I want to search for...

Permit #2026040959

Permit Details

Status: INSPECT

Parcel Id: 48-11-31-1710-00000-0820
Block: 00000
Subdivision: 2087 - ESTATES AT GRAND HAVEN PHASE II
Job Phone: 386-503-6922
Location Address: 215 WILLOW OAK WAY
Type: PO - POOL
Issue Date: 05/19/2026
NOC: RECORDED
Applicant name: JOSE E ORTIZ JR
Owner: MARINO THOMAS & GINA

Address

215 WILLOW OAK WAY

PALM COAST, FL 32137

Lot: 0820
Contracted Stated Job Value: ¤75,000.00
Job Description: Pool
Type: CN

Contractor

JOSE E ORTIZ JR LLC
Status Location Address State License Number Phone
ACTIVE

4601 E MOODY BLVD A3

PALM COAST, FL 32164

CPC1460694 (Exp: 08/31/2026) 386-313-6055

Sub Contractors

CHRISTOPHER I HALL
Status Location Address State License Number Phone Fax
ACTIVE

P. O. Box 2413

Bunnell, FL 32110

EC13002161 (Exp: 08/31/2028) (386) 437-2966 386-437-5042
RICHARD SWAN TOWNSEND II
Status Location Address State License Number Phone
ACTIVE

3111 OPPORTUNITY CT SUITE D

PORT ORANGE, FL 32129

CGC1515792 (Exp: 08/31/2026) 386-756-8770

Inspection History

Type Request Date Result Inspector
STEEL AND GROUND 05/26/2026 APPROVED MCONTRYMAN
STEEL AND GROUND 05/22/2026 CANCELLED BY APPLICANT WEB
POOL DECK
ELECTRIC AND ALARM
POOL FINAL
ROW- FINAL SURVEY/GRADING CERTIFICATION
ROW FIELD SURVEY /GRADING CERTIFICATION
ROW - FINAL INSPECTION
U -UTILITY RESIDENTIAL FINAL

Review History

Department Status Date In Date Out
ZON COMPLETE 05/11/2026 05/12/2026
Note: Released By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM
RSI COMPLETE 05/11/2026 05/14/2026
Note: Released By: TOM POLACEK - (386)346-8986 -
RSI HOLD 05/07/2026 05/11/2026
Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM need a new site plan with right address
ZON HOLD 05/07/2026 05/08/2026
Note: Held By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM site plan submitted is for a different address
BFLOOD COMPLETE 05/07/2026 05/08/2026
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BFLOOD HOLD 04/28/2026 04/28/2026
Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM PREVIOUS REVIEW COMPLETED IN ERROR. THIS IS CORRECT REVIEW. ALL COMMENTS BELOW PER THE 2023 FLORIDA BUILDING CODE-RESIDENTIAL Provide pool deck elevation for proposed pool. Structural systems supporting proposed pool to be designed, connected and anchored to resist flotation, collapse or permanent lateral movement due to structural loads and stresses from flooding equal to the design flood elevation.  Provide engineering statement on engineered pool plans confirming design conforms to this section. For previously approved Pool Master Plans, provide engineer's statement signed and sealed by the engineer on separate letterhead referencing this site address and permit number.  R322.1.2. Pool equipment located in floodplain is permitted to be installed below the design flood elevation provided it is elevated to the extent practical and is anchored to prevent flotation and resist flood forces and is supplied by electrical  branch circuits that have ground-fault circuit interrupter protection.  Electrical wiring systems are permitted below the design flood elevation provided they conform to the provisions of the Electrical Code for wet locations.  Add notes to pool plans indicating a.) pool equipment will be installed at the highest elevation possible; b.) that all pool equipment will be anchored in a manner to prevent flotation and to resist flood forces; c.) that pool electrical equipment will be provided with branch circuits that are ground-fault circuit interrupter protected and d.) that all electrical equipment to be installed as required for wet locations per the 2020 NEC.  R322.1.6 Exception. 
BFLOOD COMPLETE 04/22/2026 04/27/2026
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM ALL COMMENTS BELOW PER THE 2023 FLORIDA BUILDING CODE-RESIDENTIAL Provide pool deck elevation for proposed pool. Structural systems supporting proposed pool to be designed, connected and anchored to resist flotation, collapse or permanent lateral movement due to structural loads and stresses from flooding equal to the design flood elevation.  Provide engineering statement on engineered pool plans confirming design conforms to this section. For previously approved Pool Master Plans, provide engineer's statement signed and sealed by the engineer on separate letterhead referencing this site address and permit number.  R322.1.2. Pool equipment located in floodplain is permitted to be installed below the design flood elevation provided it is elevated to the extent practical and is anchored to prevent flotation and resist flood forces and is supplied by electrical  branch circuits that have ground-fault circuit interrupter protection.  Electrical wiring systems are permitted below the design flood elevation provided they conform to the provisions of the Electrical Code for wet locations.  Add notes to pool plans indicating a.) pool equipment will be installed at the highest elevation possible; b.) that all pool equipment will be anchored in a manner to prevent flotation and to resist flood forces; c.) that pool electrical equipment will be provided with branch circuits that are ground-fault circuit interrupter protected and d.) that all electrical equipment to be installed as required for wet locations per the 2020 NEC.  R322.1.6 Exception. 
BLD COMPLETE 04/22/2026 04/27/2026
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
ELEC COMPLETE 04/22/2026 04/27/2026
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH COMPLETE 04/22/2026 04/23/2026
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
RSI HOLD 04/22/2026 04/27/2026
Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM Must have proposed or flow arrows to show how drainage will flow after the pool is completed.
ZON HOLD 04/22/2026 04/27/2026
Note: Held By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM Site plan measurements and screen enclosure and pool plan measurements do not match

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADMINISTRATIVE RESIDENTIAL ¤30.00 05/19/2026
INSPECTION- POOL ¤160.00 05/19/2026
PLAN REVIEW - RESIDENTIAL ¤65.00 05/19/2026
RSI FIELD SURVEY INSPECTION ¤48.75 05/19/2026
RSI PLAN REVIEW NEW ¤48.75 05/19/2026
RSI FNL SURVEY/GRADING CERT ¤48.75 05/19/2026
RSI ROW FINAL INSPECTION ¤16.25 05/19/2026
SURCHARGE FS 533.721 ¤2.55 05/19/2026
SURCHARGE - FS 468.631 ¤3.83 05/19/2026
SITE PLAN 30 ¤30.00 05/19/2026
Fees Total Due: ¤0.00 Total Paid: ¤453.88