I want to search for...

Permit #2026030779

Permit Details

Status: INSPECT

Parcel Id: 21-12-31-5560-00000-1360
CONDITIONED SPACE: 1815 sqft
GARAGE: 432 sqft
OPENED PORCH (WITH ROOF) : 142 sqft
Total Square Footage: 2389 sqft
Subdivision: 2336 - SEMINOLE PALMS SUBDIVISION PHASE 1
Job Phone: 407-717-5418
Location Address: 277 MONTGOMERY CT
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 04/14/2026
NOC: RECORDED
Applicant name: CARLOS ANTONIO SERRANO
Owner: NVR INC

Address

1409 TECH BLVD

TAMPA, FL 33619

Address

SUITE 202

TAMPA, FL 33619

Lot: 136
Contracted Stated Job Value: ¤172,215.00
Job Description: SINGLE FAMILY HOME
Type: CN

Contractor

RYAN HOMES
Status Location Address Mailing Address State License Number Phone
ACTIVE

8649 BAYPINE RD

JACKSONVILLE, FL 32256

BLDG 7, STE 202

JACKSONVILLE, FL 32256

CBC1256450 (Exp: 08/31/2026) 407-717-5418

Sub Contractors

JOSEPH H STRADA JR
Status Location Address State License Number Phone
ACTIVE

3400 ST JOHNS PKWY

SANFORD, FL 32771

CAC043953 (Exp: 08/31/2026) 877-906-1113
JOSEPH H STRADA JR
Status Location Address State License Number Phone
ACTIVE

3400 ST JOHNS PKWY

SANFORD, FL 32771

CAC043953 (Exp: 08/31/2026) 877-906-1113
JACK DOUGLAS LANIER
Status Location Address State License Number Phone Fax
ACTIVE

485 COMMERCE WAY

LONGWOOD , FL 32750

CCC058022 (Exp: 08/31/2026) (321)441-2300 (321)441-2313
BRITT MICHAEL JENKINS
Status Location Address State License Number Phone
ACTIVE

86 COLUMBIA DR

POOLER, GA 31322

CFC1430770 (Exp: 08/31/2026) 912-330-8151

Inspection History

Type Request Date Result Inspector
ROW- PRE-APRON (PRE-POUR) 06/04/2026 APPROVED FSLADISH
Note: 6/4/26 AT THE TIME OF THE INSPECTION PREPOUR AREA IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD REMOVE ALL WATER AND CHECK COMPACTION BEFORE POURING CONCRETE. 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED IS REQUIRED. PLEASE REVIEW CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. NO EXPANSION JOINTS ALLOWED.
ALL ROUGH 05/26/2026 APPROVED RSIMS
DRYWALL NAILING 05/21/2026 APPROVED RSIMS
INSULATION 05/19/2026 APPROVED RSIMS
Note: 5/18/2026 - PREVIOUS INSPECTION NOTES 5/18/26: 1). 5ft head pressure is not holding. Noted on previous inspections. FBC-P2503.5.1 > PLEASE FILL PIPE TO TOP FOR INSPECTION. (water level in pipe is down significantly from previous inspection). 2). Front entry door needs foam seal along top jamb. 3). Primary bathroom: hole in slab where 2" PVC piupe penetrates for vainty drains needs to be repaired with concrete. (Please remove dirt down to thickness of slab prior to repairing). FBCR 318 4). Guest bathroom on left: Pipe sleeve for tub drain needs to be filled with concrete. FBCR 318 Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 5/14/2026 12:11:37 PM *** 5/14/26: Check at Insulation. Previously listed items: 2). No 5ft head pressure. FBC-P2503.5.1 > PLEASE FILL PIPE TO TOP FOR INSPECTION. 3). Front entry door has shim space that exceeds the 1/4" maximum and will require solid shim. (includes top jamb). FBCR 609.1 Re-inspection items: 1). Fireblocking at top of breaker panel is required. FBC-R302.11 > (2" x _ top plate of breaker panel frame out needs to be turned flat and wires drilled through to reduce firestop annular space to 1/2" ). 2). Primary bedroom: smoke detector needs to be moved as far away from the ceiling fan as possible to meet NFPA72-29.11.3.4 Specific location requirements. (9) Smoke alarms and smoke detectors shall not be installed within a 36-inch (910 mm) horizontal path from the tip of the blade of a ceiling-suspended (paddle) fan unless the room configuration restricts meeting this requirement. ------------------------------------------------------------------------------------------------------------------------------ 5/13/2026 - PREVIOUS INSPECTION NOTES 5/13/26: 1). Electrician still working on wiring in garage, etc. FBC [A]107.4 - Not ready 2). No 5ft head pressure. FBC-P2503.5.1 3). Front entry door has shim space that exceeds the 1/4" maximum and will require solid shim. (includes top jamb). FBCR 609.1
INSULATION 05/18/2026 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 5/18/2026 1:23:23 PM *** 5/18/26: 1). 5ft head pressure is not holding. Noted on previous inspections. FBC-P2503.5.1 > PLEASE FILL PIPE TO TOP FOR INSPECTION. (water level in pipe is down significantly from previous inspection). 2). Front entry door needs foam seal along top jamb. 3). Primary bathroom: hole in slab where 2" PVC piupe penetrates for vainty drains needs to be repaired with concrete. (Please remove dirt down to thickness of slab prior to repairing). FBCR 318 4). Guest bathroom on left: Pipe sleeve for tub drain needs to be filled with concrete. FBCR 318 Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 5/14/2026 12:11:37 PM *** 5/14/26: Check at Insulation. Previously listed items: 2). No 5ft head pressure. FBC-P2503.5.1 > PLEASE FILL PIPE TO TOP FOR INSPECTION. 3). Front entry door has shim space that exceeds the 1/4" maximum and will require solid shim. (includes top jamb). FBCR 609.1 Re-inspection items: 1). Fireblocking at top of breaker panel is required. FBC-R302.11 > (2" x _ top plate of breaker panel frame out needs to be turned flat and wires drilled through to reduce firestop annular space to 1/2" ). 2). Primary bedroom: smoke detector needs to be moved as far away from the ceiling fan as possible to meet NFPA72-29.11.3.4 Specific location requirements. (9) Smoke alarms and smoke detectors shall not be installed within a 36-inch (910 mm) horizontal path from the tip of the blade of a ceiling-suspended (paddle) fan unless the room configuration restricts meeting this requirement. ------------------------------------------------------------------------------------------------------------------------------ 5/13/2026 - PREVIOUS INSPECTION NOTES 5/13/26: 1). Electrician still working on wiring in garage, etc. FBC [A]107.4 - Not ready 2). No 5ft head pressure. FBC-P2503.5.1 3). Front entry door has shim space that exceeds the 1/4" maximum and will require solid shim. (includes top jamb). FBCR 609.1
LATH/BRICK/ WATER BARRIER 05/18/2026 APPROVED RSIMS
Note: Inspector Notes from Inspection 2420 *** NOTES ADDED BY RSIMS 5/14/2026 12:11:37 PM *** 5/14/26: Check at Insulation. Previously listed items: 2). No 5ft head pressure. FBC-P2503.5.1 > PLEASE FILL PIPE TO TOP FOR INSPECTION. 3). Front entry door has shim space that exceeds the 1/4" maximum and will require solid shim. (includes top jamb). FBCR 609.1 Re-inspection items: 1). Fireblocking at top of breaker panel is required. FBC-R302.11 > (2" x _ top plate of breaker panel frame out needs to be turned flat and wires drilled through to reduce firestop annular space to 1/2" ). 2). Primary bedroom: smoke detector needs to be moved as far away from the ceiling fan as possible to meet NFPA72-29.11.3.4 Specific location requirements. (9) Smoke alarms and smoke detectors shall not be installed within a 36-inch (910 mm) horizontal path from the tip of the blade of a ceiling-suspended (paddle) fan unless the room configuration restricts meeting this requirement. ------------------------------------------------------------------------------------------------------------------------------ 5/13/2026 - PREVIOUS INSPECTION NOTES 5/13/26: 1). Electrician still working on wiring in garage, etc. FBC [A]107.4 - Not ready 2). No 5ft head pressure. FBC-P2503.5.1 3). Front entry door has shim space that exceeds the 1/4" maximum and will require solid shim. (includes top jamb). FBCR 609.1
ALL ROUGH 05/14/2026 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 5/14/2026 12:11:37 PM *** 5/14/26: Check at Insulation. Previously listed items: 2). No 5ft head pressure. FBC-P2503.5.1 > PLEASE FILL PIPE TO TOP FOR INSPECTION. 3). Front entry door has shim space that exceeds the 1/4" maximum and will require solid shim. (includes top jamb). FBCR 609.1 Re-inspection items: 1). Fireblocking at top of breaker panel is required. FBC-R302.11 > (2" x _ top plate of breaker panel frame out needs to be turned flat and wires drilled through to reduce firestop annular space to 1/2" ). 2). Primary bedroom: smoke detector needs to be moved as far away from the ceiling fan as possible to meet NFPA72-29.11.3.4 Specific location requirements. (9) Smoke alarms and smoke detectors shall not be installed within a 36-inch (910 mm) horizontal path from the tip of the blade of a ceiling-suspended (paddle) fan unless the room configuration restricts meeting this requirement. ------------------------------------------------------------------------------------------------------------------------------ 5/13/2026 - PREVIOUS INSPECTION NOTES 5/13/26: 1). Electrician still working on wiring in garage, etc. FBC [A]107.4 - Not ready 2). No 5ft head pressure. FBC-P2503.5.1 3). Front entry door has shim space that exceeds the 1/4" maximum and will require solid shim. (includes top jamb). FBCR 609.1
ALL ROUGH 05/13/2026 Disapproved - NO FEE RSIMS
Note: 5/13/26: 1). Electrician still working on wiring in garage, etc. FBC [A]107.4 - Not ready 2). No 5ft head pressure. FBC-P2503.5.1 3). Front entry door has shim space that exceeds the 1/4" maximum and will require solid shim. (includes top jamb). FBCR 609.1
ELECTRIC-TUG 05/05/2026 APPROVED - AS NOTED KSANDOE
Note: Release Power
ROOF SHEATHING / BRACES/TIES/DOWN CELL 04/30/2026 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 4/30/2026 12:11:28 PM *** Approved
ROOF VALLEY & METAL 04/30/2026 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 4/30/2026 12:12:58 PM *** Approved
WALL SHEATHING 04/29/2026 APPROVED KSANDOE
MONOLITHIC SLAB 04/22/2026 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 4/22/2026 11:50:05 AM *** Approved
PLUMBING 1ST ROUGH UNDERGROUND 04/20/2026 APPROVED KSANDOE
GRAVITY SEWER TEST 04/20/2026 APPROVED KSANDOE
Note: New inspection due to canceled inspection 4/16/2026 - PREVIOUS INSPECTION NOTES 4/16/26: 1). Dirt and water in the hole at sewer tie-in. Need to be able to see the sewer lateral connection. FBC-P2503.4 2). No head pressure on drain line. FBC-P2503.4 / FBC-P2503.5.1
SEWER TIE IN 04/20/2026 APPROVED KSANDOE
Note: New inspection due to canceled inspection 4/16/2026 - PREVIOUS INSPECTION NOTES 4/16/26: 1). Dirt and water in the hole at sewer tie-in. Need to be able to see the sewer lateral connection. FBC-P2503.4 2). No head pressure on drain line. FBC-P2503.4 / FBC-P2503.5.1
FORMBOARD SURVEY (OFFICE USE ONLY) 04/17/2026 APPROVED RRICKS
GRAVITY SEWER TEST 04/17/2026 CANCELLED BY APPLICANT WEB
Note: 4/16/2026 - PREVIOUS INSPECTION NOTES 4/16/26: 1). Dirt and water in the hole at sewer tie-in. Need to be able to see the sewer lateral connection. FBC-P2503.4 2). No head pressure on drain line. FBC-P2503.4 / FBC-P2503.5.1
SEWER TIE IN 04/17/2026 CANCELLED BY APPLICANT WEB
Note: 4/16/2026 - PREVIOUS INSPECTION NOTES 4/16/26: 1). Dirt and water in the hole at sewer tie-in. Need to be able to see the sewer lateral connection. FBC-P2503.4 2). No head pressure on drain line. FBC-P2503.4 / FBC-P2503.5.1
GRAVITY SEWER TEST 04/16/2026 Disapproved - NO FEE RSIMS
Note: *** NOTES ADDED BY RSIMS 4/16/2026 3:06:44 PM *** 4/16/26: 1). Dirt and water in the hole at sewer tie-in. Need to be able to see the sewer lateral connection. FBC-P2503.4 2). No head pressure on drain line. FBC-P2503.4 / FBC-P2503.5.1
SEWER TIE IN 04/16/2026 Disapproved - NO FEE RSIMS
Note: *** NOTES ADDED BY RSIMS 4/16/2026 3:06:08 PM *** 4/16/26: 1). Dirt and water in the hole at sewer tie-in. Need to be able to see the sewer lateral connection. FBC-P2503.4 2). No head pressure on drain line. FBC-P2503.4 / FBC-P2503.5.1
WATER METER INSTALLATION REQUEST 04/16/2026 APPROVED ISANDERSON
U-CROSS CONNECTION
BLD - BUILDING FINAL
ROW - FINAL APRON (AFTER POUR)
ROW- FINAL SURVEY/GRADING CERTIFICATION
Note: 4/10/26 RRicks Not to inspector. This alot is approved with 0.2' to the rear yard drainage swale due to there are no improvable homes behind. If there are any questions please call Rodney.
ROW - FINAL INSPECTION
U -UTILITY RESIDENTIAL FINAL
ELECTRIC - EARLY POWER

Review History

Department Status Date In Date Out
SW1 COMPLETE 04/16/2026 04/17/2026
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 04/16/2026 04/16/2026
Note: Released By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM
ZON COMPLETE 04/10/2026 04/10/2026
Note: Released By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM
MECH COMPLETE 04/10/2026 04/13/2026
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 04/10/2026 04/10/2026
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
BLD COMPLETE 03/19/2026 03/24/2026
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
CUSVC COMPLETE 03/19/2026 03/25/2026
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 03/19/2026 03/26/2026
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 03/19/2026 03/20/2026
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
GAS CANCEL 03/19/2026 03/20/2026
LOCATE COMPLETE 03/19/2026 03/24/2026
Note: Released By: IVAN SANDERSON - -
MECH HOLD 03/19/2026 03/23/2026
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Plans say wood frame with R13 insulation, Energy calcs show CMU with 4.1 insulation. Revise to match Provide updated state card when resubmitting
SW1 HOLD 03/19/2026 03/25/2026
Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM There shall be a minimum of 0.3' fall from the back property line to the rear yard drainage swale per Technical Manual Section 200.01A.1.b.(17). Please revise as needed.
ZON HOLD 03/19/2026 03/20/2026
Note: Held By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM Color material sheet accent color not checked.
URB COMPLETE 03/19/2026 03/24/2026
Note: Released By: JOHN BEAUDET - (386)986-2456 - JBEAUDET@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
FC IMPACT FEE EMS ¤62.00 04/14/2026
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 04/14/2026
FC IMPACT FEE LIBRARY ¤268.00 04/14/2026
FIRE RES IMPACT FEE 10-25 ¤942.00 04/14/2026
WATER METER W/OUT TAP ¤965.03 04/14/2026
PARKS IMPACT FEE 10-25 ¤3,164.00 04/14/2026
RECLAIM WATER PERMIT INSPECTIO ¤40.00 04/14/2026
RSI DRIVEWAY AFTER POUR ¤16.25 04/14/2026
RSE DRIVE PRE POUR INSPECTION ¤32.50 04/14/2026
RSI FIELD SURVEY INSPECTION ¤48.75 04/14/2026
RSI FORMBOARD REVIEW ¤16.25 04/14/2026
RSI PLAN REVIEW NEW ¤48.75 04/14/2026
RSI FNL SURVEY/GRADING CERT ¤48.75 04/14/2026
RSI ROW FINAL INSPECTION ¤16.25 04/14/2026
SURCHARGE FS 533.721 ¤12.66 04/14/2026
SURCHARGE - FS 468.631 ¤18.98 04/14/2026
TRANSP RES IMPACT FEE 10-25 ¤6,842.55 04/14/2026
TRANSP RES IMPACT FEE 10-25 (¤6,842.55) 04/14/2026
WASTEWATER PERM INSPECTION ¤80.00 04/14/2026
WASTEWATER PERM REVIEW ¤25.00 04/14/2026
SEWER CAPITAL FACILITY ¤2,368.69 04/14/2026
WATER CAPITAL FACILITY FEE ¤1,744.18 04/14/2026
WATER PERMIT REVIEW ¤25.00 04/14/2026
SITE PLAN 30 ¤30.00 04/14/2026
WATER-METER ¤874.47 04/14/2026
WATER- TURN ON ¤50.00 04/14/2026
ADMINISTRATIVE RESIDENTIAL ¤30.00 04/14/2026
INSPECTION - RESIDENTIAL ¤962.50 04/14/2026
PLAN REVIEW - RESIDENTIAL ¤273.00 04/14/2026
REINSPECTION RESIDENTIAL ¤40.00
Fees Total Due: ¤40.00 Total Paid: ¤12,381.01