I want to search for...

Permit #2026030780

Permit Details

Status: INSPECT

Parcel Id: 21-12-31-5560-00000-0930
CONDITIONED SPACE: 2021 sqft
GARAGE: 439 sqft
OPENED PORCH (WITH ROOF) : 124 sqft
Total Square Footage: 2584 sqft
Subdivision: 2336 - SEMINOLE PALMS SUBDIVISION PHASE 1
Job Phone: 407-717-5418
Location Address: 129 SAGO CT
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 05/01/2026
NOC: RECORDED
Applicant name: CARLOS ANTONIO SERRANO
Owner: NVR INC

Address

1409 TECH BLVD

TAMPA, FL 33619

Address

SUITE 202

TAMPA, FL 33619

Lot: 93
Contracted Stated Job Value: ¤185,818.00
Job Description: SINGLE FAMILY HOME
Type: CN

Contractor

RYAN HOMES
Status Location Address Mailing Address State License Number Phone
ACTIVE

8649 BAYPINE RD

JACKSONVILLE, FL 32256

BLDG 7, STE 202

JACKSONVILLE, FL 32256

CBC1256450 (Exp: 08/31/2026) 407-717-5418

Sub Contractors

JOSEPH H STRADA JR
Status Location Address State License Number Phone
ACTIVE

3400 ST JOHNS PKWY

SANFORD, FL 32771

CAC043953 (Exp: 08/31/2026) 877-906-1113
JOSEPH H STRADA JR
Status Location Address State License Number Phone
ACTIVE

3400 ST JOHNS PKWY

SANFORD, FL 32771

CAC043953 (Exp: 08/31/2026) 877-906-1113
JACK DOUGLAS LANIER
Status Location Address State License Number Phone Fax
ACTIVE

485 COMMERCE WAY

LONGWOOD , FL 32750

CCC058022 (Exp: 08/31/2026) (321)441-2300 (321)441-2313
BRITT MICHAEL JENKINS
Status Location Address State License Number Phone
ACTIVE

86 COLUMBIA DR

POOLER, GA 31322

CFC1430770 (Exp: 08/31/2026) 912-330-8151

Inspection History

Type Request Date Result Inspector
LATH/BRICK/ WATER BARRIER 06/12/2026 RSIMS
ALL ROUGH 06/12/2026 RSIMS
Note: 6/10/2026 - PREVIOUS INSPECTION NOTES 6/10/26: Previously listed item 1 remains unresolved. 1). Truss 12025 needs a strap. FBC [A]107.4 2). Main water service underground pipe needs to be exposed and pressurized for inspection. 3). Front door: anchors are not installed and shim spacing exceeds 1/4" and will require solid blocking. FBCR 609.1 Inspector Notes from Inspection 2460 6/8/26: Check at next inspection. 1). Truss 12025 needs a strap. FBC [A]107.4 2). Back wall of house: AB (or Titan) missing within 8" of splice FBC [A]107.4 6/1/26: Roof sheathing inspected and approved.
ALL ROUGH 06/10/2026 Disapproved - NO FEE RSIMS
Note: 6/10/26: Previously listed item 1 remains unresolved. 1). Truss 12025 needs a strap. FBC [A]107.4 2). Main water service underground pipe needs to be exposed and pressurized for inspection. 3). Front door: anchors are not installed and shim spacing exceeds 1/4" and will require solid blocking. FBCR 609.1 Inspector Notes from Inspection 2460 6/8/26: Check at next inspection. 1). Truss 12025 needs a strap. FBC [A]107.4 2). Back wall of house: AB (or Titan) missing within 8" of splice FBC [A]107.4 6/1/26: Roof sheathing inspected and approved.
ELECTRIC-TUG 06/09/2026 APPROVED RMARTIN
ROOF SHEATHING / BRACES/TIES/DOWN CELL 06/08/2026 APPROVED - AS NOTED RSIMS
Note: 6/8/26: Check at next inspection. 1). Truss 12025 needs a strap. FBC [A]107.4 2). Back wall of house: AB (or Titan) missing within 8" of splice FBC [A]107.4 6/1/26: Roof sheathing inspected and approved.
ROOF SHEATHING 06/01/2026 APPROVED RSIMS
Note: This inspection was completed for Roof Sheathing only.
ROOF VALLEY & METAL 06/01/2026 APPROVED RSIMS
WALL SHEATHING 06/01/2026 APPROVED RSIMS
MONOLITHIC SLAB 05/19/2026 APPROVED RSIMS
PLUMBING 1ST ROUGH UNDERGROUND 05/14/2026 APPROVED RSIMS
Note: 5/12/2026 - PREVIOUS INSPECTION NOTES 5/12/26: 1). 5ft head pressure test is not holding as required. FBCR P2503.5 5/8/2026 - PREVIOUS INSPECTION NOTES 5/8/26: Cancelled via text at @ 1013. 5/6/2026 - PREVIOUS INSPECTION NOTES 5/6/26: 1). No 5ft head pressure test as required. FBCR P2503.5 NOTE: Main underground water service piping is installed from house to meter location but no pressure test has been applied. Also, trench for water line is backfilled at the time of this inspection. ___ Trench will need to be opened for visual inspection with pressure test to be inspected by All Rough Inspection 2420 at the latest.
PLUMBING 1ST ROUGH UNDERGROUND 05/12/2026 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 5/12/2026 2:21:49 PM *** 5/12/26: 1). 5ft head pressure test is not holding as required. FBCR P2503.5 5/8/2026 - PREVIOUS INSPECTION NOTES 5/8/26: Cancelled via text at @ 1013. 5/6/2026 - PREVIOUS INSPECTION NOTES 5/6/26: 1). No 5ft head pressure test as required. FBCR P2503.5 NOTE: Main underground water service piping is installed from house to meter location but no pressure test has been applied. Also, trench for water line is backfilled at the time of this inspection. ___ Trench will need to be opened for visual inspection with pressure test to be inspected by All Rough Inspection 2420 at the latest.
PLUMBING 1ST ROUGH UNDERGROUND 05/08/2026 CANCELLED BY APPLICANT RSIMS
Note: 5/8/26: Cancelled via text at @ 1013. 5/6/2026 - PREVIOUS INSPECTION NOTES 5/6/26: 1). No 5ft head pressure test as required. FBCR P2503.5 NOTE: Main underground water service piping is installed from house to meter location but no pressure test has been applied. Also, trench for water line is backfilled at the time of this inspection. ___ Trench will need to be opened for visual inspection with pressure test to be inspected by All Rough Inspection 2420 at the latest.
PLUMBING 1ST ROUGH UNDERGROUND 05/06/2026 Disapproved - NO FEE RSIMS
Note: *** NOTES ADDED BY RSIMS 5/6/2026 1:37:28 PM *** 5/6/26: 1). No 5ft head pressure test as required. FBCR P2503.5 NOTE: Main underground water service piping is installed from house to meter location but no pressure test has been applied. Also, trench for water line is backfilled at the time of this inspection. ___ Trench will need to be opened for visual inspection with pressure test to be inspected by All Rough Inspection 2420 at the latest.
FORMBOARD SURVEY (OFFICE USE ONLY) 05/05/2026 APPROVED RRICKS
GRAVITY SEWER TEST 05/04/2026 APPROVED KSANDOE
SEWER TIE IN 05/04/2026 APPROVED KSANDOE
WATER METER INSTALLATION REQUEST 05/04/2026 APPROVED ISANDERSON
PEP TANK INSTALLATION REQUEST
U-CROSS CONNECTION
ROW- PRE-APRON (PRE-POUR)
ROW - FINAL APRON (AFTER POUR)
ROW - FINAL INSPECTION
U -UTILITY RESIDENTIAL FINAL
ELECTRIC - EARLY POWER
INSULATION
DRYWALL NAILING
BLD - BUILDING FINAL

Review History

Department Status Date In Date Out
SW1 COMPLETE 05/01/2026 05/05/2026
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
BLD COMPLETE 04/28/2026 04/29/2026
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
SW1 COMPLETE 04/28/2026 04/30/2026
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Approved as noted: At the front left side of the home, there shall be a minimum of 23 inches from the top of the formboard to the bottom of the footer. The footer shall gradually transition along the front and side of the home to accommodate the proposed grading and ensure compliance.
SW1 HOLD 04/24/2026 04/28/2026
Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Plans shall be digitally signed and sealed. Please revise.
BLD HOLD 04/24/2026 04/27/2026
Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM Plans need to be digitally verifiable.
ZON COMPLETE 04/07/2026 04/08/2026
Note: Released By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM
SW1 HOLD 04/07/2026 04/13/2026
Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM See Attachments. Structural Plans A3-FDN-LS and FD-2 do not agree with the grading plan. Per grading plan there shall be a minimum of 10.8"(9') adjacent to the foundation at the front left. This allows for a slope no greater than 4:1 and while still maintaining 12" of footer buried per Florida Building Code. Please feel free to call or email if there are any questions or concerns.
ENGIN1 COMPLETE 04/07/2026 04/10/2026
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
BLD COMPLETE 03/19/2026 03/24/2026
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
CUSVC COMPLETE 03/19/2026 03/25/2026
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 03/19/2026 03/26/2026
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 03/19/2026 03/20/2026
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
GAS CANCEL 03/19/2026 03/20/2026
LOCATE COMPLETE 03/19/2026 03/24/2026
Note: Released By: IVAN SANDERSON - -
MECH COMPLETE 03/19/2026 03/23/2026
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 HOLD 03/19/2026 03/25/2026
Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Based on the infromation provided there are slopes greater than 4:1 on both side of the home near the front of the home going to the side lot lines. The maximum amount of fall in 5.8' is 1.45'. Please revise as needed.
ZON HOLD 03/19/2026 03/20/2026
Note: Held By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM Color material sheet accent colors box not checked.
URB COMPLETE 03/19/2026 03/24/2026
Note: Released By: JOHN BEAUDET - (386)986-2456 - JBEAUDET@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
FC IMPACT FEE EMS ¤62.00 05/01/2026
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 05/01/2026
FC IMPACT FEE LIBRARY ¤268.00 05/01/2026
FIRE RES IMPACT FEE 10-25 ¤942.00 05/01/2026
WATER METER W/OUT TAP ¤965.03 05/01/2026
PARKS IMPACT FEE 10-25 ¤3,164.00 05/01/2026
RECLAIM WATER PERMIT INSPECTIO ¤40.00 05/01/2026
RSI DRIVEWAY AFTER POUR ¤16.25 05/01/2026
RSE DRIVE PRE POUR INSPECTION ¤32.50 05/01/2026
RSI FIELD SURVEY INSPECTION ¤48.75 05/01/2026
RSI FORMBOARD REVIEW ¤16.25 05/01/2026
RSI PLAN REVIEW NEW ¤48.75 05/01/2026
RSI FNL SURVEY/GRADING CERT ¤48.75 05/01/2026
RSI ROW FINAL INSPECTION ¤16.25 05/01/2026
SURCHARGE FS 533.721 ¤13.89 05/01/2026
SURCHARGE - FS 468.631 ¤20.84 05/01/2026
TRANSP RES IMPACT FEE 10-25 ¤7,619.17 05/01/2026
TRANSP RES IMPACT FEE 10-25 (¤7,619.17) 05/01/2026
WASTEWATER PERM INSPECTION ¤80.00 05/01/2026
WASTEWATER PERM REVIEW ¤25.00 05/01/2026
SEWER CAPITAL FACILITY ¤2,368.69 05/01/2026
WATER CAPITAL FACILITY FEE ¤1,744.18 05/01/2026
WATER PERMIT REVIEW ¤25.00 05/01/2026
SITE PLAN 30 ¤30.00 05/01/2026
WATER-METER ¤874.47 05/01/2026
WATER- TURN ON ¤50.00 05/01/2026
ADMINISTRATIVE RESIDENTIAL ¤30.00 05/01/2026
INSPECTION - RESIDENTIAL ¤1,058.75 05/01/2026
PLAN REVIEW - RESIDENTIAL ¤300.30 05/01/2026
REINSPECTION RESIDENTIAL ¤40.00
Fees Total Due: ¤40.00 Total Paid: ¤12,507.65