Permit #2026031005
Permit Details
Status: INSPECT
| Parcel Id: 04-11-30-5571-00000-3610 |
| CONDITIONED SPACE: 1638 sqft |
| GARAGE: 420 sqft |
| OPENED PORCH (WITH ROOF) : 96 sqft |
| OPENED PORCH (WITH ROOF) : 112 sqft |
| Total Square Footage: 2266 sqft |
| Subdivision: 2366 - SOMERSET SUBDIVISION PH 2 |
| Job Phone: 904-596-6645 |
| Location Address: 100 GOLDEN BELL AVE |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 04/08/2026 |
| NOC: RECORDED |
| Applicant name: MICHAEL T HOLDER |
| Owner: KB HOME JACKSONVILLE LLC |
|
Address 10475 FORTUNE PARKWAY JACKSONVILLE, FL 32256 |
|
Address SUITE 100 JACKSONVILLE, FL 32256 |
| Lot: 361 |
| Contracted Stated Job Value: ¤140,000.00 |
| Job Description: SINGLE FAMILY DWELLING |
| Type: CN |
Contractor
KB HOME JACKSONVILLE, LLC
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
10475 FORTUNE PKWY JACKSONVILLE, FL 32256 |
SUITE 100 JACKSONVILLE, FL 32256 |
CGC1509034 (Exp: 08/31/2026) | 904-596-6645 |
Sub Contractors
BOBBY WAYNE CAMPBELL
| Status | Location Address | State License Number | Phone |
| ACTIVE |
117 GUTHRIE ROAD GREEN COVE SPRINGS, FL 32043 |
CCC1326752 (Exp: 08/31/2026) | 904-200-1600 |
JAMES E LINTON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
200 COLLEGE DR ORANGE PARK, FL 32065 |
EC0001152 (Exp: 08/31/2026) | 904-272-0272 |
LARRY WILLIAMS
| Status | Location Address | State License Number | Phone |
| ACTIVE |
1750 EMERSON ST JACKSONVILLE, FL 32207 |
LI45034 (Exp: 08/31/2026) | 904-721-5431 |
COREY MICHAEL TENNANT
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3370 AGRICULTURAL CNETER DR ST AUGUSTINE, FL 32092 |
CAC1819063 (Exp: 08/31/2026) | 904-829-8898 |
BENJAMIN MICHAEL RAY
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| ACTIVE |
6310 MABLETON PKWY JACKSONVILLE, FL 32216 |
SUITE 1000 MABLETON, GA 30126 |
CFC1428415 (Exp: 08/31/2026) | 904-861-5421 | 904-861-5426 |
Inspection History
| Type | Request Date | Result | Inspector |
| LATH/BRICK/ WATER BARRIER | 06/08/2026 | APPROVED | JSTEWART |
| ROW- PRE-APRON (PRE-POUR) | 06/04/2026 | APPROVED - AS NOTED | EMADISON |
| Note: ** 06/04/26 ** READY TO POUR ** AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE | |||
| DRYWALL NAILING | 05/22/2026 | Disapproved - NO FEE | HCAMACHO |
| Note: 1. Shower in the master bath is not done. | |||
| DRYWALL NAILING | 05/22/2026 | APPROVED | HCAMACHO |
| Note: 5/22/2026 - PREVIOUS INSPECTION NOTES 1. Shower in the master bath is not done. | |||
| INSULATION | 05/19/2026 | APPROVED | JSTEWART |
| Note: 5/18/2026 - PREVIOUS INSPECTION NOTES 1. Please firestop the top of the sub panel chase. FBC R302.11(4) 2. Multiple miss drills in top plates require fire foam. FBC R302.11(4) 3. ALL low voltage top plate penetration require fire foam. FBC R302.11(4) Inspector Notes from Inspection 2320 NOTE to Builder: Please review plans on starting row of sideing and stone (if applicable), extending down past the concrete and sole plate seam line. Page AD1 detail 20-siding, AD3 detail 44-stone. shows a 2" overlap. Please make sure the install is completed to plans. Inspector Notes from Inspection 2420 1. Install mechanical fasteners at bath exhaust duct to fan assembly. FBCR M1601.4.1 2. Hood duct requires 3 screws at all lap joints. FBCR M1601.4.1 3. romex sheathing min 1/4" into holding box.....front bed switch, middle bed switch, spare bath switch. NEC 314.17(C) | |||
| INSULATION | 05/18/2026 | Disapproved - NO FEE | JSTEWART |
| Note: 1. Please firestop the top of the sub panel chase. FBC R302.11(4) 2. Multiple miss drills in top plates require fire foam. FBC R302.11(4) 3. ALL low voltage top plate penetration require fire foam. FBC R302.11(4) Inspector Notes from Inspection 2320 NOTE to Builder: Please review plans on starting row of sideing and stone (if applicable), extending down past the concrete and sole plate seam line. Page AD1 detail 20-siding, AD3 detail 44-stone. shows a 2" overlap. Please make sure the install is completed to plans. Inspector Notes from Inspection 2420 1. Install mechanical fasteners at bath exhaust duct to fan assembly. FBCR M1601.4.1 2. Hood duct requires 3 screws at all lap joints. FBCR M1601.4.1 3. romex sheathing min 1/4" into holding box.....front bed switch, middle bed switch, spare bath switch. NEC 314.17(C) | |||
| LATH/BRICK/ WATER BARRIER | 05/14/2026 | APPROVED - AS NOTED | JSTEWART |
| Note: NOTE to Builder: Please review plans on starting row of sideing and stone (if applicable), extending down past the concrete and sole plate seam line. Page AD1 detail 20-siding, AD3 detail 44-stone. shows a 2" overlap. Please make sure the install is completed to plans. Inspector Notes from Inspection 2420 1. Install mechanical fasteners at bath exhaust duct to fan assembly. FBCR M1601.4.1 2. Hood duct requires 3 screws at all lap joints. FBCR M1601.4.1 3. romex sheathing min 1/4" into holding box.....front bed switch, middle bed switch, spare bath switch. NEC 314.17(C) | |||
| ELECTRIC-TUG | 05/11/2026 | APPROVED - AS NOTED | JSTEWART |
| Note: Authorize release of email. | |||
| ALL ROUGH | 05/11/2026 | APPROVED - AS NOTED | JSTEWART |
| Note: 1. Install mechanical fasteners at bath exhaust duct to fan assembly. FBCR M1601.4.1 2. Hood duct requires 3 screws at all lap joints. FBCR M1601.4.1 3. romex sheathing min 1/4" into holding box.....front bed switch, middle bed switch, spare bath switch. NEC 314.17(C) | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 05/08/2026 | APPROVED - AS NOTED | JSTEWART |
| Note: Replace (4) structural studs in interior shearwall at HTT tie downs, for integrity of the shearwall 16" OC. 5/1/2026 - PREVIOUS INSPECTION NOTES Not ready, No anchors, tie downs, truss screws etc. | |||
| ROOF VALLEY & METAL | 05/08/2026 | APPROVED | JSTEWART |
| WALL SHEATHING | 05/01/2026 | APPROVED | JSTEWART |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 05/01/2026 | Disapproved - NO FEE | JSTEWART |
| Note: Not ready, No anchors, tie downs, truss screws etc. | |||
| GRAVITY SEWER TEST | 04/21/2026 | APPROVED | JSTEWART |
| Note: Inspector Notes from Inspection 2060 Main water supply line from utility connection to house shut off not installed, will need to be open for inspection at either sewer tie inspection / All Rough inspection. | |||
| SEWER TIE IN | 04/21/2026 | APPROVED | JSTEWART |
| Note: Inspector Notes from Inspection 2060 Main water supply line from utility connection to house shut off not installed, will need to be open for inspection at either sewer tie inspection / All Rough inspection. | |||
| MONOLITHIC SLAB | 04/16/2026 | APPROVED | JSTEWART |
| PLUMBING 1ST ROUGH UNDERGROUND | 04/10/2026 | APPROVED - AS NOTED | JSTEWART |
| Note: Main water supply line from utility connection to house shut off not installed, will need to be open for inspection at either sewer tie inspection / All Rough inspection. | |||
| WATER METER INSTALLATION REQUEST | 04/10/2026 | APPROVED | ISANDERSON |
| FORMBOARD SURVEY (OFFICE USE ONLY) | 04/09/2026 | APPROVED | PFLANAGAN |
| ELECTRIC - EARLY POWER | |||
| BLD - BUILDING FINAL | |||
| U-CROSS CONNECTION | |||
| ROW - FINAL APRON (AFTER POUR) | |||
| ROW - FINAL INSPECTION | |||
| U -UTILITY RESIDENTIAL FINAL |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 04/09/2026 | 04/09/2026 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 04/09/2026 | 04/09/2026 |
| Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 03/25/2026 | 03/31/2026 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 03/25/2026 | 04/01/2026 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 03/25/2026 | 03/30/2026 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 03/25/2026 | 03/26/2026 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| GAS | COMPLETE | 03/25/2026 | 03/26/2026 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 03/25/2026 | 03/26/2026 |
| Note: Released By: IVAN SANDERSON - - | |||
| MECH | COMPLETE | 03/25/2026 | 03/27/2026 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 03/25/2026 | 04/01/2026 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 03/25/2026 | 03/26/2026 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| URB | COMPLETE | 03/25/2026 | 04/01/2026 |
| Note: Released By: JOHN BEAUDET - (386)986-2456 - JBEAUDET@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| WATER-METER | ¤874.47 | 04/08/2026 |
| WATER- TURN ON | ¤50.00 | 04/08/2026 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 04/08/2026 |
| INSPECTION - RESIDENTIAL | ¤891.00 | 04/08/2026 |
| PLAN REVIEW - RESIDENTIAL | ¤252.72 | 04/08/2026 |
| FC IMPACT FEE EMS | ¤62.00 | 04/08/2026 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 04/08/2026 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 04/08/2026 |
| FIRE RES IMPACT FEE 10-25 | ¤942.00 | 04/08/2026 |
| WATER METER W/OUT TAP | ¤965.03 | 04/08/2026 |
| PARKS IMPACT FEE 10-25 | ¤3,164.00 | 04/08/2026 |
| RECLAIM WATER PERMIT INSPECTIO | ¤40.00 | 04/08/2026 |
| RSI DRIVEWAY AFTER POUR | ¤16.25 | 04/08/2026 |
| RSE DRIVE PRE POUR INSPECTION | ¤32.50 | 04/08/2026 |
| RSI FORMBOARD REVIEW | ¤16.25 | 04/08/2026 |
| RSI PLAN REVIEW NEW | ¤48.75 | 04/08/2026 |
| RSI FNL SURVEY/GRADING CERT | ¤48.75 | 04/08/2026 |
| RSI ROW FINAL INSPECTION | ¤16.25 | 04/08/2026 |
| SCHOOL BOARD IMPACT FEE RES | ¤5,450.00 | 04/08/2026 |
| SURCHARGE FS 533.721 | ¤11.74 | 04/08/2026 |
| SURCHARGE - FS 468.631 | ¤17.61 | 04/08/2026 |
| TRANSP RES IMPACT FEE 10-25 | ¤6,175.26 | 04/08/2026 |
| WASTEWATER PERM INSPECTION | ¤80.00 | 04/08/2026 |
| WASTEWATER PERM REVIEW | ¤25.00 | 04/08/2026 |
| SEWER CAPITAL FACILITY | ¤3,628.86 | 04/08/2026 |
| WATER CAPITAL FACILITY FEE | ¤3,091.14 | 04/08/2026 |
| WATER PERMIT REVIEW | ¤25.00 | 04/08/2026 |
| SITE PLAN 30 | ¤30.00 | 04/08/2026 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤26,470.58 |