Permit #2026050194

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7030-00820-0040
Block: 00820
Subdivision: 7030 -
Job Phone: 347-534-8516
Location Address: 8 RAMSGATE PL
Type: WH - WATER HEATER
Issue Date: 05/06/2026
NOC: Unknown
Applicant name: THOMAS ROHR
Owner: DUROCHER STEVEN R & DONNA D DUROCHER H&W

Address

9 RAMSGATE PLACE

PALM COAST, FL 32164

Lot: 0040
Contracted Stated Job Value: ¤2,400.00
Job Description: Water heater
Type: CN

Contractor

A GRANDFATHERS LEGACY PLUMBING LLC
Status Location Address State License Number Phone
ACTIVE

121 OAKLEAF WAY

,

RF11067905 (Exp: 08/31/2027) 347-534-8516

Inspection History

Type Request Date Result Inspector
PLUMBING FINAL 05/12/2026 APPROVED CVANSTRAHLEN
Note: Virtual inspection was provided on 05/11 at 11:23 plumber fix items ( all good ) Need to reeschedule inspection for next available day 5/11/2026 - PREVIOUS INSPECTION NOTES Please fix items before next inspection P2804.6.1-Requirements for discharge pipe. The discharge piping serving a pressure-relief valve, temperaturerelief valve or combination valve shall. ( see Item 3 , 4 ,10 and 12 1. Not be directly connected to the drainage system. 2. Discharge through an air gap located in the same room as the water heater. 3. Not be smaller than the diameter of the outlet of the valve served and shall discharge full size to the air gap. 4. Serve a single relief device and shall not connect to piping serving any other relief device or equipment. 5. Discharge to the floor, to the pan serving the water heater or storage tank, to a waste receptor or to the outdoors. 6. Discharge in a manner that does not cause personal injury or structural damage. 7. Discharge to a termination point that is readily observable by the building occupants. 8. Not be trapped. 9. Be installed to flow by gravity. 10. Terminate not more than 6 inches (152 mm) and not less than two times the discharge pipe diameter above the floor or waste receptor flood level rim. 11. Not have a threaded connection at the end of the piping. 12. Not have valves or tee fittings. 13. Be constructed of those materials indicated in Section P2906.5 or materials tested, rated and approved for such use in accordance with ASME A112.4.1. 14. Be one nominal size larger than the size of the relief-valve outlet, where the relief-valve discharge piping is installed with insert fittings. The outlet end of such tubing shall be fastened in place. 5/7/2026 - PREVIOUS INSPECTION NOTES ACCESS FOR INSPECTION - SPECIAL INSTRUCTIONS -FBC[A] 110.5 Ring door bell , not anwser was giving
PLUMBING FINAL 05/11/2026 Disapproved -FEE REQUIRED CVANSTRAHLEN
Note: Please fix items before next inspection P2804.6.1-Requirements for discharge pipe. The discharge piping serving a pressure-relief valve, temperaturerelief valve or combination valve shall. ( see Item 3 , 4 ,10 and 12 1. Not be directly connected to the drainage system. 2. Discharge through an air gap located in the same room as the water heater. 3. Not be smaller than the diameter of the outlet of the valve served and shall discharge full size to the air gap. 4. Serve a single relief device and shall not connect to piping serving any other relief device or equipment. 5. Discharge to the floor, to the pan serving the water heater or storage tank, to a waste receptor or to the outdoors. 6. Discharge in a manner that does not cause personal injury or structural damage. 7. Discharge to a termination point that is readily observable by the building occupants. 8. Not be trapped. 9. Be installed to flow by gravity. 10. Terminate not more than 6 inches (152 mm) and not less than two times the discharge pipe diameter above the floor or waste receptor flood level rim. 11. Not have a threaded connection at the end of the piping. 12. Not have valves or tee fittings. 13. Be constructed of those materials indicated in Section P2906.5 or materials tested, rated and approved for such use in accordance with ASME A112.4.1. 14. Be one nominal size larger than the size of the relief-valve outlet, where the relief-valve discharge piping is installed with insert fittings. The outlet end of such tubing shall be fastened in place. 5/7/2026 - PREVIOUS INSPECTION NOTES ACCESS FOR INSPECTION - SPECIAL INSTRUCTIONS -FBC[A] 110.5 Ring door bell , not anwser was giving
PLUMBING FINAL 05/07/2026 Disapproved - NO FEE CVANSTRAHLEN
Note: ACCESS FOR INSPECTION - SPECIAL INSTRUCTIONS -FBC[A] 110.5 Ring door bell , not anwser was giving

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 05/11/2026
SURCHARGE FS 533.721 ¤2.00 05/06/2026
SURCHARGE - FS 468.631 ¤2.00 05/06/2026
ADMINISTRATIVE RESIDENTIAL ¤30.00 05/06/2026
INSPECTION - RESIDENTIAL ¤60.00 05/06/2026
Fees Total Due: ¤0.00 Total Paid: ¤134.00