I want to search for...
Permit #2026030204
Permit Details
Status: INSPECT
| Parcel Id: 21-12-31-5565-00000-0600 |
| CONDITIONED SPACE: 1466 sqft |
| GARAGE: 248 sqft |
| OPENED PORCH (WITH ROOF) : 31 sqft |
| Total Square Footage: 1745 sqft |
| Subdivision: 2340 - SEMINOLE PALMS TOWN HOMES |
| Job Phone: 407-717-5418 |
| Location Address: 40 ALEXANDER LN |
| Type: TH - TOWNHOUSE |
| Issue Date: 04/06/2026 |
| NOC: RECORDED |
| Applicant name: CARLOS ANTONIO SERRANO |
| Owner: NVR INC |
|
Address 8649 BAYPINE ROAD JACKSONVILLE, FL 32256 |
|
Address BUILDING 5 SUITE 202 JACKSONVILLE, FL 32256 |
| Lot: 60 |
| Contracted Stated Job Value: ¤129,643.00 |
| Job Description: New Construction Townhome |
| Type: CN |
Contractor
RYAN HOMES
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
8649 BAYPINE RD JACKSONVILLE, FL 32256 |
BLDG 7, STE 202 JACKSONVILLE, FL 32256 |
CBC1256450 (Exp: 08/31/2026) | 407-717-5418 |
Sub Contractors
JOSEPH H STRADA JR
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3400 ST JOHNS PKWY SANFORD, FL 32771 |
CAC043953 (Exp: 08/31/2026) | 877-906-1113 |
JOSEPH H STRADA JR
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3400 ST JOHNS PKWY SANFORD, FL 32771 |
CAC043953 (Exp: 08/31/2026) | 877-906-1113 |
JACK DOUGLAS LANIER
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
485 COMMERCE WAY LONGWOOD , FL 32750 |
CCC058022 (Exp: 08/31/2026) | (321)441-2300 | (321)441-2313 |
BRITT MICHAEL JENKINS
| Status | Location Address | State License Number | Phone |
| ACTIVE |
86 COLUMBIA DR POOLER, GA 31322 |
CFC1430770 (Exp: 08/31/2026) | 912-330-8151 |
Inspection History
| Type | Request Date | Result | Inspector |
| FIREWALL DRYWALL NAILING | 05/26/2026 | APPROVED | KSANDOE |
| Note: 5/22/2026 - PREVIOUS INSPECTION NOTES 5/22/26: Cancelled by Applicant in person. Contractor still completing. | |||
| DRYWALL NAILING | 05/26/2026 | APPROVED | KSANDOE |
| Note: 5/22/2026 - PREVIOUS INSPECTION NOTES 5/22/26: Cancelled by Applicant in person. Contractor still completing. | |||
| DRYWALL NAILING | 05/22/2026 | CANCELLED BY APPLICANT | RSIMS |
| Note: 5/22/26: Cancelled by Applicant in person. Contractor still completing. | |||
| FIREWALL DRYWALL NAILING | 05/22/2026 | CANCELLED BY APPLICANT | RSIMS |
| Note: 5/22/26: Cancelled by Applicant in person. Contractor still completing. | |||
| INSULATION | 05/20/2026 | APPROVED | KSANDOE |
| Note: 5/19/2026 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2420 5/14/26: Check at Insulation. 1). Ufer ground rod needs to be placed in wall to protect from damage. NEC-250.64(B)(2) 2). Fireblocking at top of breaker panel is required. FBC-R302.11 > (2" x _ top plate of breaker panel frame out needs to be turned flat and wires drilled through to reduce firestop annular space to 1/2" ). Inspector Notes from Inspection 2460 5/6/27: Check at next inspection. 1). Truss engineering for trusses NF12217 and NF12218 are missing. 9 trusses total at 2 webs. Marked on packet. 5/4/2026 - PREVIOUS INSPECTION NOTES 5/4/26: 1). All truss engineering still needs to be complete. 2). straps on exterior corners above patio roofs are not nailed as required. 3). 2-ply trusses need to be connected at OC measurements as required in truss packet. | |||
| INSULATION | 05/19/2026 | CANCELLED BY APPLICANT | KSANDOE |
| Note: Inspector Notes from Inspection 2420 5/14/26: Check at Insulation. 1). Ufer ground rod needs to be placed in wall to protect from damage. NEC-250.64(B)(2) 2). Fireblocking at top of breaker panel is required. FBC-R302.11 > (2" x _ top plate of breaker panel frame out needs to be turned flat and wires drilled through to reduce firestop annular space to 1/2" ). Inspector Notes from Inspection 2460 5/6/27: Check at next inspection. 1). Truss engineering for trusses NF12217 and NF12218 are missing. 9 trusses total at 2 webs. Marked on packet. 5/4/2026 - PREVIOUS INSPECTION NOTES 5/4/26: 1). All truss engineering still needs to be complete. 2). straps on exterior corners above patio roofs are not nailed as required. 3). 2-ply trusses need to be connected at OC measurements as required in truss packet. | |||
| FIREWALL PENETRATIONS | 05/14/2026 | APPROVED | RSIMS |
| Note: 5/14/26: Visually confirmed there are no penetrations through the firewall. Inspector Notes from Inspection 2460 5/6/27: Check at next inspection. 1). Truss engineering for trusses NF12217 and NF12218 are missing. 9 trusses total at 2 webs. Marked on packet. 5/4/2026 - PREVIOUS INSPECTION NOTES 5/4/26: 1). All truss engineering still needs to be complete. 2). straps on exterior corners above patio roofs are not nailed as required. 3). 2-ply trusses need to be connected at OC measurements as required in truss packet. | |||
| LATH/BRICK/ WATER BARRIER | 05/14/2026 | APPROVED | RSIMS |
| Note: Inspector Notes from Inspection 2460 5/6/27: Check at next inspection. 1). Truss engineering for trusses NF12217 and NF12218 are missing. 9 trusses total at 2 webs. Marked on packet. 5/4/2026 - PREVIOUS INSPECTION NOTES 5/4/26: 1). All truss engineering still needs to be complete. 2). straps on exterior corners above patio roofs are not nailed as required. 3). 2-ply trusses need to be connected at OC measurements as required in truss packet. | |||
| ALL ROUGH | 05/14/2026 | APPROVED - AS NOTED | RSIMS |
| Note: 5/14/26: Check at Insulation. 1). Ufer ground rod needs to be placed in wall to protect from damage. NEC-250.64(B)(2) 2). Fireblocking at top of breaker panel is required. FBC-R302.11 > (2" x _ top plate of breaker panel frame out needs to be turned flat and wires drilled through to reduce firestop annular space to 1/2" ). Inspector Notes from Inspection 2460 5/6/27: Check at next inspection. 1). Truss engineering for trusses NF12217 and NF12218 are missing. 9 trusses total at 2 webs. Marked on packet. 5/4/2026 - PREVIOUS INSPECTION NOTES 5/4/26: 1). All truss engineering still needs to be complete. 2). straps on exterior corners above patio roofs are not nailed as required. 3). 2-ply trusses need to be connected at OC measurements as required in truss packet. | |||
| ELECTRIC-TUG | 05/11/2026 | APPROVED - AS NOTED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 5/11/2026 1:47:45 PM *** 5/11/26: FPL emailed > Approved for TUG. | |||
| FIREWALL FRAMING | 05/06/2026 | APPROVED | RSIMS |
| Note: 5/4/2026 - PREVIOUS INSPECTION NOTES 5/4/26: Partial for front porches only. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 05/06/2026 | APPROVED - AS NOTED | RSIMS |
| Note: 5/6/27: Check at next inspection. 1). Truss engineering for trusses NF12217 and NF12218 are missing. 9 trusses total at 2 webs. Marked on packet. 5/4/2026 - PREVIOUS INSPECTION NOTES 5/4/26: 1). All truss engineering still needs to be complete. 2). straps on exterior corners above patio roofs are not nailed as required. 3). 2-ply trusses need to be connected at OC measurements as required in truss packet. | |||
| ROOF VALLEY & METAL | 05/04/2026 | APPROVED | RSIMS |
| WALL SHEATHING | 05/04/2026 | APPROVED | RSIMS |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 05/04/2026 | PARTIALLY APPROVED | RSIMS |
| Note: 5/4/26: 1). All truss engineering still needs to be complete. 2). straps on exterior corners above patio roofs are not nailed as required. 3). 2-ply trusses need to be connected at OC measurements as required in truss packet. | |||
| FIREWALL FRAMING | 05/04/2026 | PARTIALLY APPROVED | RSIMS |
| Note: 5/4/26: Partial for front porches only. | |||
| MONOLITHIC SLAB | 04/10/2026 | APPROVED | MCONTRYMAN |
| PLUMBING 1ST ROUGH UNDERGROUND | 04/08/2026 | APPROVED | KSANDOE |
| GRAVITY SEWER TEST | 04/07/2026 | APPROVED | KSANDOE |
| SEWER TIE IN | 04/07/2026 | APPROVED | KSANDOE |
| FORMBOARD SURVEY (OFFICE USE ONLY) | 04/06/2026 | APPROVED | DLEAP |
| ELECTRIC - EARLY POWER | |||
| BLD - BUILDING FINAL | |||
| LDSC- LANDSCAPE FINAL | |||
| WATER METER INSTALLATION REQUEST | |||
| U-CROSS CONNECTION | |||
| U -UTILITY RESIDENTIAL FINAL |
Review History
| Department | Status | Date In | Date Out |
| PLENG | COMPLETE | 04/06/2026 | 04/06/2026 |
| Note: Released By: DENNIS R. LEAP, P.E. - (386)986-2482 - DLEAP@PALMCOASTGOV.COM | |||
| PLENG | COMPLETE | 03/30/2026 | 03/31/2026 |
| Note: Released By: DENNIS R. LEAP, P.E. - (386)986-2482 - DLEAP@PALMCOASTGOV.COM | |||
| DSD | COMPLETE | 03/30/2026 | 03/31/2026 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| PLENG | HOLD | 03/20/2026 | 03/24/2026 |
| Note: Held By: DENNIS R. LEAP, P.E. - (386)986-2482 - DLEAP@PALMCOASTGOV.COM 1. Provide Grading Plan. Note: Grading Plan should match the grading per the approved Preliminary Plat Construction Plans. | |||
| DSD | HOLD | 03/20/2026 | 03/24/2026 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Please submit the corrections for the other two addresses so entire building can be released | |||
| PLLA | COMPLETE | 03/20/2026 | 03/27/2026 |
| Note: Released By: RICHARD PICATAGI - (386)986-3760 - RPICATAGI@PALMCOASTGOV.COM | |||
| ARCHR | COMPLETE | 03/05/2026 | 03/12/2026 |
| Note: Released By: RICHARD PICATAGI - (386)986-3760 - RPICATAGI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 03/05/2026 | 03/11/2026 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| DSD | HOLD | 03/05/2026 | 03/09/2026 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Lots incorrect on site plan in description should be Lots 59-62 Please provide walkway width and material Survey has incorrect lot number this is lot 60 | |||
| ELEC | COMPLETE | 03/05/2026 | 03/09/2026 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| FI1 | CANCEL | 03/05/2026 | 03/09/2026 |
| GAS | CANCEL | 03/05/2026 | 03/06/2026 |
| MECH | COMPLETE | 03/05/2026 | 03/09/2026 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| PLENG | HOLD | 03/05/2026 | 03/06/2026 |
| Note: Held By: DENNIS R. LEAP, P.E. - (386)986-2482 - DLEAP@PALMCOASTGOV.COM 1. Provide Grading Plan | |||
| PLLA | HOLD | 03/05/2026 | 03/12/2026 |
| Note: Held By: RICHARD PICATAGI - (386)986-3760 - RPICATAGI@PALMCOASTGOV.COM provide screening at each A/C unit at rear of buildings | |||
| PLUM | COMPLETE | 03/05/2026 | 03/06/2026 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| UD1 | COMPLETE | 03/05/2026 | 03/09/2026 |
| Note: Released By: GREG DEGLER - (386)986-2384 - GDEGLER@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 04/06/2026 |
| INSPECTION - RESIDENTIAL | ¤742.50 | 04/06/2026 |
| PLAN REVIEW - RESIDENTIAL | ¤210.60 | 04/06/2026 |
| FC IMPACT FEE EMS | ¤62.00 | 04/06/2026 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 04/06/2026 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 04/06/2026 |
| FIRE RES IMPACT FEE 10-25 | ¤942.00 | 04/06/2026 |
| PARKS IMPACT FEE 10-25 | ¤3,164.00 | 04/06/2026 |
| SURCHARGE FS 533.721 | ¤9.83 | 04/06/2026 |
| SURCHARGE - FS 468.631 | ¤14.75 | 04/06/2026 |
| TRANSP MULTI IMPACT FEE 10-25 | ¤6,410.82 | 04/06/2026 |
| TRANSP MULTI IMPACT FEE 10-25 | (¤6,410.82) | 04/06/2026 |
| WASTEWATER PERM INSPECTION | ¤80.00 | 04/06/2026 |
| WASTEWATER PERM REVIEW | ¤25.00 | 04/06/2026 |
| WATER PERMIT REVIEW | ¤25.00 | 04/06/2026 |
| SITE PLAN 30 | ¤30.00 | 04/06/2026 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤5,821.68 |