I want to search for...
Permit #2026030332
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7034-00190-0010 |
| Block: 00190 |
| Subdivision: 2165 - SECTION 34-EASTHAMPTON |
| Job Phone: 386-999-1042 |
| Location Address: 16 EAGLE CREST PATH |
| Type: PO - POOL |
| Issue Date: 03/18/2026 |
| NOC: RECORDED |
| Applicant name: RYDER N BRAY |
| Owner: LUIGI BELCASTRO AND IZABELA BELCASTRO |
|
Address 16 EAGLE CREST PATH PALM COAST, FL 32164 |
| Lot: 0010 |
| Contracted Stated Job Value: ¤78,000.00 |
| Job Description: POOL, SCREEN ENCLOSURE |
| Type: CN |
Contractor
HAVEN POOLS LLC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
25 PUTTER LANE PALM COAST, FL 32164 |
CPC1460243 (Exp: 08/31/2026) | 386-999-1042 |
Inspection History
| Type | Request Date | Result | Inspector |
| POOL FINAL | 05/29/2026 | FINAL APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 5/29/2026 9:31:25 AM *** Final Approved | |||
| U -UTILITY RESIDENTIAL FINAL | 05/22/2026 | APPROVED | TLOWE |
| ROW - FINAL INSPECTION | 05/21/2026 | APPROVED | FSLADISH |
| Note: 5/21/26 REQUIRED CORRECTION COMPLETED AT THE TIME OF THIS INSPECTION. 5/14/2026 - PREVIOUS INSPECTION NOTES 5/14/26 PLEASE READ INSPECTORS NOTE. AREA OUTLINED IN PAINT NEEDS TO BE LOWERED TO GRADE ON BOTH SIDES WHERE ORIGINAL GRADE IS TO ALLOW DRAINAGE TO FLOW TO COPC DITCH. _____________________________________________________________________________________________________________________________- Inspector Notes from Inspection 9465 5/13/26 DRAINAGE OVERALL WORKS. THERE IS A HIGH SPOT IN THE FRONT SWALE AS INDICATED ON THE FINAL SURVEY WHERE MACHINE WAS USED FOR ACCESS DURING CONSTUCTION, THIS WILL NEED TO BE LOWERED TO MATCH GRADE AND ALLOW DRAINAGE TO FLOW TO COPC DRAINAGE DITCH. APPROVING THIS INSPECTION AS NOTED. | |||
| ROW - FINAL INSPECTION | 05/14/2026 | Disapproved -FEE REQUIRED | FSLADISH |
| Note: 5/14/26 PLEASE READ INSPECTORS NOTE. AREA OUTLINED IN PAINT NEEDS TO BE LOWERED TO GRADE ON BOTH SIDES WHERE ORIGINAL GRADE IS TO ALLOW DRAINAGE TO FLOW TO COPC DITCH. _____________________________________________________________________________________________________________________________- Inspector Notes from Inspection 9465 5/13/26 DRAINAGE OVERALL WORKS. THERE IS A HIGH SPOT IN THE FRONT SWALE AS INDICATED ON THE FINAL SURVEY WHERE MACHINE WAS USED FOR ACCESS DURING CONSTUCTION, THIS WILL NEED TO BE LOWERED TO MATCH GRADE AND ALLOW DRAINAGE TO FLOW TO COPC DRAINAGE DITCH. APPROVING THIS INSPECTION AS NOTED. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 05/13/2026 | APPROVED | FSLADISH |
| Note: 5/13/26 FINAL SURVEY MEETS MINIMUM COPC STANDARDS. A HIGH SPOT IS SHOWN IN THE FRONT SWALE ON THE LEFT SIDE WILL DETERMINE ON FIELD SURVEY IF THIS IS TRUE. ______________________________________________________________________________________________________________________________ 5/1/2026 - PREVIOUS INSPECTION NOTES 5/1/26 THE FINAL SURVEY YOU HAVE SUBMITTED FOR REVIEW DOES NOT MEET THE COPC MINIMUM STANDARDS. THE LIMITED ELEVATION SHOTS PROVIDED DO NOT INDICATE THE DRAINAGE MATCHES YOUR SITE PLAN AND WILL HAVE POSITIVE FLOW TO THE SWAL.E. 20 FOOT GRID Section 300.01 B(5) V-15 "5) The interior elevations at no greater than a 20-foot grid. • Shots at the corners, along the sides, rear of the building, and 10 feet off of the building are required in addition to the 20-foot grid." FFE ADJACENT PROPERTY Section 300.01 B(3) V-15 3) The elevations on all adjacent properties at a minimum of 20-foot intervals on a 10-foot offset outside the property lines. Finished Floor Elevations (FFE): Section 300.01 B(2) V-15 Finished Floor Elevations (FFE): 2) Finished Floor Elevation (FFE) of the living area of all improved structures on adjacent properties. REAR YARD DRAINAGE Section 300.01 C(6) V-16 "6) Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale, unless the Topographic Survey/Lot Grading Plan demonstrates a rear yard drainage system with an appropriate outfall. Draining onto adjacent properties will not be allowed outside of the platted 5’ drainage easement." SEE PHOTO FOR REFERENCE. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 05/13/2026 | APPROVED - AS NOTED | FSLADISH |
| Note: 5/13/26 DRAINAGE OVERALL WORKS. THERE IS A HIGH SPOT IN THE FRONT SWALE AS INDICATED ON THE FINAL SURVEY WHERE MACHINE WAS USED FOR ACCESS DURING CONSTUCTION, THIS WILL NEED TO BE LOWERED TO MATCH GRADE AND ALLOW DRAINAGE TO FLOW TO COPC DRAINAGE DITCH. APPROVING THIS INSPECTION AS NOTED. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 05/01/2026 | Disapproved - NO FEE | FSLADISH |
| Note: 5/1/26 THE FINAL SURVEY YOU HAVE SUBMITTED FOR REVIEW DOES NOT MEET THE COPC MINIMUM STANDARDS. THE LIMITED ELEVATION SHOTS PROVIDED DO NOT INDICATE THE DRAINAGE MATCHES YOUR SITE PLAN AND WILL HAVE POSITIVE FLOW TO THE SWAL.E. 20 FOOT GRID Section 300.01 B(5) V-15 "5) The interior elevations at no greater than a 20-foot grid. • Shots at the corners, along the sides, rear of the building, and 10 feet off of the building are required in addition to the 20-foot grid." FFE ADJACENT PROPERTY Section 300.01 B(3) V-15 3) The elevations on all adjacent properties at a minimum of 20-foot intervals on a 10-foot offset outside the property lines. Finished Floor Elevations (FFE): Section 300.01 B(2) V-15 Finished Floor Elevations (FFE): 2) Finished Floor Elevation (FFE) of the living area of all improved structures on adjacent properties. REAR YARD DRAINAGE Section 300.01 C(6) V-16 "6) Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale, unless the Topographic Survey/Lot Grading Plan demonstrates a rear yard drainage system with an appropriate outfall. Draining onto adjacent properties will not be allowed outside of the platted 5’ drainage easement." SEE PHOTO FOR REFERENCE. | |||
| ELECTRIC AND ALARM | 04/17/2026 | APPROVED | HCAMACHO |
| ELECTRIC AND ALARM | 04/16/2026 | CANCELLED BY APPLICANT | WEB |
| POOL DECK | 03/30/2026 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 3/30/2026 12:51:05 PM *** Approved | |||
| STEEL AND GROUND | 03/19/2026 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 3/19/2026 12:39:12 PM *** Approved |
Review History
| Department | Status | Date In | Date Out |
| BFLOOD | CANCEL | 03/10/2026 | 03/11/2026 |
| BLD | COMPLETE | 03/10/2026 | 03/17/2026 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 03/10/2026 | 03/16/2026 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 03/10/2026 | 03/11/2026 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| RSI | COMPLETE | 03/10/2026 | 03/17/2026 |
| Note: Released By: TOM POLACEK - (386)346-8986 - ALL DRAINAGE FOR PROPERTY MUST MEET ALL COPC MINIMUM STANDARDS AT THE COMPLETION OF PROJECT | |||
| ZON | COMPLETE | 03/10/2026 | 03/11/2026 |
| Note: Released By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| RSI REINSPECTION 1 | ¤35.00 | 05/28/2026 |
| RSI ROW FINAL INSPECTION | ¤16.25 | 03/18/2026 |
| SURCHARGE FS 533.721 | ¤2.55 | 03/18/2026 |
| SURCHARGE - FS 468.631 | ¤3.83 | 03/18/2026 |
| SITE PLAN 30 | ¤30.00 | 03/18/2026 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 03/18/2026 |
| INSPECTION- POOL | ¤160.00 | 03/18/2026 |
| PLAN REVIEW - RESIDENTIAL | ¤65.00 | 03/18/2026 |
| RSI FIELD SURVEY INSPECTION | ¤48.75 | 03/18/2026 |
| RSI PLAN REVIEW NEW | ¤48.75 | 03/18/2026 |
| RSI FNL SURVEY/GRADING CERT | ¤48.75 | 03/18/2026 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤488.88 |