I want to search for...

Permit #2026040722

Permit Details

Status: INSPECT

Parcel Id: 07-11-31-7024-00540-0090
Block: 00540
Subdivision: 7024 -
Job Phone: 386-264-0550
Location Address: 71 PROVIDENCE LN
Type: ME - MECHANICAL
Issue Date: 04/22/2026
NOC: Unknown
Applicant name: GARY LLOYD SHEFFIELD
Owner: NATANSON LILIA

Address

P O BOX 040453

BROOKLYN, NY 11204

Lot: 0090
Contracted Stated Job Value: ¤5,200.00
Job Description: replace hvac like for like unit A
Type: CN

Contractor

DEPENDABLE COMFORT LLC
Status Location Address State License Number Phone
ACTIVE

PO BOX 912

PALM COAST, FL 32164

CAC1820539 (Exp: 08/31/2026) 386-264-0550

Inspection History

Type Request Date Result Inspector
HVAC FINAL 05/05/2026 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 5/5/2026 12:46:17 PM *** 5/5/26: A Virtual inspection will be available IF requested at the time of scheduling the re-inspection. If requesting a Virtual Re-inspection, please schedule the re-inspection for the same day that the deficiencies will be corrected and a FaceTime or Google Meet live virtual inspection can be completed. (Pictures are not approved). REQUESTED VIRTUAL INSPECTIONS MUST BE COMPLETED BY 3PM IN ORDER TO BE UPDATED IN THE SYSTEM. 1). Breaker for AHU does not match unit requirements. ( Min. - 32.3amp / Max. - 35amp --- 30amp installed). (breaker size indicated on label and 30 amp written on unit are marked incorrectly. Amperage for 208 volt is circled but unit is 240volts.)
HVAC FINAL
Note: 5/5/2026 - PREVIOUS INSPECTION NOTES 5/5/26: A Virtual inspection will be available IF requested at the time of scheduling the re-inspection. If requesting a Virtual Re-inspection, please schedule the re-inspection for the same day that the deficiencies will be corrected and a FaceTime or Google Meet live virtual inspection can be completed. (Pictures are not approved). REQUESTED VIRTUAL INSPECTIONS MUST BE COMPLETED BY 3PM IN ORDER TO BE UPDATED IN THE SYSTEM. 1). Breaker for AHU does not match unit requirements. ( Min. - 32.3amp / Max. - 35amp --- 30amp installed). (breaker size indicated on label and 30 amp written on unit are marked incorrectly. Amperage for 208 volt is circled but unit is 240volts.)

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADMINISTRATIVE RESIDENTIAL ¤30.00 04/22/2026
INSPECTION - MECHANICAL ¤60.00 04/22/2026
SURCHARGE FS 533.721 ¤2.00 04/22/2026
SURCHARGE - FS 468.631 ¤2.00 04/22/2026
REINSPECTION RESIDENTIAL ¤40.00
Fees Total Due: ¤40.00 Total Paid: ¤94.00