I want to search for...

Permit #2026021094

Permit Details

Status: INSPECT

Parcel Id: 07-11-31-7031-00170-0090
CONDITIONED SPACE: 2400 sqft
GARAGE: 566 sqft
OPENED PORCH (WITH ROOF) : 350 sqft
Total Square Footage: 3316 sqft
Block: 00170
Subdivision: 2166 - SECTION 31-ROYAL PALMS
Job Phone: 386-283-2035
Location Address: 7 RIDDLE PL
Type: DU - DUPLEX
Issue Date: 03/31/2026
NOC: RECORDED
Applicant name: OLEG BELINSKIY
Owner: CORNERSTONE REALTY AND TRUST LLC

Address

2021 E CLOVELLY LANE

SAINT AUGUSTINE, FL 32092

Lot: 0090
Contracted Stated Job Value: ¤350,000.00
Job Description: DUPLEX
Type: CN

Contractor

FLORIDAS BEST BUILDERS INC
Status Location Address State License Number Phone
ACTIVE

19 PINE CIRCLE DRIVE

PALM COAST, FL 32164

CBC1264760 (Exp: 08/31/2026) 386-283-2035

Sub Contractors

OLEG BELINSKIY
Status Location Address State License Number Phone
ACTIVE

19 PINE CIRCLE DRIVE19

PALM COAST, FL 32167

CCC1325974 (Exp: 08/31/2026) 386-263-7906
TIMUR ISPARYAN
Status Location Address State License Number Phone Fax
ACTIVE

3665 SPRINK PARK ROAD

JACKSONVILLE , FL 32207

CMC1249968 (Exp: 08/31/2026) 904-245-1818 904-337-1910
JUAN CARLOS GONZALEZ
Status Location Address State License Number
ACTIVE

1328 COUNTY ROAD 308

CRESCENT CITY, FL 32112

RF11067806 (Exp: 08/31/2027)
SERGEY A VORONIN
Status Location Address State License Number Phone
ACTIVE

7631 SEVERN

JACKSONVILLE, FL 32224

EC13011326 (Exp: 08/31/2026) 360-798-2819

Inspection History

Type Request Date Result Inspector
FIREWALL DRYWALL NAILING 06/04/2026 APPROVED - AS NOTED CVANSTRAHLEN
Note: Item from previous inspection still pending , please fix New inspection due to canceled inspection Inspector Notes from Inspection 2460 Please fix item before next inspection #1-Truss T05 on left side by entrance required repair , please used mitek truss pack repair for
ROOF VALLEY & METAL 06/04/2026 APPROVED CVANSTRAHLEN
FIREWALL DRYWALL NAILING 06/03/2026 CANCELLED BY APPLICANT WEB
Note: Inspector Notes from Inspection 2460 Please fix item before next inspection #1-Truss T05 required repair , please used mitek truss pack repair for
FIREWALL FRAMING 05/29/2026 APPROVED CVANSTRAHLEN
WALL SHEATHING 05/29/2026 APPROVED CVANSTRAHLEN
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/29/2026 APPROVED - AS NOTED CVANSTRAHLEN
Note: Please fix item before next inspection #1-Truss T05 required repair , please used mitek truss pack repair for
TIE BEAM / LINTEL 05/14/2026 APPROVED CVANSTRAHLEN
TIE BEAM / LINTEL 05/13/2026 CANCELLED BY APPLICANT WEB
MONOLITHIC SLAB 04/23/2026 Disapproved -FEE REQUIRED KSANDOE
Note: Item #1 has not been addressed 4/22/2026 - PREVIOUS INSPECTION NOTES Please fix items before next inspection #1-FBC R404.1.3.3.7.5-SLAB MINIMUM THICKNESS 3 1/2 " ( mark with green , please check ) #2-requirement per FL building code space between rebars and soild required tobe 3" #3-FBCR 318-MISSING UFER GROUND - CONCRETE ENCASED ELECTRODE ARE ( Removed 5'of 6 MIL VAPOR BARRIER were ufer is install ) #4-please removed roots from fotters ( left side )FBCRP2603.4 #5-FBCR 506.2.1-COMPACT EXCAVATED AREAS (right side unit , back area ) #6-FBC 3303.5-SWALE CLEAR
MONOLITHIC SLAB 04/23/2026 APPROVED KSANDOE
Note: 4/23/2026 - PREVIOUS INSPECTION NOTES Item #1 has not been addressed 4/22/2026 - PREVIOUS INSPECTION NOTES Please fix items before next inspection #1-FBC R404.1.3.3.7.5-SLAB MINIMUM THICKNESS 3 1/2 " ( mark with green , please check ) #2-requirement per FL building code space between rebars and soild required tobe 3" #3-FBCR 318-MISSING UFER GROUND - CONCRETE ENCASED ELECTRODE ARE ( Removed 5'of 6 MIL VAPOR BARRIER were ufer is install ) #4-please removed roots from fotters ( left side )FBCRP2603.4 #5-FBCR 506.2.1-COMPACT EXCAVATED AREAS (right side unit , back area ) #6-FBC 3303.5-SWALE CLEAR
MONOLITHIC SLAB 04/22/2026 Disapproved -FEE REQUIRED CVANSTRAHLEN
Note: Please fix items before next inspection #1-FBC R404.1.3.3.7.5-SLAB MINIMUM THICKNESS 3 1/2 " ( mark with green , please check ) #2-requirement per FL building code space between rebars and soild required tobe 3" #3-FBCR 318-MISSING UFER GROUND - CONCRETE ENCASED ELECTRODE ARE ( Removed 5'of 6 MIL VAPOR BARRIER were ufer is install ) #4-please removed roots from fotters ( left side )FBCRP2603.4 #5-FBCR 506.2.1-COMPACT EXCAVATED AREAS (right side unit , back area ) #6-FBC 3303.5-SWALE CLEAR
PLUMBING 1ST ROUGH UNDERGROUND 04/17/2026 APPROVED CVANSTRAHLEN
GEOTECHNICAL REPORT APPROVAL (OFFICE USE) 04/16/2026 APPROVED PKNAPIK
FORMBOARD SURVEY (OFFICE USE ONLY) 04/15/2026 APPROVED RRICKS
WATER METER INSTALLATION REQUEST 04/01/2026 APPROVED ISANDERSON
PEP TANK INSTALLATION REQUEST
U-CROSS CONNECTION
ROW- PRE-APRON (PRE-POUR)
ROW - FINAL APRON (AFTER POUR)
ROW - FINAL INSPECTION
U -UTILITY RESIDENTIAL FINAL
INSULATION
DRYWALL NAILING
BLD - BUILDING FINAL
LATH/BRICK/ WATER BARRIER
GRAVITY SEWER TEST
SEWER TIE IN
ELECTRIC - EARLY POWER
ALL ROUGH
FIREWALL FINAL

Review History

Department Status Date In Date Out
BLD COMPLETE 04/16/2026 04/16/2026
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
SW1 COMPLETE 04/15/2026 04/15/2026
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 04/15/2026 04/15/2026
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BLD COMPLETE 04/15/2026 04/15/2026
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
ZON COMPLETE 04/06/2026 04/06/2026
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
BLD COMPLETE 03/31/2026 03/31/2026
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
SW1 COMPLETE 03/31/2026 04/02/2026
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON HOLD 03/31/2026 04/01/2026
Note: Held By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM Please bring in original ROW agreement
ENGIN1 COMPLETE 03/31/2026 04/10/2026
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
ZON COMPLETE 03/18/2026 03/18/2026
Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM
BLD COMPLETE 03/18/2026 03/23/2026
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
ZON HOLD 03/12/2026 03/12/2026
Note: Held By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM SUBMIT UPDATED ROOF WORKSHEET. CAN BE FOUND ON WEBSITE WWW.PALMCOAST.GOV/BUILDING
ELEC COMPLETE 03/12/2026 03/16/2026
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 03/12/2026 03/18/2026
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
SWALE COMPLETE 03/02/2026 03/11/2026
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
BLD HOLD 02/27/2026 03/05/2026
Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM 1. Truss layout from manufacturer for wrong address. 2. Product Approval FL# 28093.1 Manufacturer listed does not correspond to product FL# 28093.4 Manufacturer listed does not correspond to product
CUSVC COMPLETE 02/27/2026 03/04/2026
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC HOLD 02/27/2026 03/04/2026
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need correct outlet spacing in living room. NEC 2020 210.52
ENGIN1 COMPLETE 02/27/2026 03/02/2026
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
GAS CANCEL 02/27/2026 03/02/2026
LOCATE COMPLETE 02/27/2026 03/02/2026
Note: Released By: IVAN SANDERSON - -
MECH COMPLETE 02/27/2026 03/02/2026
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 02/27/2026 03/04/2026
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON HOLD 02/27/2026 03/04/2026
Note: Held By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM SUBMIT UPDATED COLOR MATERIAL SHEET

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
RECORDING FEE REIMBURSE DOC ¤52.50 05/28/2026
REINSPECTION RESIDENTIAL ¤40.00 05/28/2026
REINSPECTION RESIDENTIAL ¤40.00 05/28/2026
FC IMPACT FEE EMS ¤124.00 03/31/2026
FC IMPACT FEE LAW ENFORCEMENT ¤436.00 03/31/2026
FC IMPACT FEE LIBRARY ¤536.00 03/31/2026
FIRE RES IMPACT FEE 10-25 ¤1,884.00 03/31/2026
WATER- TURN ON ¤100.00 03/31/2026
ADMINISTRATIVE RESIDENTIAL ¤30.00 03/31/2026
INSPECTION - RESIDENTIAL ¤1,303.50 03/31/2026
PLAN REVIEW - RESIDENTIAL ¤369.72 03/31/2026
PEP TANK INSTALL ¤1,513.48 03/31/2026
PARKS IMPACT FEE 10-25 ¤6,328.00 03/31/2026
RSI DRIVEWAY AFTER POUR ¤16.25 03/31/2026
RSE DRIVE PRE POUR INSPECTION ¤32.50 03/31/2026
RSI FIELD SURVEY INSPECTION ¤48.75 03/31/2026
RSI FORMBOARD REVIEW ¤16.25 03/31/2026
RSI PLAN REVIEW NEW ¤48.75 03/31/2026
RSI FNL SURVEY/GRADING CERT ¤48.75 03/31/2026
RSI ROW FINAL INSPECTION ¤16.25 03/31/2026
SCHOOL BOARD IMPACT FEE RES ¤10,900.00 03/31/2026
WASTEWATER MAIN EXTENSION IMPA ¤4,770.00 03/31/2026
SURCHARGE FS 533.721 ¤17.03 03/31/2026
SURCHARGE - FS 468.631 ¤25.55 03/31/2026
SW ENG RES REVIEW 240 ¤240.00 03/31/2026
WATER METER W/ TAP ¤4,653.86 03/31/2026
TRANS DUPLEX 10-25 ¤9,177.60 03/31/2026
SEWER CREDIT (¤2,294.00) 03/31/2026
WASTEWATER PERM INSPECTION ¤80.00 03/31/2026
WASTEWATER PERM REVIEW ¤100.00 03/31/2026
SEWER CAPITAL FACILITY ¤8,830.00 03/31/2026
WATER CAPITAL FACILITY FEE ¤7,580.98 03/31/2026
WATER PERMIT INSPECTION ¤80.00 03/31/2026
WATER MAIN EXTENSION IMPACT ¤1,834.54 03/31/2026
SITE PLAN 30 ¤30.00 03/31/2026
Fees Total Due: ¤0.00 Total Paid: ¤59,010.26