I want to search for...
Permit #2026030059
Permit Details
Status: INSPECT
| Parcel Id: 35-11-31-4075-00000-0840 |
| Block: 00000 |
| Subdivision: 2296 - MARINA DEL PALMA SUBDIVISION |
| Job Phone: 838-684-6512 X9 |
| Location Address: 33 DEL PALMA DR |
| Type: PO - POOL |
| Issue Date: 03/23/2026 |
| NOC: RECORDED |
| Applicant name: SAMANTHA JESSICA ALEXANDER |
| Owner: WHELAN JAMES & HEIDI H&W |
|
Address 2823 W PAINTED CANYON WAY HIGHLANDS RANCH, CO 80129 |
| Lot: 0840 |
| Contracted Stated Job Value: ¤90,000.00 |
| Job Description: swimming pool |
| Type: CN |
Contractor
AFFORDABLE POOLS INC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3438 LONGLEAF ROAD , |
CPC1460092 (Exp: 08/31/2026) | 838-684-6512 X9 |
Sub Contractors
COLE ROBERT WARD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
1637 CORDOVA AVE HOLLY HILL, FL 32117 |
EC13012348 (Exp: 08/31/2026) | 386-506-9925 |
Inspection History
| Type | Request Date | Result | Inspector |
| ELECTRIC AND ALARM | 06/09/2026 | APPROVED - AS NOTED | CVANSTRAHLEN |
| Note: Please fix items before next inspection #1-at the moment of the inspection notice a new gas line , new gas heater aquitment was installed by pool aquitment , not gas permit , no gas sub-contractor listed . required gas rough inspection and final gas , please res-summit all documents , plans , riser diagram for revision and approval | |||
| POOL DECK | 05/06/2026 | APPROVED - AS NOTED | MCONTRYMAN |
| Note: 5/6/26 At time of inspection, no plans for a screen enclosure were submitted and therefore no footers were present | |||
| STEEL AND GROUND | 04/10/2026 | APPROVED | CVANSTRAHLEN |
| GAS ROUGH | |||
| Note: This inspection added to inspect newly installed gas piping run underground. This will require opening the trench or installing sight tubes for inspection. | |||
| POOL FINAL | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | |||
| ROW - FINAL INSPECTION | |||
| U -UTILITY RESIDENTIAL FINAL |
Review History
| Department | Status | Date In | Date Out |
| ZON | COMPLETE | 03/18/2026 | 03/20/2026 |
| Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM | |||
| ZON | HOLD | 03/09/2026 | 03/10/2026 |
| Note: Held By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM 1. IF THERE IS TO BE A "FENCE BY OTHERS" THERE MUST BE A FENCE PERMIT (ACKNOWLEDGEMENT BY OWNER OF PROPERTY AS TO FENCE REQUIREMENTS) ON RECORD PRIOR TO ISSUANCE OF A POOL PERMIT. | |||
| MECH | COMPLETE | 03/09/2026 | 03/10/2026 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 03/09/2026 | 03/12/2026 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| RSI | COMPLETE | 03/09/2026 | 03/16/2026 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| BFLOOD | CANCEL | 03/02/2026 | 03/06/2026 |
| BLD | HOLD | 03/02/2026 | 03/06/2026 |
| Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM Pool needs to be enclosed with screen or fence. Provide engineering for screen or on site plans indicate fence with note that gates are outswing and self latching. Also, latches need to be at 54" | |||
| ELEC | COMPLETE | 03/02/2026 | 03/04/2026 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | HOLD | 03/02/2026 | 03/03/2026 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide gas riser diagram and list gas subcontractor or put note on plans "Gas By Others" | |||
| RSI | HOLD | 03/02/2026 | 03/09/2026 |
| Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM THE SITE PLAN MUST HAVE PROPOSED ELEVATIONS OR FLOW ARROWS OF THE NEW DRAINAGE OF THE LOT. ALL DRAINAGE MUST NOT IMPACT ANY ADJACENT LOT OR HOUSE OR POOL. | |||
| ZON | HOLD | 03/02/2026 | 03/03/2026 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Site plan: show how the pool will be enclosed on the property. Pool must be fully enclosed by fence (height/material/color as allowed by City Land Development Code) or screen enclosure. A baby fence does not meet the Land Development Code requirements. Please demonstrate the proposed fence meets Land Development Code requirements as per Chapter 4 of the Land Development Code. IF THERE IS TO BE A "FENCE BY OTHERS" THERE MUST BE A FENCE PERMIT (ACKNOWLEDGEMENT BY OWNER OF PROPERTY AS TO FENCE REQUIREMENTS) ON RECORD PRIOR TO ISSUANCE OF A POOL PERMIT. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 03/23/2026 |
| INSPECTION- POOL | ¤160.00 | 03/23/2026 |
| PLAN REVIEW - RESIDENTIAL | ¤70.20 | 03/23/2026 |
| RSI FIELD SURVEY INSPECTION | ¤48.75 | 03/23/2026 |
| RSI PLAN REVIEW NEW | ¤48.75 | 03/23/2026 |
| RSI FNL SURVEY/GRADING CERT | ¤48.75 | 03/23/2026 |
| RSI ROW FINAL INSPECTION | ¤16.25 | 03/23/2026 |
| SURCHARGE FS 533.721 | ¤2.60 | 03/23/2026 |
| SURCHARGE - FS 468.631 | ¤3.90 | 03/23/2026 |
| SITE PLAN 30 | ¤30.00 | 03/23/2026 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤459.20 |