Inspection History

Type Request Date Result Inspector
FINAL
LDSC- LANDSCAPE FINAL
U - UTILITY COMMERCIAL FINAL

Review History

Department Status Date In Date Out
BLD HOLD 05/12/2026 05/13/2026
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Provide engineered drawings showing 120 MPH wind speed and structural footing details for solid fence. 107.2.1 2. Plan sheets need to be digitally signed, sealed and verifiable by a licensed Florida PE. F.S.471.025 3. Reference FBC 2023 code cycle on plans 107.2.1 4. Provide gate latches and hardware details at public access gates that meet reach ranges based on direction of approach (both sides of gate) and that require no grasping, pinching or turning of the wrist. Sections 308, 309.4. 404.2.7. 5. If gates are to have spring hinges and / or gate closers, provide details in accordance with Section 404.2.8, 404.2.8.1, 404.2.8.2 and 404.2.9. 6. Show landing dimensions and areas on each side of each gate. Slopes at landings at gates not to exceed 2% in any direction. Landings to be as wide as gates plus clearance beyond latch side and 48 inches in the direction of travel based on forward approach. 7. Show required maneuvering clearances at gates including minimum clear dimension beyond latch side of gates on both sides of gates based on direction of approach and swing of gates. . 8. Show minimum clear opening width at each gate of 32 inches. Section 404.2.3. 9. Provide gate detail indicating gate surfaces within 10 inches above the ground to have smooth surfaces on the push side of gate for the full width of gates. Section 404.2.10
DSD HOLD 05/12/2026 05/12/2026
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Chainlink, aluminum, or similar metal fences shall be black or bronze in color, except that aluminum fences may also be white in color. Chainlink fences shall not have slats, fabric or similar types of screening materials attached to them.
PLLA COMPLETE 05/12/2026 05/19/2026
Note: Released By: RICHARD PICATAGI - (386)986-3760 - RPICATAGI@PALMCOASTGOV.COM
UD1 COMPLETE 05/12/2026 05/18/2026
Note: Released By: GREG DEGLER - (386)986-2384 - GDEGLER@PALMCOASTGOV.COM
DSD PENDING
BLD PENDING