I want to search for...

Permit #2026050262

Permit Details

Status: INSPECT

Parcel Id: 07-11-31-7031-00030-0240
Block: 00030
Subdivision: 2166 - SECTION 31-ROYAL PALMS
Job Phone: 386-279-0197
Location Address: 6 RIPPLEWOOD LN
Type: PO - POOL
Issue Date: 05/14/2026
NOC: RECORDED
Applicant name: BRYAN ANTHONY CROWE
Owner: HIPPE DANIEL C & SUSAN J H&W

Address

6 RIPPLEWOOD LANE

PALM COAST, FL 32164

Lot: 0240
Contracted Stated Job Value: ¤80,398.00
Job Description: SWIMMING POOL WITH SCREEN ENCLOSURE
Type: CN

Contractor

EXQUISITE POOL AND SPA
Status Location Address State License Number Phone
ACTIVE

1661 RICHLAND AVE

,

CPC1461059 (Exp: 08/31/2026) 386-279-0197

Sub Contractors

JEFFREY ADAM MCGREGOR
Status Location Address State License Number Phone Fax
ACTIVE

1312 YORKTOWN STREET

DELAND , FL 32724

EC13005662 (Exp: 08/31/2026) 386-736-7475 386-785-1503

Inspection History

Type Request Date Result Inspector
STEEL AND GROUND 06/03/2026 Disapproved -FEE REQUIRED CVANSTRAHLEN
Note: Please fix items before next inspection #1-No permit box , FBC [A] 105.7-NEEDS PERMIT ON SITE #3-FBC [A]107.3.1-NEEDS APPROVED PLANS ON SITE #3-corners on pool area cave in-FBC-R404.1.3.3.7.4-This provision mandates that when a concrete footing is poured, the steel reinforcement (rebar) must maintain a minimum clear distance of 3 between the rebar itself and the dirt (ground) below it. The concrete is required to completely surround and encapsulate the steel to protect it from soil moisture, preventing the rebar from rusting and keeping the foundation structurally
STEEL AND GROUND 06/03/2026 Approval - Private Provider PPROVIDER
Note: 6/3/2026 - PREVIOUS INSPECTION NOTES Please fix items before next inspection #1-No permit box , FBC [A] 105.7-NEEDS PERMIT ON SITE #3-FBC [A]107.3.1-NEEDS APPROVED PLANS ON SITE #3-corners on pool area cave in-FBC-R404.1.3.3.7.4-This provision mandates that when a concrete footing is poured, the steel reinforcement (rebar) must maintain a minimum clear distance of 3 between the rebar itself and the dirt (ground) below it. The concrete is required to completely surround and encapsulate the steel to protect it from soil moisture, preventing the rebar from rusting and keeping the foundation structurally
POOL DECK
ELECTRIC AND ALARM
POOL FINAL
ROW- FINAL SURVEY/GRADING CERTIFICATION
ROW FIELD SURVEY /GRADING CERTIFICATION
ROW - FINAL INSPECTION
U -UTILITY RESIDENTIAL FINAL

Review History

Department Status Date In Date Out
BFLOOD CANCEL 05/07/2026 05/08/2026
BLD COMPLETE 05/07/2026 05/12/2026
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
ELEC COMPLETE 05/07/2026 05/11/2026
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH COMPLETE 05/07/2026 05/08/2026
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
RSI COMPLETE 05/07/2026 05/12/2026
Note: Released By: FRANK SLADISH - (386)871-6113 - FSLADISH@PALMCOASTGOV.COM
ZON COMPLETE 05/07/2026 05/11/2026
Note: Released By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
INSPECTION- POOL ¤160.00 05/14/2026
PLAN REVIEW - RESIDENTIAL ¤65.00 05/14/2026
RSI FIELD SURVEY INSPECTION ¤48.75 05/14/2026
RSI PLAN REVIEW NEW ¤48.75 05/14/2026
RSI FNL SURVEY/GRADING CERT ¤48.75 05/14/2026
RSI ROW FINAL INSPECTION ¤16.25 05/14/2026
SURCHARGE FS 533.721 ¤2.55 05/14/2026
SURCHARGE - FS 468.631 ¤3.83 05/14/2026
SITE PLAN 30 ¤30.00 05/14/2026
ADMINISTRATIVE RESIDENTIAL ¤30.00 05/14/2026
ADMINISTRATIVE - RESID PP75 ¤75.00
Fees Total Due: ¤75.00 Total Paid: ¤453.88