I want to search for...

Permit #2026031005

Permit Details

Status: INSPECT

Parcel Id: 04-11-30-5571-00000-3610
CONDITIONED SPACE: 1638 sqft
GARAGE: 420 sqft
OPENED PORCH (WITH ROOF) : 96 sqft
OPENED PORCH (WITH ROOF) : 112 sqft
Total Square Footage: 2266 sqft
Subdivision: 2366 - SOMERSET SUBDIVISION PH 2
Job Phone: 904-596-6645
Location Address: 100 GOLDEN BELL AVE
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 04/08/2026
NOC: RECORDED
Applicant name: MICHAEL T HOLDER
Owner: KB HOME JACKSONVILLE LLC

Address

10475 FORTUNE PARKWAY

JACKSONVILLE, FL 32256

Address

SUITE 100

JACKSONVILLE, FL 32256

Lot: 361
Contracted Stated Job Value: ¤140,000.00
Job Description: SINGLE FAMILY DWELLING
Type: CN

Contractor

KB HOME JACKSONVILLE, LLC
Status Location Address Mailing Address State License Number Phone
ACTIVE

10475 FORTUNE PKWY

JACKSONVILLE, FL 32256

SUITE 100

JACKSONVILLE, FL 32256

CGC1509034 (Exp: 08/31/2026) 904-596-6645

Sub Contractors

BOBBY WAYNE CAMPBELL
Status Location Address State License Number Phone
ACTIVE

117 GUTHRIE ROAD

GREEN COVE SPRINGS, FL 32043

CCC1326752 (Exp: 08/31/2026) 904-200-1600
JAMES E LINTON
Status Location Address State License Number Phone
ACTIVE

200 COLLEGE DR

ORANGE PARK, FL 32065

EC0001152 (Exp: 08/31/2026) 904-272-0272
LARRY WILLIAMS
Status Location Address State License Number Phone
ACTIVE

1750 EMERSON ST

JACKSONVILLE, FL 32207

LI45034 (Exp: 08/31/2026) 904-721-5431
COREY MICHAEL TENNANT
Status Location Address State License Number Phone
ACTIVE

3370 AGRICULTURAL CNETER DR

ST AUGUSTINE, FL 32092

CAC1819063 (Exp: 08/31/2026) 904-829-8898
BENJAMIN MICHAEL RAY
Status Location Address Mailing Address State License Number Phone Fax
ACTIVE

6310 MABLETON PKWY

JACKSONVILLE, FL 32216

SUITE 1000

MABLETON, GA 30126

CFC1428415 (Exp: 08/31/2026) 904-861-5421 904-861-5426

Inspection History

Type Request Date Result Inspector
LATH/BRICK/ WATER BARRIER 06/08/2026 APPROVED JSTEWART
ROW- PRE-APRON (PRE-POUR) 06/04/2026 APPROVED - AS NOTED EMADISON
Note: ** 06/04/26 ** READY TO POUR ** AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE
DRYWALL NAILING 05/22/2026 Disapproved - NO FEE HCAMACHO
Note: 1. Shower in the master bath is not done.
DRYWALL NAILING 05/22/2026 APPROVED HCAMACHO
Note: 5/22/2026 - PREVIOUS INSPECTION NOTES 1. Shower in the master bath is not done.
INSULATION 05/19/2026 APPROVED JSTEWART
Note: 5/18/2026 - PREVIOUS INSPECTION NOTES 1. Please firestop the top of the sub panel chase. FBC R302.11(4) 2. Multiple miss drills in top plates require fire foam. FBC R302.11(4) 3. ALL low voltage top plate penetration require fire foam. FBC R302.11(4) Inspector Notes from Inspection 2320 NOTE to Builder: Please review plans on starting row of sideing and stone (if applicable), extending down past the concrete and sole plate seam line. Page AD1 detail 20-siding, AD3 detail 44-stone. shows a 2" overlap. Please make sure the install is completed to plans. Inspector Notes from Inspection 2420 1. Install mechanical fasteners at bath exhaust duct to fan assembly. FBCR M1601.4.1 2. Hood duct requires 3 screws at all lap joints. FBCR M1601.4.1 3. romex sheathing min 1/4" into holding box.....front bed switch, middle bed switch, spare bath switch. NEC 314.17(C)
INSULATION 05/18/2026 Disapproved - NO FEE JSTEWART
Note: 1. Please firestop the top of the sub panel chase. FBC R302.11(4) 2. Multiple miss drills in top plates require fire foam. FBC R302.11(4) 3. ALL low voltage top plate penetration require fire foam. FBC R302.11(4) Inspector Notes from Inspection 2320 NOTE to Builder: Please review plans on starting row of sideing and stone (if applicable), extending down past the concrete and sole plate seam line. Page AD1 detail 20-siding, AD3 detail 44-stone. shows a 2" overlap. Please make sure the install is completed to plans. Inspector Notes from Inspection 2420 1. Install mechanical fasteners at bath exhaust duct to fan assembly. FBCR M1601.4.1 2. Hood duct requires 3 screws at all lap joints. FBCR M1601.4.1 3. romex sheathing min 1/4" into holding box.....front bed switch, middle bed switch, spare bath switch. NEC 314.17(C)
LATH/BRICK/ WATER BARRIER 05/14/2026 APPROVED - AS NOTED JSTEWART
Note: NOTE to Builder: Please review plans on starting row of sideing and stone (if applicable), extending down past the concrete and sole plate seam line. Page AD1 detail 20-siding, AD3 detail 44-stone. shows a 2" overlap. Please make sure the install is completed to plans. Inspector Notes from Inspection 2420 1. Install mechanical fasteners at bath exhaust duct to fan assembly. FBCR M1601.4.1 2. Hood duct requires 3 screws at all lap joints. FBCR M1601.4.1 3. romex sheathing min 1/4" into holding box.....front bed switch, middle bed switch, spare bath switch. NEC 314.17(C)
ELECTRIC-TUG 05/11/2026 APPROVED - AS NOTED JSTEWART
Note: Authorize release of email.
ALL ROUGH 05/11/2026 APPROVED - AS NOTED JSTEWART
Note: 1. Install mechanical fasteners at bath exhaust duct to fan assembly. FBCR M1601.4.1 2. Hood duct requires 3 screws at all lap joints. FBCR M1601.4.1 3. romex sheathing min 1/4" into holding box.....front bed switch, middle bed switch, spare bath switch. NEC 314.17(C)
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/08/2026 APPROVED - AS NOTED JSTEWART
Note: Replace (4) structural studs in interior shearwall at HTT tie downs, for integrity of the shearwall 16" OC. 5/1/2026 - PREVIOUS INSPECTION NOTES Not ready, No anchors, tie downs, truss screws etc.
ROOF VALLEY & METAL 05/08/2026 APPROVED JSTEWART
WALL SHEATHING 05/01/2026 APPROVED JSTEWART
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/01/2026 Disapproved - NO FEE JSTEWART
Note: Not ready, No anchors, tie downs, truss screws etc.
GRAVITY SEWER TEST 04/21/2026 APPROVED JSTEWART
Note: Inspector Notes from Inspection 2060 Main water supply line from utility connection to house shut off not installed, will need to be open for inspection at either sewer tie inspection / All Rough inspection.
SEWER TIE IN 04/21/2026 APPROVED JSTEWART
Note: Inspector Notes from Inspection 2060 Main water supply line from utility connection to house shut off not installed, will need to be open for inspection at either sewer tie inspection / All Rough inspection.
MONOLITHIC SLAB 04/16/2026 APPROVED JSTEWART
PLUMBING 1ST ROUGH UNDERGROUND 04/10/2026 APPROVED - AS NOTED JSTEWART
Note: Main water supply line from utility connection to house shut off not installed, will need to be open for inspection at either sewer tie inspection / All Rough inspection.
WATER METER INSTALLATION REQUEST 04/10/2026 APPROVED ISANDERSON
FORMBOARD SURVEY (OFFICE USE ONLY) 04/09/2026 APPROVED PFLANAGAN
ELECTRIC - EARLY POWER
BLD - BUILDING FINAL
U-CROSS CONNECTION
ROW - FINAL APRON (AFTER POUR)
ROW - FINAL INSPECTION
U -UTILITY RESIDENTIAL FINAL

Review History

Department Status Date In Date Out
SW1 COMPLETE 04/09/2026 04/09/2026
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON COMPLETE 04/09/2026 04/09/2026
Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM
BLD COMPLETE 03/25/2026 03/31/2026
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
CUSVC COMPLETE 03/25/2026 04/01/2026
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 03/25/2026 03/30/2026
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 03/25/2026 03/26/2026
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
GAS COMPLETE 03/25/2026 03/26/2026
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
LOCATE COMPLETE 03/25/2026 03/26/2026
Note: Released By: IVAN SANDERSON - -
MECH COMPLETE 03/25/2026 03/27/2026
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 03/25/2026 04/01/2026
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 03/25/2026 03/26/2026
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
URB COMPLETE 03/25/2026 04/01/2026
Note: Released By: JOHN BEAUDET - (386)986-2456 - JBEAUDET@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
WATER-METER ¤874.47 04/08/2026
WATER- TURN ON ¤50.00 04/08/2026
ADMINISTRATIVE RESIDENTIAL ¤30.00 04/08/2026
INSPECTION - RESIDENTIAL ¤891.00 04/08/2026
PLAN REVIEW - RESIDENTIAL ¤252.72 04/08/2026
FC IMPACT FEE EMS ¤62.00 04/08/2026
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 04/08/2026
FC IMPACT FEE LIBRARY ¤268.00 04/08/2026
FIRE RES IMPACT FEE 10-25 ¤942.00 04/08/2026
WATER METER W/OUT TAP ¤965.03 04/08/2026
PARKS IMPACT FEE 10-25 ¤3,164.00 04/08/2026
RECLAIM WATER PERMIT INSPECTIO ¤40.00 04/08/2026
RSI DRIVEWAY AFTER POUR ¤16.25 04/08/2026
RSE DRIVE PRE POUR INSPECTION ¤32.50 04/08/2026
RSI FORMBOARD REVIEW ¤16.25 04/08/2026
RSI PLAN REVIEW NEW ¤48.75 04/08/2026
RSI FNL SURVEY/GRADING CERT ¤48.75 04/08/2026
RSI ROW FINAL INSPECTION ¤16.25 04/08/2026
SCHOOL BOARD IMPACT FEE RES ¤5,450.00 04/08/2026
SURCHARGE FS 533.721 ¤11.74 04/08/2026
SURCHARGE - FS 468.631 ¤17.61 04/08/2026
TRANSP RES IMPACT FEE 10-25 ¤6,175.26 04/08/2026
WASTEWATER PERM INSPECTION ¤80.00 04/08/2026
WASTEWATER PERM REVIEW ¤25.00 04/08/2026
SEWER CAPITAL FACILITY ¤3,628.86 04/08/2026
WATER CAPITAL FACILITY FEE ¤3,091.14 04/08/2026
WATER PERMIT REVIEW ¤25.00 04/08/2026
SITE PLAN 30 ¤30.00 04/08/2026
Fees Total Due: ¤0.00 Total Paid: ¤26,470.58