Permit #2026040393

Permit Details

Status: INSPECT

Parcel Id: 07-11-31-7035-01450-0160
Block: 01450
Subdivision: 2172 - SECTION 35-BELLE TERRE
Location Address: 205 BIRCHWOOD DR
Type: PL - PLUMBING
Issue Date: 04/16/2026
NOC: RECORDED
Applicant name: DANIEL J MCHUGH
Owner: MARAVIGLIA FRANK A & EILEEN V H&W

Address

205 BIRCHWOOD DRIVE

PALM COAST, FL 32137

Lot: 0160
Contracted Stated Job Value: ¤13,841.00
Job Description: Whole Home Water Repipe
Type: CN

Contractor

BENJAMIN FRANKLIN PLUMBING
Status Location Address Mailing Address State License Number
ACTIVE

440 STAND DR

MELBORUNE, FL 32904

STE 101

MELBORUNE, FL 32904

CFC1429175 (Exp: 08/31/2026)

Inspection History

Type Request Date Result Inspector
PLUMBING FINAL 05/27/2026 Disapproved -FEE REQUIRED JSTEWART
Note: 1. Laundry room drywall patches need to be taped and sealed. Shared wall to garage) FBC R302.6 & Table R302.6 / FBPC 307.1 2. Garage wall penetrations at the water heater need to be sealed. FBC R302.6 & Table R302.6 / FBC P2606.1 5/26/2026 - PREVIOUS INSPECTION NOTES 1. Arrived at 11:15 and there was no answer at the door.FBC[A] 110.5 ACCESS FOR INSPECTION - SPECIAL INSTRUCTIONS Inspector Notes from Inspection 2070 Added a Insulation Inspection, for all top plate Penetrations to be firestopped with fire foam. FBC R302.11(4) Will need to be approved prior to drywall nailing inspection.
PLUMBING FINAL 05/26/2026 Disapproved - NO FEE HCAMACHO
Note: 1. Arrived at 11:15 and there was no answer at the door.FBC[A] 110.5 ACCESS FOR INSPECTION - SPECIAL INSTRUCTIONS Inspector Notes from Inspection 2070 Added a Insulation Inspection, for all top plate Penetrations to be firestopped with fire foam. FBC R302.11(4) Will need to be approved prior to drywall nailing inspection.
DRYWALL NAILING 05/22/2026 APPROVED MCONTRYMAN
INSULATION 05/19/2026 APPROVED JSTEWART
Note: 5/8/2026 - PREVIOUS INSPECTION NOTES Previous Notes not rectified.....For all top plate Penetrations, require to be Firestopped with fire foam. ****Please firestop at the following locations at the penetrations of the top plate.......Master Bath shower. Laundry (Pipe insulation not sufficient), Breakfast Nook fir strip was removed will require a Nail shield then firestop of the annular space. FBC R302.11(4) Note: Other locations have what appears to be insulation foam not fire rated foam, please remove and replace with correct fire blocking. (if the white foam is fire rated please leave the empty can onsite for verification). For all top plate Penetrations, require to be Firestopped with fire foam.
INSULATION 05/08/2026 Disapproved -FEE REQUIRED JSTEWART
Note: Previous Notes not rectified.....For all top plate Penetrations, require to be Firestopped with fire foam. ****Please firestop at the following locations at the penetrations of the top plate.......Master Bath shower. Laundry (Pipe insulation not sufficient), Breakfast Nook fir strip was removed will require a Nail shield then firestop of the annular space. FBC R302.11(4) Note: Other locations have what appears to be insulation foam not fire rated foam, please remove and replace with correct fire blocking. (if the white foam is fire rated please leave the empty can onsite for verification). For all top plate Penetrations, require to be Firestopped with fire foam.
PLUMBING 2ND ROUGH 04/30/2026 CANCELLED BY APPLICANT WEB
PLUMBING 2ND ROUGH 04/30/2026 APPROVED - AS NOTED JSTEWART
Note: Added a Insulation Inspection, for all top plate Penetrations to be firestopped with fire foam. FBC R302.11(4) Will need to be approved prior to drywall nailing inspection.
PLUMBING FINAL
Note: 5/27/2026 - PREVIOUS INSPECTION NOTES 1. Laundry room drywall patches need to be taped and sealed. Shared wall to garage) FBC R302.6 & Table R302.6 / FBPC 307.1 2. Garage wall penetrations at the water heater need to be sealed. FBC R302.6 & Table R302.6 / FBC P2606.1 5/26/2026 - PREVIOUS INSPECTION NOTES 1. Arrived at 11:15 and there was no answer at the door.FBC[A] 110.5 ACCESS FOR INSPECTION - SPECIAL INSTRUCTIONS Inspector Notes from Inspection 2070 Added a Insulation Inspection, for all top plate Penetrations to be firestopped with fire foam. FBC R302.11(4) Will need to be approved prior to drywall nailing inspection.

Review History

Department Status Date In Date Out
BADMIN COMPLETE 04/14/2026 04/14/2026
Note: Released By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM
BADMIN HOLD 04/09/2026 04/09/2026
Note: Held By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM Lien law missing job value greater than $5000.00
PLUM COMPLETE 04/08/2026 04/09/2026
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 05/21/2026
ADMINISTRATIVE RESIDENTIAL ¤30.00 04/16/2026
INSPECTION - PLUMBING ¤60.00 04/16/2026
PLAN REVIEW - MISC 32.50 ¤32.50 04/16/2026
SURCHARGE FS 533.721 ¤2.00 04/16/2026
SURCHARGE - FS 468.631 ¤2.00 04/16/2026
REINSPECTION RESIDENTIAL ¤40.00
Fees Total Due: ¤40.00 Total Paid: ¤166.50