Permit #2026031008
Permit Details
Status: INSPECT
| Parcel Id: 04-11-30-5571-00000-3480 |
| CONDITIONED SPACE: 1342 sqft |
| GARAGE: 462 sqft |
| OPENED PORCH (WITH ROOF) : 34 sqft |
| OPENED PORCH (WITH ROOF) : 84 sqft |
| Total Square Footage: 1922 sqft |
| Subdivision: 2366 - SOMERSET SUBDIVISION PH 2 |
| Job Phone: 904-596-6645 |
| Location Address: 117 GOLDEN BELL AVE |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 04/08/2026 |
| NOC: RECORDED |
| Applicant name: MICHAEL T HOLDER |
| Owner: KB HOME JACKSONVILLE LLC |
|
Address 10475 FORTUNE PARKWAY JACKSONVILLE, FL 32256 |
|
Address SUITE 100 JACKSONVILLE, FL 32256 |
| Lot: 348 |
| Contracted Stated Job Value: ¤140,000.00 |
| Job Description: SINGLE FAMILY DWELLING |
| Type: CN |
Contractor
KB HOME JACKSONVILLE, LLC
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
10475 FORTUNE PKWY JACKSONVILLE, FL 32256 |
SUITE 100 JACKSONVILLE, FL 32256 |
CGC1509034 (Exp: 08/31/2026) | 904-596-6645 |
Sub Contractors
LARRY WILLIAMS
| Status | Location Address | State License Number | Phone |
| ACTIVE |
1750 EMERSON ST JACKSONVILLE, FL 32207 |
LI45034 (Exp: 08/31/2026) | 904-721-5431 |
JAMES E LINTON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
200 COLLEGE DR ORANGE PARK, FL 32065 |
EC0001152 (Exp: 08/31/2026) | 904-272-0272 |
BOBBY WAYNE CAMPBELL
| Status | Location Address | State License Number | Phone |
| ACTIVE |
117 GUTHRIE ROAD GREEN COVE SPRINGS, FL 32043 |
CCC1326752 (Exp: 08/31/2026) | 904-200-1600 |
COREY MICHAEL TENNANT
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3370 AGRICULTURAL CNETER DR ST AUGUSTINE, FL 32092 |
CAC1819063 (Exp: 08/31/2026) | 904-829-8898 |
BENJAMIN MICHAEL RAY
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| ACTIVE |
6310 MABLETON PKWY JACKSONVILLE, FL 32216 |
SUITE 1000 MABLETON, GA 30126 |
CFC1428415 (Exp: 08/31/2026) | 904-861-5421 | 904-861-5426 |
Inspection History
| Type | Request Date | Result | Inspector |
| ELECTRIC - EARLY POWER | 06/11/2026 | APPROVED | JSTEWART |
| Note: 6/10/2026 - PREVIOUS INSPECTION NOTES Approval of inspection is required prior to Power being turned on to the building. Please disconnect the load wires and tape the ends for Re inspection. FBC [A]112.1 Connection of service utilities. Inspector Notes from Inspection 2200 Authorize release of email | |||
| ROW- PRE-APRON (PRE-POUR) | 06/11/2026 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. . TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, IN THE UPCOMING MONTHS THE DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS WILL BE REQUIRED TO BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. YOU WILL RECEIVE A NEWS BLAST WHEN THIS BECOMES NECESSARY | |||
| ELECTRIC - EARLY POWER | 06/10/2026 | Disapproved -FEE REQUIRED | JSTEWART |
| Note: Approval of inspection is required prior to Power being turned on to the building. Please disconnect the load wires and tape the ends for Re inspection. FBC [A]112.1 Connection of service utilities. Inspector Notes from Inspection 2200 Authorize release of email | |||
| ROW- PRE-APRON (PRE-POUR) | 05/28/2026 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. . TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, IN THE UPCOMING MONTHS THE DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS WILL BE REQUIRED TO BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. YOU WILL RECEIVE A NEWS BLAST WHEN THIS BECOMES NECESSARY. 5/27/2026 - PREVIOUS INSPECTION NOTES ** 05/27/26 DRIVEWAY POR AREA ABOVE THE APRON REQUIRES A MINIMUM OF 4 INCHES OF CONCRETE NEED TO REMOVE THE HIGH SPOT IN CENTER OF DRIVEWAY ** SEE ATTACHED PHOTOS | |||
| ROW- PRE-APRON (PRE-POUR) | 05/27/2026 | Disapproved -FEE REQUIRED | EMADISON |
| Note: ** 05/27/26 DRIVEWAY POR AREA ABOVE THE APRON REQUIRES A MINIMUM OF 4 INCHES OF CONCRETE NEED TO REMOVE THE HIGH SPOT IN CENTER OF DRIVEWAY ** SEE ATTACHED PHOTOS | |||
| DRYWALL NAILING | 05/19/2026 | APPROVED | JSTEWART |
| INSULATION | 05/15/2026 | APPROVED | JSTEWART |
| Note: 5/14/2026 - PREVIOUS INSPECTION NOTES Sub panel chase missing ceiling backing, 2x fire block, then Firefoam for smal annular space around romex home runs. NEC 300.4 / FBC R302.11(4) / FBC R302.11(1.2) Inspector Notes from Inspection 2420 1. Studs replaced from previous Note need to be fastened to the sole plate, and structural sheathing nailed (Shearwall interior, each side of the garage to house door). per plan 2. Mechanical fasteners at all bath exhaust duct to fan assembly. FBCR M1601.4.1 3. Romex sheathing min of 1/4" inside holding box. (master bed switch, master closet outlet, master bath vanity outlet). NEC 314.17(C 4. Metal ceiling Light Box needs to be Bonded. NEC 314.4 Will check at insulation. Inspector Notes from Inspection 2467 Inspector Notes from Inspection 2450 | |||
| INSULATION | 05/14/2026 | Disapproved - NO FEE | JSTEWART |
| Note: Sub panel chase missing ceiling backing, 2x fire block, then Firefoam for smal annular space around romex home runs. NEC 300.4 / FBC R302.11(4) / FBC R302.11(1.2) Inspector Notes from Inspection 2420 1. Studs replaced from previous Note need to be fastened to the sole plate, and structural sheathing nailed (Shearwall interior, each side of the garage to house door). per plan 2. Mechanical fasteners at all bath exhaust duct to fan assembly. FBCR M1601.4.1 3. Romex sheathing min of 1/4" inside holding box. (master bed switch, master closet outlet, master bath vanity outlet). NEC 314.17(C 4. Metal ceiling Light Box needs to be Bonded. NEC 314.4 Will check at insulation. Inspector Notes from Inspection 2467 Inspector Notes from Inspection 2450 | |||
| LATH/BRICK/ WATER BARRIER | 05/14/2026 | APPROVED - AS NOTED | JSTEWART |
| Note: NOTE to Builder: Please review plans on starting row of sideing and stone (if applicable), extending down past the concrete and sole plate seam line. Page AD1 detail 20-siding, AD3 detail 44-stone. shows a 2" overlap. Please make sure the install is completed to plans. Inspector Notes from Inspection 2420 1. Studs replaced from previous Note need to be fastened to the sole plate, and structural sheathing nailed (Shearwall interior, each side of the garage to house door). per plan 2. Mechanical fasteners at all bath exhaust duct to fan assembly. FBCR M1601.4.1 3. Romex sheathing min of 1/4" inside holding box. (master bed switch, master closet outlet, master bath vanity outlet). NEC 314.17(C 4. Metal ceiling Light Box needs to be Bonded. NEC 314.4 Will check at insulation. Inspector Notes from Inspection 2467 Inspector Notes from Inspection 2450 | |||
| ALL ROUGH | 05/11/2026 | APPROVED - AS NOTED | JSTEWART |
| Note: 1. Studs replaced from previous Note need to be fastened to the sole plate, and structural sheathing nailed (Shearwall interior, each side of the garage to house door). per plan 2. Mechanical fasteners at all bath exhaust duct to fan assembly. FBCR M1601.4.1 3. Romex sheathing min of 1/4" inside holding box. (master bed switch, master closet outlet, master bath vanity outlet). NEC 314.17(C 4. Metal ceiling Light Box needs to be Bonded. NEC 314.4 Will check at insulation. Inspector Notes from Inspection 2467 Inspector Notes from Inspection 2450 | |||
| ELECTRIC-TUG | 05/11/2026 | APPROVED - AS NOTED | JSTEWART |
| Note: Authorize release of email | |||
| ROOF VALLEY & METAL | 05/08/2026 | APPROVED - AS NOTED | JSTEWART |
| Note: Inspector Notes from Inspection 2450 | |||
| WALL SHEATHING | 05/01/2026 | APPROVED - AS NOTED | JSTEWART |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 05/01/2026 | APPROVED - AS NOTED | JSTEWART |
| Note: re fasten studs at each side of garage to house door opening....HTT's verified. | |||
| GRAVITY SEWER TEST | 04/29/2026 | APPROVED | JSTEWART |
| Note: Live virtual inspection. 4/21/2026 - PREVIOUS INSPECTION NOTES No 5ft head test empty. FBCR P2503.5 Inspector Notes from Inspection 2060 Main water supply line from utility connection to house shut off not installed, will need to be open for inspection at either sewer tie inspection / All Rough inspection. 4/10/2026 - PREVIOUS INSPECTION NOTES | |||
| SEWER TIE IN | 04/21/2026 | APPROVED | JSTEWART |
| Note: Inspector Notes from Inspection 2060 Main water supply line from utility connection to house shut off not installed, will need to be open for inspection at either sewer tie inspection / All Rough inspection. 4/10/2026 - PREVIOUS INSPECTION NOTES | |||
| GRAVITY SEWER TEST | 04/21/2026 | Disapproved - NO FEE | JSTEWART |
| Note: No 5ft head test empty. FBCR P2503.5 Inspector Notes from Inspection 2060 Main water supply line from utility connection to house shut off not installed, will need to be open for inspection at either sewer tie inspection / All Rough inspection. 4/10/2026 - PREVIOUS INSPECTION NOTES | |||
| MONOLITHIC SLAB | 04/16/2026 | Disapproved - NO FEE | JSTEWART |
| Note: Reinforcement requires 3" min clearence from soil. (column pads rebar is in the soil, cave ins, porch to main transitions.) | |||
| MONOLITHIC SLAB | 04/16/2026 | APPROVED | JSTEWART |
| Note: Live virtual re inspection, correction made 4/16/2026 - PREVIOUS INSPECTION NOTES Reinforcement requires 3" min clearence from soil. (column pads rebar is in the soil, cave ins, porch to main transitions.) | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 04/13/2026 | APPROVED - AS NOTED | JSTEWART |
| Note: Main water supply line from utility connection to house shut off not installed, will need to be open for inspection at either sewer tie inspection / All Rough inspection. 4/10/2026 - PREVIOUS INSPECTION NOTES | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 04/10/2026 | CANCELLED BY APPLICANT | JSTEWART |
| WATER METER INSTALLATION REQUEST | 04/10/2026 | APPROVED | ISANDERSON |
| FORMBOARD SURVEY (OFFICE USE ONLY) | 04/09/2026 | APPROVED | PFLANAGAN |
| U-CROSS CONNECTION | |||
| BLD - BUILDING FINAL | |||
| ROW - FINAL APRON (AFTER POUR) | |||
| ROW - FINAL INSPECTION | |||
| U -UTILITY RESIDENTIAL FINAL |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 04/09/2026 | 04/09/2026 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 04/09/2026 | 04/09/2026 |
| Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 04/02/2026 | 04/06/2026 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 03/25/2026 | 03/31/2026 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 03/25/2026 | 04/01/2026 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 03/25/2026 | 03/30/2026 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 03/25/2026 | 03/26/2026 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| GAS | COMPLETE | 03/25/2026 | 03/26/2026 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 03/25/2026 | 03/26/2026 |
| Note: Released By: IVAN SANDERSON - - | |||
| MECH | COMPLETE | 03/25/2026 | 03/27/2026 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 03/25/2026 | 04/01/2026 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ZON | HOLD | 03/25/2026 | 03/26/2026 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Floor plan: Ac unit is in a different location as the site plan and the landscape plan. Please adjust plans correctly. | |||
| URB | COMPLETE | 03/25/2026 | 04/01/2026 |
| Note: Released By: JOHN BEAUDET - (386)986-2456 - JBEAUDET@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| FC IMPACT FEE EMS | ¤62.00 | 04/08/2026 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 04/08/2026 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 04/08/2026 |
| FIRE RES IMPACT FEE 10-25 | ¤942.00 | 04/08/2026 |
| WATER METER W/OUT TAP | ¤965.03 | 04/08/2026 |
| PARKS IMPACT FEE 10-25 | ¤3,164.00 | 04/08/2026 |
| RECLAIM WATER PERMIT INSPECTIO | ¤40.00 | 04/08/2026 |
| RSI DRIVEWAY AFTER POUR | ¤16.25 | 04/08/2026 |
| RSE DRIVE PRE POUR INSPECTION | ¤32.50 | 04/08/2026 |
| RSI FORMBOARD REVIEW | ¤16.25 | 04/08/2026 |
| RSI PLAN REVIEW NEW | ¤48.75 | 04/08/2026 |
| RSI FNL SURVEY/GRADING CERT | ¤48.75 | 04/08/2026 |
| RSI ROW FINAL INSPECTION | ¤16.25 | 04/08/2026 |
| SCHOOL BOARD IMPACT FEE RES | ¤5,450.00 | 04/08/2026 |
| SURCHARGE FS 533.721 | ¤9.83 | 04/08/2026 |
| SURCHARGE - FS 468.631 | ¤14.75 | 04/08/2026 |
| TRANSP RES IMPACT FEE 10-25 | ¤5,059.34 | 04/08/2026 |
| WASTEWATER PERM INSPECTION | ¤80.00 | 04/08/2026 |
| WASTEWATER PERM REVIEW | ¤25.00 | 04/08/2026 |
| SEWER CAPITAL FACILITY | ¤3,628.86 | 04/08/2026 |
| WATER CAPITAL FACILITY FEE | ¤3,091.14 | 04/08/2026 |
| WATER PERMIT REVIEW | ¤25.00 | 04/08/2026 |
| SITE PLAN 30 | ¤30.00 | 04/08/2026 |
| WATER-METER | ¤874.47 | 04/08/2026 |
| WATER- TURN ON | ¤50.00 | 04/08/2026 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 04/08/2026 |
| INSPECTION - RESIDENTIAL | ¤742.50 | 04/08/2026 |
| PLAN REVIEW - RESIDENTIAL | ¤210.60 | 04/08/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | |
| RSI REINSPECTION 1 | ¤35.00 | |
| Fees | Total Due: ¤75.00 | Total Paid: ¤25,159.27 |