Permit #2026030150
Permit Details
Status: INSPECT
| Parcel Id: 04-11-30-5571-00000-3430 |
| CONDITIONED SPACE: 2568 sqft |
| GARAGE: 430 sqft |
| OPENED PORCH (WITH ROOF) : 79 sqft |
| OPENED PORCH (WITH ROOF) : 240 sqft |
| Total Square Footage: 3317 sqft |
| Subdivision: 2366 - SOMERSET SUBDIVISION PH 2 |
| Job Phone: 904-596-6645 |
| Location Address: 55 SOMERSET AVE |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 03/18/2026 |
| NOC: RECORDED |
| Applicant name: MICHAEL T HOLDER |
| Owner: KB HOME JACKSONVILLE LLC |
|
Address 10475 FORTUNE PARKWAY JACKSONVILLE, FL 32256 |
|
Address SUITE 100 JACKSONVILLE, FL 32256 |
| Lot: 343 |
| Contracted Stated Job Value: ¤140,000.00 |
| Job Description: NEW SINGLE FAMILY DWELLING |
| Type: CN |
Contractor
KB HOME JACKSONVILLE, LLC
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
10475 FORTUNE PKWY JACKSONVILLE, FL 32256 |
SUITE 100 JACKSONVILLE, FL 32256 |
CGC1509034 (Exp: 08/31/2026) | 904-596-6645 |
Sub Contractors
LARRY WILLIAMS
| Status | Location Address | State License Number | Phone |
| ACTIVE |
1750 EMERSON ST JACKSONVILLE, FL 32207 |
LI45034 (Exp: 08/31/2026) | 904-721-5431 |
BOBBY WAYNE CAMPBELL
| Status | Location Address | State License Number | Phone |
| ACTIVE |
117 GUTHRIE ROAD GREEN COVE SPRINGS, FL 32043 |
CCC1326752 (Exp: 08/31/2026) | 904-200-1600 |
JAMES E LINTON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
200 COLLEGE DR ORANGE PARK, FL 32065 |
EC0001152 (Exp: 08/31/2026) | 904-272-0272 |
COREY MICHAEL TENNANT
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3370 AGRICULTURAL CNETER DR ST AUGUSTINE, FL 32092 |
CAC1819063 (Exp: 08/31/2026) | 904-829-8898 |
BENJAMIN MICHAEL RAY
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| ACTIVE |
6310 MABLETON PKWY JACKSONVILLE, FL 32216 |
SUITE 1000 MABLETON, GA 30126 |
CFC1428415 (Exp: 08/31/2026) | 904-861-5421 | 904-861-5426 |
Inspection History
| Type | Request Date | Result | Inspector |
| ROW- PRE-APRON (PRE-POUR) | 06/04/2026 | APPROVED - AS NOTED | EMADISON |
| Note: ** 06/04/26 ** READY TO POUR ** AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE | |||
| DRYWALL NAILING | 05/26/2026 | APPROVED | HCAMACHO |
| INSULATION | 05/22/2026 | APPROVED | HCAMACHO |
| Note: Inspector Notes from Inspection 2420 This inspection is for the Bath room adding shower/tub Inspector Notes from Inspection 2250 1. This is for the Bath room downstairs adding a bath tub. Inspector Notes from Inspection 2320 Inspector Notes from Inspection 2420 Previous Note not rectified.....1. Gable End Bracing on 2nd floor missing brackets (HGA 10's at bottom chord per detail A pg s6) Per plan. 1. Missing Nail shields for electric thru out the 1st floor. (to many to list) NEC 300.4 2. Master toilet exhaust duct needs sealed and mechanically fastened at the fan assembly. FBCR M1601.4.1 3. All bath exhaust ducts 1st and 2nd floor need Mechanical fasteners at duct to fan assembly. FBCR M1601.4.1 Will need all repairs prior to Insulation inspection approval. Inspector Notes from Inspection 2460 1. Gable End Bracing on 2nd floor missing brackets. Box is there but nothing was used. See Plans. 2. Missing CS16 Between Floors at built up posts 4 locations. See Plans 3. Missing (2) 2x4 post under B2 truss. See plans. 4. Missing 2x4 blocking @12" O.C. along Shearwall to I-Joinst. See Plans. *Will check at Rough Inspection*. 4/16/2026 - PREVIOUS INSPECTION NOTES No plans onsite. FBC [A]107.3.1 No truss drawings onsite. Trades are in the building working, Please reschedule when trades are not working over head, and floor is free of debri. | |||
| LATH/BRICK/ WATER BARRIER | 05/22/2026 | APPROVED | HCAMACHO |
| Note: Inspector Notes from Inspection 2250 1. This is for the Bath room downstairs adding a bath tub. Inspector Notes from Inspection 2320 Inspector Notes from Inspection 2420 Previous Note not rectified.....1. Gable End Bracing on 2nd floor missing brackets (HGA 10's at bottom chord per detail A pg s6) Per plan. 1. Missing Nail shields for electric thru out the 1st floor. (to many to list) NEC 300.4 2. Master toilet exhaust duct needs sealed and mechanically fastened at the fan assembly. FBCR M1601.4.1 3. All bath exhaust ducts 1st and 2nd floor need Mechanical fasteners at duct to fan assembly. FBCR M1601.4.1 Will need all repairs prior to Insulation inspection approval. Inspector Notes from Inspection 2460 1. Gable End Bracing on 2nd floor missing brackets. Box is there but nothing was used. See Plans. 2. Missing CS16 Between Floors at built up posts 4 locations. See Plans 3. Missing (2) 2x4 post under B2 truss. See plans. 4. Missing 2x4 blocking @12" O.C. along Shearwall to I-Joinst. See Plans. *Will check at Rough Inspection*. 4/16/2026 - PREVIOUS INSPECTION NOTES No plans onsite. FBC [A]107.3.1 No truss drawings onsite. Trades are in the building working, Please reschedule when trades are not working over head, and floor is free of debri. | |||
| ALL ROUGH | 05/22/2026 | APPROVED - AS NOTED | HCAMACHO |
| Note: This inspection is for the Bath room adding shower/tub Inspector Notes from Inspection 2250 1. This is for the Bath room downstairs adding a bath tub. Inspector Notes from Inspection 2320 Inspector Notes from Inspection 2420 Previous Note not rectified.....1. Gable End Bracing on 2nd floor missing brackets (HGA 10's at bottom chord per detail A pg s6) Per plan. 1. Missing Nail shields for electric thru out the 1st floor. (to many to list) NEC 300.4 2. Master toilet exhaust duct needs sealed and mechanically fastened at the fan assembly. FBCR M1601.4.1 3. All bath exhaust ducts 1st and 2nd floor need Mechanical fasteners at duct to fan assembly. FBCR M1601.4.1 Will need all repairs prior to Insulation inspection approval. Inspector Notes from Inspection 2460 1. Gable End Bracing on 2nd floor missing brackets. Box is there but nothing was used. See Plans. 2. Missing CS16 Between Floors at built up posts 4 locations. See Plans 3. Missing (2) 2x4 post under B2 truss. See plans. 4. Missing 2x4 blocking @12" O.C. along Shearwall to I-Joinst. See Plans. *Will check at Rough Inspection*. 4/16/2026 - PREVIOUS INSPECTION NOTES No plans onsite. FBC [A]107.3.1 No truss drawings onsite. Trades are in the building working, Please reschedule when trades are not working over head, and floor is free of debri. | |||
| MONOLITHIC SLAB | 05/21/2026 | APPROVED - AS NOTED | HCAMACHO |
| Note: 1. This is for the Bath room downstairs adding a bath tub. Inspector Notes from Inspection 2320 Inspector Notes from Inspection 2420 Previous Note not rectified.....1. Gable End Bracing on 2nd floor missing brackets (HGA 10's at bottom chord per detail A pg s6) Per plan. 1. Missing Nail shields for electric thru out the 1st floor. (to many to list) NEC 300.4 2. Master toilet exhaust duct needs sealed and mechanically fastened at the fan assembly. FBCR M1601.4.1 3. All bath exhaust ducts 1st and 2nd floor need Mechanical fasteners at duct to fan assembly. FBCR M1601.4.1 Will need all repairs prior to Insulation inspection approval. Inspector Notes from Inspection 2460 1. Gable End Bracing on 2nd floor missing brackets. Box is there but nothing was used. See Plans. 2. Missing CS16 Between Floors at built up posts 4 locations. See Plans 3. Missing (2) 2x4 post under B2 truss. See plans. 4. Missing 2x4 blocking @12" O.C. along Shearwall to I-Joinst. See Plans. *Will check at Rough Inspection*. 4/16/2026 - PREVIOUS INSPECTION NOTES No plans onsite. FBC [A]107.3.1 No truss drawings onsite. Trades are in the building working, Please reschedule when trades are not working over head, and floor is free of debri. | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 05/20/2026 | APPROVED - AS NOTED | HCAMACHO |
| Note: Note- Changing bath from 1/2 to full, adding bath tube. | |||
| LATH/BRICK/ WATER BARRIER | 04/30/2026 | APPROVED - AS NOTED | JSTEWART |
| Note: Inspector Notes from Inspection 2420 Previous Note not rectified.....1. Gable End Bracing on 2nd floor missing brackets (HGA 10's at bottom chord per detail A pg s6) Per plan. 1. Missing Nail shields for electric thru out the 1st floor. (to many to list) NEC 300.4 2. Master toilet exhaust duct needs sealed and mechanically fastened at the fan assembly. FBCR M1601.4.1 3. All bath exhaust ducts 1st and 2nd floor need Mechanical fasteners at duct to fan assembly. FBCR M1601.4.1 Will need all repairs prior to Insulation inspection approval. Inspector Notes from Inspection 2460 1. Gable End Bracing on 2nd floor missing brackets. Box is there but nothing was used. See Plans. 2. Missing CS16 Between Floors at built up posts 4 locations. See Plans 3. Missing (2) 2x4 post under B2 truss. See plans. 4. Missing 2x4 blocking @12" O.C. along Shearwall to I-Joinst. See Plans. *Will check at Rough Inspection*. 4/16/2026 - PREVIOUS INSPECTION NOTES No plans onsite. FBC [A]107.3.1 No truss drawings onsite. Trades are in the building working, Please reschedule when trades are not working over head, and floor is free of debri. | |||
| ELECTRIC-TUG | 04/24/2026 | APPROVED - AS NOTED | JSTEWART |
| Note: this inspection was approved prior on 4/21/26. Inspector Notes from Inspection 2200 Authorize release of email. | |||
| ALL ROUGH | 04/21/2026 | APPROVED - AS NOTED | JSTEWART |
| Note: Previous Note not rectified.....1. Gable End Bracing on 2nd floor missing brackets (HGA 10's at bottom chord per detail A pg s6) Per plan. 1. Missing Nail shields for electric thru out the 1st floor. (to many to list) NEC 300.4 2. Master toilet exhaust duct needs sealed and mechanically fastened at the fan assembly. FBCR M1601.4.1 3. All bath exhaust ducts 1st and 2nd floor need Mechanical fasteners at duct to fan assembly. FBCR M1601.4.1 Will need all repairs prior to Insulation inspection approval. Inspector Notes from Inspection 2460 1. Gable End Bracing on 2nd floor missing brackets. Box is there but nothing was used. See Plans. 2. Missing CS16 Between Floors at built up posts 4 locations. See Plans 3. Missing (2) 2x4 post under B2 truss. See plans. 4. Missing 2x4 blocking @12" O.C. along Shearwall to I-Joinst. See Plans. *Will check at Rough Inspection*. 4/16/2026 - PREVIOUS INSPECTION NOTES No plans onsite. FBC [A]107.3.1 No truss drawings onsite. Trades are in the building working, Please reschedule when trades are not working over head, and floor is free of debri. | |||
| ELECTRIC-TUG | 04/21/2026 | APPROVED - AS NOTED | JSTEWART |
| Note: Authorize release of email. | |||
| ROOF VALLEY & METAL | 04/20/2026 | APPROVED | HCAMACHO |
| Note: 4/16/2026 - PREVIOUS INSPECTION NOTES Roof sheathing/braces/ties need prior approval. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 04/20/2026 | APPROVED - AS NOTED | HCAMACHO |
| Note: 1. Gable End Bracing on 2nd floor missing brackets. Box is there but nothing was used. See Plans. 2. Missing CS16 Between Floors at built up posts 4 locations. See Plans 3. Missing (2) 2x4 post under B2 truss. See plans. 4. Missing 2x4 blocking @12" O.C. along Shearwall to I-Joinst. See Plans. *Will check at Rough Inspection*. 4/16/2026 - PREVIOUS INSPECTION NOTES No plans onsite. FBC [A]107.3.1 No truss drawings onsite. Trades are in the building working, Please reschedule when trades are not working over head, and floor is free of debri. | |||
| ROOF VALLEY & METAL | 04/16/2026 | Disapproved - NO FEE | JSTEWART |
| Note: Roof sheathing/braces/ties need prior approval. | |||
| WALL SHEATHING | 04/16/2026 | APPROVED | JSTEWART |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 04/16/2026 | Disapproved -FEE REQUIRED | JSTEWART |
| Note: No plans onsite. FBC [A]107.3.1 No truss drawings onsite. Trades are in the building working, Please reschedule when trades are not working over head, and floor is free of debri. | |||
| GRAVITY SEWER TEST | 04/02/2026 | APPROVED | JSTEWART |
| Note: Main water line installed from house shut off to utility location, snubbed up. Inspector Notes from Inspection 2060 Main water supply line from utlility to house not installed, will require inspection at either All Rough or Sewer tie in. | |||
| SEWER TIE IN | 04/02/2026 | APPROVED | JSTEWART |
| Note: Main water line installed from house shut off to utility location, snubbed up. Inspector Notes from Inspection 2060 Main water supply line from utlility to house not installed, will require inspection at either All Rough or Sewer tie in. | |||
| MONOLITHIC SLAB | 03/27/2026 | APPROVED | JSTEWART |
| PLUMBING 1ST ROUGH UNDERGROUND | 03/24/2026 | APPROVED - AS NOTED | JSTEWART |
| Note: Main water supply line from utlility to house not installed, will require inspection at either All Rough or Sewer tie in. | |||
| WATER METER INSTALLATION REQUEST | 03/24/2026 | APPROVED | ISANDERSON |
| FORMBOARD SURVEY (OFFICE USE ONLY) | 03/23/2026 | APPROVED | RRICKS |
| ELECTRIC - EARLY POWER | |||
| U-CROSS CONNECTION | |||
| BLD - BUILDING FINAL | |||
| ROW - FINAL APRON (AFTER POUR) | |||
| ROW - FINAL INSPECTION | |||
| U -UTILITY RESIDENTIAL FINAL |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 05/07/2026 | 05/07/2026 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 05/07/2026 | 05/07/2026 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 05/07/2026 | 05/08/2026 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 05/07/2026 | 05/11/2026 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 03/20/2026 | 03/23/2026 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 03/20/2026 | 03/20/2026 |
| Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 03/10/2026 | 03/16/2026 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 03/05/2026 | 03/05/2026 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 03/04/2026 | 03/09/2026 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 03/04/2026 | 03/09/2026 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | HOLD | 03/04/2026 | 03/09/2026 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Submit Electrical load calculations | |||
| ENGIN1 | COMPLETE | 03/04/2026 | 03/06/2026 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| GAS | COMPLETE | 03/04/2026 | 03/05/2026 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 03/04/2026 | 03/06/2026 |
| Note: Released By: IVAN SANDERSON - - | |||
| MECH | COMPLETE | 03/04/2026 | 03/05/2026 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 03/04/2026 | 03/06/2026 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| FC IMPACT FEE EMS | ¤62.00 | 03/18/2026 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 03/18/2026 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 03/18/2026 |
| FIRE RES IMPACT FEE 10-25 | ¤942.00 | 03/18/2026 |
| WATER METER W/OUT TAP | ¤965.03 | 03/18/2026 |
| PARKS IMPACT FEE 10-25 | ¤3,164.00 | 03/18/2026 |
| RECLAIM WATER PERMIT INSPECTIO | ¤40.00 | 03/18/2026 |
| RSI DRIVEWAY AFTER POUR | ¤16.25 | 03/18/2026 |
| RSE DRIVE PRE POUR INSPECTION | ¤32.50 | 03/18/2026 |
| RSI FIELD SURVEY INSPECTION | ¤48.75 | 03/18/2026 |
| RSI FORMBOARD REVIEW | ¤16.25 | 03/18/2026 |
| RSI PLAN REVIEW NEW | ¤48.75 | 03/18/2026 |
| RSI FNL SURVEY/GRADING CERT | ¤48.75 | 03/18/2026 |
| RSI ROW FINAL INSPECTION | ¤16.25 | 03/18/2026 |
| SCHOOL BOARD IMPACT FEE RES | ¤5,450.00 | 03/18/2026 |
| SURCHARGE FS 533.721 | ¤17.63 | 03/18/2026 |
| SURCHARGE - FS 468.631 | ¤26.45 | 03/18/2026 |
| TRANSP RES IMPACT FEE 10-25 | ¤9,681.36 | 03/18/2026 |
| WASTEWATER PERM INSPECTION | ¤80.00 | 03/18/2026 |
| WASTEWATER PERM REVIEW | ¤25.00 | 03/18/2026 |
| SEWER CAPITAL FACILITY | ¤3,628.86 | 03/18/2026 |
| WATER CAPITAL FACILITY FEE | ¤3,091.14 | 03/18/2026 |
| WATER PERMIT REVIEW | ¤25.00 | 03/18/2026 |
| SITE PLAN 30 | ¤30.00 | 03/18/2026 |
| WATER-METER | ¤874.47 | 03/18/2026 |
| WATER- TURN ON | ¤50.00 | 03/18/2026 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 03/18/2026 |
| INSPECTION - RESIDENTIAL | ¤1,350.25 | 03/18/2026 |
| PLAN REVIEW - RESIDENTIAL | ¤382.98 | 03/18/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | |
| Fees | Total Due: ¤40.00 | Total Paid: ¤30,629.67 |