I want to search for...

Permit #2026031009

Permit Details

Status: INSPECT

Parcel Id: 04-11-30-5571-00000-3460
CONDITIONED SPACE: 1501 sqft
GARAGE: 419 sqft
OPENED PORCH (WITH ROOF) : 72 sqft
OPENED PORCH (WITH ROOF) : 115 sqft
Total Square Footage: 2107 sqft
Subdivision: 2366 - SOMERSET SUBDIVISION PH 2
Job Phone: 904-596-6645
Location Address: 113 GOLDEN BELL AVE
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 04/08/2026
NOC: RECORDED
Applicant name: MICHAEL T HOLDER
Owner: KB HOME JACKSONVILLE LLC

Address

10475 FORTUNE PARKWAY

JACKSONVILLE, FL 32256

Address

SUITE 100

JACKSONVILLE, FL 32256

Lot: 346
Contracted Stated Job Value: ¤140,000.00
Job Description: NEW SINGLE FAMILY DWELLING
Type: CN

Contractor

KB HOME JACKSONVILLE, LLC
Status Location Address Mailing Address State License Number Phone
ACTIVE

10475 FORTUNE PKWY

JACKSONVILLE, FL 32256

SUITE 100

JACKSONVILLE, FL 32256

CGC1509034 (Exp: 08/31/2026) 904-596-6645

Sub Contractors

JAMES E LINTON
Status Location Address State License Number Phone
ACTIVE

200 COLLEGE DR

ORANGE PARK, FL 32065

EC0001152 (Exp: 08/31/2026) 904-272-0272
BOBBY WAYNE CAMPBELL
Status Location Address State License Number Phone
ACTIVE

117 GUTHRIE ROAD

GREEN COVE SPRINGS, FL 32043

CCC1326752 (Exp: 08/31/2026) 904-200-1600
LARRY WILLIAMS
Status Location Address State License Number Phone
ACTIVE

1750 EMERSON ST

JACKSONVILLE, FL 32207

LI45034 (Exp: 08/31/2026) 904-721-5431
COREY MICHAEL TENNANT
Status Location Address State License Number Phone
ACTIVE

3370 AGRICULTURAL CNETER DR

ST AUGUSTINE, FL 32092

CAC1819063 (Exp: 08/31/2026) 904-829-8898
BENJAMIN MICHAEL RAY
Status Location Address Mailing Address State License Number Phone Fax
ACTIVE

6310 MABLETON PKWY

JACKSONVILLE, FL 32216

SUITE 1000

MABLETON, GA 30126

CFC1428415 (Exp: 08/31/2026) 904-861-5421 904-861-5426

Inspection History

Type Request Date Result Inspector
ELECTRIC - EARLY POWER 06/11/2026 JSTEWART
Note: 6/10/2026 - PREVIOUS INSPECTION NOTES Approval of inspection is required prior to Power being turned on to the building. Please disconnect the load wires and tape the ends for Re inspection. FBC [A]112.1 Connection of service utilities. Inspector Notes from Inspection 2200 Authorize release of email
ELECTRIC - EARLY POWER 06/10/2026 Disapproved -FEE REQUIRED JSTEWART
Note: Approval of inspection is required prior to Power being turned on to the building. Please disconnect the load wires and tape the ends for Re inspection. FBC [A]112.1 Connection of service utilities. Inspector Notes from Inspection 2200 Authorize release of email
ROW- PRE-APRON (PRE-POUR) 06/02/2026 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. . TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, IN THE UPCOMING MONTHS THE DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS WILL BE REQUIRED TO BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. YOU WILL RECEIVE A NEWS BLAST WHEN THIS BECOMES NECESSARY. 6/1/2026 - PREVIOUS INSPECTION NOTES ** 06/01/26 CANCELLED VIA TEXT MESSAGE FROM STACEY ________________________________________________________________________________________________________________________ 5/28/2026 - PREVIOUS INSPECTION NOTES 05-28-26 TPOLACEK*** MET WITH CM TO SHOW THEY ONLY CLEARED ALONG STRING LINES AND NOT THE ENTIRE POUR AREA. ALONG VALLEYGUTTER HAD 5" NOT THE REQUIRED 6" FOR APRON DEPTH. ALL DEBRIS UP BY GARAGE MUST BE REMOVED AND POUR AREA SHALL BE FREE OF MATERIALS. 5/27/2026 - PREVIOUS INSPECTION NOTES ** 05/27/26 DRIVEWAY POR AREA ABOVE THE APRON REQUIRES A MINIMUM OF 4 INCHES OF CONCRETE NEED TO REMOVE THE HIGH SPOT IN CENTER OF DRIVEWAY ** SEE ATTACHED PHOTOS
ROW- PRE-APRON (PRE-POUR) 06/01/2026 CANCELLED BY APPLICANT EMADISON
Note: ** 06/01/26 CANCELLED VIA TEXT MESSAGE FROM STACEY ________________________________________________________________________________________________________________________ 5/28/2026 - PREVIOUS INSPECTION NOTES 05-28-26 TPOLACEK*** MET WITH CM TO SHOW THEY ONLY CLEARED ALONG STRING LINES AND NOT THE ENTIRE POUR AREA. ALONG VALLEYGUTTER HAD 5" NOT THE REQUIRED 6" FOR APRON DEPTH. ALL DEBRIS UP BY GARAGE MUST BE REMOVED AND POUR AREA SHALL BE FREE OF MATERIALS. 5/27/2026 - PREVIOUS INSPECTION NOTES ** 05/27/26 DRIVEWAY POR AREA ABOVE THE APRON REQUIRES A MINIMUM OF 4 INCHES OF CONCRETE NEED TO REMOVE THE HIGH SPOT IN CENTER OF DRIVEWAY ** SEE ATTACHED PHOTOS
ROW- PRE-APRON (PRE-POUR) 05/28/2026 Disapproved - NO FEE TPOLACEK
Note: 05-28-26 TPOLACEK*** MET WITH CM TO SHOW THEY ONLY CLEARED ALONG STRING LINES AND NOT THE ENTIRE POUR AREA. ALONG VALLEYGUTTER HAD 5" NOT THE REQUIRED 6" FOR APRON DEPTH. ALL DEBRIS UP BY GARAGE MUST BE REMOVED AND POUR AREA SHALL BE FREE OF MATERIALS. 5/27/2026 - PREVIOUS INSPECTION NOTES ** 05/27/26 DRIVEWAY POR AREA ABOVE THE APRON REQUIRES A MINIMUM OF 4 INCHES OF CONCRETE NEED TO REMOVE THE HIGH SPOT IN CENTER OF DRIVEWAY ** SEE ATTACHED PHOTOS
ROW- PRE-APRON (PRE-POUR) 05/27/2026 Disapproved -FEE REQUIRED EMADISON
Note: ** 05/27/26 DRIVEWAY POR AREA ABOVE THE APRON REQUIRES A MINIMUM OF 4 INCHES OF CONCRETE NEED TO REMOVE THE HIGH SPOT IN CENTER OF DRIVEWAY ** SEE ATTACHED PHOTOS
DRYWALL NAILING 05/15/2026 APPROVED JSTEWART
INSULATION 05/12/2026 APPROVED JSTEWART
LATH/BRICK/ WATER BARRIER 05/11/2026 APPROVED JSTEWART
Note: 5/8/2026 - PREVIOUS INSPECTION NOTES 1. water barrier at AC power wall penetration. 2. Front entry door not installed (onsite).
ALL ROUGH 05/08/2026 APPROVED - AS NOTED JSTEWART
Note: 1. No water preassure test. 2. No 5ft head test. 3. install Mechanical fastener at all bath exhaust duct to fan assembly. 4. Seal exhaust duct roof penetration in spare bath. will check at insulation.
LATH/BRICK/ WATER BARRIER 05/08/2026 Disapproved - NO FEE JSTEWART
Note: 1. water barrier at AC power wall penetration. 2. Front entry door not installed (onsite).
ELECTRIC-TUG 05/08/2026 APPROVED - AS NOTED JSTEWART
Note: Authorize release of email
ROOF VALLEY & METAL 05/01/2026 APPROVED JSTEWART
Note: 4/30/2026 - PREVIOUS INSPECTION NOTES Roof sheathing/braces and ties approval needed prior.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/01/2026 APPROVED - AS NOTED JSTEWART
Note: 1. Please install center gable brace per Detail A pg S4. (Currently nailed to jack truss, needs to connect to the bottom chord of gable) per plan. 2. Please install screws from under the top plate into truss above 12"OC Garage shear wall per plan. Will check at all rough. 4/30/2026 - PREVIOUS INSPECTION NOTES Not ready, anchors and tie downs incomplete.
ROOF VALLEY & METAL 04/30/2026 Disapproved - NO FEE JSTEWART
Note: Roof sheathing/braces and ties approval needed prior.
WALL SHEATHING 04/30/2026 APPROVED JSTEWART
ROOF SHEATHING / BRACES/TIES/DOWN CELL 04/30/2026 Disapproved - NO FEE JSTEWART
Note: Not ready, anchors and tie downs incomplete.
SEWER TIE IN 04/29/2026 APPROVED JSTEWART
Note: Live virtual inspection. 4/21/2026 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2060 Main water supply line from utility connection to house shut off not installed, will need to be open for inspection at either sewer tie inspection / All Rough inspection.
GRAVITY SEWER TEST 04/29/2026 APPROVED JSTEWART
Note: Live virtual inspection. 4/21/2026 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2060 Main water supply line from utility connection to house shut off not installed, will need to be open for inspection at either sewer tie inspection / All Rough inspection.
SEWER TIE IN 04/21/2026 CANCELLED BY APPLICANT JSTEWART
Note: Inspector Notes from Inspection 2060 Main water supply line from utility connection to house shut off not installed, will need to be open for inspection at either sewer tie inspection / All Rough inspection.
GRAVITY SEWER TEST 04/21/2026 CANCELLED BY APPLICANT JSTEWART
Note: Inspector Notes from Inspection 2060 Main water supply line from utility connection to house shut off not installed, will need to be open for inspection at either sewer tie inspection / All Rough inspection.
MONOLITHIC SLAB 04/16/2026 Disapproved - NO FEE JSTEWART
Note: Reinforcement requires 3" min clearence from soil. (column pads rebar is in the soil, cave ins, porch to main transitions.)
MONOLITHIC SLAB 04/16/2026 APPROVED JSTEWART
Note: Live virtual re inspect, correction made. 4/16/2026 - PREVIOUS INSPECTION NOTES Reinforcement requires 3" min clearence from soil. (column pads rebar is in the soil, cave ins, porch to main transitions.)
PLUMBING 1ST ROUGH UNDERGROUND 04/10/2026 APPROVED - AS NOTED JSTEWART
Note: Main water supply line from utility connection to house shut off not installed, will need to be open for inspection at either sewer tie inspection / All Rough inspection.
WATER METER INSTALLATION REQUEST 04/10/2026 APPROVED ISANDERSON
FORMBOARD SURVEY (OFFICE USE ONLY) 04/09/2026 APPROVED PFLANAGAN
U-CROSS CONNECTION
BLD - BUILDING FINAL
ROW - FINAL APRON (AFTER POUR)
ROW - FINAL INSPECTION
U -UTILITY RESIDENTIAL FINAL

Review History

Department Status Date In Date Out
SW1 COMPLETE 04/09/2026 04/09/2026
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON COMPLETE 04/09/2026 04/09/2026
Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM
BLD COMPLETE 03/25/2026 03/31/2026
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
CUSVC COMPLETE 03/25/2026 04/01/2026
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 03/25/2026 03/30/2026
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 03/25/2026 03/26/2026
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
GAS COMPLETE 03/25/2026 03/26/2026
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
LOCATE COMPLETE 03/25/2026 03/26/2026
Note: Released By: IVAN SANDERSON - -
MECH COMPLETE 03/25/2026 03/27/2026
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 03/25/2026 04/01/2026
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 03/25/2026 03/26/2026
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
URB COMPLETE 03/25/2026 04/01/2026
Note: Released By: JOHN BEAUDET - (386)986-2456 - JBEAUDET@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
FC IMPACT FEE EMS ¤62.00 04/08/2026
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 04/08/2026
FC IMPACT FEE LIBRARY ¤268.00 04/08/2026
FIRE RES IMPACT FEE 10-25 ¤942.00 04/08/2026
WATER METER W/OUT TAP ¤965.03 04/08/2026
PARKS IMPACT FEE 10-25 ¤3,164.00 04/08/2026
RECLAIM WATER PERMIT INSPECTIO ¤40.00 04/08/2026
RSI DRIVEWAY AFTER POUR ¤16.25 04/08/2026
RSE DRIVE PRE POUR INSPECTION ¤32.50 04/08/2026
RSI FORMBOARD REVIEW ¤16.25 04/08/2026
RSI PLAN REVIEW NEW ¤48.75 04/08/2026
RSI FNL SURVEY/GRADING CERT ¤48.75 04/08/2026
RSI ROW FINAL INSPECTION ¤16.25 04/08/2026
SCHOOL BOARD IMPACT FEE RES ¤5,450.00 04/08/2026
SURCHARGE FS 533.721 ¤10.85 04/08/2026
SURCHARGE - FS 468.631 ¤16.28 04/08/2026
TRANSP RES IMPACT FEE 10-25 ¤5,658.77 04/08/2026
WASTEWATER PERM INSPECTION ¤80.00 04/08/2026
WASTEWATER PERM REVIEW ¤25.00 04/08/2026
SEWER CAPITAL FACILITY ¤3,628.86 04/08/2026
WATER CAPITAL FACILITY FEE ¤3,091.14 04/08/2026
WATER PERMIT REVIEW ¤25.00 04/08/2026
SITE PLAN 30 ¤30.00 04/08/2026
WATER-METER ¤874.47 04/08/2026
WATER- TURN ON ¤50.00 04/08/2026
ADMINISTRATIVE RESIDENTIAL ¤30.00 04/08/2026
INSPECTION - RESIDENTIAL ¤822.25 04/08/2026
PLAN REVIEW - RESIDENTIAL ¤233.22 04/08/2026
REINSPECTION RESIDENTIAL ¤40.00
RSI REINSPECTION 1 ¤35.00
Fees Total Due: ¤75.00 Total Paid: ¤25,863.62