I want to search for...
Permit #2026040061
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7023-00110-0040 |
| Block: 00110 |
| Subdivision: 2191 - SECTION 23-WYNNFIELD |
| Job Phone: 305-878-9095 |
| Location Address: 50 WHISPERING PINE DR |
| Type: PO - POOL |
| Issue Date: 04/10/2026 |
| NOC: RECORDED |
| Applicant name: DILLON MICHAEL ROBLES |
| Owner: TICE SEAN & MONICA H&W |
|
Address 50 WHISPERING PINE DRIVE PALM COAST, FL 32164 |
| Lot: 0040 |
| Contracted Stated Job Value: ¤62,985.00 |
| Job Description: FIBERGLASS POOL |
| Type: CN |
Contractor
PELICAN POOLS LLC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
14 MALAGA COURT PALM COAST, FL 32137 |
CPC1461204 (Exp: 08/31/2028) | 305-431-5409 |
Sub Contractors
RICHARD R EDWARDS
| Status | Location Address | State License Number | Phone |
| ACTIVE |
P. O. Box 1637 Bunnell, FL 32110 |
EC13010654 (Exp: 08/31/2026) | (386) 437-1537 |
Inspection History
| Type | Request Date | Result | Inspector |
| POOL FINAL | 06/08/2026 | FINAL APPROVED | HCAMACHO |
| ROW - FINAL INSPECTION | 06/05/2026 | APPROVED | FSLADISH |
| Note: 6/5/26 AT THE TIME OF THE INSPECTION ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. Inspector Notes from Inspection 9465 6/4/26 WHILE WALKING PROPERTY THERE WAS AN IRRIGATION COMPANY INSTALLING PIPE AND SOS IS REMOVED IN DRAINAGE CONVEYANCE. I AM APPROVING THIS FIELD SURVEY AS NOTED THAT GRADE APPEARS TO MEET MINIMUM COPC STANDARDS BUT I WILL BE HOLDING THE FINAL UNTIL IRRIGATION INSTALLATION IS COMPLETE TO MAKE SURE POSITIVE FORWARD DRAINAGE IS MAINTAINED. TPOLACEK*** WALKED SITE AND AT THE TIME OF INSPECTION THE DRAINAGE SHOULD WORK AS INDICATED. THE FINAL SURVEY WAS MISSING FFE OF POOL DECK AND PATIO | |||
| U -UTILITY RESIDENTIAL FINAL | 06/05/2026 | APPROVED | TLOWE |
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 06/04/2026 | APPROVED | FSLADISH |
| Note: 6/4/26 REQUIRED CORRECTIONS COMPLETED. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 06/04/2026 | APPROVED - AS NOTED | FSLADISH |
| Note: 6/4/26 WHILE WALKING PROPERTY THERE WAS AN IRRIGATION COMPANY INSTALLING PIPE AND SOS IS REMOVED IN DRAINAGE CONVEYANCE. I AM APPROVING THIS FIELD SURVEY AS NOTED THAT GRADE APPEARS TO MEET MINIMUM COPC STANDARDS BUT I WILL BE HOLDING THE FINAL UNTIL IRRIGATION INSTALLATION IS COMPLETE TO MAKE SURE POSITIVE FORWARD DRAINAGE IS MAINTAINED. TPOLACEK*** WALKED SITE AND AT THE TIME OF INSPECTION THE DRAINAGE SHOULD WORK AS INDICATED. THE FINAL SURVEY WAS MISSING FFE OF POOL DECK AND PATIO | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 05/29/2026 | Disapproved - NO FEE | TPOLACEK |
| Note: 05-29-26 TPOLACEK** FINAL SURVEY MUST INCLUDE FFE OF POOL AND PATIO. PLEASE UPDATE SURVEY. | |||
| ELECTRIC AND ALARM | 05/28/2026 | APPROVED - AS NOTED | HCAMACHO |
| Note: 1. Please make sure the latches on the fence are at 54" and the gates close automatically. FBC R4501.17 | |||
| ROW- PROJECT STATUS | 05/18/2026 | Status Check | PFLANAGAN |
| Note: Talked to Dillon and told him to grade to the front due to lots behind this lot. ---------------------------------------------------------------------------------------------- 5/18/26=Dilan from the pool company called me asking if they could move the water flow to the back of the property. I explained that they cannot do that because it is private property. I reviewed the old final survey, and it showed that the water was already flowing toward the back. Please make sure the houses on the sides are directing the water properly as well. per GBERTOLA. PPLEASE CONTACT THE BUILDER FOR YOUR DECISION. THANK YOU. | |||
| SUBGRADE - FIBERGLASS POOL | 05/01/2026 | APPROVED | HCAMACHO |
| POOL DECK | 05/01/2026 | APPROVED | HCAMACHO |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 05/01/2026 | 05/04/2026 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| RSI | COMPLETE | 05/01/2026 | 05/06/2026 |
| Note: Released By: EDWARD MADISON - (386)986-4770 - EMADISON@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 05/01/2026 | 05/06/2026 |
| Note: Released By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 04/08/2026 | 04/09/2026 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 04/08/2026 | 04/09/2026 |
| Note: Released By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM | |||
| RSI | COMPLETE | 04/08/2026 | 04/10/2026 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| BFLOOD | CANCEL | 04/01/2026 | 04/02/2026 |
| BLD | COMPLETE | 04/01/2026 | 04/08/2026 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 04/01/2026 | 04/06/2026 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | HOLD | 04/01/2026 | 04/02/2026 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Manufacturers specs showas a pool heater. Revise TDH | |||
| RSI | COMPLETE | 04/01/2026 | 04/08/2026 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM Note to contractor that the drainage must meet city standards before pool permit is closed. | |||
| ZON | HOLD | 04/01/2026 | 04/02/2026 |
| Note: Held By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM Site plan missing rear setback Site plan need to show the location of the fence Site plan needs to show equip pad set backs |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| PLAN REVIEW - REVISION | ¤32.50 | 05/07/2026 |
| RSI FIELD SURVEY INSPECTION | ¤48.75 | 04/10/2026 |
| RSI PLAN REVIEW NEW | ¤48.75 | 04/10/2026 |
| RSI FNL SURVEY/GRADING CERT | ¤48.75 | 04/10/2026 |
| RSI ROW FINAL INSPECTION | ¤16.25 | 04/10/2026 |
| SURCHARGE FS 533.721 | ¤2.55 | 04/10/2026 |
| SURCHARGE - FS 468.631 | ¤3.83 | 04/10/2026 |
| SITE PLAN 30 | ¤30.00 | 04/10/2026 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 04/10/2026 |
| INSPECTION- POOL | ¤160.00 | 04/10/2026 |
| PLAN REVIEW - RESIDENTIAL | ¤65.00 | 04/10/2026 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤486.38 |