Permit Details

Status: INSPECT

Parcel Id: 07-11-31-7063-00760-0070
Block: 00760
Subdivision: 2174 - SECTION 63-ZEBULAHS TRAIL
Job Phone: 386-439-3191
Location Address: 7 ZEBULON PL
Type: WH - WATER HEATER
Issue Date: 04/28/2026
NOC: Unknown
Applicant name: TERRY M MCNITT
Owner: WISE BENJAMIN P & DEVRIE K PARADOWSKI H&W

Address

7 ZEBULON PLACE

PALM COAST, FL 32164

Lot: 0070
Contracted Stated Job Value: ¤1,550.00
Job Description: WATER HEATER
Type: CN

Contractor

TERRYS PLUMBING INC
Status Location Address State License Number Phone
ACTIVE

909 MAGNOLIA TERRACE

FLAGLER BEACH, FL 32136

CFC1426001 (Exp: 08/31/2026) 386-439-3191

Inspection History

Type Request Date Result Inspector
PLUMBING FINAL 06/01/2026 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 6/1/2026 3:43:10 PM *** 6/1/26: 1). The pressure relief valve (in lieu of expansion tank) outlet is 3/4". Pipe cannot be reduced or trapped and must flow by gravity per FBC-P2804.6.1 (items 3, 8 and 9). As previously noted. Please assure that you are in compliance with all 14 items listed under the code to avoid faile inspections. 5/11/2026 - PREVIOUS INSPECTION NOTES PLease fix items before next inspection P2804.6.1-Requirements for discharge pipe. The discharge piping serving a pressure-relief valve, temperaturerelief valve or combination valve shall. ( see Item 3 , 4 ,10 and 12 1. Not be directly connected to the drainage system. 2. Discharge through an air gap located in the same room as the water heater. 3. Not be smaller than the diameter of the outlet of the valve served and shall discharge full size to the air gap. 4. Serve a single relief device and shall not connect to piping serving any other relief device or equipment. 5/4/2026 - PREVIOUS INSPECTION NOTES 5/4/26: Nobody home for inspection. No call to cancel. Spoke to resident through video camera. 1). Need access for inspection. FBC[A] 110.5. A two hour estimated arrival window can be provided by contacting the assigned Inspector in the morning starting at 8am.
PLUMBING FINAL 05/11/2026 Disapproved -FEE REQUIRED CVANSTRAHLEN
Note: PLease fix items before next inspection P2804.6.1-Requirements for discharge pipe. The discharge piping serving a pressure-relief valve, temperaturerelief valve or combination valve shall. ( see Item 3 , 4 ,10 and 12 1. Not be directly connected to the drainage system. 2. Discharge through an air gap located in the same room as the water heater. 3. Not be smaller than the diameter of the outlet of the valve served and shall discharge full size to the air gap. 4. Serve a single relief device and shall not connect to piping serving any other relief device or equipment. 5/4/2026 - PREVIOUS INSPECTION NOTES 5/4/26: Nobody home for inspection. No call to cancel. Spoke to resident through video camera. 1). Need access for inspection. FBC[A] 110.5. A two hour estimated arrival window can be provided by contacting the assigned Inspector in the morning starting at 8am.
PLUMBING FINAL 05/04/2026 Disapproved -FEE REQUIRED RSIMS
Note: *** NOTES ADDED BY RSIMS 5/4/2026 2:43:22 PM *** 5/4/26: Nobody home for inspection. No call to cancel. Spoke to resident through video camera. 1). Need access for inspection. FBC[A] 110.5. A two hour estimated arrival window can be provided by contacting the assigned Inspector in the morning starting at 8am.
PLUMBING FINAL
Note: 6/1/2026 - PREVIOUS INSPECTION NOTES 6/1/26: 1). The pressure relief valve (in lieu of expansion tank) outlet is 3/4". Pipe cannot be reduced or trapped and must flow by gravity per FBC-P2804.6.1 (items 3, 8 and 9). As previously noted. Please assure that you are in compliance with all 14 items listed under the code to avoid faile inspections. 5/11/2026 - PREVIOUS INSPECTION NOTES PLease fix items before next inspection P2804.6.1-Requirements for discharge pipe. The discharge piping serving a pressure-relief valve, temperaturerelief valve or combination valve shall. ( see Item 3 , 4 ,10 and 12 1. Not be directly connected to the drainage system. 2. Discharge through an air gap located in the same room as the water heater. 3. Not be smaller than the diameter of the outlet of the valve served and shall discharge full size to the air gap. 4. Serve a single relief device and shall not connect to piping serving any other relief device or equipment. 5/4/2026 - PREVIOUS INSPECTION NOTES 5/4/26: Nobody home for inspection. No call to cancel. Spoke to resident through video camera. 1). Need access for inspection. FBC[A] 110.5. A two hour estimated arrival window can be provided by contacting the assigned Inspector in the morning starting at 8am.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 05/28/2026
REINSPECTION RESIDENTIAL ¤40.00 05/04/2026
SURCHARGE FS 533.721 ¤2.00 04/28/2026
SURCHARGE - FS 468.631 ¤2.00 04/28/2026
ADMINISTRATIVE RESIDENTIAL ¤30.00 04/28/2026
INSPECTION - RESIDENTIAL ¤60.00 04/28/2026
REINSPECTION RESIDENTIAL ¤40.00
Fees Total Due: ¤40.00 Total Paid: ¤174.00