I want to search for...
Permit #2026031216
Permit Details
Status: INSPECT
| Parcel Id: 04-11-30-5571-00000-3470 |
| CONDITIONED SPACE: 2003 sqft |
| GARAGE: 477 sqft |
| OPENED PORCH (WITH ROOF) : 78 sqft |
| OPENED PORCH (WITH ROOF) : 112 sqft |
| Total Square Footage: 2670 sqft |
| Subdivision: 2366 - SOMERSET SUBDIVISION PH 2 |
| Job Phone: 904-596-6645 |
| Location Address: 115 GOLDEN BELL AVE |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 04/13/2026 |
| NOC: RECORDED |
| Applicant name: MICHAEL T HOLDER |
| Owner: KB HOME JACKSONVILLE LLC |
|
Address 10475 FORTUNE PARKWAY JACKSONVILLE, FL 32256 |
|
Address SUITE 100 JACKSONVILLE, FL 32256 |
| Lot: 347 |
| Contracted Stated Job Value: ¤140,000.00 |
| Job Description: SINGLE FAMILY DWELLING |
| Type: CN |
Contractor
KB HOME JACKSONVILLE, LLC
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
10475 FORTUNE PKWY JACKSONVILLE, FL 32256 |
SUITE 100 JACKSONVILLE, FL 32256 |
CGC1509034 (Exp: 08/31/2026) | 904-596-6645 |
Sub Contractors
LARRY WILLIAMS
| Status | Location Address | State License Number | Phone |
| ACTIVE |
1750 EMERSON ST JACKSONVILLE, FL 32207 |
LI45034 (Exp: 08/31/2026) | 904-721-5431 |
BOBBY WAYNE CAMPBELL
| Status | Location Address | State License Number | Phone |
| ACTIVE |
117 GUTHRIE ROAD GREEN COVE SPRINGS, FL 32043 |
CCC1326752 (Exp: 08/31/2026) | 904-200-1600 |
JAMES E LINTON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
200 COLLEGE DR ORANGE PARK, FL 32065 |
EC0001152 (Exp: 08/31/2026) | 904-272-0272 |
COREY MICHAEL TENNANT
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3370 AGRICULTURAL CNETER DR ST AUGUSTINE, FL 32092 |
CAC1819063 (Exp: 08/31/2026) | 904-829-8898 |
BENJAMIN MICHAEL RAY
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| ACTIVE |
6310 MABLETON PKWY JACKSONVILLE, FL 32216 |
SUITE 1000 MABLETON, GA 30126 |
CFC1428415 (Exp: 08/31/2026) | 904-861-5421 | 904-861-5426 |
Inspection History
| Type | Request Date | Result | Inspector |
| ROW- PRE-APRON (PRE-POUR) | 06/10/2026 | APPROVED - AS NOTED | TPOLACEK |
| Note: 06-10-26 TPOLACEK*** THERE IS A HIGH AREA UP ON THE RIGHT SIDE CLOSE TO GARAGE THAT MUST BE GRADED DOWN TO ACHIEVE 4" OF COVERAGE. ALL FORM BOARDS MUST BE EXTENDED DOWN OR BACKFILLED TO PREVENT OVER POUR . APPROVING AS NOTED AT THE TIME OF THE INSPECTION READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. . TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, IN THE UPCOMING MONTHS THE DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS WILL BE REQUIRED TO BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. YOU WILL RECEIVE A NEWS BLAST WHEN THIS BECOMES NECESSARY. | |||
| DRYWALL NAILING | 06/03/2026 | APPROVED | JSTEWART |
| Note: 6/1/2026 - PREVIOUS INSPECTION NOTES | |||
| DRYWALL NAILING | 06/01/2026 | CANCELLED BY APPLICANT | JSTEWART |
| INSULATION | 05/29/2026 | APPROVED | JSTEWART |
| Note: 5/27/2026 - PREVIOUS INSPECTION NOTES Previous Note not rectified.......Electric feed (under slab) from Island to refridgerator space is not ran or tied in, Conduit will need to be relocated into the wall line currently in refridgerator floor space. Inspector Notes from Inspection 2420 1. Power for the island is not ran. Note- Gas rough ok. Inspector Notes from Inspection 2460 Shearwall at garage please nail truss to top plate backing 4"OC per SD-3 detail GG. 5/15/2026 - PREVIOUS INSPECTION NOTES Not ready on engineering, pulled a roof sheathing inspection for roof. | |||
| INSULATION | 05/27/2026 | Disapproved - NO FEE | JSTEWART |
| Note: Previous Note not rectified.......Electric feed (under slab) from Island to refridgerator space is not ran or tied in, Conduit will need to be relocated into the wall line currently in refridgerator floor space. Inspector Notes from Inspection 2420 1. Power for the island is not ran. Note- Gas rough ok. Inspector Notes from Inspection 2460 Shearwall at garage please nail truss to top plate backing 4"OC per SD-3 detail GG. 5/15/2026 - PREVIOUS INSPECTION NOTES Not ready on engineering, pulled a roof sheathing inspection for roof. | |||
| ELECTRIC-TUG | 05/22/2026 | APPROVED | RMARTIN |
| LATH/BRICK/ WATER BARRIER | 05/22/2026 | APPROVED | HCAMACHO |
| Note: Inspector Notes from Inspection 2460 Shearwall at garage please nail truss to top plate backing 4"OC per SD-3 detail GG. 5/15/2026 - PREVIOUS INSPECTION NOTES Not ready on engineering, pulled a roof sheathing inspection for roof. | |||
| ALL ROUGH | 05/22/2026 | APPROVED - AS NOTED | HCAMACHO |
| Note: 1. Power for the island is not ran. Note- Gas rough ok. Inspector Notes from Inspection 2460 Shearwall at garage please nail truss to top plate backing 4"OC per SD-3 detail GG. 5/15/2026 - PREVIOUS INSPECTION NOTES Not ready on engineering, pulled a roof sheathing inspection for roof. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 05/18/2026 | APPROVED - AS NOTED | JSTEWART |
| Note: Shearwall at garage please nail truss to top plate backing 4"OC per SD-3 detail GG. 5/15/2026 - PREVIOUS INSPECTION NOTES Not ready on engineering, pulled a roof sheathing inspection for roof. | |||
| ROOF SHEATHING | 05/15/2026 | APPROVED - AS NOTED | JSTEWART |
| Note: roof sheathing only | |||
| ROOF VALLEY & METAL | 05/15/2026 | APPROVED | JSTEWART |
| WALL SHEATHING | 05/15/2026 | APPROVED | JSTEWART |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 05/15/2026 | Disapproved - NO FEE | JSTEWART |
| Note: Not ready on engineering, pulled a roof sheathing inspection for roof. | |||
| GRAVITY SEWER TEST | 05/05/2026 | APPROVED - AS NOTED | MCONTRYMAN |
| Note: 5/5/26 Via virtual --Main supply was hooked into meter at time of virtual inspection Main water supply line from utility connection to house shut off not installed, will need to be open for inspection at either sewer tie inspection / All Rough inspection | |||
| SEWER TIE IN | 05/05/2026 | APPROVED - AS NOTED | MCONTRYMAN |
| Note: 5/5/26 Via virtual --Main supply was hooked into meter at time of virtual inspection Main water supply line from utility connection to house shut off not installed, will need to be open for inspection at either sewer tie inspection / All Rough inspection | |||
| MONOLITHIC SLAB | 05/01/2026 | APPROVED | JSTEWART |
| Note: 4/30/2026 - PREVIOUS INSPECTION NOTES At the front on both side of the home, there shall be a minimum of 23 inches from the top of the formboard to the bottom of the footer. to maintain 12" of footing below finished grade. R403.1.4 | |||
| MONOLITHIC SLAB | 04/30/2026 | Disapproved - NO FEE | JSTEWART |
| Note: At the front on both side of the home, there shall be a minimum of 23 inches from the top of the formboard to the bottom of the footer. to maintain 12" of footing below finished grade. R403.1.4 | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 04/24/2026 | APPROVED | JSTEWART |
| Note: *** NOTES ADDED BY JSTEWART 4/24/2026 2:13:44 PM *** Main water supply line from utility connection to house shut off not installed, will need to be open for inspection at either sewer tie inspection / All Rough inspection | |||
| FORMBOARD SURVEY (OFFICE USE ONLY) | 04/23/2026 | APPROVED | PFLANAGAN |
| WATER METER INSTALLATION REQUEST | 04/15/2026 | APPROVED | ISANDERSON |
| U-CROSS CONNECTION | |||
| BLD - BUILDING FINAL | |||
| ROW - FINAL APRON (AFTER POUR) | |||
| ROW - FINAL INSPECTION | |||
| U -UTILITY RESIDENTIAL FINAL | |||
| ELECTRIC - EARLY POWER |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 04/23/2026 | 04/23/2026 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 04/23/2026 | 04/23/2026 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 03/31/2026 | 04/07/2026 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 03/31/2026 | 04/07/2026 |
| Note: Released By: CYNTHIA SCHWEERS - - CSCHWEERS@PALMCOASSTGOV.COM | |||
| ELEC | COMPLETE | 03/31/2026 | 04/06/2026 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 03/31/2026 | 04/01/2026 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| GAS | COMPLETE | 03/31/2026 | 04/01/2026 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 03/31/2026 | 04/02/2026 |
| Note: Released By: IVAN SANDERSON - - | |||
| MECH | COMPLETE | 03/31/2026 | 04/02/2026 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 03/31/2026 | 04/07/2026 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 03/31/2026 | 04/02/2026 |
| Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM | |||
| URB | COMPLETE | 03/31/2026 | 04/08/2026 |
| Note: Released By: JOHN BEAUDET - (386)986-2456 - JBEAUDET@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| WATER-METER | ¤874.47 | 04/13/2026 |
| WATER- TURN ON | ¤50.00 | 04/13/2026 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 04/13/2026 |
| INSPECTION - RESIDENTIAL | ¤1,069.75 | 04/13/2026 |
| PLAN REVIEW - RESIDENTIAL | ¤303.42 | 04/13/2026 |
| FC IMPACT FEE EMS | ¤62.00 | 04/13/2026 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 04/13/2026 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 04/13/2026 |
| FIRE RES IMPACT FEE 10-25 | ¤942.00 | 04/13/2026 |
| WATER METER W/OUT TAP | ¤965.03 | 04/13/2026 |
| PARKS IMPACT FEE 10-25 | ¤3,164.00 | 04/13/2026 |
| RECLAIM WATER PERMIT INSPECTIO | ¤40.00 | 04/13/2026 |
| RSI DRIVEWAY AFTER POUR | ¤16.25 | 04/13/2026 |
| RSE DRIVE PRE POUR INSPECTION | ¤32.50 | 04/13/2026 |
| RSI FORMBOARD REVIEW | ¤16.25 | 04/13/2026 |
| RSI PLAN REVIEW NEW | ¤48.75 | 04/13/2026 |
| RSI FNL SURVEY/GRADING CERT | ¤48.75 | 04/13/2026 |
| RSI ROW FINAL INSPECTION | ¤16.25 | 04/13/2026 |
| SCHOOL BOARD IMPACT FEE RES | ¤5,450.00 | 04/13/2026 |
| SURCHARGE FS 533.721 | ¤14.03 | 04/13/2026 |
| SURCHARGE - FS 468.631 | ¤21.05 | 04/13/2026 |
| TRANSP RES IMPACT FEE 10-25 | ¤7,551.31 | 04/13/2026 |
| WASTEWATER PERM INSPECTION | ¤80.00 | 04/13/2026 |
| WASTEWATER PERM REVIEW | ¤25.00 | 04/13/2026 |
| SEWER CAPITAL FACILITY | ¤3,628.86 | 04/13/2026 |
| WATER CAPITAL FACILITY FEE | ¤3,091.14 | 04/13/2026 |
| WATER PERMIT REVIEW | ¤25.00 | 04/13/2026 |
| SITE PLAN 30 | ¤30.00 | 04/13/2026 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤28,081.81 |