - PREVIOUS INSPECTION NOTES Item #1 has not been addressed 4/22/2026 - PREVIOUS INSPECTION NOTES Please fix items before next inspection #1-FBC R404.1.3.3.7.5-SLAB MINIMUM THICKNESS 3 1/2 " ( mark with green , please check ) #2-requirement per FL building code space between rebars and soild required tobe 3" #3-FBCR 318-MISSING UFER GROUND - CONCRETE ENCASED ELECTRODE ARE ( Removed 5'of 6 MIL VAPOR BARRIER were ufer is install ) #4-please removed roots from fotters ( left side )FBCRP2603.4 #5-FBCR 506.2.1-COMPACT EXCAVATED AREAS (right side unit , back area ) #6-FBC 3303.5-SWALE CLEAR | |||
| MONOLITHIC SLAB | 04/22/2026 | Disapproved -FEE REQUIRED | CVANSTRAHLEN |
| Note: Please fix items before next inspection #1-FBC R404.1.3.3.7.5-SLAB MINIMUM THICKNESS 3 1/2 " ( mark with green , please check ) #2-requirement per FL building code space between rebars and soild required tobe 3" #3-FBCR 318-MISSING UFER GROUND - CONCRETE ENCASED ELECTRODE ARE ( Removed 5'of 6 MIL VAPOR BARRIER were ufer is install ) #4-please removed roots from fotters ( left side )FBCRP2603.4 #5-FBCR 506.2.1-COMPACT EXCAVATED AREAS (right side unit , back area ) #6-FBC 3303.5-SWALE CLEAR | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 04/17/2026 | APPROVED | CVANSTRAHLEN |
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | 04/16/2026 | APPROVED | PKNAPIK |
| FORMBOARD SURVEY (OFFICE USE ONLY) | 04/15/2026 | APPROVED | RRICKS |
| WATER METER INSTALLATION REQUEST | 04/01/2026 | APPROVED | ISANDERSON |
| PEP TANK INSTALLATION REQUEST | |||
| U-CROSS CONNECTION | |||
| ROW- PRE-APRON (PRE-POUR) | |||
| ROW - FINAL APRON (AFTER POUR) | |||
| ROW - FINAL INSPECTION | |||
| U -UTILITY RESIDENTIAL FINAL | |||
| INSULATION | |||
| DRYWALL NAILING | |||
| BLD - BUILDING FINAL | |||
| LATH/BRICK/ WATER BARRIER | |||
| GRAVITY SEWER TEST | |||
| SEWER TIE IN | |||
| ELECTRIC - EARLY POWER | |||
| ALL ROUGH | |||
| FIREWALL FINAL |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 04/16/2026 | 04/16/2026 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 04/15/2026 | 04/15/2026 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 04/15/2026 | 04/15/2026 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 04/15/2026 | 04/15/2026 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 04/06/2026 | 04/06/2026 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 03/31/2026 | 03/31/2026 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 03/31/2026 | 04/02/2026 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | HOLD | 03/31/2026 | 04/01/2026 |
| Note: Held By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM Please bring in original ROW agreement | |||
| ENGIN1 | COMPLETE | 03/31/2026 | 04/10/2026 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 03/18/2026 | 03/18/2026 |
| Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 03/18/2026 | 03/23/2026 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| ZON | HOLD | 03/12/2026 | 03/12/2026 |
| Note: Held By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM SUBMIT UPDATED ROOF WORKSHEET. CAN BE FOUND ON WEBSITE WWW.PALMCOAST.GOV/BUILDING | |||
| ELEC | COMPLETE | 03/12/2026 | 03/16/2026 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 03/12/2026 | 03/18/2026 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 03/02/2026 | 03/11/2026 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| BLD | HOLD | 02/27/2026 | 03/05/2026 |
| Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM 1. Truss layout from manufacturer for wrong address. 2. Product Approval FL# 28093.1 Manufacturer listed does not correspond to product FL# 28093.4 Manufacturer listed does not correspond to product | |||
| CUSVC | COMPLETE | 02/27/2026 | 03/04/2026 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | HOLD | 02/27/2026 | 03/04/2026 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need correct outlet spacing in living room. NEC 2020 210.52 | |||
| ENGIN1 | COMPLETE | 02/27/2026 | 03/02/2026 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 02/27/2026 | 03/02/2026 |
| LOCATE | COMPLETE | 02/27/2026 | 03/02/2026 |
| Note: Released By: IVAN SANDERSON - - | |||
| MECH | COMPLETE | 02/27/2026 | 03/02/2026 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 02/27/2026 | 03/04/2026 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ZON | HOLD | 02/27/2026 | 03/04/2026 |
| Note: Held By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM SUBMIT UPDATED COLOR MATERIAL SHEET |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| RECORDING FEE REIMBURSE DOC | ¤52.50 | 05/28/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 05/28/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 05/28/2026 |
| FC IMPACT FEE EMS | ¤124.00 | 03/31/2026 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤436.00 | 03/31/2026 |
| FC IMPACT FEE LIBRARY | ¤536.00 | 03/31/2026 |
| FIRE RES IMPACT FEE 10-25 | ¤1,884.00 | 03/31/2026 |
| WATER- TURN ON | ¤100.00 | 03/31/2026 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 03/31/2026 |
| INSPECTION - RESIDENTIAL | ¤1,303.50 | 03/31/2026 |
| PLAN REVIEW - RESIDENTIAL | ¤369.72 | 03/31/2026 |
| PEP TANK INSTALL | ¤1,513.48 | 03/31/2026 |
| PARKS IMPACT FEE 10-25 | ¤6,328.00 | 03/31/2026 |
| RSI DRIVEWAY AFTER POUR | ¤16.25 | 03/31/2026 |
| RSE DRIVE PRE POUR INSPECTION | ¤32.50 | 03/31/2026 |
| RSI FIELD SURVEY INSPECTION | ¤48.75 | 03/31/2026 |
| RSI FORMBOARD REVIEW | ¤16.25 | 03/31/2026 |
| RSI PLAN REVIEW NEW | ¤48.75 | 03/31/2026 |
| RSI FNL SURVEY/GRADING CERT | ¤48.75 | 03/31/2026 |
| RSI ROW FINAL INSPECTION | ¤16.25 | 03/31/2026 |
| SCHOOL BOARD IMPACT FEE RES | ¤10,900.00 | 03/31/2026 |
| WASTEWATER MAIN EXTENSION IMPA | ¤4,770.00 | 03/31/2026 |
| SURCHARGE FS 533.721 | ¤17.03 | 03/31/2026 |
| SURCHARGE - FS 468.631 | ¤25.55 | 03/31/2026 |
| SW ENG RES REVIEW 240 | ¤240.00 | 03/31/2026 |
| WATER METER W/ TAP | ¤4,653.86 | 03/31/2026 |
| TRANS DUPLEX 10-25 | ¤9,177.60 | 03/31/2026 |
| SEWER CREDIT | (¤2,294.00) | 03/31/2026 |
| WASTEWATER PERM INSPECTION | ¤80.00 | 03/31/2026 |
| WASTEWATER PERM REVIEW | ¤100.00 | 03/31/2026 |
| SEWER CAPITAL FACILITY | ¤8,830.00 | 03/31/2026 |
| WATER CAPITAL FACILITY FEE | ¤7,580.98 | 03/31/2026 |
| WATER PERMIT INSPECTION | ¤80.00 | 03/31/2026 |
| WATER MAIN EXTENSION IMPACT | ¤1,834.54 | 03/31/2026 |
| SITE PLAN 30 | ¤30.00 | 03/31/2026 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤59,010.26 |