I want to search for...
Permit #2026030481
Permit Details
Status: INSPECT
| Parcel Id: 04-11-30-5571-00000-3630 |
| CONDITIONED SPACE: 1501 sqft |
| GARAGE: 419 sqft |
| OPENED PORCH (WITH ROOF) : 72 sqft |
| OPENED PORCH (WITH ROOF) : 115 sqft |
| Total Square Footage: 2107 sqft |
| Subdivision: 2366 - SOMERSET SUBDIVISION PH 2 |
| Job Phone: 904-596-6645 |
| Location Address: 96 GOLDEN BELL AVE |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 03/26/2026 |
| NOC: RECORDED |
| Applicant name: MICHAEL T HOLDER |
| Owner: KB HOME JACKSONVILLE LLC |
|
Address 10475 FORTUNE PARKWAY JACKSONVILLE, FL 32256 |
|
Address SUITE 100 JACKSONVILLE, FL 32256 |
| Lot: 363 |
| Contracted Stated Job Value: ¤140,000.00 |
| Job Description: Single Family Residence |
| Type: CN |
Contractor
KB HOME JACKSONVILLE, LLC
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
10475 FORTUNE PKWY JACKSONVILLE, FL 32256 |
SUITE 100 JACKSONVILLE, FL 32256 |
CGC1509034 (Exp: 08/31/2026) | 904-596-6645 |
Sub Contractors
LARRY WILLIAMS
| Status | Location Address | State License Number | Phone |
| ACTIVE |
1750 EMERSON ST JACKSONVILLE, FL 32207 |
LI45034 (Exp: 08/31/2026) | 904-721-5431 |
BOBBY WAYNE CAMPBELL
| Status | Location Address | State License Number | Phone |
| ACTIVE |
117 GUTHRIE ROAD GREEN COVE SPRINGS, FL 32043 |
CCC1326752 (Exp: 08/31/2026) | 904-200-1600 |
JAMES E LINTON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
200 COLLEGE DR ORANGE PARK, FL 32065 |
EC0001152 (Exp: 08/31/2026) | 904-272-0272 |
COREY MICHAEL TENNANT
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3370 AGRICULTURAL CNETER DR ST AUGUSTINE, FL 32092 |
CAC1819063 (Exp: 08/31/2026) | 904-829-8898 |
BENJAMIN MICHAEL RAY
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| ACTIVE |
6310 MABLETON PKWY JACKSONVILLE, FL 32216 |
SUITE 1000 MABLETON, GA 30126 |
CFC1428415 (Exp: 08/31/2026) | 904-861-5421 | 904-861-5426 |
Inspection History
| Type | Request Date | Result | Inspector |
| ELECTRIC - EARLY POWER | 06/08/2026 | APPROVED | JSTEWART |
| Note: Inspector Notes from Inspection 2200 Authorize release of email. | |||
| ROW- PRE-APRON (PRE-POUR) | 05/19/2026 | APPROVED - AS NOTED | PFLANAGAN |
| Note: PLEASE FIX RIGHT SIDEWALK IT IS PITCHING TO THE HOUSE PLEASE PITCH TOWARDS THE ROAD PASSING AS NOTED THAT YOU WILL FIX ISSUE BEFORE POURING. IF SIDEWALK IS PITCHED AT AFTER POUR THEN WILL NEED TO BE RIPPED OUT AND REPAIRED IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE. ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS. | |||
| DRYWALL NAILING | 05/11/2026 | APPROVED | JSTEWART |
| INSULATION | 05/07/2026 | APPROVED | JSTEWART |
| Note: 5/4/2026 - PREVIOUS INSPECTION NOTES 1. Please firestop the top of the electric panel Chase. FBC R302.11(4) 2. Batt insulation is to short (edge of interior wall /or/ only covers 1" of the exterior wall top plate) FBEC R402.2.1 Ceilings with attics. | |||
| INSULATION | 05/04/2026 | Disapproved - NO FEE | JSTEWART |
| Note: 1. Please firestop the top of the electric panel Chase. FBC R302.11(4) 2. Batt insulation is to short (edge of interior wall /or/ only covers 1" of the exterior wall top plate) FBEC R402.2.1 Ceilings with attics. | |||
| LATH/BRICK/ WATER BARRIER | 04/30/2026 | APPROVED | JSTEWART |
| Note: Inspector Notes from Inspection 2450 Inspector Notes from Inspection 2460 1. Gable brace in garage needs to be nailed tight to blocking (Large gap). 2. Front porch post needs installed (2x temp), and strapped. will check at next inspection. | |||
| ALL ROUGH | 04/30/2026 | APPROVED - AS NOTED | JSTEWART |
| Note: 1. please secure plumbing to framing member at both hose bibbs. 2. Please seal dryer duct at roof penetration. 3. water preassure test to low. Will check at insulation. Inspector Notes from Inspection 2450 Inspector Notes from Inspection 2460 1. Gable brace in garage needs to be nailed tight to blocking (Large gap). 2. Front porch post needs installed (2x temp), and strapped. will check at next inspection. | |||
| ELECTRIC-TUG | 04/30/2026 | APPROVED - AS NOTED | JSTEWART |
| Note: Authorize release of email. | |||
| WALL SHEATHING | 04/27/2026 | APPROVED - AS NOTED | JSTEWART |
| Note: Inspector Notes from Inspection 2460 1. Gable brace in garage needs to be nailed tight to blocking (Large gap). 2. Front porch post needs installed (2x temp), and strapped. will check at next inspection. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 04/23/2026 | APPROVED - AS NOTED | JSTEWART |
| Note: 1. Gable brace in garage needs to be nailed tight to blocking (Large gap). 2. Front porch post needs installed (2x temp), and strapped. will check at next inspection. | |||
| ROOF VALLEY & METAL | 04/23/2026 | APPROVED - AS NOTED | JSTEWART |
| WALL SHEATHING | 04/23/2026 | Disapproved - NO FEE | JSTEWART |
| Note: Please nail seam at master bath window. aprox 48" long. | |||
| GRAVITY SEWER TEST | 04/21/2026 | APPROVED | JSTEWART |
| Note: Inspector Notes from Inspection 2060 Main water supply from Ultility connection to house shut off not installed, will need to be installed prior to Sewer tie in /or/ All rough, and open for inspection. | |||
| SEWER TIE IN | 04/21/2026 | APPROVED | JSTEWART |
| Note: Inspector Notes from Inspection 2060 Main water supply from Ultility connection to house shut off not installed, will need to be installed prior to Sewer tie in /or/ All rough, and open for inspection. | |||
| MONOLITHIC SLAB | 04/10/2026 | APPROVED | JSTEWART |
| Note: 4/9/2026 - PREVIOUS INSPECTION NOTES 4/6/2026 - PREVIOUS INSPECTION NOTES Left side of garage footing Is at a depth of 19" +/-, According to Grade and draninage plan the front of the building will have 9.6 inches of foundation above the finish grade requireing footing depth to be min 22" deep from top of forms, to maintain the required min 12" of footing below finish grade. FBC R403.1.4 . FFE 39.10, grade elevation 38.30 (39.10 - 38.30 = 0.80 feet / 0.80X12=9.6 inches. | |||
| MONOLITHIC SLAB | 04/09/2026 | CANCELLED BY APPLICANT | JSTEWART |
| Note: 4/6/2026 - PREVIOUS INSPECTION NOTES Left side of garage footing Is at a depth of 19" +/-, According to Grade and draninage plan the front of the building will have 9.6 inches of foundation above the finish grade requireing footing depth to be min 22" deep from top of forms, to maintain the required min 12" of footing below finish grade. FBC R403.1.4 . FFE 39.10, grade elevation 38.30 (39.10 - 38.30 = 0.80 feet / 0.80X12=9.6 inches. | |||
| MONOLITHIC SLAB | 04/06/2026 | Disapproved - NO FEE | JSTEWART |
| Note: Left side of garage footing Is at a depth of 19" +/-, According to Grade and draninage plan the front of the building will have 9.6 inches of foundation above the finish grade requireing footing depth to be min 22" deep from top of forms, to maintain the required min 12" of footing below finish grade. FBC R403.1.4 . FFE 39.10, grade elevation 38.30 (39.10 - 38.30 = 0.80 feet / 0.80X12=9.6 inches. | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 04/02/2026 | APPROVED - AS NOTED | JSTEWART |
| Note: Main water supply from Ultility connection to house shut off not installed, will need to be installed prior to Sewer tie in /or/ All rough, and open for inspection. | |||
| WATER METER INSTALLATION REQUEST | 04/02/2026 | APPROVED | ISANDERSON |
| FORMBOARD SURVEY (OFFICE USE ONLY) | 03/31/2026 | APPROVED | PFLANAGAN |
| BLD - BUILDING FINAL | |||
| U-CROSS CONNECTION | |||
| ROW - FINAL APRON (AFTER POUR) | |||
| ROW - FINAL INSPECTION | |||
| U -UTILITY RESIDENTIAL FINAL |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 03/30/2026 | 03/31/2026 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 03/30/2026 | 03/30/2026 |
| Note: Released By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 03/12/2026 | 03/19/2026 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 03/12/2026 | 03/17/2026 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 03/12/2026 | 03/16/2026 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 03/12/2026 | 03/13/2026 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| GAS | COMPLETE | 03/12/2026 | 03/13/2026 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 03/12/2026 | 03/13/2026 |
| Note: Released By: IVAN SANDERSON - - | |||
| MECH | COMPLETE | 03/12/2026 | 03/16/2026 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 03/12/2026 | 03/13/2026 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 03/12/2026 | 03/13/2026 |
| Note: Released By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM | |||
| URB | COMPLETE | 03/12/2026 | 03/13/2026 |
| Note: Released By: JOHN BEAUDET - (386)986-2456 - JBEAUDET@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| WATER-METER | ¤874.47 | 03/26/2026 |
| WATER- TURN ON | ¤50.00 | 03/26/2026 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 03/26/2026 |
| INSPECTION - RESIDENTIAL | ¤822.25 | 03/26/2026 |
| PLAN REVIEW - RESIDENTIAL | ¤233.22 | 03/26/2026 |
| FC IMPACT FEE EMS | ¤62.00 | 03/26/2026 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 03/26/2026 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 03/26/2026 |
| FIRE RES IMPACT FEE 10-25 | ¤942.00 | 03/26/2026 |
| WATER METER W/OUT TAP | ¤965.03 | 03/26/2026 |
| PARKS IMPACT FEE 10-25 | ¤3,164.00 | 03/26/2026 |
| RECLAIM WATER PERMIT INSPECTIO | ¤40.00 | 03/26/2026 |
| RSI DRIVEWAY AFTER POUR | ¤16.25 | 03/26/2026 |
| RSE DRIVE PRE POUR INSPECTION | ¤32.50 | 03/26/2026 |
| RSI FIELD SURVEY INSPECTION | ¤48.75 | 03/26/2026 |
| RSI FORMBOARD REVIEW | ¤16.25 | 03/26/2026 |
| RSI PLAN REVIEW NEW | ¤48.75 | 03/26/2026 |
| RSI FNL SURVEY/GRADING CERT | ¤48.75 | 03/26/2026 |
| RSI ROW FINAL INSPECTION | ¤16.25 | 03/26/2026 |
| SCHOOL BOARD IMPACT FEE RES | ¤5,450.00 | 03/26/2026 |
| SURCHARGE FS 533.721 | ¤10.85 | 03/26/2026 |
| SURCHARGE - FS 468.631 | ¤16.28 | 03/26/2026 |
| TRANSP RES IMPACT FEE 10-25 | ¤5,658.77 | 03/26/2026 |
| WASTEWATER PERM INSPECTION | ¤80.00 | 03/26/2026 |
| WASTEWATER PERM REVIEW | ¤25.00 | 03/26/2026 |
| SEWER CAPITAL FACILITY | ¤3,628.86 | 03/26/2026 |
| WATER CAPITAL FACILITY FEE | ¤3,091.14 | 03/26/2026 |
| WATER PERMIT REVIEW | ¤25.00 | 03/26/2026 |
| SITE PLAN 30 | ¤30.00 | 03/26/2026 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤25,912.37 |