I want to search for...
Permit #2026040722
Permit Details
Status: INSPECT
| Parcel Id: 07-11-31-7024-00540-0090 |
| Block: 00540 |
| Subdivision: 7024 - |
| Job Phone: 386-264-0550 |
| Location Address: 71 PROVIDENCE LN |
| Type: ME - MECHANICAL |
| Issue Date: 04/22/2026 |
| NOC: Unknown |
| Applicant name: GARY LLOYD SHEFFIELD |
| Owner: NATANSON LILIA |
|
Address P O BOX 040453 BROOKLYN, NY 11204 |
| Lot: 0090 |
| Contracted Stated Job Value: ¤5,200.00 |
| Job Description: replace hvac like for like unit A |
| Type: CN |
Contractor
DEPENDABLE COMFORT LLC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
PO BOX 912 PALM COAST, FL 32164 |
CAC1820539 (Exp: 08/31/2026) | 386-264-0550 |
Inspection History
| Type | Request Date | Result | Inspector |
| HVAC FINAL | 05/05/2026 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 5/5/2026 12:46:17 PM *** 5/5/26: A Virtual inspection will be available IF requested at the time of scheduling the re-inspection. If requesting a Virtual Re-inspection, please schedule the re-inspection for the same day that the deficiencies will be corrected and a FaceTime or Google Meet live virtual inspection can be completed. (Pictures are not approved). REQUESTED VIRTUAL INSPECTIONS MUST BE COMPLETED BY 3PM IN ORDER TO BE UPDATED IN THE SYSTEM. 1). Breaker for AHU does not match unit requirements. ( Min. - 32.3amp / Max. - 35amp --- 30amp installed). (breaker size indicated on label and 30 amp written on unit are marked incorrectly. Amperage for 208 volt is circled but unit is 240volts.) | |||
| HVAC FINAL | |||
| Note: 5/5/2026 - PREVIOUS INSPECTION NOTES 5/5/26: A Virtual inspection will be available IF requested at the time of scheduling the re-inspection. If requesting a Virtual Re-inspection, please schedule the re-inspection for the same day that the deficiencies will be corrected and a FaceTime or Google Meet live virtual inspection can be completed. (Pictures are not approved). REQUESTED VIRTUAL INSPECTIONS MUST BE COMPLETED BY 3PM IN ORDER TO BE UPDATED IN THE SYSTEM. 1). Breaker for AHU does not match unit requirements. ( Min. - 32.3amp / Max. - 35amp --- 30amp installed). (breaker size indicated on label and 30 amp written on unit are marked incorrectly. Amperage for 208 volt is circled but unit is 240volts.) |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 04/22/2026 |
| INSPECTION - MECHANICAL | ¤60.00 | 04/22/2026 |
| SURCHARGE FS 533.721 | ¤2.00 | 04/22/2026 |
| SURCHARGE - FS 468.631 | ¤2.00 | 04/22/2026 |
| REINSPECTION RESIDENTIAL | ¤40.00 | |
| Fees | Total Due: ¤40.00 | Total Paid: ¤94.00 |