I want to search for...
Permit #2026041177
Permit Details
Status: INSPECT
| Parcel Id: 04-11-30-5571-00000-1940 |
| CONDITIONED SPACE: 2766 sqft |
| GARAGE: 708 sqft |
| OPENED PORCH (WITH ROOF) : 107 sqft |
| OPENED PORCH (WITH ROOF) : 240 sqft |
| Total Square Footage: 3821 sqft |
| Subdivision: 2366 - SOMERSET SUBDIVISION PH 2 |
| Job Phone: 904-596-6645 |
| Location Address: 69 GOLDEN BELL AVE |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 05/21/2026 |
| NOC: RECORDED |
| Applicant name: MICHAEL T HOLDER |
| Owner: KB HOME JACKSONVILLE LLC |
|
Address 10475 FORTUNE PARKWAY JACKSONVILLE, FL 32256 |
|
Address SUITE 100 JACKSONVILLE, FL 32256 |
| Lot: 194 |
| Contracted Stated Job Value: ¤140,000.00 |
| Job Description: NEW SINGLE FAMILY DWELLING |
| Type: CN |
Contractor
KB HOME JACKSONVILLE, LLC
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
10475 FORTUNE PKWY JACKSONVILLE, FL 32256 |
SUITE 100 JACKSONVILLE, FL 32256 |
CGC1509034 (Exp: 08/31/2026) | 904-596-6645 |
Sub Contractors
LARRY WILLIAMS
| Status | Location Address | State License Number | Phone |
| ACTIVE |
1750 EMERSON ST JACKSONVILLE, FL 32207 |
LI45034 (Exp: 08/31/2026) | 904-721-5431 |
COREY MICHAEL TENNANT
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3370 AGRICULTURAL CNETER DR ST AUGUSTINE, FL 32092 |
CAC1819063 (Exp: 08/31/2026) | 904-829-8898 |
BENJAMIN MICHAEL RAY
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| ACTIVE |
6310 MABLETON PKWY JACKSONVILLE, FL 32216 |
SUITE 1000 MABLETON, GA 30126 |
CFC1428415 (Exp: 08/31/2026) | 904-861-5421 | 904-861-5426 |
JAMES E LINTON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
200 COLLEGE DR ORANGE PARK, FL 32065 |
EC0001152 (Exp: 08/31/2026) | 904-272-0272 |
BOBBY WAYNE CAMPBELL
| Status | Location Address | State License Number | Phone |
| ACTIVE |
117 GUTHRIE ROAD GREEN COVE SPRINGS, FL 32043 |
CCC1326752 (Exp: 08/31/2026) | 904-200-1600 |
Inspection History
| Type | Request Date | Result | Inspector |
| GRAVITY SEWER TEST | 06/09/2026 | APPROVED - AS NOTED | MCONTRYMAN |
| Note: 6/9/26 Via Virtual -Water service line hooked into meter at time of inspection | |||
| SEWER TIE IN | 06/09/2026 | APPROVED - AS NOTED | MCONTRYMAN |
| Note: 6/9/26 Via Virtual -Water service line hooked into meter at time of inspection Inspector Notes from Inspection 2075 6/9/26 Via Virtual -Water service line hooked into meter at time of inspection | |||
| MONOLITHIC SLAB | 06/04/2026 | APPROVED | JSTEWART |
| Note: 6/3/2026 - PREVIOUS INSPECTION NOTES Please relocate multiple water supply lines that run parrelell in the interior wall footing. FBC P2604.4 … | |||
| MONOLITHIC SLAB | 06/03/2026 | Disapproved - NO FEE | JSTEWART |
| Note: Please relocate multiple water supply lines that run parrelell in the interior wall footing. FBC P2604.4 … | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 06/01/2026 | APPROVED | JSTEWART |
| Note: 5/29/2026 - PREVIOUS INSPECTION NOTES 5/28/2026 - PREVIOUS INSPECTION NOTES 1. Sewer line at 5ft head needs to be sloped for drainage. TABLE P3005.4.2 2. Powder room toilet Line needs to be sloped . TABLE P3005.4.2 appears they have settled, need a firm bed to maintain slope. FBC P2604.1 | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 05/29/2026 | CANCELLED BY APPLICANT | JSTEWART |
| Note: 5/28/2026 - PREVIOUS INSPECTION NOTES 1. Sewer line at 5ft head needs to be sloped for drainage. TABLE P3005.4.2 2. Powder room toilet Line needs to be sloped . TABLE P3005.4.2 appears they have settled, need a firm bed to maintain slope. FBC P2604.1 | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 05/28/2026 | Disapproved - NO FEE | JSTEWART |
| Note: 1. Sewer line at 5ft head needs to be sloped for drainage. TABLE P3005.4.2 2. Powder room toilet Line needs to be sloped . TABLE P3005.4.2 appears they have settled, need a firm bed to maintain slope. FBC P2604.1 | |||
| WATER METER INSTALLATION REQUEST | 05/28/2026 | APPROVED | ISANDERSON |
| FORMBOARD SURVEY (OFFICE USE ONLY) | 05/27/2026 | APPROVED | RRICKS |
| PEP TANK INSTALLATION REQUEST | |||
| U-CROSS CONNECTION | |||
| ROW- PRE-APRON (PRE-POUR) | |||
| ROW - FINAL APRON (AFTER POUR) | |||
| ROW - FINAL INSPECTION | |||
| U -UTILITY RESIDENTIAL FINAL | |||
| LATH/BRICK/ WATER BARRIER | |||
| ALL ROUGH | |||
| WALL SHEATHING | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | |||
| ROOF VALLEY & METAL | |||
| INSULATION | |||
| DRYWALL NAILING | |||
| BLD - BUILDING FINAL | |||
| ELECTRIC - EARLY POWER |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 05/27/2026 | 05/27/2026 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 05/27/2026 | 05/27/2026 |
| Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 05/15/2026 | 05/15/2026 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 05/12/2026 | 05/13/2026 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 05/12/2026 | 05/13/2026 |
| Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM | |||
| BLD | HOLD | 05/12/2026 | 05/15/2026 |
| Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM 1. ok 2. Provide handrail detail per R311.7.8 through R311.7.8.3 and R311.7.8.5. Provide stair live and dead loads per R301.4, R301.5 and Table R301.5. Provide tread material specs and concentrated load for treads per Table R301.5 Note c. Provide stair string material specs and number of required stringers to achieve minimum design loads. Provide stair landing construction and floor sheathing details. Provide stair, stair landing attachment details necessary to achieve minimum design loads. | |||
| URB | COMPLETE | 05/12/2026 | 05/19/2026 |
| Note: Released By: JOHN BEAUDET - (386)986-2456 - JBEAUDET@PALMCOASTGOV.COM | |||
| BLD | HOLD | 04/28/2026 | 05/04/2026 |
| Note: Held By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM 1. Provide floor layouts. 2. Provide full stair section view from bottom of stairs through ceiling above second floor. Provide headroom per R311.7.2. Provide total vertical rise above and below mid-point landing R311.7.2. Provide riser height R311.7.5.1. Provide tread depth R311.7.5.2. Provide nosing detail R311.7.5. Provide landing dimensions including mid-point landing R311.7.6. Provide handrail detail per R311.7.8 through R311.7.8.3 and R311.7.8.5. Provide stair live and dead loads per R301.4, R301.5 and Table R301.5. Provide tread material specs and concentrated load for treads per Table R301.5 Note c. Provide stair string material specs and number of required stringers to achieve minimum design loads. Provide stair landing construction and floor sheathing details. Provide stair, stair landing attachment details necessary to achieve minimum design loads. | |||
| CUSVC | COMPLETE | 04/28/2026 | 05/01/2026 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 04/28/2026 | 05/04/2026 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 04/28/2026 | 04/29/2026 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| GAS | COMPLETE | 04/28/2026 | 04/29/2026 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 04/28/2026 | 04/29/2026 |
| Note: Released By: IVAN SANDERSON - - | |||
| MECH | HOLD | 04/28/2026 | 04/29/2026 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide all missing plan pages AD-5, A1-A4 | |||
| SW1 | COMPLETE | 04/28/2026 | 05/05/2026 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ZON | HOLD | 04/28/2026 | 05/01/2026 |
| Note: Held By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM Missing elevation plan Missing Floor plan Landscape plan missing the required trees per square foot (3) Cannot complete Zoning review of a/c location | |||
| URB | HOLD | 04/28/2026 | 05/06/2026 |
| Note: Held By: JOHN BEAUDET - (386)986-2456 - JBEAUDET@PALMCOASTGOV.COM Need one tree 3 are required. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| WATER-METER | ¤874.47 | 05/21/2026 |
| WATER- TURN ON | ¤50.00 | 05/21/2026 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 05/21/2026 |
| INSPECTION - RESIDENTIAL | ¤1,501.50 | 05/21/2026 |
| PLAN REVIEW - RESIDENTIAL | ¤425.88 | 05/21/2026 |
| FC IMPACT FEE EMS | ¤62.00 | 05/21/2026 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 05/21/2026 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 05/21/2026 |
| FIRE RES IMPACT FEE 10-25 | ¤942.00 | 05/21/2026 |
| WATER METER W/OUT TAP | ¤965.03 | 05/21/2026 |
| PARKS IMPACT FEE 10-25 | ¤3,164.00 | 05/21/2026 |
| RECLAIM WATER PERMIT INSPECTIO | ¤40.00 | 05/21/2026 |
| RSI DRIVEWAY AFTER POUR | ¤16.25 | 05/21/2026 |
| RSE DRIVE PRE POUR INSPECTION | ¤32.50 | 05/21/2026 |
| RSI FORMBOARD REVIEW | ¤16.25 | 05/21/2026 |
| RSI PLAN REVIEW NEW | ¤48.75 | 05/21/2026 |
| RSI FNL SURVEY/GRADING CERT | ¤48.75 | 05/21/2026 |
| RSI ROW FINAL INSPECTION | ¤16.25 | 05/21/2026 |
| SCHOOL BOARD IMPACT FEE RES | ¤5,450.00 | 05/21/2026 |
| SURCHARGE FS 533.721 | ¤19.57 | 05/21/2026 |
| SURCHARGE - FS 468.631 | ¤29.36 | 05/21/2026 |
| TRANSP RES IMPACT FEE 10-25 | ¤10,427.82 | 05/21/2026 |
| WASTEWATER PERM INSPECTION | ¤80.00 | 05/21/2026 |
| WASTEWATER PERM REVIEW | ¤25.00 | 05/21/2026 |
| SEWER CAPITAL FACILITY | ¤3,628.86 | 05/21/2026 |
| WATER CAPITAL FACILITY FEE | ¤3,091.14 | 05/21/2026 |
| WATER PERMIT REVIEW | ¤25.00 | 05/21/2026 |
| SITE PLAN 30 | ¤30.00 | 05/21/2026 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤31,526.38 |