Permit #2026040393
Permit Details
Status: INSPECT
| Parcel Id: 07-11-31-7035-01450-0160 |
| Block: 01450 |
| Subdivision: 2172 - SECTION 35-BELLE TERRE |
| Location Address: 205 BIRCHWOOD DR |
| Type: PL - PLUMBING |
| Issue Date: 04/16/2026 |
| NOC: RECORDED |
| Applicant name: DANIEL J MCHUGH |
| Owner: MARAVIGLIA FRANK A & EILEEN V H&W |
|
Address 205 BIRCHWOOD DRIVE PALM COAST, FL 32137 |
| Lot: 0160 |
| Contracted Stated Job Value: ¤13,841.00 |
| Job Description: Whole Home Water Repipe |
| Type: CN |
Contractor
BENJAMIN FRANKLIN PLUMBING
| Status | Location Address | Mailing Address | State License Number |
| ACTIVE |
440 STAND DR MELBORUNE, FL 32904 |
STE 101 MELBORUNE, FL 32904 |
CFC1429175 (Exp: 08/31/2026) |
Inspection History
| Type | Request Date | Result | Inspector |
| PLUMBING FINAL | 05/27/2026 | Disapproved -FEE REQUIRED | JSTEWART |
| Note: 1. Laundry room drywall patches need to be taped and sealed. Shared wall to garage) FBC R302.6 & Table R302.6 / FBPC 307.1 2. Garage wall penetrations at the water heater need to be sealed. FBC R302.6 & Table R302.6 / FBC P2606.1 5/26/2026 - PREVIOUS INSPECTION NOTES 1. Arrived at 11:15 and there was no answer at the door.FBC[A] 110.5 ACCESS FOR INSPECTION - SPECIAL INSTRUCTIONS Inspector Notes from Inspection 2070 Added a Insulation Inspection, for all top plate Penetrations to be firestopped with fire foam. FBC R302.11(4) Will need to be approved prior to drywall nailing inspection. | |||
| PLUMBING FINAL | 05/26/2026 | Disapproved - NO FEE | HCAMACHO |
| Note: 1. Arrived at 11:15 and there was no answer at the door.FBC[A] 110.5 ACCESS FOR INSPECTION - SPECIAL INSTRUCTIONS Inspector Notes from Inspection 2070 Added a Insulation Inspection, for all top plate Penetrations to be firestopped with fire foam. FBC R302.11(4) Will need to be approved prior to drywall nailing inspection. | |||
| DRYWALL NAILING | 05/22/2026 | APPROVED | MCONTRYMAN |
| INSULATION | 05/19/2026 | APPROVED | JSTEWART |
| Note: 5/8/2026 - PREVIOUS INSPECTION NOTES Previous Notes not rectified.....For all top plate Penetrations, require to be Firestopped with fire foam. ****Please firestop at the following locations at the penetrations of the top plate.......Master Bath shower. Laundry (Pipe insulation not sufficient), Breakfast Nook fir strip was removed will require a Nail shield then firestop of the annular space. FBC R302.11(4) Note: Other locations have what appears to be insulation foam not fire rated foam, please remove and replace with correct fire blocking. (if the white foam is fire rated please leave the empty can onsite for verification). For all top plate Penetrations, require to be Firestopped with fire foam. | |||
| INSULATION | 05/08/2026 | Disapproved -FEE REQUIRED | JSTEWART |
| Note: Previous Notes not rectified.....For all top plate Penetrations, require to be Firestopped with fire foam. ****Please firestop at the following locations at the penetrations of the top plate.......Master Bath shower. Laundry (Pipe insulation not sufficient), Breakfast Nook fir strip was removed will require a Nail shield then firestop of the annular space. FBC R302.11(4) Note: Other locations have what appears to be insulation foam not fire rated foam, please remove and replace with correct fire blocking. (if the white foam is fire rated please leave the empty can onsite for verification). For all top plate Penetrations, require to be Firestopped with fire foam. | |||
| PLUMBING 2ND ROUGH | 04/30/2026 | CANCELLED BY APPLICANT | WEB |
| PLUMBING 2ND ROUGH | 04/30/2026 | APPROVED - AS NOTED | JSTEWART |
| Note: Added a Insulation Inspection, for all top plate Penetrations to be firestopped with fire foam. FBC R302.11(4) Will need to be approved prior to drywall nailing inspection. | |||
| PLUMBING FINAL | |||
| Note: 5/27/2026 - PREVIOUS INSPECTION NOTES 1. Laundry room drywall patches need to be taped and sealed. Shared wall to garage) FBC R302.6 & Table R302.6 / FBPC 307.1 2. Garage wall penetrations at the water heater need to be sealed. FBC R302.6 & Table R302.6 / FBC P2606.1 5/26/2026 - PREVIOUS INSPECTION NOTES 1. Arrived at 11:15 and there was no answer at the door.FBC[A] 110.5 ACCESS FOR INSPECTION - SPECIAL INSTRUCTIONS Inspector Notes from Inspection 2070 Added a Insulation Inspection, for all top plate Penetrations to be firestopped with fire foam. FBC R302.11(4) Will need to be approved prior to drywall nailing inspection. |
Review History
| Department | Status | Date In | Date Out |
| BADMIN | COMPLETE | 04/14/2026 | 04/14/2026 |
| Note: Released By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM | |||
| BADMIN | HOLD | 04/09/2026 | 04/09/2026 |
| Note: Held By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM Lien law missing job value greater than $5000.00 | |||
| PLUM | COMPLETE | 04/08/2026 | 04/09/2026 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 05/21/2026 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 04/16/2026 |
| INSPECTION - PLUMBING | ¤60.00 | 04/16/2026 |
| PLAN REVIEW - MISC 32.50 | ¤32.50 | 04/16/2026 |
| SURCHARGE FS 533.721 | ¤2.00 | 04/16/2026 |
| SURCHARGE - FS 468.631 | ¤2.00 | 04/16/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | |
| Fees | Total Due: ¤40.00 | Total Paid: ¤166.50 |