I want to search for...
Permit #2026050105
Permit Details
Status: FINAL
| Parcel Id: 15-11-31-5920-00080-0130 |
| Block: 00080 |
| Subdivision: 5920 - |
| Job Phone: 386-313-6020 |
| Location Address: 25 PELICAN CT |
| Type: ME - MECHANICAL |
| Issue Date: 05/11/2026 |
| NOC: Unknown |
| Applicant name: JAMES CRAIG FISHER |
| Owner: LEVESQUE PAUL HERVEY & CLAIRE A LEVESQUE TRUSTEES |
|
Address 25 PELICAN COURT PALM COAST, FL 32137 |
| Lot: 0130 |
| Contracted Stated Job Value: ¤9,829.00 |
| Job Description: replace hvac like for like |
| Type: CN |
Contractor
FISHERS HEAT & AIR INC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
PO BOX 451 BUNNELL, FL 32110 |
CAC1819807 (Exp: 08/31/2026) | 386-222-9549 |
Inspection History
| Type | Request Date | Result | Inspector |
| HVAC FINAL | 05/21/2026 | FINAL APPROVED | MCONTRYMAN |
| Note: Via Virtual 5/14/2026 - PREVIOUS INSPECTION NOTES 5/14/26 1. ODU has minimum amperage as 29.5amp and max of 30amp. Breaker installed is 25amp NEC 440.4 2. Heat strips are not labeled on AH FBCR M1303.1 --Please verify on equipment which one the breakers belong to since there are 2 | |||
| HVAC FINAL | 05/14/2026 | Disapproved - NO FEE | MCONTRYMAN |
| Note: 5/14/26 1. ODU has minimum amperage as 29.5amp and max of 30amp. Breaker installed is 25amp NEC 440.4 2. Heat strips are not labeled on AH FBCR M1303.1 --Please verify on equipment which one the breakers belong to since there are 2 |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 05/11/2026 |
| INSPECTION - MECHANICAL | ¤60.00 | 05/11/2026 |
| SURCHARGE FS 533.721 | ¤2.00 | 05/11/2026 |
| SURCHARGE - FS 468.631 | ¤2.00 | 05/11/2026 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤94.00 |