I want to search for...

Permit #2026040055

Permit Details

Status: INSPECT

Parcel Id: 21-12-31-5560-00000-1140
CONDITIONED SPACE: 2046 sqft
GARAGE: 470 sqft
OPENED PORCH (WITH ROOF) : 202 sqft
Total Square Footage: 2718 sqft
Subdivision: 2336 - SEMINOLE PALMS SUBDIVISION PHASE 1
Job Phone: 407-717-5418
Location Address: 252 MONTGOMERY CT
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 04/16/2026
NOC: RECORDED
Applicant name: CARLOS ANTONIO SERRANO
Owner: NVR INC

Address

10210 HIGHLAND MANOR DRIVE SUITE 300

TAMPA, FL 33610

Lot: 114
Contracted Stated Job Value: ¤184,967.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

RYAN HOMES
Status Location Address Mailing Address State License Number Phone
ACTIVE

8649 BAYPINE RD

JACKSONVILLE, FL 32256

BLDG 7, STE 202

JACKSONVILLE, FL 32256

CBC1256450 (Exp: 08/31/2026) 407-717-5418

Sub Contractors

JOSEPH H STRADA JR
Status Location Address State License Number Phone
ACTIVE

3400 ST JOHNS PKWY

SANFORD, FL 32771

CAC043953 (Exp: 08/31/2026) 877-906-1113
JOSEPH H STRADA JR
Status Location Address State License Number Phone
ACTIVE

3400 ST JOHNS PKWY

SANFORD, FL 32771

CAC043953 (Exp: 08/31/2026) 877-906-1113
BRITT MICHAEL JENKINS
Status Location Address State License Number Phone
ACTIVE

86 COLUMBIA DR

POOLER, GA 31322

CFC1430770 (Exp: 08/31/2026) 912-330-8151
JACK DOUGLAS LANIER
Status Location Address State License Number Phone Fax
ACTIVE

485 COMMERCE WAY

LONGWOOD , FL 32750

CCC058022 (Exp: 08/31/2026) (321)441-2300 (321)441-2313

Inspection History

Type Request Date Result Inspector
DRYWALL NAILING 06/04/2026 APPROVED RSIMS
Note: New inspection due to canceled inspection 6/2/2026 - PREVIOUS INSPECTION NOTES 6/2/26: 1). Front entry porch ceiling has a strip/piece of drywall that is not rated soffit as required. FBC-R702.3.7 2). Back Lanai ceiling has multiple pieces of drywall that is not rated soffit as required. FBC-R702.3.7
DRYWALL NAILING 06/03/2026 CANCELLED BY APPLICANT WEB
Note: 6/2/2026 - PREVIOUS INSPECTION NOTES 6/2/26: 1). Front entry porch ceiling has a strip/piece of drywall that is not rated soffit as required. FBC-R702.3.7 2). Back Lanai ceiling has multiple pieces of drywall that is not rated soffit as required. FBC-R702.3.7
DRYWALL NAILING 06/02/2026 Disapproved - NO FEE RSIMS
Note: 6/2/26: 1). Front entry porch ceiling has a strip/piece of drywall that is not rated soffit as required. FBC-R702.3.7 2). Back Lanai ceiling has multiple pieces of drywall that is not rated soffit as required. FBC-R702.3.7
INSULATION 05/29/2026 APPROVED RSIMS
Note: 5/27/2026 - PREVIOUS INSPECTION NOTES 5/27/26: 1). Firestop for low voltage wires in garage is missing. FS written below area. FBC-R302.11 2). 2nd floor left side bathroom: plumbing stack pipe is missing firestop at top plate. FS on stud. FBC-R302.11 3). 3 concealed chase areas: 1/2" plywood does not meet minimum thickness of 1-1/2" for wood fireblocking. FBC-R302.11.1 NOTE: Concrete slab repair at powder room (just inside garage door). needs to be complete prior to approved insulation inspection.
INSULATION 05/27/2026 Disapproved - NO FEE RSIMS
Note: 5/27/26: 1). Firestop for low voltage wires in garage is missing. FS written below area. FBC-R302.11 2). 2nd floor left side bathroom: plumbing stack pipe is missing firestop at top plate. FS on stud. FBC-R302.11 3). 3 concealed chase areas: 1/2" plywood does not meet minimum thickness of 1-1/2" for wood fireblocking. FBC-R302.11.1 NOTE: Concrete slab repair at powder room (just inside garage door). needs to be complete prior to approved insulation inspection.
ALL ROUGH 05/26/2026 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 5/26/2026 2:32:02 PM *** 5/26/26: Main underground water service piping is installed from house to meter location and a pressure test has been applied. Piping is Inspected and approved. No Meter Valve installed yet. Inspector Notes from Inspection 2420 5/19/26: Check at Insulation Inspection 1). Lanai SGD and second floor right side front windows are not installed as of today's inspection. FBC-[A] 107.4 / FBC [A]110.1 2). No 5ft head pressure. FBC-P2503.5.1 3). Kitchen exhaust needs the three evenly spaced screws at each joint/connection. FBC-M1601.4.1 4). Bonding wire for metal outlet box at security panel needs to be installed at this inspection. NEC-250.148(C)
LATH/BRICK/ WATER BARRIER 05/22/2026 APPROVED RSIMS
Note: Inspector Notes from Inspection 2420 5/19/26: Check at Insulation Inspection 1). Lanai SGD and second floor right side front windows are not installed as of today's inspection. FBC-[A] 107.4 / FBC [A]110.1 2). No 5ft head pressure. FBC-P2503.5.1 3). Kitchen exhaust needs the three evenly spaced screws at each joint/connection. FBC-M1601.4.1 4). Bonding wire for metal outlet box at security panel needs to be installed at this inspection. NEC-250.148(C)
ALL ROUGH 05/19/2026 APPROVED - AS NOTED RSIMS
Note: 5/19/26: Check at Insulation Inspection 1). Lanai SGD and second floor right side front windows are not installed as of today's inspection. FBC-[A] 107.4 / FBC [A]110.1 2). No 5ft head pressure. FBC-P2503.5.1 3). Kitchen exhaust needs the three evenly spaced screws at each joint/connection. FBC-M1601.4.1 4). Bonding wire for metal outlet box at security panel needs to be installed at this inspection. NEC-250.148(C)
ELECTRIC-TUG 05/13/2026 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 5/13/2026 1:23:42 PM *** 5/13/26: FPL emailed > Approved for TUG.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/13/2026 APPROVED RSIMS
Note: Inspector Notes from Inspection 2450 *** NOTES ADDED BY RSIMS 5/8/2026 2:47:07 PM *** 5/8/26: Check at next inspection. Do not cover with water barrier until correction is confirmed complete. 1). Please make sure that nails are fully sunk as required. (FBC-R404.2.6 Fastening). Inspector Notes from Inspection 2250 *** NOTES ADDED BY RSIMS 4/24/2026 12:07:18 PM *** Please have termite intent to treat in permit box prior to next inspection.
ROOF VALLEY & METAL 05/13/2026 APPROVED RSIMS
Note: Inspector Notes from Inspection 2450 *** NOTES ADDED BY RSIMS 5/8/2026 2:47:07 PM *** 5/8/26: Check at next inspection. Do not cover with water barrier until correction is confirmed complete. 1). Please make sure that nails are fully sunk as required. (FBC-R404.2.6 Fastening). Inspector Notes from Inspection 2250 *** NOTES ADDED BY RSIMS 4/24/2026 12:07:18 PM *** Please have termite intent to treat in permit box prior to next inspection.
WALL SHEATHING 05/08/2026 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 5/8/2026 2:47:07 PM *** 5/8/26: Check at next inspection. Do not cover with water barrier until correction is confirmed complete. 1). Please make sure that nails are fully sunk as required. (FBC-R404.2.6 Fastening). Inspector Notes from Inspection 2250 *** NOTES ADDED BY RSIMS 4/24/2026 12:07:18 PM *** Please have termite intent to treat in permit box prior to next inspection.
SEWER TIE IN 04/27/2026 APPROVED HCAMACHO
Note: 4/22/2026 - PREVIOUS INSPECTION NOTES 4/22/26: Waiting for virtual verification of sewer tie-in. dirt has caved in obscuring the connection. Builder / Plumber unable to complete today. FBC-P2503.4
MONOLITHIC SLAB 04/24/2026 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 4/24/2026 12:07:18 PM *** Please have termite intent to treat in permit box prior to next inspection.
PLUMBING 1ST ROUGH UNDERGROUND 04/22/2026 APPROVED - AS NOTED RSIMS
Note: *** NOTES ADDED BY RSIMS 4/22/2026 12:55:34 PM *** Waiting for virtual verification of Lineset sleeve as required on 1st floor plumbing plan. Virtually approved via FaceTime video/audio phone app at @ 1250.
GRAVITY SEWER TEST 04/22/2026 APPROVED RSIMS
Note: *** NOTES ADDED BY RSIMS 4/22/2026 11:49:44 AM *** Approved
SEWER TIE IN 04/22/2026 Disapproved - NO FEE RSIMS
Note: *** NOTES ADDED BY RSIMS 4/22/2026 3:26:54 PM *** 4/22/26: Waiting for virtual verification of sewer tie-in. dirt has caved in obscuring the connection. Builder / Plumber unable to complete today. FBC-P2503.4
FORMBOARD SURVEY (OFFICE USE ONLY) 04/21/2026 APPROVED RRICKS
WATER METER INSTALLATION REQUEST 04/17/2026
PEP TANK INSTALLATION REQUEST
U-CROSS CONNECTION
ROW- PRE-APRON (PRE-POUR)
ROW - FINAL APRON (AFTER POUR)
ROW - FINAL INSPECTION
U -UTILITY RESIDENTIAL FINAL
BLD - BUILDING FINAL
ELECTRIC - EARLY POWER

Review History

Department Status Date In Date Out
SW1 COMPLETE 04/21/2026 04/21/2026
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
ZON COMPLETE 04/21/2026 04/21/2026
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
SW1 HOLD 04/20/2026 04/21/2026
Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM No becnhmark on formboard survey.
ZON COMPLETE 04/20/2026 04/20/2026
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
ZON COMPLETE 04/13/2026 04/14/2026
Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM
SW1 COMPLETE 04/13/2026 04/14/2026
Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM
BLD COMPLETE 04/01/2026 04/08/2026
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
CUSVC COMPLETE 04/01/2026 04/07/2026
Note: Released By: CYNTHIA SCHWEERS - - CSCHWEERS@PALMCOASSTGOV.COM
ELEC COMPLETE 04/01/2026 04/06/2026
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 04/01/2026 04/02/2026
Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM
GAS CANCEL 04/01/2026 04/02/2026
LOCATE COMPLETE 04/01/2026 04/02/2026
Note: Released By: IVAN SANDERSON - -
MECH COMPLETE 04/01/2026 04/02/2026
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 HOLD 04/01/2026 04/08/2026
Note: Held By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM Please provide a benchmark on grading plan.
ZON HOLD 04/01/2026 04/02/2026
Note: Held By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM Color material sheet need to use updated one and can be found at https://copc-strapi-production.s3.amazonaws.com/Color_and_Materials_Sheet_Rev_9_2_25_624256e182.pdf
URB COMPLETE 04/01/2026 04/09/2026
Note: Released By: JOHN BEAUDET - (386)986-2456 - JBEAUDET@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
WATER-METER ¤874.47 04/16/2026
WATER- TURN ON ¤50.00 04/16/2026
ADMINISTRATIVE RESIDENTIAL ¤30.00 04/16/2026
INSPECTION - RESIDENTIAL ¤1,091.75 04/16/2026
PLAN REVIEW - RESIDENTIAL ¤309.66 04/16/2026
FC IMPACT FEE EMS ¤62.00 04/16/2026
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 04/16/2026
FC IMPACT FEE LIBRARY ¤268.00 04/16/2026
FIRE RES IMPACT FEE 10-25 ¤942.00 04/16/2026
WATER METER W/OUT TAP ¤965.03 04/16/2026
PARKS IMPACT FEE 10-25 ¤3,164.00 04/16/2026
RECLAIM WATER PERMIT INSPECTIO ¤40.00 04/16/2026
RSI DRIVEWAY AFTER POUR ¤16.25 04/16/2026
RSE DRIVE PRE POUR INSPECTION ¤32.50 04/16/2026
RSI FORMBOARD REVIEW ¤16.25 04/16/2026
RSI PLAN REVIEW NEW ¤48.75 04/16/2026
RSI FNL SURVEY/GRADING CERT ¤48.75 04/16/2026
RSI ROW FINAL INSPECTION ¤16.25 04/16/2026
SURCHARGE FS 533.721 ¤14.31 04/16/2026
SURCHARGE - FS 468.631 ¤21.47 04/16/2026
TRANSP RES IMPACT FEE 10-25 ¤7,713.42 04/16/2026
TRANSP RES IMPACT FEE 10-25 (¤7,713.42) 04/16/2026
WASTEWATER PERM INSPECTION ¤80.00 04/16/2026
WASTEWATER PERM REVIEW ¤25.00 04/16/2026
SEWER CAPITAL FACILITY ¤2,368.69 04/16/2026
WATER CAPITAL FACILITY FEE ¤1,744.18 04/16/2026
WATER PERMIT REVIEW ¤25.00 04/16/2026
SITE PLAN 30 ¤30.00 04/16/2026
Fees Total Due: ¤0.00 Total Paid: ¤12,502.31