I want to search for...
Permit #2026050347
Permit Details
Status: READY
| Parcel Id: 07-11-31-7033-00140-0190 |
| CONDITIONED SPACE: 2800 sqft |
| GARAGE: 1006 sqft |
| OPENED PORCH (WITH ROOF) : 136 sqft |
| ENCLOSE EXISTING PORCH TO LIVING : 290 sqft |
| Total Square Footage: 4232 sqft |
| Block: 00140 |
| Subdivision: 2184 - SECTION 33-ROYAL PALMS |
| Job Phone: 904-888-6443 |
| Location Address: 40 RED MILL DR |
| Type: DU - DUPLEX |
| NOC: NO DOCUMENTATION |
| Applicant name: AMIR BENTOV |
| Owner: WILD FERN GROUP LLC |
|
Address 324 WINDLEY DR ST AUGUSTINE, FL 32092 |
| Lot: 0190 |
| Contracted Stated Job Value: ¤380,000.00 |
| Job Description: DUPLEX |
| Type: CN |
Contractor
MAVEN HOMES LLC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
2800 N 6TH ST UNIT 790 , |
CRC1333741 (Exp: 08/31/2026) | 904-667-4330 |
Sub Contractors
GLEN WILLIAM KEHLE
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
P. O. Box 353511 BUNNELL, FL 32110 |
CFC057241 (Exp: 08/31/2026) | (386) 447-4249 | (386) 437-8488 |
JOSEPH H STRADA JR
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3400 ST JOHNS PKWY SANFORD, FL 32771 |
CAC043953 (Exp: 08/31/2026) | 877-906-1113 |
JOSEPH HORATIO STRADA JR
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3400 ST JOHNS PARKWAY SANFORD, FL 32771 |
EC13003715 (Exp: 08/31/2026) | 877-906-1113 |
Inspection History
| Type | Request Date | Result | Inspector |
| FORMBOARD SURVEY (OFFICE USE ONLY) | |||
| GEOTECHNICAL REPORT APPROVAL (OFFICE USE) | |||
| PLUMBING 1ST ROUGH UNDERGROUND | |||
| GRAVITY SEWER TEST | |||
| SEWER TIE IN | |||
| ELECTRIC - EARLY POWER | |||
| MONOLITHIC SLAB | |||
| LATH/BRICK/ WATER BARRIER | |||
| TIE BEAM / LINTEL | |||
| ALL ROUGH | |||
| FIREWALL FRAMING | |||
| FIREWALL DRYWALL NAILING | |||
| FIREWALL FINAL | |||
| WALL SHEATHING | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | |||
| ROOF VALLEY & METAL | |||
| INSULATION | |||
| DRYWALL NAILING | |||
| BLD - BUILDING FINAL | |||
| WATER METER INSTALLATION REQUEST | |||
| PEP TANK INSTALLATION REQUEST | |||
| U-CROSS CONNECTION | |||
| ROW- PRE-APRON (PRE-POUR) | |||
| ROW - FINAL APRON (AFTER POUR) | |||
| ROW - FINAL INSPECTION | |||
| U -UTILITY RESIDENTIAL FINAL |
Review History
| Department | Status | Date In | Date Out |
| ENGIN1 | HOLD | 06/11/2026 | 06/11/2026 |
| Note: Held By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM COPC Survey crew states that the benchmark nail in power pole is missing. | |||
| MECH | COMPLETE | 06/01/2026 | 06/05/2026 |
| Note: Released By: KENNETH SANDOE - - KSANDOE@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 05/26/2026 | 06/01/2026 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | HOLD | 05/26/2026 | 05/28/2026 |
| Note: Held By: KENNETH SANDOE - - KSANDOE@PALMCOASTGOV.COM Submit updated state card for right side. | |||
| SWALE | PENDING | 05/12/2026 | |
| BLD | COMPLETE | 05/11/2026 | 05/15/2026 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 05/11/2026 | 05/14/2026 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | HOLD | 05/11/2026 | 05/14/2026 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need correct outlet spacing in bed 2. NEC 2020 210.52 2. DW outlet can not be located behind the DW. NEC 2020 422.16 | |||
| ENGIN1 | COMPLETE | 05/11/2026 | 05/12/2026 |
| Note: Released By: LEVI SALYERDS - (386)986-2575 - LSALYERDS@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 05/11/2026 | 05/11/2026 |
| LOCATE | COMPLETE | 05/11/2026 | 05/11/2026 |
| Note: Released By: IVAN SANDERSON - - | |||
| MECH | HOLD | 05/11/2026 | 05/12/2026 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Direction house faces on Energy Calcs does not match the site plan. Revise to match per R405.4.2.1 FBC Energy Conservation 2023 8Th Edition 2. Design location on Energy calcs and Heatload need to be Daytona Beach 3. Plans show 3/4 in foam board on walls R5. Energy Calcs say R7. Revise When resubmitting, provide updated state cards | |||
| SW1 | COMPLETE | 05/11/2026 | 05/15/2026 |
| Note: Released By: RODNEY RICKS - (386)986-4726 - RRICKS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 05/11/2026 | 05/13/2026 |
| Note: Released By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM | |||
| MECH | HOLD | 05/11/2026 | 05/12/2026 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM THIS IS THE CORRECT REVIEW. PREVIOUS HAD AN INCORRECT COMMENT 1. Direction house faces on Heatload does not match the site plan. Revise to match per R403.7 FBC Energy Conservation 2023 8Th Edition 2. Design location on Energy calcs and Heatload need to be Daytona Beach 3. Plans show 3/4 in foam board on walls R5. Energy Calcs say R7. Revise When resubmitting, provide updated state cards | |||
| ENGIN1 | PENDING |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| WATER- TURN ON | ¤100.00 | |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | |
| ADMINISTRATIVE - RESID PP | ¤225.00 | |
| PLAN REVIEW - RESIDENTIAL | ¤450.84 | |
| FC IMPACT FEE EMS | ¤124.00 | |
| FC IMPACT FEE LAW ENFORCEMENT | ¤436.00 | |
| FC IMPACT FEE LIBRARY | ¤536.00 | |
| FIRE RES IMPACT FEE 10-25 | ¤1,884.00 | |
| PEP TANK INSTALL | ¤1,513.48 | |
| PARKS IMPACT FEE 10-25 | ¤6,328.00 | |
| RSI DRIVEWAY AFTER POUR | ¤16.25 | |
| RSE DRIVE PRE POUR INSPECTION | ¤32.50 | |
| RSI FORMBOARD REVIEW | ¤16.25 | |
| RSI PLAN REVIEW NEW | ¤48.75 | |
| RSI FNL SURVEY/GRADING CERT | ¤48.75 | |
| RSI ROW FINAL INSPECTION | ¤16.25 | |
| SCHOOL BOARD IMPACT FEE RES | ¤10,900.00 | |
| WASTEWATER MAIN EXTENSION IMPA | ¤4,770.00 | |
| SURCHARGE FS 533.721 | ¤7.06 | |
| SURCHARGE - FS 468.631 | ¤10.59 | |
| SW ENG RES REVIEW 240 | ¤240.00 | |
| WATER METER W/ TAP | ¤4,653.86 | |
| TRANS DUPLEX 10-25 | ¤10,707.20 | |
| SEWER CREDIT | (¤1,420.00) | |
| WASTEWATER PERM INSPECTION | ¤80.00 | |
| WASTEWATER PERM REVIEW | ¤100.00 | |
| SEWER CAPITAL FACILITY | ¤8,830.00 | |
| WATER CAPITAL FACILITY FEE | ¤8,168.50 | |
| WATER PERMIT INSPECTION | ¤80.00 | |
| WATER MAIN EXTENSION IMPACT | ¤1,960.26 | |
| SITE PLAN 30 | ¤30.00 | |
| Fees | Total Due: ¤60,923.54 | Total Paid: ¤0.00 |