I want to search for...
Permit #2026040924
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-3740-00000-0160 |
| Block: 00000 |
| Subdivision: 1241 - LAKE VIEW |
| Job Phone: 386-627-1357 |
| Location Address: 16 LAKESIDE PL E |
| Type: DR - DRIVEWAY |
| Issue Date: 04/29/2026 |
| NOC: RECORDED |
| Applicant name: MITCHELL REED |
| Owner: DELEVANTE DANIEL A & MAUREEN P H&W LIFE ESTATE |
|
Address 16 LAKESIDE PLACE EAST PALM COAST, FL 32137 |
| Lot: 0160 |
| Contracted Stated Job Value: ¤9,000.00 |
| Job Description: PAVER DRIVEWAY WITH CONCRETE APRON |
| Type: CN |
Contractor
ROYAL PAVING LLC
| Status | Location Address | Phone |
| ACTIVE |
4 LEWISTON COURT PALM COAST, FL 32137 |
386-237-7516 |
Inspection History
| Type | Request Date | Result | Inspector |
| ROW - FINAL APRON (AFTER POUR) | 05/07/2026 | APPROVED | EMADISON |
| Note: ** AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW - FINAL INSPECTION | 05/07/2026 | APPROVED | EMADISON |
| Note: ** AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| U -UTILITY RESIDENTIAL FINAL | 05/07/2026 | APPROVED | BVEIGA |
| ROW- PRE-APRON (PRE-POUR) | 05/05/2026 | APPROVED | TPOLACEK |
| Note: READY FOR PAVERS AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED 5/4/2026 - PREVIOUS INSPECTION NOTES 05-04-26 TPOLACEK** LEFT SIDE APRON WING NEEDS OT BE 36" FROM EDGE OF DRIVEWAY OUT. PLEASE MAKE CORRECTIONS BEFORE POURING. AT THE TIME OF THIS INSPECTION YOU ARE PARTIALLY APPROVED TO POUR YOUR DRIVEWAY APRON, SIDEWALK AND PAVER RESTRAINTS. **** DO NOT LAY ANY PAVERS UNTIL AFTER A SECONDARY SPREAD AND COMPACTION INSPECTION HAS BEEN SCHEDULED AND PASSED**** BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS 5/1/2026 - PREVIOUS INSPECTION NOTES Talked to CM and requested to cancel. | |||
| ROW- PRE-APRON (PRE-POUR) | 05/04/2026 | PARTIALLY APPROVED | TPOLACEK |
| Note: 05-04-26 TPOLACEK** LEFT SIDE APRON WING NEEDS OT BE 36" FROM EDGE OF DRIVEWAY OUT. PLEASE MAKE CORRECTIONS BEFORE POURING. AT THE TIME OF THIS INSPECTION YOU ARE PARTIALLY APPROVED TO POUR YOUR DRIVEWAY APRON, SIDEWALK AND PAVER RESTRAINTS. **** DO NOT LAY ANY PAVERS UNTIL AFTER A SECONDARY SPREAD AND COMPACTION INSPECTION HAS BEEN SCHEDULED AND PASSED**** BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS 5/1/2026 - PREVIOUS INSPECTION NOTES Talked to CM and requested to cancel. | |||
| ROW- PAVER RESTRAINTS | 05/04/2026 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THIS INSPECTION YOU ARE PARTIALLY APPROVED TO POUR YOUR DRIVEWAY APRON, SIDEWALK AND PAVER RESTRAINTS. **** DO NOT LAY ANY PAVERS UNTIL AFTER A SECONDARY SPREAD AND COMPACTION INSPECTION HAS BEEN SCHEDULED AND PASSED**** BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS 5/1/2026 - PREVIOUS INSPECTION NOTES Talked to CM and requested to cancel. | |||
| ROW- PRE-APRON (PRE-POUR) | 05/01/2026 | CANCELLED BY APPLICANT | RRICKS |
| Note: Talked to CM and requested to cancel. | |||
| ROW- PAVER RESTRAINTS | 05/01/2026 | CANCELLED BY APPLICANT | RRICKS |
| Note: Talked to CM and requested to cancel. |
Review History
| Department | Status | Date In | Date Out |
| ZON | HOLD | 04/28/2026 | 04/28/2026 |
| Note: Held By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM site plan needs to show width of the new paver drive | |||
| ZON | COMPLETE | 04/28/2026 | 04/28/2026 |
| Note: Released By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 04/28/2026 | 04/29/2026 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| RSI | COMPLETE | 04/28/2026 | 04/29/2026 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 04/22/2026 | 04/23/2026 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| RSI | COMPLETE | 04/22/2026 | 04/22/2026 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| UTL | COMPLETE | 04/22/2026 | 04/29/2026 |
| Note: Released By: LARRY FITZGERALD - (386)286-2041 - LFITZGERALD@PALMCOASTGOV.COM | |||
| ZON | HOLD | 04/22/2026 | 04/27/2026 |
| Note: Held By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM site plan needs to show width of the new paver driveway please bring in the original paver agreement |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 04/29/2026 |
| RECORDING FEE REIMBURSE DOC | ¤52.50 | 04/29/2026 |
| RSI DRIVEWAY AFTER POUR | ¤16.25 | 04/29/2026 |
| RSE DRIVE PRE POUR INSPECTION | ¤32.50 | 04/29/2026 |
| RSI ROW FINAL INSPECTION | ¤16.25 | 04/29/2026 |
| RSI SITE PLAN REVIEW | ¤16.25 | 04/29/2026 |
| SITE PLAN 15 | ¤15.00 | 04/29/2026 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤178.75 |